Distributor presentation mx
-
Upload
macnaught -
Category
Technology
-
view
783 -
download
4
description
Transcript of Distributor presentation mx
flow measurement
Presentation Overview
1.Flow meter technology
2.Positive Displacement - Principle of operation.
3.Ideal applications
4.What's new
5.Introducing the new generation MX series Flowmeters.
Flowmeter Technologies
There are 4 general groupings by which a flow meter can be categorised, according to the technology adopted.
Velocity Inferential Mass Volumetric
Flow Measurement Technology
Volumetric Flowmeter
‘Directly measure the total volume of the fluid passing through the pipe’
Oval Gear Rotary Nutating Disc Bi-Rotor Spur Gear Oscillating Piston
Flow Measurement Technology
Typical Applications
Volumetric
• Batching• Dispensing• Dosing• Fuel Consumption• Applications requiring accurate
totals
Flow Measurement Technology
Positive DisplacementFlowmeter
Principle of Operation
A precision engineered measuring chamber houses a pair of oval rotors which rotate during flow conditions
Meter Construction
Principle of Operation
As the Rotors turn they sweep a measured volume of liquid through the measuring chamber
Measuring Chamber
Measured Volume
Principle of Operation
• Each of the Rotors are fitted with magnets on the top face.
• As the Rotor turns the
magnet activates a switch which is fixed to a Printed Circuit Board (PCB)
• This in turn generates a Pulse Output
Principle of Operation
Our Sensor Boards (PCB) incorporate two types of switches.
Reed Switch
Mechanical Switch
Hall Effect SwitchSolid State
Electronics – Printed Circuit Board
Calculating Flow Rate• The K- Factor is … ‘The number of Sensor Pulses per Unit of
Measure’ (Litre or US gallon)
• Each meter is assigned an individual K-Factor calculated during our calibration checks
Example …. A meter has an independent K-Factor 36 (= 36 pulses per
litre) Each pulse generated by the meter is the equivalent to
1 Ltr 36 = 27.8 ml An Electronic device (Signal Conditioner) is used to convert
these pulse outputs to Flow Rate and Total Flow
K-Factor
The Benefits associated with a PD Meter
Technical Specifications
Accuracy• +/- 0.5% (500ml in every 100 litres)
Repeatability• 0.03% (30ml in every 100 litres)
Flow Measurement Technology
Installation and Commissioning
Reliable Robust Easily maintained on site No pipe conditioning required Suitable for variations in medium
(e.g. viscosity, concentrations, etc. )
Flow Measurement Technology
Suitable Applications
Dispensing
RefuellingVehicle ServicingDrum FillingChemical Packaging
Positive Displacement Flow Meters
Ideal Applications
Servicing and Transfer
Diesel Service Truck
Diesel Service Truck
Diesel Service Truck
Ideal Applications
Batching
Chemical Dilution and PackagingFood / BakingAnimal Feed
Flow Measurement Technology
Automatic Batching
Automatic Filling System
Multiple Drum Filling
Portable Batching System
New application – AdBlue metering
Fuel Consumption System
Recirculation Fuel System - Meter Installation - Schematic
MasterReceiving Instrument
Fuel
FilterNon-Return
Fuel Consumption
Valve calculated asMeter P1 - Meter P2
Fuel Tank Engine
Filter
Meter P1
Meter P2
Ideal Applications
High Viscosity
Fuels and Lubricants Paints and Coatings Adhesives Printing Ink Cleaning Chemicals
Positive Displacement Flow Meters
Agricultural Dispensing
What’s New?
The new MX Flowmeter series
Pulser range only Manufactured from solid Billet
(St.St and Aluminium) Increased Temp (150oC) Pressure Ratings (2000psi) Anodised Aluminium body Choice of 9 interchangeable
Pulse Output or Display Modules.
M-Lock™ mounting system
We have developed a new ¼” turn (Bayonet fitting) mounting system for our Pulse Output and Display modules.
Approved for Hazardous Areas
Intrinsically Safe (Ex ia)
Flameproof (Exd)
Approved ATEX,
Approved IECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Online Resources
Macnaught has developed a comprehensive set of web based resources in order to support customers throughout the entire process of selecting, applying and maintaining the MX Flow meter range.
http://www.macnaught.com.au/mx_resources/index.html
Automated Flowmeter Selection Tool
Specifications Tool
Conversion Tool (coming soon)
Interactive Web Tools
Online Information
General web based resources
Quick Reference GuidesGeneral Specifications3D DrawingsInstruction ManualsService VideosBrochures
Marketing Resources
MX Demo Kit
We have developed an MX Demonstration Kit to compliment the launch of the MX series.
table top exhibitionsin-house displaystaff trainingdirect sales tool.
Overview of the new generation MX Series
Flowmeter Range overview The range consists of over
1,000 flowmeter models.
Process Connection sizes range from ¼” to 4”
(6mm – 100mm)
Flow Rates range from
0.0083 – 1200 l/min
Stainless Steel and Alum.
