Meter Life Cycle Manual for ME lab User Important Points: 1. TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage locations for respective ME lab MELAB storage Locations TNP storage locations M101 MeLabPatiala New M102 MeLab Ropar M103 MeLab Gobindgarh M104 MeLab Goraya M105 MeLab Kartarpur M106 MeLab Gurdaspur M107 MeLab Verka M108 MeLab Bhatinda M109 MeLab Moga M110 Melab Mukatsar M111 Melab Sangrur M112 Melab Batala M113 Melab Hoshiarpur M114 Melab Ludhiana M115 Melab Jalandhar T101 TNP MeLabPatiala T102 TNP MeLab Ropar T103 TNP MeLab Gobind T104 TNP MeLab Goraya T105 TNP MeLab Kartar T106 TNP MeLab Gurdas T107 TNP MeLab Verka T108 TNP MeLab Bhatin T109 TNP MeLab Moga T110 TNP Melab Mukats T111 TNP Melab Sangru T112 TNP Melab Batala T113 TNP Melab Hoshia T114 TNP Melab Ludhia T115 TNP Melab Jaland Table 1.1 2. If Sanctioned load of consumer is Greater than equal to 25 kW

Transcript of docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage...

Page 1: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Meter Life Cycle Manual for ME lab User

Important Points:

1. TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage locations for respective ME lab

MELAB storage Locations TNP storage locationsM101 MeLabPatiala NewM102 MeLab RoparM103 MeLab GobindgarhM104 MeLab GorayaM105 MeLab KartarpurM106 MeLab GurdaspurM107 MeLab VerkaM108 MeLab BhatindaM109 MeLab MogaM110 Melab MukatsarM111 Melab SangrurM112 Melab BatalaM113 Melab HoshiarpurM114 Melab LudhianaM115 Melab Jalandhar

T101 TNP MeLabPatialaT102 TNP MeLab RoparT103 TNP MeLab GobindT104 TNP MeLab GorayaT105 TNP MeLab KartarT106 TNP MeLab GurdasT107 TNP MeLab VerkaT108 TNP MeLab BhatinT109 TNP MeLab MogaT110 TNP Melab MukatsT111 TNP Melab SangruT112 TNP Melab BatalaT113 TNP Melab HoshiaT114 TNP Melab LudhiaT115 TNP Melab Jaland

Table 1.1

2. If Sanctioned load of consumer is Greater than equal to 25 kW Then ZDIN: Device Installation Order and ZDRP: Device Replacement Order will be assigned to ME LAB user.

ME LAB User have to assign component against order through IW32 and Good Issue through MIGO

And change order status to MEAP (Melab Approved ) and enter User responsible RA for reviewing the order.

Please find below process step by step

ZDRP:

Page 2: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Enter T-code IW32 to change order

Fill Order Number and Press Enter

Page 3: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Helighted fields are ME Lab user ID and meter to be replaced (get material number by double clicking on equipment number)

Page 4: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Copy Heilighted device category is material number and go back

Page 5: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Click on component tab

Page 6: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Enter new material number for new meter to be installed in componant tab and press enter.

Enter Enter 1 in Reqmt Qty and storage location

Page 7: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Enter Meterial number of meter to be replaced in component column and press enter

Enter -1 in Reqmt Qty and storage location (Important step)

Page 8: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Change Planner Grp to RAC User responsible : RAC user ID And change order user status to MEAP (ME lab approved)

Copy Order number

Page 9: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

GO to T-code MIGO select Good Issue Order and enter Order number and press enter.

Click on serial number

Page 10: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage
Page 11: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage
Page 12: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Tick Item OK Check Document and Posting Date Click on Check Click on Post

Page 13: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

Kindly follow same process for ZDIN order except only one component to be selected against order (which is to be installed).

Page 14: docs.pspcl.in · Web viewMeter Life Cycle Manual for ME lab User Important Points: TNP storage location for all MELAB is Starts with alphabets T, Please refer Table 1.1 for TNP storage

3. Reports: ZDM_MTR_RMD_MELABSelection Screen

MELAB Code: T101 (This is TNP storage location for M101)

Output screen:

Test Meter and Select check box and select respective button on top.