Diamagnetic Therapy Diathermy Self Adjusted System

57
Diamagnetic Therapy Diathermy Self Adjusted System Treatments using DIAMAGNETIC THERAPY and DIATHERMY SELF ADJUSTED SYSTEM Notes on the clinical aspects and practice

description

Notes on the clinical aspects and practice. Diamagnetic Therapy Diathermy Self Adjusted System. Treatments using DIAMAGNETIC THERAPY and DIATHERMY SELF ADJUSTED SYSTEM. Practice in Diamagnetic Therapy - PowerPoint PPT Presentation

Transcript of Diamagnetic Therapy Diathermy Self Adjusted System

Page 1: Diamagnetic Therapy Diathermy Self Adjusted System

Diamagnetic Therapy

Diathermy Self Adjusted System

Treatments using

DIAMAGNETIC THERAPY

and

DIATHERMY SELF ADJUSTED SYSTEM

Notes on the clinical aspects and practice

Page 2: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Diamagnetic Therapy

Practice in Diamagnetic Therapy

An appropriate approach to the Diamagnetic treatments is

determined by rules knowledge of general methodology,

Therefore, it is very important to have some knowledge and some experiences to make all operation phases of treatment correctly and to obtain maximum therapeutic advantage for each client and each pathology.

Page 3: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Common working procedure foreseen 6 substantial activities in the preliminary treatment :

1 Verify the contra indication to the treatment

2 Prepare the patient

3 Identify the Neutral Cream

4 Select working system using the neutral plate whether it is a single or double neutral system

5 Identify the medicine classes uses in the Molecular Implant

6 Identify the sequences of operation from the available action mechanism

Page 4: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Contra indications to treatment

Before you make a treatment, it is always useful to understand the contra indications to treatment.

Absolute contra indications to treatment: Cardiac Pace Maker carriersPregnant womenTumor Epiphysis fertileNeoplasm

Further on, you must perform a preliminary medical history of the patient in order to detect: unsuitable physiological status such as the presence of ferromagnetic in the body under treatment.

Page 5: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Verification procedure

Verification procedure is useful for verifying and confirming the possibility of prosthesis type in the area which will be treated by diamagnetic.

The procedure is through the approaching of an electrode with metallic prosthesis to verify in adequate status or less.

Page 6: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Intolerance to treatments

There is no particular intolerance or manifestation, such as allergy, in diamagnetic therapy session. The actual problems usually happen or appear due to the use of medicine products in the treatment using Diamagnetic. Other possibility could be the over dosage of medicine.

Page 7: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Preparation of Patient

BED:

It is recommended to use the isolated beds or type of treatment beds that do not have the metal part even if it is not prescribed for not using it. This precaution is useful to prevent alternated electrical current during the treatment.

However, if it is possible that the patient does not

touch any metal part that is exposed during the treatment and that this kind of conduction is not exist, the precaution is excluded.

Page 8: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

CREAM

The option of conductor cream must be done according to the following criteria: if you do not use a product with active principle which then binds us in a particular reaction, you have to use a neutral cream that should have several criteria.

Neutral Cream:• They must satisfy the electrical conductibility requirement. • They must not be electrolyzed at the strong and dense current. • They must not have incompatible pH with the electrodes that

you use.• They must have a slow absorbance character for lasting sliding• They must have a monitored value of kinematic viscosity and

dynamic • The thickness and whole structure of cream must be

maintained the same even when the temperature is more than 40°C.

Page 9: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Single and Double Return Plate Method

Return plate is necessary to close the current towards the generator during the treatment.

In Diamagnetic Therapy, the return plate is used only if you would like to use as well the Radio Frequency in the treatment.

The position of the neutral plate must be chosen strategically due to their influence in the treatment results.

In positioning the return plate, you should keep the consideration as following: the plates must be positioned in the part of body that is less sensitive and has a large area, this is to reduce the thermal effect.

Further on, they must guarantee that the current path should be as short as possible hence affect all tissues during the treatment.

Example for the plates positions

Page 10: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

The use of Double neutral plates is useful to obtain:

• Energy Balance

• Expansion of energy area

• Homogenous of emission

Double Neutral Method

Page 11: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Energy Balance

It means a symmetric emission of radio frequency, it is very useful in case of treating specific areas of body such as the back.

Active Electrode

2 neutral plates on thigh

Page 12: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Expansion of Energy Area

Expansion of energy area allows reducing the treatment time in case you should make treatment on the big area.

For example, to treat a whole leg, you should place these double return plate as indicated in the figure, it allows to emit the energy in all area without a necessity to move the return plate. It will receive the same energy in all area between two return plates.

