Directive Train Horn Demonstration System Performance

21
TRB ADC40 Noise and Vibration 2006 Summer Meeting Acoustics and Noise and Control Services Directive Train Horn Demonstration System Performance Paul Burgé, INCE BD.CERT, URS Corporation Parke Rhoads, Acentech Incorporated

description

Directive Train Horn Demonstration System Performance. Paul Burgé, INCE BD.CERT, URS Corporation Parke Rhoads, Acentech Incorporated. The Train Horn Problem : Train horn noise is typically the loudest and most annoying component of train noise in areas near grade crossings - PowerPoint PPT Presentation

Transcript of Directive Train Horn Demonstration System Performance

Page 1: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Directive Train Horn Demonstration System PerformancePaul Burgé, INCE BD.CERT, URS Corporation

Parke Rhoads, Acentech Incorporated

Page 2: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

The Train Horn Problem: Train horn noise is typically the loudest and most

annoying component of train noise in areas near grade crossings

Train horn soundings are generally required at most highway/rail grade crossings

Most train horns are generally omni directional, casting acoustical energy in all directions without regard to where the signal is needed or unwanted.

Page 3: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Train Horn Directionality

Source: Raposa and Fleming, IWRN 2001

Page 4: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Train Horn Noise Solutions: More grade separations Quad gate crossings Median barriers One way streets Wayside horns Directional train horns

Page 5: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Directional Train Horn Concept:

Source: Coate, Kern and Africk, IWRN 2001

Page 6: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Directional Train Horn Benefits:

•Fleet horn upgrades would provide noise reduction benefit at all grade crossings where horns are currently sounded

•No ambiguity or habituation (relative to wayside horn)

•Would work for virtually all grade crossing configurations

•Retains traditional train horn warning signal information with regard to train’s relative proximity and direction

•Could be implemented in a cost efficient manner

•Looks “cool”

Page 7: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Cancellation(destructive interference)

Summation(constructive interference)

Acoustic Line Array:–

Page 8: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Direction Train Horn Demonstration Opportunity: Contractors URS and Acentech were asked by The Los Angeles County Metropolitan Transit Authority (MTA) to develop a unit to demonstrate whether a directive horn could successfully reduce crossing noise levels noise levels on recently opened MTA Gold Line light rail transit line under an existing contract

Typical MTA Gold Line

grade crossing

Page 9: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Demonstration System Project Approach

• Evaluate existing warning system

• Design system for improved directivity

• Static laboratory tests and refinement

• Limited static and dynamic field test and refinement (road vehicle)

• Full static and dynamic field test and evaluation (rail vehicle)

Page 10: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

MTA Gold Line LRT Vehicle

Existing Train Horn Directivity (dBA)

40

50

60

70

80

90

1000

1530

45

60

75

90

105

120

135

150165

180-165

-150

-135

-120

-105

-90

-75

-60

-45

-30-15

Page 11: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Proposed train mounted array horn (artist’s conception)

Page 12: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Directional array demo system and block diagram

Page 13: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Truck mounted horn array

Page 14: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

measurement positionsposition distance angle

1 50 02 50 153 50 304 50 455 50 606 50 757 50 908 50 1059 50 12010 50 13511 50 -13512 50 -9013 50 -4514 100 -9015 100 016 100 90

50 ft.

100 ft.

12

34

5

6

7

8

9

1011

12

13

14

15

16

Directivity Test setup

Page 15: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Measured Warning System Directivity

40

50

60

70

80

90

1000

1530

45

60

75

90

105

120

135

Traditional Horn

MTA Horn

Array

Array and MTA horn levels at 50 feetTraditional horn (Leslie RS-3L) levels at 100 feet

Page 16: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Monitor LocationsMon. # Set up A Location Set up B LocationM1 Middle of run, 25' back Middle of run, 25' backM2 End of run, 25' back 50' past run, 25' backM3 Middle of run, 50' back Start of run, 50' backM4 End of run, 50' back 50' past run, 50' backM5 Middle of run, 100' back 50' before run, 50' backM6 End of run, 100' back 50' Past run, 100' back

direction of travel sounding region

A1/B1

A3

A5

A2

A4

A6

B2

B4

B6

B3 B5

N S

50 feet

Dynamic pass-by test setup

Page 17: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Dynamic pass-by test setup

Page 18: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Horn Vs. Array (quacker) Horn Array Reductionrec. loc. description Ldn %HA Ldn %HA Ldn %HAA1/B1 Middle of run, 25 ft. back 67.9 20.4 55.7 4.5 12.2 15.9A2 End of run, 25 ft. back 69.0 22.6 55.4 4.3 13.6 18.3A3 Middle of run, 50 ft. back 58.7 7.1 48.3 0.7 10.4 6.4A4 End of run, 50 ft. back 62.4 11.5 50.1 1.3 12.3 10.2A5 Middle of run, 100 ft. back 53.2 2.8 43.3 0.0 9.9 2.8A6 End of run, 100 ft. back 56.3 5.0 45.7 0.0 10.6 5.0B2 50 ft. past run, 25 ft. back 65.7 16.5 54.2 3.4 11.5 13.0B3 Start of run, 50 ft. back 54.5 3.6 44.1 0.0 10.4 3.6B4 50 ft. past run, 50 ft. back 63.4 12.9 50.4 1.4 13.0 11.4B5 50 ft. before run, 50 ft. back 47.0 0.0 42.7 0.0 4.3 0.0B6 50 ft. past run, 100 ft. back 57.5 6.0 46.9 0.0 10.6 6.0

Community Noise Analysis

Page 19: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Future Design Refinements

• Varying Number or Directivity of Array Elements

• Curved Array Geometry

• Non-uniform Array Element Spacing

• Electronic Delay and Phasing

• Higher-order Gradient Array Configuration

Page 20: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Optimal Warning System DirectivityWarning System Directivity (dBA)

40

50

60

70

80

90

1000

1530

45

60

75

90

105

120

135

Traditional Horn

MTA Horn

Array

Optimal

Array and MTA horn levels at 50 feetTraditional horn (Leslie RS-3L) levels at 100 feet

Page 21: Directive Train Horn Demonstration System Performance

TRB ADC40 Noise and Vibration 2006 Summer Meeting

Acoustics and Noise and Control Services

Questions or

Comments