2
2016© Yamabiko Corporaon All rights reserved 35 Shin-Ujiagmi, Kita-Hiroshima-Cho, Yamagata-Gun, Hiroshima 731-1597 Japan http://www.yamabiko-corp.co.jp/shindaiwa_global/ipe/ Containment to prevent leakage of fuel and oil REALDUAL Welding Mode CC/CV Welding Mode Max open circuit voltage CC/CV/Droop Welding mode selector Voltage regulaon device Definion of the icons OCV 85 V Engine Powered by Construcon Civil Engineering Pipe Line Rental Fabricaon Offshore Mining Repair Farming Maintenance Rail Road Service Truck CC Mode Standard Rod Cellulose Rod Scratch TIG Gouging up to 8.0mm Excellent Good Excellent Standard Good CV Mode Flux-cored Wire Welding Process Specificaon AC Generator Welding DC Generator Dimensions (L)1435 x (W)700 x (H)848 Overall Dimensions (mm) Dry Weight (Kg) 453 Dual Power Factor Field of Applicaon 100% MAX85V Dual 180 / 200A No Load Voltage (OCV) Duty Cycle Rated Voltage Rated Current 20.0 / 21.0V 31.5 / 32.0V Single 100% 330 / 340A CV 50-200 / 60-210A 180 / 200A Current Adj. Range Duty Cycle Rated Voltage Rated Current 27.2 / 28.0V 34.8 / 35.5V Single 100% 60% 370 / 390A CC Droop 95-390 / 110-400A Φ3.2-5.0mm Gouging Rod Welding Rod Capacity Φ2.0-4.0mm Φ3.2-8.0mm 14-21.0 / 14.5-23.5A Current Adj. Range 14-34.5 / 14.5-35A Φ2.6-8.0mm Wire Size 0.6-2.0mm 0.6-1.6mm Noise Level 64/65 dB(A) Lowest @7m/idle Rated Frequency Rated Voltage Single Phase Rated Output 50 / 60 Hz 110 / 115V 230 / 240V 1.0 3.3 -3.5kVA 6.9 / 7.2kVA Kubota D902 Model Vercal, Water-cooled, 4 cycle diesel 15.0 / 3,000 Rated Output (kW/min-1) 37 L 0.898 L Engine Type Displacement Fuel Tank Capacity 17.6 / 3,600 Diesel Engine Driven Welder & Generator DGW400DMK-S2V E160831

Transcript of Diesel Engine Driven Welder & Generator DGW400DMK-S2V...reducing noise, exhaust gas emission, and...

Page 1: Diesel Engine Driven Welder & Generator DGW400DMK-S2V...reducing noise, exhaust gas emission, and saving fuel consumption. 10. VRD Switch 18. Welding Terminal B 17. Welding Terminal

2016© Yamabiko Corporation All rights reserved35 Shin-Ujiagmi, Kita-Hiroshima-Cho, Yamagata-Gun, Hiroshima 731-1597 Japan

http://www.yamabiko-corp.co.jp/shindaiwa_global/ipe/

Containment to prevent leakage of fuel and oil

REALDUAL Welding Mode CC/CV Welding Mode Max open circuit voltage

CC/CV/Droop Welding mode selectorVoltage regulation device

Definition of the iconsOCV

85V

EnginePowered by

Construction Civil EngineeringPipe Line Rental FabricationOffshoreMining Repair FarmingMaintenanceRail Road Service Truck

CC Mode Standard Rod Cellulose Rod Scratch TIG Gouging up to 8.0mm

Excellent

GoodExcellent Standard

Good

CV Mode Flux-cored Wire

Welding Process

SpecificationAC GeneratorWelding DC Generator

Dimensions(L)1435 x (W)700 x (H)848Overall Dimensions (mm)

Dry Weight (Kg) 453

Dual

Power Factor

Field of Application

100%

MAX85V

Dual180 / 200A

No Load Voltage (OCV)