Neutral plate behind the thigh

Page 13: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Homogenous of emission

Homogenous of emission is an applicative method which is very common to use to keep the homogenous of energy emitted in the tissue without having a risk that only several parts of body receive more energy than the others (that close to the return plate having more energy) as happened with the other classical method.

With two return plates, the energy transmission is the same in all treated area.

The heat, therefore the energy, is bigger in the area near to the return plate and it tends to lessen when it get far away from the return plate.

1 return plate

2 return plates

Page 14: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

In Endogenous Stimulation program, we insert the program

PAIN CONTROL

This program is specifically made for the analgesic therapy.It uses the frequency below 300 KHz. For example 200 – 250 KHz reacts and stimulates the nerves ending, making it larger and make the analgesic effect more immediate.

Pain control

Page 15: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Molecular Implant

• Term of medicine application If the medicine is in the cream or gel form and it uses directly in the area that is treated.If the medicine is in the liquid form, the procedure provides the use of gauze or hydrofoil cotton disc with the substance. The tissue, then, is positioned on the treated area and the handle is positioned on the gauze.

• Stratification of pharmacologyThe stratification of medicine can be done with an orderly selection of medicine that you like to penetrate in the depth layer of the tissue, therefore from the depth to the superficial tissue. It is possible to penetrate also the mixture of medicine in case you consider it useful.

Page 16: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

The penetrable medicine are all substances which has the active principle with diamagnetic property.

The medicine that does not have diamagnetic property can use the water (or a gel), using it like a vector to transport the molecule in the tissue layer .

The parameterization is carried out based on the implant depth, molecular dimension and implant speed

Atom Weight of Molecular

Repetition Frequency

Implant Depth

Page 17: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

TABLE OF OTHER ACTIVE PRINCIPLE WITH DIAMAGNETIC PROPERTY

ACTIVE VASE

Active Principl

e

Commercial Name

Property Molecular Weight

Water-Soluble

CTU Parameterisati

on

Buflomdil Loftyl Active Vase Yes 400 PA

Sulodexide Wessel-Due.F Fibronolitico Yes 400 PA

Page 18: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

NSAID

Active PrincipleCommercial

NameProperty

Molecular Weight

Water-Soluble CTU Parameterisation

Diclofenac Voltaren Anti-Inflamatory 296.148 u.m.a Yes 400 PA

Piroxicam Feldene Anti-Inflamatory 331,348 u.m.a Yes 400 PA

Ketoprofene Flezen Anti-Inflamatory 146,16 Yes 200 PA

Ketolorac Artrosilene Anti-Inflamatory Yes 400 PA

CORTISONE

Active PrincipleCommercial

NameProperty

Molecular Weight

Water-Soluble

CTU Parameterisation

Hydrocortisone Flebocortid Anti-Inflamatory 349 u.m.a Yes 400 PA

Prednisone Acetate Merticortelone Anti-Inflamatory 360.444 u.m.a Yes 400 PA

Betametasone Celestine Anti-Inflamatory Yes 400 PA

Desametasone Soldesan Anti-Inflamatory Yes 400 PA

Page 19: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

C

P

C

P

Standard device CTU Mega 18 Standard device CTU Mega 18

C= Concentration of active principle

P= Implant depth

C= Concentration of active principle

P= Implant depth

Page 20: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Action Mechanism Sequences

How to choose the operation sequences of action mechanism

Which pharmacology that can be used

When to use contemporarily the diathermy

Page 21: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

How to choose the operative sequence: the concept of evolutionary therapy

Diamagnetic therapy allows to use 4 specific programs to produce specific action mechanism in the tissue:

Liquid Movement

Endogenous Stimulation

Pain ControlIn section of Endogenous Stimulation

Molecular Implant

Page 22: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

General Guide Line

If you would like to treat an acute pathology with diffused edema, it is recommended to proceed the treatment with drainage phase

Whether there is trauma on the muscle system (causing the immobility: former casts), it is possible to end the treatment with an endogenous stimulation phase with selecting the target: CELL

Whether our interest is not to drain but rather directing the liquid in the treated area, it is possible to work with drainage program on the distal area and afterwards carry out the treatment

If it is necessary to reduce the pain without using the medicine, you could use the Pain Control mechanism + diathermy

Whenever you want to favoring the molecular implant, it is recommended to make a treatment with drainage phase for 5 minutes

The activity order selection comes before other general rules that connected to the evolutionary therapy concept:

Page 23: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Liquid Movement + Endogenous Stimulation

Liquid Movement + Endogenous Stimulation PAIN CONTROL

Liquid Movement + Endogenous Stimulation + PAIN CONTROL

Molecular Implant

Liquid Movement + Molecular Implant

Option 1

Option 2

Option 3

Option 4

Option 5

Page 24: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Diamagnetic Therapy and diathermy

• When you use it together

• Why you use it together

Page 25: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Energy transfer system for capacitive and resistive diathermy

Diathermy is an energy transfer technique with resistive and capacitive mode.

