DIRECT VENT DIRECT VENT CHIMNEY - mtlfab.com
Transcript of DIRECT VENT DIRECT VENT CHIMNEY - mtlfab.com
DIR
ECT
VEN
T CH
IMN
EY
DIRECT VENTFOR USE WITH GAS-FIRED APPLIANCES.
DIR
ECT
VEN
T PR
OD
UC
TS
The special double-wall construction of Metal-Fab Direct Vent allowsdirect vent stoves and fireplaces to operate without using air from insidethe building. These direct vent appliances draw combustion air in fromoutdoors through the direct vent system, meaning that warm inside air isnot being used to fuel the appliance. The appliance burns efficientlywithout creating fumes, condensation or smoke in the room.
APPLIANCEADAPTER
APPLIANCEADAPTER
APPLIANCEADAPTER
APPLIANCEADAPTER
PAINTED ROOF SUPPORT W/TRIM
CAT NO.4DAL5DAL
8DVAL
ADJUSTABLE RANGEA B C4.00"5.00"
6.50"8.00"
11.75"11.75"
3.00" TO 10.00"3.00" TO 10.00"
8.00" 11.00" 11.75" 3.00" TO 10.00"
AB
C
ADJUSTABLE LENGTH
CAT NO.4DDA5DDA
A B C4.00"5.00"
6.50"8.00"
6.64"8.01"
C
5.00
B
A
DURAVENT ADAPTER
4D6CAT NO.
4D124D184D244D364D48
4.00"4.00"4.00"4.00"4.00"4.00"
6.50"6.50"6.50"6.50"6.50"6.50"
6.00"12.00"18.00"24.00"36.00"48.00"
24.00"
8.00"8.00"8.00"8.00"8.00"
5.00"5.00"5.00"5.00"5.00"5.00"
5D6CAT NO.
5D125D185D245D365D48
A B C A B C
CAT NO. A B CC
BA
STRAIGHT LENGTH ASSEMBLY
8DV368DV48
8DV248DV12
8DV6
8.00"
8.00" 11.00"11.00"11.00"11.00"
11.00"
8.00"8.00"8.00"8.00"
6.00"12.00"18.00"
36.00"48.00"
6.00"12.00"18.00"36.00"48.00"
Note: Twist-Lock Pipe overlaps 1½" when joined together. Therefore, assembled length on all sizes is 1½" less than listed length.
SLIP CONNECTOR
CAT NO.4DSLA
A B C4.07" 6.43" 7.75"
AB
C
1.00
CAT NO.4DMA
A B C4.00" 6.50" 7.07"
AB
C
5.00
MONESSEN ADAPTER
CAT NO.54DTA
A B C4.00" 6.50" 8.00"
5" TO 4" ADAPTER
D5.00"
C
5.44
8.25
BA
D
CAT NO.4DNAS
A B C4.00" 6.50" 7.16"
C
5.88
AB
NAPOLEON STOVE ADAPTER
CAT NO.4DNA5DNA
A B C4.00"5.00"
6.50"8.00"
7.03"8.08"
C
5.00
BA
NAPOLEON ADAPTER
CAT NO.3FPC
A B2.94" 4.63"
4.63"3.94"
B
A
0.38
2.194FPC
FLEX PULLER/CONNECTOR
CAT NO.4D90A
A B C4.00" 6.50" 6.50" 6.50"
D
AB
D
C90° ADAPTER
5D90A 5.00" 8.00" 7.38" 7.38"
A
C
10.75
BA
CAT NO.4DVLTK
A B C4.00" 6.50" 7.28"
DIRECT VENT LINER KIT
CAT NO.4DVLA
A B C4.00" 6.50" 7.28"
C
10.75
BA
CO-AXIAL TO CO-LINEAR ADAPTER
CAT NO.4DV3A
A B2.90" 4.25"
A
B
0.50
CO-LINEAR FLEX CONNECTOR
EE
CAT NO.4D90L5D90L
A B C4.00"5.00"
6.50"8.00"
12.00"15.25"
