Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE...

11
doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, Infopia Slide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Project: IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs) Networks (WPANs) Submission Title: u-health applications using WBAN Date Submitted: [14 May, 2008] Source: Gu Youn Kim, Sung Dong Lee[Infopia], Yoon Seok Nam, Hyung Soo Lee[ETRI] Contact: Gu Youn Kim, Infopia, Korea Voice: :+82-31-423 6170, E-mail:[email protected] Re: [n/a] Abstract: Introducing applications of commercial glucose monitoring systems Purpose: To introduce applications of commercial glucose monitoring systems Notice: This document has been prepared to assist the IEEE P802.15. It is offered as a basis for discussion and is not binding on the contributing individual's or organization's. The material in this document is subject to change in form and content after further study. The contributor's reserves the right to add, amend or withdraw material contained herein. Release: The contributor acknowledges and

Transcript of Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE...

Page 1: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 1

Project: IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs)Project: IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs)

Submission Title: u-health applications using WBANDate Submitted: [14 May, 2008]Source: Gu Youn Kim, Sung Dong Lee[Infopia], Yoon Seok Nam, Hyung Soo

Lee[ETRI]Contact: Gu Youn Kim, Infopia, KoreaVoice: :+82-31-423 6170, E-mail:[email protected]: [n/a]Abstract: Introducing applications of commercial glucose monitoring systemsPurpose: To introduce applications of commercial glucose monitoring systemsNotice: This document has been prepared to assist the IEEE P802.15. It is offered

as a basis for discussion and is not binding on the contributing individual's or organization's. The material in this document is subject to change in form and content after further study. The contributor's reserves the right to add, amend or withdraw material contained herein.

Release: The contributor acknowledges and accepts that this contribution becomes the property of IEEE and maybe made publicly available by P802.15.

Page 2: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 2

Overview of presentation

• u-Healthcare Systems• Glucose Monitoring Systems• GlucoMeter• GluecoCellphone• Doctor’s Review• System Specifications of GlucoMeter• Measurement and Data• Issues

Page 3: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 3

WBANWBAN

u-Healthcare Systems

VITAL SIGNS MEASUREMENTVITAL SIGNS MEASUREMENT

DATA COLLECTIONDATA COLLECTION

CARE TEAM FOR PATIENTCARE TEAM FOR PATIENT

• Healthcare systems measure – Blood pressure and pulse, ECG, Glucose

• Healthcare is a part of WBAN.

Page 4: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 4

WPANWPANIn Door

In Door

Indoor/OutdoorIndoor/Outdoor

Glucose Monitoring Systems• Categories

– Indoor : potable system w/wo networking capabilities– Indoor/outdoor : cellphone with glucose module

GlucoMeter

GlucoCellphone

Page 5: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 5

• A patient tests the blood glucose level with GlucoMeter.• GlucoMeter sends the results by using Bluetooth.• Bluetooth gateway(PC or cellphone) relays the results to

dstination.

1.Insert test strip. The code number is automatically entered.

2.Select activities related to the test result by press button.

3.Apply sample until confirmation window is comple -tely filled before the meter begins to count down.

4.Test results in 3 seconds.

5. Pressing send button, the results are transmitted to PC or cellphone.

Bluetooth

GlucoMeter

Page 6: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 6

• Cellphone with gluecose module• The cellphone identifies the module and executes diabetes

program.• It sends the results to destination.

1.Insert glucose check module to mobile phone.

2. Diabetes program is automatically executed.

3.Insert test strip.

4.Test results in 9 seconds.

5. Send the results to destination

GluecoCellphone

Page 7: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 7

• Doctors review, chart and consults online.– Trend graph, Graph by hour, Prescription

Analysis of Medical data

Page 8: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 8

Items Contents

Communication Bluetooth 2.0

Interface USB

Test range 10 ~ 600 mg/dL (0.5~33.3mmol/L)

Hematocrit Range 20~60%

Test Latency 3 seconds

Sample Blood Volume 0.3uL

Open use time (Strip) 3 months

Strip storage temperature 2 ~ 30o C

Coding Auto Coding

Memory capability 7, 14, 21-day average and 250 tests in the memory

Power 3V(1.5V AAA size Alkaline Battery X 2)

Power consumption Standby Mode: <1mA, TX/RX Mode: < 50mA

Battery life 200 days

Size: LxWxH (mm) 52.2×98.5×23.4

Weight 74.5g( including battery)

System Specifications of GlucoMeter

Page 9: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 9

• Measurement– Normally, 9~10 times per day

• Early morning, • (Before/After) breakfast/lunch/dinner, • Before bedtime, Amount of exercise…

• Data– 20 bytes / test– Glucose level, Body Temperature, Measurement time, Activities,

User ID

Measurement and Data

Page 10: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 10

• Low Power– Plan to adopt WBAN technology in GluecoMeter

• Networking– Therapy management software solutions may control medical sensors

and actuators, and inter-network properly.

Issues

Page 11: Doc.: IEEE 802. 15-08-0359-00-0006 Submission May 2008 Gu Youn Kim, InfopiaSlide 1 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks.

doc.: IEEE 802. 15-08-0359-00-0006

Submission

May 2008

Gu Youn Kim, InfopiaSlide 11Slide 11

Thank You !

Questions ?