Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE...

8
Digital Implant No.1 Abutment Digital

Transcript of Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE...

Page 1: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Implant No.1

AbutmentDigital

Page 2: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

02 03

MORE developed thanthe Ready-made Abutments, MORE convenient thanthe Customized Abutments!

CEJ Cemento Enamel junctionDigital abutment was created based on the CEJ therefore has excellent esthetic appearance, and is healed more similar to a natural teeth due to its induction to sufficient gingiva adhesion.

Maxillary

Mandible

Molar

Premolar

CanineIncisor

Molar

Prem

olar

Canin

eInciso

r

A Clinical Application Example of Digital Abutment

An Abutment optimized for Immediate Loading during Flapless Surgery Modification possible during immediate loading even if the height of gingiva changes The convenience of not needing to detach the abutment up to the Final prosthetic placement after the Implant Surgery The possibility of Double Crown Technique in the case of Full mouth Flapless Surgery, within the range of errors

Prosthetic production process using Digital Abutment in DIOnavi Surgery

Page 3: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

02 03

Lower Incisor Upper Incisor Canine Pre-Molar Molar

Cross Section

Cervical MarginCross Section

Facial Side

Connection UF(II) Narrow UF(II) Narrow / UF(II) UF(II) UF(II) UF(II)

Cervical Margin Dimension (Mesiodistal x faciolingual)

5 X 5.2 6.1 X 5.7 5.3 X 6.3 5.8 X 6.8 7.3 X 7.8

Ratio (%) 70% 70% / 85% 85% 85% 85%

단면

치경부단면

디지털어버트먼트

LowerIncisor하악전치

UpperIncisor상악전치

Canine견치

Pre-Molar소구치칯

Molar대구치

L25

U25 C25

P25

M25

단면

치경부단면

디지털어버트먼트

LowerIncisor하악전치

UpperIncisor상악전치

Canine견치

Pre-Molar소구치칯

Molar대구치

L25

U25 C25

P25

M25

단면

치경부단면

디지털어버트먼트

LowerIncisor하악전치

UpperIncisor상악전치

Canine견치

Pre-Molar소구치칯

Molar대구치

L25

U25 C25

P25

M25

단면

치경부단면

디지털어버트먼트

LowerIncisor하악전치

UpperIncisor상악전치

Canine견치

Pre-Molar소구치칯

Molar대구치

L25

U25 C25

P25

M25

단면

치경부단면

디지털어버트먼트

LowerIncisor하악전치

UpperIncisor상악전치

Canine견치

Pre-Molar소구치칯

Molar대구치

L25

U25 C25

P25

M25

Scan Adapter Function

Protect Cap Lock-Groove

Marking

UF(II) Connection

Shoulder Margin

L25 · L Lower Incisor 2 Cuff Height 5 Post HeightU25 · U Upper Incisor 2 Cuff Height 5 Post HeightC25 · C Canine 2 Cuff Height 5 Post HeightP25 · P Pre-Molar 2 Cuff Height 5 Post HeightM25 · M Molar 2 Cuff Height 5 Post Height

Attention

0.5 unit marking exempted in accordance with marketingex) Cuff 2.5 = 2 / Post 5.5 = 5

UF(II) NarrowConnection

UF(II)Connection

Page 4: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

04 05

Lower Incisor

Upper Incisor

UF(II) Narrow Angled Abutment_Hex

UF(II) Narrow Angled Abutment_Hex

UF(II) Narrow Protect Cap

UF(II) Narrow Protect Cap

No. Code Cuff Post Marking

1 DLN 2555H 2.5

5.5

L252 DLN 3555H 3.5 L353 DLN 4555H 4.5 L454 DLN 5555H 5.5 L555 DLN 2570H 2.5

7.0

L276 DLN 3570H 3.5 L377 DLN 4570H 4.5 L478 DLN 5570H 5.5 L57

No. Code Cuff Post Marking

1 DUN 2555H 2.5

5.5

U252 DUN 3555H 3.5 U353 DUN 4555H 4.5 U454 DUN 5555H 5.5 U555 DUN 2570H 2.5

7.0

U276 DUN 3570H 3.5 U377 DUN 4570H 4.5 U478 DUN 5570H 5.5 U57

No. Code Post

9 DCLN 55 5.510 DCLN 70 7.0

No. Code Post

9 DCUN 55 5.510 DCUN 70 7.0

UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H

UF(II) Narrow Abutment Screw usedTightening torque : 20NcmOrder Code : UNSAS 1407H

Post

(5.5

)Po

st (5

.5)

Post

(7)

Post

(7)

Cuff

Cuff

Cuff

Cuff

3.47

3.64

4.13

3.99

UF(II) Narrow Screw

UF(II) Narrow Screw

D

C

Hex Non-Hex

D

C

L

Hex Non-Hex

FixtureLevel

FixtureLevel

Drill

33 / 8.5

33 / 10

33 / 11.5

33 / 13

L1 / L2 Dia.

