The demand for hot water is completely different in every household. One factor is the number of residents and another is their bathing and showering habits. For example, if three members of a family set off for work and school at the same time, lots of hot water needs to be continuously available for showers in short order.

Those who prefer a bath will also want to have enough hot water to fill the tub. The DHW cylinder should also be able to provide sufficient water if, in an apartment building for example, hot water is drawn from more than one outlet at the same time.

Vitocell DHW cylinders fulfil these requirements in every respect and can also meet every aspiration where the equipment level is concerned. In all instances, the installation of a solar thermal system is recommended to save energy and heat the water without cost.

DHW convenience for every demand

2/3

Page 4: DHW cylinder Vitocell (PDF 1 MB)

Introduction

Page 5: DHW cylinder Vitocell (PDF 1 MB)

5

In the Vitocell cylinder range, you'll find exactly the right DHW cylinder for your requirements. Depending on the application and installation options, select a DHW cylinder from our extensive product range.

Two energy efficiency classesBy default, most DHW cylinders with a compulsory identification cylinder capacity (up to 500 l capacity) meet energy efficiency class B. For selected cylinder types, it is also possible to choose between energy efficiency class A or B. Cylinders in class A are thermally insulated with an additional vacuum panel which reduces heat losses and therefore energy costs.

Selection of materials for DHW cylinders used for domestic hot water heating The quality of the inner surface of the DHW cylinder is crucial to providing DHW hygienically. For this reason, Viessmann relies on two high quality materials: Ceraprotect enamel coating for safe, lasting protection against corrosion in the Vitocell 100 range, and stainless steel in the Vitocell 300 range for outstanding hygiene standards.

The indirect coils inside Vitocell DHW cylinders reach right down to the cylinder floor. This enables them to heat the entire water content and make particularly economical use of the cylinder capacity.

Vitocell 300 made from stainless steelVitocell 300 DHW cylinders made from corrosion-resistant stainless steel meet some of the most stringent hygiene standards. Stainless steel is used in kitchens, laboratories, hospitals and the food processing industry for good reason, as it offers excellent hygienic properties. Its homogeneous surface retains these characteristics even after many years of use.

Vitocell 100 with Ceraprotect enamel coatingThe Vitocell 100 DHW cylinder with Ceraprotect enamel coating meets all requirements for convenient, economical DHW heating and is amongst the top selling enamelled DHW cylinders on the market today. The Ceraprotect enamel coating provides the DHW cylinder with safe and lasting protection against corrosion.

Take advantage of these benefits

� Vitocell 300 made of stainless steel Capacity: 130 to 500 litres

� Vitocell 100 with Ceraprotect enamel coating Capacity: 120 to 1000 litres

� Dual mode DHW cylinders for installation of solar thermal systems

� Internal indirect coil reaching right to the cylinder floor heats the entire water content

� Low heat losses through highly effective thermal insulation (for selected cylinder types with an integral vacuum panel for energy efficiency class A).

Vitocell 100‑V, CVAA‑A

1 Cylinder and indirect coil made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode

3 Internal indirect coil stretching right down to the cylinder floor heats up the entire water content

4 All-round CFC-free thermal insulation made from rigid polyurethane foam

5 Vacuum panel

1

3

4

2

Energy efficiency class A

for Vitocell 100-V, CVAA-A (160 l)

4/5

Page 6: DHW cylinder Vitocell (PDF 1 MB)

1 Stainless steel cylinder2 Inspection and cleaning aperture3 Stainless steel indirect coil drawn right

down to the cylinder floor – this heats the DHW cylinder fully and hygienically

4 Flanged aperture as additional cleaning aperture or for the installation of an immersion heater

5 All-round CFC-free thermal insulation made from rigid polyurethane foam

DHW cylinder (floorstanding)

Vitocell 300‑V

Vitocell 300-V(type EVI, 200 and 300 litre cylinder capacity, with flanged aperture)

1

2

3

4

5

Page 7: DHW cylinder Vitocell (PDF 1 MB)

Type EVA EVA EVA

Cylinder capacity litres 130 160 200

DimensionsLength øWidthHeight

mmmmmm

6336671111

633667

1203

633667

1423

Weight kg 77 84 98

Permissible operating pressure on the heating water side bar 3 3 3

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.13 1.20 1.36

Energy efficiency class B B B

Type EVI EVI

Cylinder capacity litres 200 300

DimensionsLength øWidthHeight

mmmmmm

581649

1420

633704

1779

Weight kg 76 100

Permissible operating pressure on the heating water side bar 25 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.38 1.92