D E F13.38"16.62"
6.13"7.75"
7.25"9.00"
E
FD
C
AB
90° SWIVEL ELBOW
CAT NO.4D90L5D90L
8DV90L
A B C
8.00" 11.00" 11.50" 12.75" 22.88" 24.38"
D E F
90° SWIVEL ELBOW
CAT NO.4D45L
A B C4.00"5.00"8.00"
6.50"8.00"11.00"
17.12"15.62"21.50"
D E F6.50"5.93"8.38"
4.50"4.50"6.00"
6.12"5.25"7.25"
5D45L8D45L
E
F
D
C
AB
45° SWIVEL ELBOW
CAT NO.4D45L
A B C D E F
5D45L8DV45L
45° SWIVEL ELBOW
FLEXIBLE CHIMNEY LINERS
CAT NO.FLX0325FLX0335
Size and identification3" Diameter x 25' length3" Diameter x 35' length
FLX0425 4" Diameter x 25' length
FLX0435 4" Diameter x 35' length
VERTICAL LINER TERMINATION14.0012.00
10.75
18.00 SQ.A2.75
CAT NO.4DVT33F
BA
4DVT43F
3.00"
4.00"
3.00"
3.00"
CAT NO.4DST145DST14
A B C4.00"5.00"
6.50"8.00"
D14.00"
4DST365DST36
4.00"5.00"
6.50"8.00"
14.00"36.00"36.00"
27.00"28.25"
50.25"49.00"
HOT
D
10.75
C
BA
4.00
SNORKEL TERMINATION
C
C 7.00 3.00
A B
CAT NO.4DHT5DHT
A B C4.00"5.00"
6.50"8.00"
13.50"16.00"
HORIZONTAL TERMINATION
HOT
CAT NO.4DHT5DHT
A B C
HORIZONTAL TERMINATION
HORIZONTAL TERMINATION
CAT NO.4DHT
A B C7.94" 11.11" 15.00" 15.00"
CAT NO.8DVHT
A B C D
A BC
D
CAT NO.4DHTE
A B C4.00" 6.50" 12.88" 11.00"
D
HORIZONTAL TERMINATION
5DHTE 5.00" 8.00" 15.00" 13.00"
D
C
9.38
BACAT NO.4DHTE
A B C D
ECONOMY HORIZONTAL TERMINATION
5DHTE
A B
B 0.25
DECORATIVE COVER PLATE
A BCAT NO.4DCP5DCP
6.64"8.16"
13.00"13.00"
CAT NO.4DVS5DVS
A B C6.75"8.25"
13.25"15.75"
17.50"19.88"
A
C
CB
1.88
VINYL SIDING STAND OFF
INSULATION SHIELD
A B C DCAT NO.8DVIS
AB
D
C
13.00" 16.00" 11.00" 12.00" to 22.00"
INSULATION SHIELD
18.00
B
A
A BCAT NO.4DIS5DIS
8.63"10.00"
17.00"19.00"
A
B
4.00 CAT NO.4DF-12
A B PLATE SIZE6.69"8.19"11.25"
12.50"18.00"22.75"
5DF-128DVF-12
21.00" x 28.00"21.00" x 28.00"30.75" x 28.00"
FLASHING
Fits roof pitch from 6/12 to 12/12
CAT NO.8DVVT
A B C8.00" 11.00"
D E11.63"13.50" 15.50"
AB
E
CD
VERTICAL TERMINATION
A
4.00
B
CAT NO.4DF
A B PLATE SIZE6.75"8.25"11.18"
9.50"11.00"14.63"
5DF8DVF
17.50" x 17.50"19.00" x 19.00"22.38" x 22.38"
FLASHING
Fits roof pitch from 1/12 to 5/12
CAT NO.4DVT
A B C4.00"5.00"
6.50"8.00"
D E10.00"10.00"
10.00"12.00"
12.00"14.00"5DVT
B
E
CD
A
E
VERTICAL TERMINATION
BA
C
CAT NO.4DFS5DFS
A B C6.56"8.06"
8.50"10.00"
10.50"13.00"
VERTICAL FIRESTOP
CAT NO.4DSPFS5DSPFS
A B C
VERTICAL SUREGRIP SUPPORT & FIRESTOP
BA
C
6.45"7.98"
8.50"10.00"