DSU 2708M

DSU 2710M

DSU 2711M

DSU 2713M

Ø2.7L1 / L2

Starter Drill

30 / 15

Dia.

SD 1530M

Ø1.5 L1 / L2

Initial Drill

34.5 / 17.5

Dia.

DHF 2015SM

Ø2.0

8.57

DSU

2708

M

L2

0.5

L1

D

DSU

27xx

M

L1 / L2

Parallel PinD1 / D2 Ø2.0 / Ø2.7

22/10 PP 2022

PP 202323/16

1.2 Hex Screw Driver

16

20

Length Type Machine Ratchet

-

-

MD 1230

HD 1220A

L

L

L2

L1

D

L2

0.5

L1

D

Ø2.0

78.5

1011.5

1315

L1

L2

D1

D2

Hex 1.2

C

Apex Apex

Hex 1.7 Hex 1.7

L

Ø3.3Ø3.0

FixtureLevel

DHex 1.2

C

Diameter

Cuff/Height

H

0.5Ø4.2

C6H10

FixtureLevel

C

L

Hex Non-Hex

D

FixtureLevel

C

15°

Hex Non-Hex

D

FixtureLevel

C

L

FixtureLevel

Hex Non-Hex

D

L

D

Tap Drill

Code

Diameter

UNTD 3015 UNTD 3315

Ø3.0 Ø3.3

Fixture Driver

6

12

18

Length Type Machine Ratchet

Diameter

UNFDC 3006

UNFDC 3012

UNFDC 3018

UNFDW 3006

UNFDW 3012

UNFDW 3018

Ø3.0 / Ø3.3

Option) Available(별매품)

L

L

L

D

D

D

CFixtureLevel

D

Torque Wrench

*Bottom Case

DTW 0060

8.5 / 10 / 11.5 / 13 / 15 / 18

Depth Gauge DPG 2050

D

D

C

L

FixtureLevel

1.2 Hex

L

D

L

D

L

D

L2

L1

D

L2

0.5

L1

D

Ø2.0

78.5

1011.5

1315

L1

L2

D1

D2

8.57

DSU

2708

M

L2

0.5

L1

D

DSU

27xx

M

L

L

D

C

Hex Non-Hex

D

C

L

Hex Non-Hex

FixtureLevel

FixtureLevel

Drill

33 / 8.5

33 / 10

33 / 11.5

33 / 13

L1 / L2 Dia.

DSU 2708M

DSU 2710M

DSU 2711M

DSU 2713M

Ø2.7L1 / L2

Starter Drill

30 / 15

Dia.

SD 1530M

Ø1.5 L1 / L2

Initial Drill

34.5 / 17.5

Dia.

DHF 2015SM

Ø2.0

8.57

DSU

2708

M

L2

0.5

L1

D

DSU

27xx

M

L1 / L2

Parallel PinD1 / D2 Ø2.0 / Ø2.7

22/10 PP 2022

PP 202323/16

1.2 Hex Screw Driver

16

20

Length Type Machine Ratchet

-

-

MD 1230

HD 1220A

L

L

L2

L1

D

L2

0.5

L1

D

Ø2.0

78.5

1011.5

1315

L1

L2

D1

D2

Hex 1.2

C

Apex Apex

Hex 1.7 Hex 1.7

L

Ø3.3Ø3.0

FixtureLevel

DHex 1.2

C

Diameter

Cuff/Height

H

0.5Ø4.2

C6H10

FixtureLevel

C

L

Hex Non-Hex

D

FixtureLevel

C

15°

Hex Non-Hex

D

FixtureLevel

C

L

FixtureLevel

Hex Non-Hex

D

L

D

Tap Drill

Code

Diameter

UNTD 3015 UNTD 3315

Ø3.0 Ø3.3

Fixture Driver

6

12

18

Length Type Machine Ratchet

Diameter

UNFDC 3006

UNFDC 3012

UNFDC 3018

UNFDW 3006

UNFDW 3012

UNFDW 3018

Ø3.0 / Ø3.3

Option) Available(별매품)