Energy efficiency class B C

SpecificationVITOCELL 300-V

Type EVI

Cylinder capacity litres 500

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

925715975

1738

Weight kg 111

Permissible operating pressure on the heating water side bar 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.95

Energy efficiency class B

160 and 200 l capacity also available in white

6/7

Page 8: DHW cylinder Vitocell (PDF 1 MB)

5

1 Cylinder and indirect coil made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode 3 Internal indirect coil stretching right

down to the cylinder floor heats up the entire water content

4 All-round CFC-free thermal insulation made from rigid polyurethane foam

5 Vacuum panel

DHW cylinder (floorstanding)

Vitocell 100‑V

Vitocell 100-V(type CVAA-A, 200 l cylinder capacity)

1

2

3

4

Page 9: DHW cylinder Vitocell (PDF 1 MB)

Type CVW

Cylinder capacity litres 390

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650923

1624

Weight kg 190

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.80

Energy efficiency class B

Type CVAA-A CVA CVAA-A CVA CVAA

Cylinder capacity litres 160 160 200 200 300

DimensionsLength øWidthHeight

mmmmmm

581605

1189

581605

1189

581605

1409

581605

1409

667744

1734

Weight kg 86 86 97 97 156

Permissible operating pressure on the heating water side bar 25 25 25 25 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 0.97 1.35 1.04 1.46 1.65

Energy efficiency class A B A B B

SpecificationVITOCELL 100-V

160 and 200 litre capacity without flanged aperture; 300 litre capacity with flanged aperture

Also available in white

Type CVA CVA CVA

Cylinder capacity litres 500 750 1000

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650923

1948

960750

10452106

1060850

11452166

Weight kg 181 295 367

Permissible operating pressure on the heating water side bar 25 25 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.95 3.00 3.54

Energy efficiency class B – –

8/9

Page 10: DHW cylinder Vitocell (PDF 1 MB)

5

1 Cylinder and indirect coil made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode3 Internal indirect coil stretching right

down to the cylinder floor heats up the entire water content

4 All-round CFC-free thermal insulation made from rigid polyurethane foam

5 Vacuum panel

DHW cylinders for wall mounted boilers

Vitocell 100‑W

Vitocell 100-W(type CUGA-A)

1

2

3

4

Page 11: DHW cylinder Vitocell (PDF 1 MB)

SpecificationVITOCELL 100-W

Type CUGA-A CUGA CUGA-A CUGA

Cylinder capacity litres 120 120 150 150

DimensionsLength øWidthHeight

mmmmmm

596596914

596596914

641641942

641641942

Weight kg 75 75 88 88

Permissible operating pressure on the heating water side bar 10 10 10 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 0.75 1.10 0.84 1.21

Energy efficiency class A B A B

10/11

Page 12: DHW cylinder Vitocell (PDF 1 MB)

1 High grade stainless steel cylinder2 Stainless steel indirect coil reaching right

to the cylinder floor heats the entire water content

3 DHW connection4 DHW circulation connection5 Inspection and cleaning aperture6 Highly effective all-round CFC-free thermal

insulation made from rigid polyurethane foam

DHW cylinder (horizontal)

Vitocell 300‑HVitocell 100‑H

Vitocell 300-H(type EHA)

1

2

3

4

5

6

Page 13: DHW cylinder Vitocell (PDF 1 MB)

VITOCELL 100-H

Type CHA CHA CHA

Cylinder capacity litres 130 160 200

DimensionsLengthWidthHeight

mmmmmm

907640654

1052640654

1216640654

Weight kg 90 103 116

Permissible operating pressure on the heating water side bar 10 10 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential 1.15 1.29 1.34

Energy efficiency class B B B

VITOCELL 300-H

Type EHA EHA EHA EHA

Cylinder capacity litres 160 200 350 500

DimensionsLengthWidthHeight

mmmmmm

1072640654

1236640654

1590830786

1654910886

Weight kg 76 84 172 191

Permissible operating pressure on the heating water side bar 25 25 25 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.18 1.24 1.76 1.95

Energy efficiency class B B B B

Specification 12/13

Page 14: DHW cylinder Vitocell (PDF 1 MB)

