DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig....

15
DNV-OS-F101 Checker TM User Manual DNV-OS-F101 Checker ® User Manual For Version: 1.0.9 Copyright © 2010-2016 OPIMsoft Technology Co., Ltd. All Rights Reserved.

Transcript of DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig....

Page 1: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

DNV-OS-F101 Checker®

User Manual For Version: 1.0.9

Copyright © 2010-2016 OPIMsoft Technology Co., Ltd. All Rights Reserved.

Page 2: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

INDEX

1 FUNCTION ....................................................................................................................... 1

2 INSTALLATION ................................................................................................................. 2

3 HOW TO USE ................................................................................................................... 3

4 INTERFACE DETAIL ........................................................................................................ 7

5 TECHNICAL SUPPORT & AUTHORIZATION ................................................................ 13

Page 3: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

1

1 FUNCTION

Offshore Standard DNV-OS-F101 -- Submarine Pipeline Systems, developed by DET

NORSKE VERITAS (DNV), is a widely used standard which gives criteria and guidance on

concept development, design, construction, operation and abandonment of Submarine

Pipeline Systems.

DNV-OS-F101 CheckerTM is a set of PC software developed to check design limit state

criteria in Section 5 of DNV-OS-F101. Actually, although DNV-OS-F101 CheckerTM is similar

with some software of the same kind, it has several more features as following:

1. DNV-OS-F101 CheckerTM combines DNV-OS-F101 2000, 2007, 2010, 2012 and 2013

together. Users can choose any version as check criteria.

2. DNV-OS-F101 CheckerTM has more functions, such as buckle arrestor capacity check

and accidental load check.

3. AUTOPIPE result check. AUTOPIPE result file can be checked by DNV-OS-F101

CheckerTM directly and easily.

Page 4: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

2

2 INSTALLATION

To start to use DNV-OS-F101 CheckerTM, please:

For soft lock edition user:

1. Download software from official website to licensed PC.

2. Replace the original “license.dll” file with the one received.

3. Double click “DNV-OS-F101 Checker.exe” icon in the folder to start the software.

For dongle edition user:

1. Download software from official website.

2. Replace the original “license.dll” file with the one received.

3. Insert the attached dongle into one of USB ports of your PC.

4. Double click “DNV-OS-F101 Checker.exe” icon in the folder to start the software.

DNV-OS-F101 CheckerTM runs on PC with Windows OS.

Page 5: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

3

3 HOW TO USE

Brief procedure of running DNV-OS-F101 CheckerTM is shown as following:

1. Choose DNV-OS-F101 version

Click on the down arrow of combobox “DNV-OS-F101 Version” to choose DNV-OS-F101

version for check. Some parameters will appear or disappear according to the version user

chosen. DNV-OS-F101 CheckerTM provides 5 versions of DNV-OS-F101 for user to choose,

which are 2000, 2007, 2010, 2012 and 2013. All the versions are latest amended version.

Fig. 3.1 Choose DNV-OS-F101 version

2. Specify check items

Click on the checkbox “Burst”, “Collapse and Propagating”, “Buckle Arrestor” in “WALL

THICKNESS DESIGN” groupbox and checkbox “Load Controlled”, “Displacement

Controlled” in “LOAD INTERACTION” groupbox to specify the items user wants to check.

Color of the blanks need to be filled will change to blue corresponding to the items user

specified.

Page 6: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

4

Fig. 3.2 Specify check items

3. Input parameters

Input all the parameters into the blanks which are blue. Click “Open Case” or “Save Case”

tool button to read the parameters from case file or save the parameters as a case file.

4. Calculate

Click “Run” tool button to run the check calculation. One of the EXCEL sheet will show in the

right side of interface and the check result will show in the sheet.

5. AUTOPIPE check

Click ”Show AUTOPIPE Panel” checkbox, then AUTOPIPE check panel will appear at right

side.

Page 7: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

5

Fig. 3.3 AUTOPIPE check

Functions of the buttons on AUTOPIPE check panel are:

“Open Case” and “Save Case”: Read and save parameters inputted for AUTOPIPE.

“Add” and “Delete”: Add or delete an AUTOPIPE section.

“Up” and “Down”: Move the position of an AUTOPIPE section.

“Rename All”: Rename all the sections as “Section X”. By double clicking the name of

section in the following listbox, user can input name for the section.