Duty CycleRated VoltageRated Current

20.0 / 21.0V31.5 / 32.0V

Single

100%

330 / 340ACV

50-200 / 60-210A

180 / 200A

Current Adj. RangeDuty CycleRated VoltageRated Current

27.2 / 28.0V34.8 / 35.5V

Single

100%60%

370 / 390ACC Droop

95-390 / 110-400A

Φ3.2-5.0mmGouging RodWelding Rod Capacity Φ2.0-4.0mm

Φ3.2-8.0mm

14-21.0 / 14.5-23.5ACurrent Adj. Range 14-34.5 / 14.5-35A

Φ2.6-8.0mm

Wire Size 0.6-2.0mm 0.6-1.6mm

Noise Level64/65 dB(A)Lowest @7m/idle

Rated Frequency

Rated Voltage Single Phase

Rated Output50 / 60 Hz

110 / 115V 230 / 240V1.0

3.3 -3.5kVA 6.9 / 7.2kVA

Kubota D902ModelVertical, Water-cooled, 4 cycle diesel

15.0 / 3,000Rated Output (kW/min-1)37 L

0.898 LEngine TypeDisplacement

Fuel Tank Capacity17.6 / 3,600

Diesel Engine Driven Welder & Generator DGW400DMK-S2V

E160831

Page 2: Diesel Engine Driven Welder & Generator DGW400DMK-S2V...reducing noise, exhaust gas emission, and saving fuel consumption. 10. VRD Switch 18. Welding Terminal B 17. Welding Terminal

2016© Yamabiko Corporation All rights reserved35 Shin-Ujiagmi, Kita-Hiroshima-Cho, Yamagata-Gun, Hiroshima 731-1597 Japan

http://www.yamabiko-corp.co.jp/shindaiwa_global/ipe/

DGW400DMK-S2V

Diesel Engine Driven Welder & Generator

Product Features

AC OUTPUT PANEL

SUPER QUIET

Our design is more responsive to protect nature. New features are incorporated to follow environmental regulations.● A factory-equipped spill containment, keeps fuel, oil, and coolant inside to avoid   discharging to the ground.● An unique ventilation hole will guide trapped rain water outside the spill containment and  drain it separately.

Thanks to skillfully designed airflow, the equipment achieves Super Quiet operation. This means that the working unit does not interrupt conversation between operators.

The engine speed optimization function enables the engine to operate at an optimal speed corresponding to the weld output, thereby reducing noise, exhaust gas emission, and saving fuel consumption.

10. VRD Switch

18. Welding Terminal B17. Welding Terminal A

2. AC Meter3. AC Meter Selector4. Emergency Stop Switch5. DC Welding Current Meter6. Single/Dual Selector Switch7. Output Control Dial8. Weld Mode Selector9. Arc Force Adjusting Dial

11. Idle Control Switch12. Starter Switch Key13. Warning Monitor Lamp14. Hour Meter

16. Remote Control Receptacles15. Fuel Meter

19. 1-Phase 230/240V Receptacle (IP44)20. 1-Phase 110/115V Receptacle (IP44)21. 1-Phase 230/240 V Breaker22. 1-P 110V/115V Breaker23. Earth Leakage Circuit Breaker (ELCB)24. Bonnet Grounding Terminal

1. ECO Mode Display

Shindaiwa’ s alternator is unique in coil winding. Welding power A, B, and AC generator are respectively driven by each coil winding. This feature ensures that each welding outputs has no electrical interference.

Special varnished reliable Shindaiwa’ s alternator, offers robust features of protection against sand gravel, dust, and extreme hot weather condition.

12

3

4

5

677

88

9

21

9

10 11 12 13

14 15

16

17 18

19

20 22 2423

Control Panel

WELDING MODE

ECO MODEROBUST ALTERNATOR

SPILL CONTAINMENT/RAIN WATER PROTECTION

5