1 Stainless steel cylinder2 Upper inspection and cleaning aperture3 Upper indirect coil – for reheating by the

boiler4 All-round CFC-free thermal insulation

made from rigid polyurethane foam 5 Lower indirect coil – solar collector

connection6 Front inspection and cleaning aperture

(also for installation of an immersion heater EHE)

DHW cylinder (dual mode)

Vitocell 300‑B

Vitocell 300-B(type EVB)

2

1

3

4

5

6

Page 15: DHW cylinder Vitocell (PDF 1 MB)

Type EVB

Cylinder capacity litres 300

DimensionsLength øWidthHeight

mmmmmm

633704

1779

Weight kg 114

Permissible operating pressure on the heating water side bar 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.92

Energy efficiency class C

SpecificationVITOCELL 300-B

Type EVB

Cylinder capacity litres 500

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

925715975

1738

Weight kg 125

Permissible operating pressure on the heating water side bar 25

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.95

Energy efficiency class B

14/15

Page 16: DHW cylinder Vitocell (PDF 1 MB)

1 Cylinder and indirect coils made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode3 Upper indirect coil – for reheating by the

boiler4 Immersion heater connection5 Lower indirect coil – solar collector

connection6 All-round CFC-free thermal insulation

made from rigid polyurethane foam7 Inspection and cleaning aperture (also for

installation of an immersion heater)

DHW cylinder (dual mode)

Vitocell 100‑B

Vitocell 100-B(type CVBB)

1

2

3

4

5

6

7

Page 17: DHW cylinder Vitocell (PDF 1 MB)

Type CVBB

Cylinder capacity litres 300

DimensionsLength øWidthHeight

mmmmmm

667744

1734

Weight kg 160

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.65

Energy efficiency class B

SpecificationVITOCELL 100-B

Type CVB CVB

Cylinder capacity litres 400 500

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650923

1624

859650923

1948

Weight kg 167 205

Permissible operating pressure on the heating water side bar 10 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.80 1.95

Energy efficiency class B B

Also available in white

400 l capacity also available in white

16/17

Page 18: DHW cylinder Vitocell (PDF 1 MB)

1 Cylinder and indirect coil made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode3 Internal indirect coil – for reheating by the

boiler4 Sensor well5 Cleaning aperture6 Dry immersion heater for limescale-

resistant heating7 All-round CFC-free thermal insulation

made from rigid polyurethane foam

DHW cylinder (dual mode) with immersion heater

Vitocell 100‑B

Vitocell 100-B(type CVE)

1

2

3

4

7

5

6

Page 19: DHW cylinder Vitocell (PDF 1 MB)

Type CVE

Cylinder capacity litres 300

DimensionsLength øWidthHeight

mmmmmm

627713

1704

Weight kg 178

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.79

Energy efficiency class C

SpecificationVITOCELL 100-B

Note:DHW cylinder Vitocell 100-B, type CVE with immersion heater EHE, for DHW heating with power generated on site (e.g. by a photovoltaic system) and an internal indirect coil for reheating by the boiler.

18/19

Page 20: DHW cylinder Vitocell (PDF 1 MB)

1 Inspection and cleaning aperture2 Steel cylinder with Ceraprotect enamel

coating3 Magnesium or impressed current anode4 All-round thermal insulation5 Upper indirect coil – for reheating by the

boiler6 Lower indirect coil – solar collector

connection7 Solar circuit pump8 Solar-Divicon9 SM1 solar control module

Compact cylinder (dual mode)

Vitocell 100‑B

Vitocell 100-B (type CVBA)

1

23

4

5

6

7

8

9

Page 21: DHW cylinder Vitocell (PDF 1 MB)

SpecificationVITOCELL 100-B

Type CVBA

Cylinder capacity litres 250

DimensionsLength øWidthHeight

mmmmmm

631860

1485

Weight kg 124

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.81

Energy efficiency class C

With solar control module (SM1) for operation via a Vitotronic control unit

Type CVBA

Cylinder capacity litres 250

DimensionsLength øWidthHeight

mmmmmm

631860

1485

Weight kg 124

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.81

Energy efficiency class C

With Vitosolic 100 (SD1)

Vitocell 100-B only available as part of a pack together with Vitosol 200-F, type SVK/SVKA.