“Pre-Process”: Prepare the check worksheet for AUTOPIPE. A dialogue box will show for

user to choose an AUTOPIPE output file. Then one EXCEL sheet will be opened. After that,

a file which has the same name with the AUTOPIPE output file but an additional prefix

“Filtered-” will be generated in the directory of AUTOPIPE output file, in which unwanted

information is deleted. It should be noted that, user should set the AUTOPIPE output file as

the format in which functional load is put in the first line and environmental loads in following

lines. In sheet 1, input parameters and intermediate results will be listed. in sheet 2, all the

nodes and work case name will be listed, user should specify section number (1, 2, 3…) for

each node and specify “ULS” or “ALS” for each work case. If “ULS” is specified, then the

load values in the line of this work case will be recognized as environmental loads,

accidental loads is set as zero, load combination “a” and “b” will be checked. If “ALS” is

specified, then the load values in the line of this work case will be recognized as accidental

Page 8: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

6

loads, environmental loads is set as zero, load combination “d” will be checked. After clicking

“Pre-Process”, “Calculate” button will be enabled.

“Calculate”: Run the check for AUTOPIPE, results will be calculated and showed in sheet 3

and following sheets.

The sections will show in the below box, click them, and then input the parameters for the

current section in the blue blanks in left part.

Page 9: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

7

4 INTERFACE DETAIL

Fig. 4.1 Main interface of DNV-OS-F101 CheckerTM

1. “HEADING” groupbox:

Input description of the check.

2. “DNV-OS-F101 Version” groupbox:

Choose DNV-OS-F101 Version.

3. “GEOMETRY” groupbox:

“OD” or “ID”: Select to input outer or inner nominal diameter of pipe.

“tnom”: Norminal steel pipe wall thickness.

“tfab”: Fabrication thickness tolerance.

“tcorr”: Corrosion allowance. To be subtracted from nominal thickness if section is assumed to

be corroded.

“f0”: Out-of-roundness, DNV’s definition: f0=(Dmax-Dmin)/D. Not to be taken less than 0.5%.

“αgw”: Girth weld factor.

Ref. OS-F101 2000, Section 12, F 900.

Page 10: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

8

Ref. OS-F101 2007, Section 13, E 1000.

Ref. OS-F101 2010, Section 13, E 1000.

Ref. OS-F101 2012, Section 13, D 1000.

Ref. OS-F101 2013, Section 13, D 1000.

4. “MATERIAL” groupbox:

“SMYS”: Specified Minimum Yield Stress.

“SMTS”: Specified Minimum Tensile Strength.

“SMYS-fy,temp”: Derated yield stress at operating temperature.

“SMTS-fu,temp”: Derated tensile strength at operating temperature.

“fy,temp”: Derating values of yeild stress at operating temperature.

“fu,temp”: Derating values of tensile strength at operating temperature.

Ref. OS-F101 2000, Section 5, B 604, Figure 5-1.

Ref. OS-F101 2007, Section 5, C 304, Figure 2.

Ref. OS-F101 2010, Section 5, C 304, Figure 2.

Ref. OS-F101 2012, Section 5, C 304, Figure 2.

Ref. OS-F101 2013, Section 5, C 304, Figure 2.

“E”: Young's modulus.

“ν”: Poisson's ratio.

“αA”: Anisotropy factor. Normally equal to 0.95 when axial stresses are considered. Equal to

1.00 in other cases.

Ref. OS-F101 2000, Section 5, B 604.

“αh”: Maximum allowed yield to tensile ratio.

Ref. OS-F101 2000, Section 6, C 200, Table 6-3.

Ref. OS-F101 2007, Section 7, B 400, Table 7-5.

Ref. OS-F101 2010, Section 7, B 400, Table 7-5.

Page 11: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

9

Ref. OS-F101 2012, Section 7, B 400, Table 7-5.

Ref. OS-F101 2013, Section 7, B 400, Table 7-5.

“αfab”: Reduction in SMYS in hoop direction caused by fabrication processes.

Ref. OS-F101 2000, Section 5, B 606, Table 5-3.

Ref. OS-F101 2007, Section 5, C 307, Table 5-7.

Ref. OS-F101 2010, Section 5, C 307, Table 5-7.

Ref. OS-F101 2012, Section 5, C 307, Table 5-5.

Ref. OS-F101 2013, Section 5, C 307, Table 5-5.

“Suppl. U req.”: Check off if supplementary requirement "U" is fulfilled. Affects the material

strength factor aU.

Ref. OS-F101 2000, Section 6, D 500.

Ref. OS-F101 2007, Section 6, B 409.

Ref. OS-F101 2010, Section 6, B 409.

Ref. OS-F101 2012, Section 6, B 410.

Ref. OS-F101 2013, Section 6, B 410.

5. “LOADS” groupbox:

“pdesign”: Design pressure.

