Page 1: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Diagnostic Diagnostic Laboratory Laboratory ProceduresProcedures

Page 2: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Microscope UseMicroscope Use• Objective lenses 4x, 10x, and Objective lenses 4x, 10x, and

40x40x• Oil-immersion is used Oil-immersion is used

occasionallyoccasionally• A mechanical stage is necessary A mechanical stage is necessary

to view slides thoroughlyto view slides thoroughly

Page 3: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Microscope UseMicroscope Use

• Viewing area = fieldViewing area = field

Page 4: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Microscope UseMicroscope Use• To scan a slide use 4x to To scan a slide use 4x to

focus, then move to 10xfocus, then move to 10x

• Scan back and forth Scan back and forth overlapping each fieldoverlapping each field

Page 5: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Microscope UseMicroscope Use

Scanning patternScanning pattern

Page 6: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Microscope UseMicroscope Use• Debris can be closely Debris can be closely

examined under high examined under high powerpower

Page 7: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Sample Collection• The animal owner will

most often collect the stool sample.

Page 8: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Sample Collection• The sample should be

fresh since some parasite eggs become unrecognizable as the feces ages.

Page 9: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Sample Collection• If a fresh sample cannot

be obtained, one can be refrigerated, but for no longer than 24 hours.

Page 10: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods1. Gross exam

- used to observe outward characteristics of the sample.

Page 11: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods1. Gross exam

- Several abnormalities can be seen with the naked eye.

Page 12: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods1. Gross exam

- observe and record• color and consistency• blood and mucus• age of sample• presence of adult parasites

Page 13: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods

2. Direct smear

- the fastest and simplest method of diagnosing parasitism.

Page 14: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods2. Direct smear

- A small amount of feces is mixed with water and applied directly to a slide.

Page 15: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods2. Direct smear

- The main disadvantage of this technique is that a

small sample may not contain any parasite eggs.

Page 16: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods2. Direct smear

- This method also leaves debris on the slide.

Page 17: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods3. Floatation

- the most commonly used procedure for diagnosing parasitism.

Page 18: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods3. Floatation

- techniques using this method:

- simple floatation

- use of a centrifuge

- Fecalyzer

Page 19: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods3. Floatation

Fecalyzer- uses a solution (zinc sulfate or sodium nitrate) that has a specific gravity greater than the specific gravity of most parasite eggs

Page 20: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods4. Sedimentation

- is commonly used for eggs that have a high specific gravity

Page 21: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods4. Sedimentation - The high specific gravity

of these eggs makes it difficult to use floatation techniques without

distorting them.

Page 22: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Methods4. Sedimentation

- Sedimentation allows eggs to sink to the bottom.

Page 23: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Debris

• may be easily confused with parasite eggs.

Page 24: Diagnostic Laboratory Procedures. Microscope Use Objective lenses 4x, 10x, and 40xObjective lenses 4x, 10x, and 40x Oil-immersion is used occasionallyOil-immersion.

Common Debris:• hair• plant material• air bubbles

•fat

•epithelial cells

•pollen grains