Also available in white

For Viessmann boilers with the Vitotronic 100 control unit (types HC1A, HC1B, KC2B, KC4B), Vitotronic 200 (types HO1A, HO1B,

HO1C, HO1D, HO1E, KO1B, KO2B, KW6A, KW6B), the Vitocell 100-B must be ordered with the solar control module (type SM1).

Vitocell 100-B only available as part of a pack together with Vitosol 200-F, type SVK/SVKA.

Also available in white

The Vitocell 100-B with Vitosolic 100 (type SD1) must be ordered if an existing system is being retrofitted with a predecessor control

unit.

20/21

Page 22: DHW cylinder Vitocell (PDF 1 MB)

1 Cylinder and indirect coils made of steel, with Ceraprotect enamel coating

2 Magnesium or impressed current anode 3 Solar-Set with solar control module

or Vitosolic 100, flushing facility, air separator, pipework and variable speedhigh efficiency circulation pump

4 Upper indirect coil – for reheating by the boiler

5 Lower indirect coil – solar collector connection

6 All-round CFC-free thermal insulation made from rigid polyurethane foam

Compact cylinder (dual mode)

Vitocell 100‑UVitocell 100‑W

Vitocell 100-U (type CVUB)

1

2

34

5

6

Page 23: DHW cylinder Vitocell (PDF 1 MB)

With solar control module (SM1) for operation via a Vitotronic control unit

Type CVUBCylinder capacity litres 300DimensionsLength øWidthHeight

mmmmmm

660840

1735Weight kg 179Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.52

Energy efficiency class B

SpecificationVITOCELL 100-U/W

Also available in white

For Viessmann boilers with the Vitotronic 100 control unit (types HC1A, HC1B, KC2B, KC4B), Vitotronic 200 (types HO1A, HO1B,

HO1C, HO1D, HO1E, KO1B, KO2B, KW6A, KW6B), the Vitocell 100-W (type CUVB) must be ordered with the solar control module

(type SM1).

With Vitosolic 100 (SD1)

Type CVUBCylinder capacity litres 300DimensionsLength øWidthHeight

mmmmmm

660840

1735Weight kg 179

Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.52

Energy efficiency class B

Also available in white

The Vitocell 100-U with Vitosolic 100 (type SD1) must be ordered if an existing system is being retrofitted with a predecessor control

unit.

VITOCELL 100-U

With solar control module (SM1) for operation via a Vitotronic control unit with energy cockpit

Type CVUC-ACylinder capacity litres 300DimensionsLength øWidthHeight

mmmmmm

660840

1735Weight kg 179Permissible operating pressure on the heating water side bar 10

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.15

Energy efficiency class A

To use the energy cockpit with Viessmann boilers with the Vitotronic 200 control unit (type HO2B), the Vitocell 100-W (type CVUC-A)

must be ordered with the solar control module (type SM1).

VITOCELL 100-W

22/23

Page 24: DHW cylinder Vitocell (PDF 1 MB)

Cylinder for DHW heating systems with cylinder loading system

Vitocell 100‑L

Vitocell 100-L(type CVL, 500 l cylinder capacity)

1 Steel cylinder with Ceraprotect enamel coating

2 Upper inspection and cleaning aperture3 Magnesium or impressed current anode4 Front inspection and cleaning aperture

(also for installation of an immersion heater EHE and/or heating lance)

2

1

3

4

Page 25: DHW cylinder Vitocell (PDF 1 MB)

VITOTRANS 222

� Heat exchanger set for cylinder loading systems with a highly efficient cylinder loading pump and heating water pump

� Transferable heating output up to 80, 120 and 240 kW

Type CVL CVL CVL

Cylinder capacity litres 500 750 1000

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650923

1948

960750

10452106

1060850

11552166

Weight kg 156 241 312

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.95 2.70 2.95

Energy efficiency class B – –

SpecificationVITOCELL 100-L

24/25

Page 26: DHW cylinder Vitocell (PDF 1 MB)

1 Steel cylinder2 Various hydraulic connection options3 Connection for EHE immersion heater4 Stratification system5 Steel internal indirect coil for connection

to a heat source (e.g. solar collectors)6 All-round thermal insulation made from

polyester fleece7 Hydraulic connection for Vitotrans 353,

type PZS and PZM

Heating water buffer cylinder with integral internal indirect coil

Vitocell 140‑E/160‑E

Vitocell 160-E(type SESA)