Range Segmentation
Application Based Focused on Ideal applications1. Fuel and Oil
2. Solvent
3. Industrial
All Inclusive PART number1. Includes Flange Styles
2. Includes displays
MX part numbering convention
MX25F-1SABreakdown of the part numbering system
Part Number
MX25F-1SABreakdown of the part numbering system
MX … Flowmeter Series
Part Number
MX25F-1SABreakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
Part Number
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Family
Part Number
FMX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Family
1 … Port style (process connection)
Part Number
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Family
1 … Port style (process connection)
S … Rotor Type
Part Number
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Family
1 … Port style (process connection)
S … Rotor Type
A … Display or Pulser Output Type
Part Number
MX25F-1SA
MX25F-1SA
Size and Flow Range
Model No. (mm) Size Flow Range
MX06 ¼” 0.5 – 100 l/hr
MX09 ¼” 15 – 500 l/hr
MX12 ½” 2 – 30 l/min
MX19 ¾” 3 – 80 l/min
MX25 1” 6 – 120 l/min
MX40 1 ½” 10 – 250 l/min
MX50 2” 15 – 500 l/min
MX75 3” 20 – 750 l/min
MX100 4” 120 – 1200 l/min
Fuel and Oil (F)
• Al meter body• PPS rotors• Viton Seals
Fuel & Oil Flowmeters
Industry Type or Family
Solvents (S)
• Al meter body• SS rotors• Teflon Seals
Industrial (P)
• SS meter body• PPS or SS rotors• Teflon Seals
MX25F-1SA
1. BSP (Rp)
2. NPT
3. ANSI 150lb
4. JIS 10K
5. DIN PN16
MX25F-1SA
Port Style (process connection)
Fuel and Oil series
S = PPS Rotors
Solvent series
S = Models MX06 - MX025 Stainless Steel Rotors
Models MX40 – MX100 Aluminium Rotors
Industrial series
S = PPS
V = High Viscosity Stainless Steel Rotors
T = High Temp Stainless Steel
MX25F-1SA
Rotor Type
A Standard Pulse
B Intrinsically Safe (Ex ia)
C Flameproof (Ex d)
D PR (12mm LCD)
E PRA (12mm LCD with outputs)
F ER (17mm LCD)
G ERA (17mm LCD with outputs)
H ERB (17mm LCD Batch controller)
T High Temp (max 150oC)
MX25F-1SA
Display or Pulser Output Modules
Pulser Output and Display Modules
Type A Compact
Compact
• Polypropylene Housing
• IP 67
• Pulser Output
• 1x Reed switch
• 1x Hall Effect (NPN)
Type B Approved Ex ia
Intrinsically Safe
• Stainless Steel• Pulser Output• NPN Open Collector• Approved Ex ia• ATEX• FM• CSA• IECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Type C Approved Exd
Flameproof
• Stainless Steel
• Pulser Output
• NPN Open Collector
• Approved Exd
• ATEX
• IECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Display • Meter Mount or Wall Mount
• Polypropylene Housing IP67
• 7 Digit – 12mm upper
• 7 Digit – 8mm lower
• Total Resettable
• Flow Rate
• Accumulated Total (non-resettable)
Type D PR Digital Display
Display • Meter Mount or Wall Mount
• Polypropylene Housing IP67
• 7 Digit – 12mm upper
• 7 Digit – 8mm lower
• Total Resettable
• Flow Rate
• Accumulated Total (non-resettable)
Outputs • 4-20mA (passive)
• Scaled Pulse Output
• Hi/Lo Flow Alarm
Type E PRA Digital Display
Display• Meter Mount or Remote Mount
• Aluminium housing IP 67
• 7 Digit – 17mm upper
• 7 Digit – 8mm lower
• Total Resettable
• Flow Rate
• Accumulated Total (non-resettable)
Type F ER Digital Display
Display• Meter Mount or Remote Mount
• Aluminium housing IP 67
• 7 Digit – 17mm upper
• 7 Digit – 8mm lower
• Total Resettable
• Flow Rate
• Accumulated Total (non-resettable)
Output • 4-20mA (passive)
• Scaled Pulse
Type G ERA Digital Display
Display• Meter Mount or Remote Mount
• Aluminium housing IP 67
• 7 Digit – 17mm upper
• 7 Digit – 8mm lower
• Total Resettable
• Flow Rate
• Accumulated Total (non-resettable)
Output • 4-20mA (passive)
• Scaled Pulse
Type H ERB Batch Controller
Type T High Temperature
Intrinsically Safe
• Stainless Steel
• Pulser Output
• NPN Open Collector
• Max temp 150oC
ERS Digital Register
Summation / Differential
Display• Remote Mount only• Aluminium housing IP 67• 7 Digit – 17mm upper• 7 Digit – 8mm lower• 2 Flowmeter inputs• Calculates differential• Sums
Output • Transistor
AccessoriesFlanged Process Connections
• Flanges are now screwed into the Meter body
• Available in ANSI, DIN, JIS
Wall Mount Adaptors
• Aluminium wall mount adaptors available for models MX06-25
Strainers / Air Eliminators
• A variety of SS Y-Strainers, and Air Eliminator/Strainer combinations are available.
Turck Cables
•2mtr cables to suit Ex ia and High Temp Pulser switches
End Presentation