It produces heat in the living tissue, provoke an augment of heat whether in the depth as well in the superficial layer.

Between these heat effects and of bio-stimulation consequences, first of all is the vasodilatation, a condition that characterized by an augment of blood flow in the blood vases, that intensify the blood circulation in the interested area in the treatment and generally, contribution of extra cell liquid.

capacitive

resistive

Page 26: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

In normal operation condition, the liquid movement induced in the diathermy process suffers a setback. Indeed, following the blood flow, the liquid accumulation becomes more predominant, continuous to increase due to the equilibrium pressure that are established at the cell level and for the physical limit of mechanical confinement of external compartment.

Liquid accumulation following the blood flow. Not having the possibility to be drained, the liquid fluxes is blocked

Page 27: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

To maintain the effects of diathermy, we use the combination with Diamagnetic Pump:

Indeed the repulsion force, thanks to the diamagnetic field, enhances the drainage effect determined by the diathermy, inducing the liquid movement and removal from the tissue with vasodilatation The result is an active diathermy mechanism without the setback and intensification of the already therapeutic property induced by an exclusive use of diathermy, enhancing its anti-inflammatory properties as well as rehabilitation

Diathermy mechanism without set back, thanks to the drainage activity

of DIA field

Page 28: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Reading system, registration and print out of the body impedance purpose to :

Register the variation of tissue

impedance during the treatment

Allow to monitor the progress of treatment

Allow to evaluate the benefits of carried out treatments

Page 29: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Disorders related to orthopedics and sports medicine

Arthritis Muscle pathologyTendon pathologySpine pathologyFractureSprains ContusionsRheumatologyOther pathologies

Page 30: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Application Method

Protocols

Page 31: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total treatment time : 20 minutesMinimum number of treatment : 5 -10

Phase 1 Liquid Movement

5’ parameterization (surrounding areas) : 20% intra 80% extra5’ parameterization at the localized area: 20% intra 100% extraIt is recommended to use the diathermy in

capacitive/resistive mode

Phase 2 Endogenous Stimulation

10’ with target: CELL Power stimulation: 4

Arthritis

Page 32: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Phase 1 Liquid Movement

5’ parameterization (localized) 80% intra 80% extra

It is not recommended the use of diathermy

Phase 2 Endogenous Stimulation

25’ with target: Cell stimulationPower stimulation 3/4

Fracture

Total time treatment in each session: 30minMinimum number of treatment: 8-12

Page 33: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20 minMinimum number of treatment : 7-10

Phase 1 Liquid Movement

10’ parameterization (localized) 80% intra 60% extra

It is recommended to use the diathermy in capacitive/resistive mode

Phase 2 Endogenous Stimulation

10’ with target: striate musclePower stimulation: 4

Contracture

Page 34: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

10’ parameterization (localized) 80% intra 80% extra

It is not recommended to use the diathermy

Phase 2 Endogenous Stimulation

10’ with Target: striate musclePower Stimulation 3/4

Muscle Injuries

Page 35: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 25 mins Minimum number of treatment : 7-10

Phase 1 Liquid Movement10’ parameterization60% intra 60% extra

Phase 2 Endogenous Stimulation 10’ with target : cell membranePower stimulation 4

The treatment is ended with a phase of PAIN CONTROL for 5’ combined with diathermy capacitive

Fibromyalgia

Page 36: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment is each session: 25minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

10 ’ parameterisation 40% intra 40% extra

Phase 2 Endogenous Stimulation

10’ with target: Cell Power Stimulation: 4

The treatment is terminated with a phase ofPAIN CONTROL for 5’

Sciatica

Low back pain

Lombocrualgia

It is recommended the use of capacitive / resistive diathermy

Page 37: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 60% extra

Fase 2 Endogenous Stimulation

10’ with target: CellPower Stimulation: 4

The treatment is terminated with a phase ofPAIN CONTROL for 5’

Lombalgia

It is recommended to use the capacitive/resistive diathermy

Page 38: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 30minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

10 ’ parameterisation 80% intra 100%extra

Phase 2 Endogenous Stimulation

15’ with target: Slow fibre Power Stimulation: 3 / 4

The treatment is ended with a phase of PAIN CONTROL for 5’