1

23

4

5

6

7

7

7

2

2

2

2

2

Page 27: DHW cylinder Vitocell (PDF 1 MB)

VITOCELL 160-E (with stratification system)

Type SESA SESA

Cylinder capacity litres 750 950

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

1004790

10601895

1004790

10602195

Weight kg 183 210

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 3.0 3.2

Energy efficiency class – –

Can be combined with Vitotrans 353 (type PZS/PZM)

Can be combined with Solar-Divicon (type PS10)

Specification

VITOCELL 140-E

Type SEIA SEIB SEIA SEIA SEIA

Cylinder capacity litres 400*1 *2 400*3 600*1 *2 750*1 *2 950*1 *2

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

866650

10891617

859650885

1624

1004790

10591648

1004790

10591895

1004790

10592195

Weight kg 154 125 151 174 199

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.8 1.8 2.9 3.0 3.2

Energy efficiency class B B – – –

*1 Can be combined with Vitotrans 353 (type PZS/PZM), with 400 l capacity only with the Vitotrans 353 (type PZS)*2 Can be combined with Solar-Divicon (type PS10), with 400 l capacity included in standard delivery*3 With larger internal indirect coil of 2.1 m2

26/27

Page 28: DHW cylinder Vitocell (PDF 1 MB)

1 Steel cylinder2 Various hydraulic connection options3 All-round thermal insulation made from

polyester fleece4 Hydraulic connection for Vitotrans 353,

type PZS and PZM

Heating water buffer cylinderVitocell 100‑E

Vitocell 100-E(type SVPA, 750 l capacity)

1

2

3

2

2

2

2

4

4

4

2

Page 29: DHW cylinder Vitocell (PDF 1 MB)

Type SVP

Cylinder capacity litres 46

DimensionsLength (depth)WidthHeight

mmmmmm

352450926

Weight kg 18

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 0.87

Energy efficiency class B

*1 Can be combined with Vitotrans 353, type PZS and PZM*2 Standard thermal insulation (2-part), also available with high efficiency thermal insulation (3-part)

SpecificationVITOCELL 100-E

Type SVPA SVPA SVPA SVPA SVPA SVPA

Cylinder capacity litres 400*1 600*1 750*1 950*1 1500*2 2000*2

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650885

1624

1004790

10591648

1004790

10591895

1004790

10592195

1310110013102051

1310110013102479

Weight kg 122 128 147 168 217 253

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.8 2.9 3.0 3.2 3.7 4.55

Energy efficiency class B – – – – –

Also available in white

Type SVW

Cylinder capacity litres 200

DimensionsLength øWidthHeight

mmmmmm

581640

1409

Weight kg 80

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.46

Energy efficiency class B

Also available in white

28/29

Page 30: DHW cylinder Vitocell (PDF 1 MB)

Freshwater modulesVitotrans 353

Type PBS Type PBM Type PBL

Type PZS Type PZM

Vitotrans 353, fully pre-assembled station for convenient DHW heating using the instantaneous water heater principle for installation on Vitocell 100-E, Vitocell 140-E and Vitocell 160-E cylinders

Vitotrans 353, fully pre-assembled station for convenient DHW heating using the instantaneous water heater principle for wall mounting

Page 31: DHW cylinder Vitocell (PDF 1 MB)

SpecificationVITOTRANS 353

Type PBS PBM PBL

Draw‑off rateAccording to SPF test procedure, performance factor 1 (PF 1)

l/min up to 25 up to 48 up to 68

DimensionsLength (depth)WidthHeight

mmmmmm

300250960

350450960

350450960

Weight kg 23 40 42

DHW capacity l 0.55 1.78 2.59

Heating water capacity l 0.58 1.91 2.41

Type PZS PZM

Draw‑off rateAccording to SPF test procedure, performance factor 1 (PF 1)

l/min up to 25 up to 48

DimensionsLength (depth)WidthHeight

mmmmmm

300250960

350450960

Weight kg 23 40

DHW capacity l 0.55 1.78

Heating water capacity l 0.58 1.91

Note on draw‑off rate:Draw-off rate in line with SPF testing process (testing for fresh water heating in accordance with the Institute for Solar Technology in Switzerland).