12.00"13.00"
A1.50
1.05
CAT NO.4DSC
A6.54"8.03"11.00"
5DSC8DVSC
STORM COLLAR
TALL CONE FLASHING
CAT NO.4DFT
A B PLATE SIZE6.60"8.10"
9.50"11.03"5DFT
17.50" x 17.50"19.00" x 19.00"
8DVFSV 11.13" 13.00" 16.00"
B
11.75
A
CAT NO.4DWT
A B8.69"10.18"
12.00"12.00"5DWT
4.00" x 6.50"4.00" x 6.50"
CBA
C
WALL THIMBLE
12
CAT NO.4DFSH5DFSH
8DVFSH
A B C D E
HORIZONTAL FIRESTOP
UP
A
B
C
D
E
1.00
6.75"8.25"
11.50"13.00"
13.50"15.00"
8.50"10.00"
10.50"12.00"
11.25" 16.00" 18.00" 13.00" 15.00"
CAT NO.4DWT11
A B8.69"10.18"
12.00"12.00"5DWT11
6.50" x 9.00"6.50" x 9.00"
C
WALL THIMBLE
BA
C
10.5010.50
15.00
PAINTED ROOF SUPPORT
Note: Trim plates and collar included as shown.
CAT NO.4DRS5DRS
13
A
B
CAT NO.4DSP5DSP
8DVSP
A B12.00"13.50"16.00"
17.00"17.00"16.00"
SUPPORT PLATE
A
18.00
SUPPORT STRAP
CAT NO.8DVSS
A11.00"
CAT NO.4DWS5DWS
A B6.63"8.06"
4.88"5.53"
A
B
WALL SUPPORT
14
VERTICAL INSTALLATION KIT
Flashing 1/12 - 5/12
Storm Collar
Vertical Termination
HORIZONTAL INSTALLATION KIT B
Decorative Cover Plate - Black
24" Straight Length - Black
Horizontal Termination
Wall Thimble
90° Elbow - Black
HORIZONTAL INSTALLATION KIT A
Horizontal Termination
Wall Thimble
90° Elbow
CAT NO.4DHTKA
CAT NO.4DHTKB
CAT NO.4DVTK
15
MASONRY CHIMNEY RELINE KIT
Vertical Termination
Dual 2-Ply 3" or 4" Flexible Aluminum Liners
2-Clamp Bands
Chimney Flashing - Flat
35' Flexible Liner Length
HORIZONTAL SLIP ADAPTER KIT
Adjustable Slip Connector
6" Straight Length
Horizontal Firestop
Adjustable Length
Economy Horizontal Termination
CAT NO.4DSLPHTK
CAT NO.4DVT33FK & 4DVT43FK
PREMIUM BIOMASS
BIOMASSAIR-COOLED TEMP/GUARD®
DAMPERS GRILLES & REGISTERS
CORR/GUARD®
TYPE-B GAS VENT FLEXIBLE CHIMNEY LINERS SOLID FUEL
Litho in U.S.A. ©2020 Metal-Fab, Inc. Form No. L2445-3/209977
A quality, complete line including2x2 and extruded aluminum.
Easiest installa�on on the market...featuringSureLock™ B-Vent Locking System.
Flexible liners, connectorsand relining kits.
Complete line of Solid Fuel Chimneyand Black Pipe.
For use with masonry fireplaceswhich burn wood, oil, coal or gas.
Designed for corrosive appliancesand exhaust systems.
Designed for use with pellet, cornor wheat-fired appliances.
Designed for use with pellet cornor wheat-fired appliances.
Full line of fire & ceiling radia�on dampers.Capacity to fill high volume orders 100%.