Disc Hernia

It is recommended to use capacitive / resistive diathermy

Page 39: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Periostosis

Fase 1 Liquid Movement

10 ’ parameterisation 60% intra 60%extra

Phase 2 Endogenous Stimulation

15’ target: CellPower Stimulation: 4/5

The treatment is ended with a phase of PAIN CONTROL for 5’ – power 4

It is recommended to use resistive diathermy

Total time of treatment in each session: 30minMinimum number of treatment: 8-12

Page 40: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Phase 1 Liquid Movement

10 ’ parameterisation 60% intra 80% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

Discopathy

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Page 41: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 8-12

Phase 1 Liquid Movement

5 ’ parameterisation 40% intra 80% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

The treatment is ended with a phase of PAIN CONTROL for 5’

Periarteritis

It is recommended to use capacitive / resistive diathermy

Page 42: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase Liquid Movement

20 ’ parameterisation 40% intra 80% extra

Skin Contusion

It is recommended to use the capacitive / resistive diathermy

Page 43: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 100% extra5’ parameterisation 100% intra60% extra

Phase 2 Endogenous Stimulation

10’ target: nerve cell slow fiber Power Stimulation: 3

Contusioni Muscolari

It is recommended to use the capacitive diathermy

Page 44: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

10 ’ parameterisation 80% intra 20% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3

Tendinitis and Articular Contusion

It is recommended to use resistive diathermy

Page 45: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

10’ parameterisation 100% intra 40% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3

Bones Contusion

It is recommended to use resistive diathermy

Page 46: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 60% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation 3 / 4

The treatment is ended with a phase of PAIN CONTROL for 5’

Epicondylitis

Epitrochleitis

It is recommended to use resistive diathermy

It is recommended to use XP Laser 4 level together with CTU Mega 18

Page 47: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 25minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 80% extra

Phase 2 Endogenous Stimulation

15’ target: CellPower Stimulation: 4

The treatment is ended with a phase of PAIN CONTROL for 5’

Brachialgia

Page 48: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

5 ’ parameterisation 40% intra 80% extra

Fase 2 Endogenous Stimulation

10’ target: CellPower Stimulation 3 / 4

The treatment is ended with a phase of PAIN CONTROL for 5’

Groin

Page 49: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

10 ’ parameterisation 20% intra 80% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

Crualgia

It is recommended to use resistive diathermy

Page 50: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

10 ’ parameterisation 40% intra 80% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3

Distortions

I grade

It is recommended to use capacitive / resistive diathermy

Page 51: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 100% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

The treatment is ended with a phase PAINCONTROL for 5’

Distortions

II e III grade

Page 52: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

15 ’ parameterisation 80% intra 80% extra

Phase 2 Endogenous Stimulation

5’ target: CellPower Stimulation: 4

Bursitis

Page 53: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 5-7

Phase 1 Liquid Movement

5 ’ parameterisation 80% intra 80% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation 3 / 4

Achilles Tendonitis

The treatment is ended with a phase PAIN CONTROL for 5’

Page 54: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Total time of treatment in each session: 20minMinimum number of treatment: 7-10

Phase 1 Liquid Movement

5 ’ parameterisation 60% intra 60% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

Carpal Tunnel

Syndrome median nerve of carpal

Neuroma

The treatment is ended with a phase PAIN CONTROL for 5’

Page 55: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Phase 1 Liquid Movement( first 2 session of treatment)10 ’ parameterisation 80% intra 80% extra

Phase 2 Endogenous Stimulation (first 2 session of treatment)

10’ target : CellPower Stimulation: 3 / 4

Dupuytren

Syndrome

Total time of treatment in each session: 20minMinimum number of treatment: 6-10

It is recommended to use the capacitive diathermy

(subsequent sessions of treatment)Phase 1 – Liquid Movement5 ’ parameterisation60% intra 60% extraNote: based on the improvement20% intra 40% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3 / 4

Phase 3- after the first 2 session 5 ’ pain control

Page 56: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Phase 1 Liquid Movement

5 ’ parameterisation 20% intra 60% extra

Phase 2 Endogenous Stimulation

10’ target: CellPower Stimulation: 3

It is recommended to use capacitive diathermy

Sinusitis

Total time of treatment in each session: 15minMinimum number of treatment: 4-5

Page 57: Diamagnetic Therapy Diathermy Self Adjusted System

Corso ECM – Educazione continua in medicina 2010

Working Environment

The CTU-Mega 18 Diamagnetic Pump can be used in different working environment:

Outpatient

Physiotherapy

Hospital