Documentatie Sica Bond

Click here to load reader

  • date post

    22-Dec-2015
  • Category

    Documents

  • view

    7
  • download

    0

Embed Size (px)

description

Documentatie sika.

Transcript of Documentatie Sica Bond

  • Quality by tradition

    Flow sensors For OEM applications

  • 2SIKA has been your reliable partner for measuring and monitoring flow sensors for over 45 years. Our constant drive to innovate enables you to access a comprehensive product portfolio covering 10 different measuring principles. As a manufacturer of metrological components that are "Made in Germany", we have carved out a reputation, particularly in the areas of customised potable water, heating water, chiller and pool applications.

    SIKA provides the best possible co-engineering service, at the end of which you receive a high-grade result both in terms of quality and economics. As an original equipment manufacturer (OEM), we focus on individual solutions that fit seamlessly into our customers' existing process structures. Evidence of this can be seen for instance in the long-standing, successful cooperation with global market leaders in the heating appliance sector. For example, we have helped many manufacturers of heat pumps worldwide to meet annual requirements of about 90,000 units.

    The cooperative process at our company is built around our ultra-modern flowlabs. With the help of these test facilities, which we have developed and optimised over the years, we can adapt our products to customer-specific installation requirements. In this way, we can respond immediately to any anomalies that arise.

    In the final stage of mass production, our sensors undergo complete inspection and 100 % testing. For our vortex flow sensors, this includes calibration with up to six test points in addition to an automated function test.

    Why not profit from our expertise in developing and optimising our metrological solutions and our high standards in quality assurance? Choose flow sensors from SIKA.

    2

  • 3 Reliable pump monitoring

    For soldering into existing copper pipes or with a pipe tee

    Special protection against contamination

    Customised set point

    Glass-fiber reinforced plastics

    Used in market-leading heating appliances

    Recognized components ETL acc. to UL & CSA standards

    For energy balancing and pump control

    Sensor element encapsulated entirely in plastic

    Insensitive to pressure peaks during filling

    Integrated temperature sensor

    Threaded connection or QuickFasten

    Digital or analog output signal

    Customized setup by variables

    ETL approvals acc. to UL & CSA standards for some types

    Flow switches Vortex flow sensors

    Heating water applications

    3

  • 4 Tap water measurement for potable water heating

    Turbine body made of low lead brass or glass-fibre reinforced plastic

    Durable thanks to high-grade sapphire bearings

    Insensitive to pressure surges

    Practically independent of inflow section and installation position

    Turbine flow sensors

    Tap water detection even at low flow rates

    Pipe tees with threaded or soldering ends

    Push-in installation into manifolds or armatures

    More than three million devices in the field

    Potable water certification acc. to NSF 61 and NSF 372 for some types

    Low lead brass tees

    Flow switches

    Potable water applications

    4

  • 5 Flow meters without moving parts

    Various filters for signal optimisation

    Numerous tests - overload, rust, limestone, breakdown

    Ideal when using high-efficiency pumps

    ETL approved acc. to UL & CSA standards

    Simple integration into valves

    Comprises J Push-in turbine J Hall-effect sensor J Adapter sleeve for hall effect sensor

    Separation of hydraulic and electrical components

    For water treatment equipment

    Measures lowest flow rates/leak detection

    Vortex flow sensors Push-in turbine flow sensors

    5

  • 6 Pump monitoring

    For pool heaters or water disinfection

    Protection against overheating, dry-running and gas formation

    Installation with union nut or push-in

    Paddle reset with magnetic force

    PVC glue-in adapter for slip fit tees

    More than 1,000,000 switching cycles (load-dependent)

    Low pressure drop

    Metal-free for seawater pools

    Proven in the market leader's pool heaters

    Flow switches Flow switches

    Pool applications

    6

  • Installation into existing pipes

    Threaded, welding or soldering adapter

    Union nut connection for simple installation

    Various plug connectors or connection cables

    TV type approved

    No springs, no bellows

    For determining the energy balance

    Measurement signal independent of viscosity changes

    Free pipe cross section, no moving or protruding parts

    No additional pressure drop

    Analog and digital outputs

    Flow switches Magnetic-inductive flow sensors

    Chiller applications

    7

  • Mechanical Measuring Instruments

    Flow Measuring Instruments

    Electronic Measuring & Calibration Instruments

    Subject to technical modifications and errors

    11/2014 Edition

    Grandview Industrial Pk.1500 S. Sylvania Avenue Suite 111Sturtevant WI 53177

    Phone +1 262 886-2695Fax +1 262 898-0101

    Email [email protected]

    SIKA Systemtechnik GmbHStruthweg 7-9 34260 KaufungenGermany

    Phone +49 5605 803-0 Fax +49 5605 803-54

    Email: [email protected] www.sika.net

    HeadquatersSIKA USA Inc.