DI-60 Body Fluid SoftwareBody Fluid Application
The DI-60™ Body Fluid Application automatically performs a preliminary differential of nucleated cells and creates a digitized image of the entire sample area, for cyto-centrifuged preparared slides. Cells can be easily dragged and dropped into the appropriate cell class.
Regions of Interest (ROI) may be tagged, comments added and images stored and shared anywhere on a network. Access to a patient’s historical images and real time collaboration ensures accuracy and promotes standardization of analysis.
Sysmex DI-60Body Fluid Application
Body Fluid OptionKey Features & Benefits
• Designedtoutilizecyto-centrifugedpreparedslides
• Pre-classificationof7WBCclasses
• Viewcellclassessidebysideorinfullscreenview
• Digitallyscansentiresmeararea
- Simplenavigationinsampleoverviewarea
- Availablein10xor50xmagnification
• RegionsofInterest
- Tagareasforpathologyrevieworeducationalpurposes
- Exporttaggedareasintopresentations
• Addpre-codedorfreetextcommentstoanyslideorspecificcell
• Permanentlystoreimagesandaccesspatient’simagehistory
This application requires an optional purchase
XN-3000 Compact Automation System with Integrated DI-60
Both body fluid and peripheral blood smearscanbeanalyzedontheSysmex DI-60 Integrated Slide system by placing cyto-centrifuged prepared body fluid smears directly onto the connection feeder and through the bi-directional interface to SysmexWAM™oryourLIS.
DI-60 Body Fluid ApplicationProduct Information
Savevaluablemorphologist’stimewhileimprovingtheexpertiseofyourentirestaff.
Technical Specifications
Slide preparation methods • StandardCyto-centrifugepreparation• DefaultsettingsforShandon™/Wescor™/Statspin™
Stains • MayGrünwaldGiemsa,WrightGiemsa,Wright
Result parameters • WBC pre-classification: Neutrophils,Eosinophils,Lymphocytes,Macrophages(including
Monocytes),Other(Basophils,Lymphomacells,AtypicalLymphocytes,BlastsandTumorcells)andUnidentified
• Non WBC pre-classification: Smudge cells and Artifacts• Userhastheabilitytoaddadditionalcellcategoriesformanual
re-classification
Analyzers Supported • SysmexDI-60
Ordering Information • ThissoftwareapplicationisanoptionfortheDI-60CellImageAnalyzer• PartNumberAG241722
Sysmex Corporation1-5-1-Wakinohama-KaigandoriChuo-ku, Kobe 651-0073, JapanTel. +81 (78) 265-0521www.sysmex.co.jp