“ptest”: System test pressure.

“pmin”: Minimum pressure.

“@”: Level relative to MSL at which the pressure is applied.

“ρdesign”: Density of content in design/operation condition.

“ρtest”: Density of content in system test.

“ρmin”: Minimum density of content.

“γinc”: Incidental pressure to design pressure ratio. Normally equal to 1.10. Not less than

1.05.

Page 12: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

10

Ref. OS-F101 2000, Section 3, B 300.

Ref. OS-F101 2007, Section 3, B 305, Table 3-1.

Ref. OS-F101 2010, Section 3, B 305, Table 3-1.

Ref. OS-F101 2012, Section 3, D 209, Table 3-1.

Ref. OS-F101 2013, Section 3, D 209, Table 3-1.

“Depth”: Depth relative to Mean Sea water Level (MSL) at which pipeline lies. Enter a

positive number (assuming that the pipeline is submerged).

“ρext”: Density of external fluid.

“Max. Elevation”: Maximum elevation relative to MSL. Enter a number equal to or greater

than zero. Max. Depth = Depth + Max. elevation is used for collapse and propagating

buckling checks. Not used for Load Interaction calculations. Max. and min. elevation is

usually high and low tide, respectively.

“Min. Elevation”: Minimum elevation relative to MSL. Enter a number equal to or less than

zero. Min. Depth = Depth + Min. elevation is used for burst checks. Not used for Load

Interaction calculations. Max. and min. elevation is ususally high and low tide, respectively.

6. “WALL THICKNESS DESIGN” groupbox:

“psyst-test”: Minimum local system test pressure (at reference level given for design above).

Note that the minimum test pressure depends on safety class in operation. It is assumed that

the system test medium has at least the same density as the content during operation.

Ref. OS-F101 2000, Section 5, B 202.

Ref. OS-F101 2007, Section 5, B 203.

Ref. OS-F101 2010, Section 5, B 203.

Ref. OS-F101 2012, Section 5, B 202.

Ref. OS-F101 2013, Section 5, B 202.

“pmill-test”: Minimum mill test pressure. Note that tmin = t1.

Ref. OS-F101 2000, Section 6, E 1103.

Ref. OS-F101 2007, Section 7, E 102.

Page 13: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

11

Ref. OS-F101 2010, Section 7, E 102.

Ref. OS-F101 2012, Section 7, E 102.

Ref. OS-F101 2013, Section 7, E 102.

“DBA”: Buckle arrestor outer diameter.

“tBA”: Buckle arrestor wall thickness.

“LBA”: Buckle arrestor length.

“Safety Class”: Safety Class, specified individually for each failure mode/condition.

“Corr.”: Check off if corrosion allowance tcorr is to be subtracted from tnom in code check.

“Der.”: Check off if derated material strength is to be used in code check.

“treq”: Minimum required nominal wall thickness.

“utility”: Based on the nominal wall thickness given under GEOMETRY. See also formulae on

Report sheets.

7. “LOAD INTERACTION” groupbox:

“γC”: Load condition factor, Ref. Sec. 5 Tab. 5-7.

Ref. OS-F101 2000, Section 5, D 304, Table 5-7.

Ref. OS-F101 2007, Section 4, G 203, Table 4-5.

Ref. OS-F101 2010, Section 4, G 203, Table 4-5.

Ref. OS-F101 2012, Section 4, G 304, Table 4-5.

Ref. OS-F101 2013, Section 4, G 304, Table 4-5.

“Func.”: Functional loads.

“Env.”: Environmental loads.

“Acc.”: Accidental loads.

“Condition”: The chosen condition determines internal pressure according to the input under

LOADS, or is zero if condition is EMPTY.

“Safety Class”: Safety Class.

Page 14: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

12

“Limit State”: Limit State.

“Corr.”: Check off if corrosion allowance tcorr is to be subtracted from tnom in code check.

“Der.”: Check off if derated material strength is to be used in code check.

“treq”: Minimum required nominal wall thickness.

“utility”: Based on the nominal wall thickness given under GEOMETRY. See also formulae on

Report sheets.

Page 15: DNV-OS-F101 Checker User Manual - OPIMsoft Checker User...DNV-OS-F101 CheckerTM User Manual 5 Fig. 3.3 AUTOPIPE check Functions of the buttons on AUTOPIPE check panel are: “Open

DNV-OS-F101 CheckerTM

User Manual

13

5 TECHNICAL SUPPORT & AUTHORIZATION

For technical support and authorization of DNV-OS-F101 CheckerTM, please visit:

http://www.opimsoft.com

or contact:

[email protected]