L

L

L

D

D

D

CFixtureLevel

D

Torque Wrench

*Bottom Case

DTW 0060

8.5 / 10 / 11.5 / 13 / 15 / 18

Depth Gauge DPG 2050

D

D

C

L

FixtureLevel

1.2 Hex

L

D

L

D

L

D

L2

L1

D

L2

0.5

L1

D

Ø2.0

78.5

1011.5

1315

L1

L2

D1

D2

8.57

DSU

2708

M

L2

0.5

L1

D

DSU

27xx

M

L

L

Page 5: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

04 05

Upper Incisor

Canine

UF(II) Angled Abutment_Hex

UF(II) Protect Cap

No. Code Cuff Post Marking

1 DUR 2555H 2.5

5.5

U252 DUR 3555H 3.5 U353 DUR 4555H 4.5 U454 DUR 5555H 5.5 U555 DUR 2570H 2.5

7.0

U276 DUR 3570H 3.5 U377 DUR 4570H 4.5 U478 DUR 5570H 5.5 U57

UF(II) Angled Abutment_HexNo. Code Cuff Post Marking

1 DCR 2555H 2.55.5

C252 DCR 3555H 3.5 C353 DCR 2570H 2.5

7.0C45

4 DCR 3570H 3.5 C55

No. Code Post

9 DCUR 55 5.510 DCUR 70 7.0

UF(II) Protect CapNo. Code Post

9 DCCR 55 5.510 DCCR 70 7.0

Post

(5.5

)Po

st (7

)Cu

ffPo

st (5

.5)

Cuff

Cuff

Post

(7)

Cuff 4.49

5.27

5.11

4.85

UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

Page 6: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

06 07

Pre-MolarUF(II) Angled Abutment_Hex

No. Code Cuff Post Marking

1 DPR 1540H 1.5

4.0

P142 DPR 2540H 2.5 P243 DPR 3540H 3.5 P344 DPR 4540H 4.5 P445 DPR 1555H 1.5

5.5

P156 DPR 2555H 2.5 P257 DPR 3555H 3.5 P358 DPR 4555H 4.5 P45

UF(II) Protect CapNo. Code Post

9 DCPR 40 4.010 DCPR 55 5.5

MolarUF(II) Angled Abutment_Hex

No. Code Cuff Post Marking

1 DMR 1540H 1.5

4.0

M142 DMR 2540H 2.5 M243 DMR 3540H 3.5 M344 DMR 4540H 4.5 M445 DMR 1555H 1.5

5.5

M156 DMR 2555H 2.5 M257 DMR 3555H 3.5 M358 DMR 4555H 4.5 M45

UF(II) Protect CapNo. Code Post

9 DCMR 40 4.010 DCMR 55 5.5

Post

(4.0

)Po

st (4

.0)

Post

(5.5

)Po

st (5

.5)

Cuff

Cuff

Cuff

Cuff

6.29

6.14

5.78

4.84

UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

UF(II) Regular ScrewTightening torque : 30 ~ 35NcmOrder Code : DASC 2008HCaution This screw is only for Digital Abutment which is not compatible with other screws or abutments.

Page 7: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

Digital Abutment Product Catalog Digital Abutment

06 07

The Advantages of Digital Abutment

Digital Abutment Workflow

In the case of Immediate Loading, it is possible to instantly choose the abutment based on the patients’ oral environment.

The prosthetic production time for the Digital Abutment is reduced because it doesn’t need to go through the Milling and CAD process due to its data in the Digital Library.

Taking the Digital Impression is very convenient for the Digital Abutment because it functions as a Scan adaptor and there is no need to take the exact impression up to the margin because its’ data is stored in the Digital Library.

DIOnavi.

Scanning

Image taking

Image taking

Implant Planning

Matching Software

Production

1) CT shooting2) Trios or Plaster model scan

1) Implant Procedure2) Digital Abutment Placement3) Trios or Plaster model scan

1) CT and Trios Scan Data matching2) Provisional crown design3) Implant planning4) Guide stent design

1) Trios Scan data and Digital Abutment Library Matching2) Crown Design3) Prosthetic Production

1) Guide stent production2) Digital Abutment Library Matching3) Provisional crown Production (Abutment JIG)

T IP

In the case where the fixture implantation depth does not match the planning depth due to change of operation environment during surgery- It is possible to choose the different height cuffs of Digital Abutment.- The provisional Crown that is custom fitted to the DA can be used as it is even if the cuff changes and it can be modified on the field but if there is too much height difference, it should be remanufactured.- If not using the Provisional crown, healing can be induced by attaching a protect cap.

Page 8: Digital Abutment · 2019-06-28 · Digital Abutment Product Catalog Digital Abutment 02 03 MORE developed than the Ready-made Abutments, MORE convenient than the Customized Abutments!

DIO Implant 66, Centum seo-ro, Haeundae-gu, Busan 612-020, Korea Tel +82 51 745 7777 Fax +82 51 745 7778 www.dioimplant.com