Performance factor 1 (PF 1): � At a set DHW temperature of 45 °C � At a heating water inlet temperature of 60 °C � At a cold water inlet temperature of 10 °C

30/31

Page 32: DHW cylinder Vitocell (PDF 1 MB)

1 Corrugated stainless steel indirect coil for DHW

2 Solar pump module (type PS10) for mounting on a cylinder, with variable speed HE circulation pump (accessories)

3 Connection for EHE immersion heater4 Stratification system5 Steel internal indirect coil for connection

to a heat source (e.g. solar collectors)6 Solar pipework for connecting the solar

pump module to the internal indirect coil (accessories)

7 All-round thermal insulation made from polyester fleece

Heating water buffer cylinder with DHW heating

Vitocell 340‑M/360‑M

Vitocell 360-M with Solar-Divicon (accessories) (type SVSA)

1

2

3

4

56

7

Page 33: DHW cylinder Vitocell (PDF 1 MB)

VITOCELL 340-M

Type SVKA SVKA SVKA

Total capacityContents– Heating water– DHW– Heat exchanger

litres

litreslitreslitres

400

37525

750

7083012

950

9063014

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

859650885

1624

1004790

10591895

1004790

10592195

Weight kg 125 214 239

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 1.8 3.0 3.2

Energy efficiency class B – –

VITOCELL 360-M(with stratification system)

Type SVSA SVSA

Total capacityContents– Heating water– DHW– Heat exchanger

litres

litreslitreslitres

750

7083012

950

9063014

DimensionsLength øLength ø (excl. thermal insulation)WidthHeight

mmmmmmmm

1004790

10591895

1004790

10592195

Weight kg 223 248

Standby heat loss (QST ) to EN 12897:2006, QST at 45 K temperature differential

kWh/24 h 3.0 3.2

Energy efficiency class – –

Can be combined with Solar-Divicon (type PS10)

Specification

Can be combined with Solar-Divicon (type PS10)

32/33

Page 34: DHW cylinder Vitocell (PDF 1 MB)

The company

Page 35: DHW cylinder Vitocell (PDF 1 MB)

Energy Efficiency Award 2010

Viessmann Group

Viessmann – climate of innovation

Viessmann is one of the world's leading manufacturers of intelligent, convenient and efficient systems for heating, cooling and decentralised power generation.

As a third generation family run business, Viessmann has been supplying highly efficient and clean heating systems for many decades.

A strong brand creates trustTogether with our brand label, our key brand message is an identifying feature recognised globally. "Climate of innovation" is a promise on three levels: It is a commitment to a culture of innovation. It is also a promise of enhanced product benefits and, at the same time, an obligation to protect the environment.

Acting in a sustainable mannerFor Viessmann, taking responsibility signifies a commitment to acting sustainably.

This means bringing ecology, economy and social responsibility into harmony with each other, ensuring that current needs are

satisfied without compromising the quality of life for the generations to come.

We consider climate protection, environmental responsibility and resource efficiency to be key priorities throughout our company, which has more than 11,500 employees worldwide.

Example of Best PracticeWith its strategic sustainability project, Viessmann demonstrates at its own head office in Allendorf (Eder) that the energy and climate policy goals set for 2050 can in fact be achieved today with commercially available technology. The results speak for themselves:

� Expansion of renewables to 60 percent � CO2 emissions reduced by 80 per cent

The long term goal is for the company to meet all its own heating energy requirements by sustainable means.

The comprehensive product range from the Viessmann Group for all energy sources and output ranges

� Boilers for oil or gas � Combined heat and power generation � Hybrid appliances � Heat pumps � Wood combustion technology � Biogas production plants � Biogas upgrading plants � Solar thermal � Photovoltaics � Accessories � Refrigeration systems

Company details � Established in: 1917 � Employees: 11,500 � Group turnover: 2.2 billion euros � Export share: 56 percent � 22 production companies in 11 countries � 74 countries with sales companies and

branches � 120 sales offices worldwide

2009/2011/2013:

German Sustainability Award

for Production/Brand/Resource

Efficiency

34/35

Page 36: DHW cylinder Vitocell (PDF 1 MB)

Viessmann Werke GmbH & Co KG35107 Allendorf (Eder)Telephone +49 6452 70-0Fax +49 6452 70-2780www.viessmann.com

Your trade partner:

9443 395 - 3 GB 12/2015

Copyright Viessmann.

Duplication and alternative use only with prior written consent.

Subject to technical modifications.