    1/2

    d r y + w e t r i s e r s y s t e m s

    Data Sheet File 11 Page 1 of 2

    Boxes conform to BS 5041 Parts 4 and 5

    1.5mm steel construction with 3mm thick architrave 38mm wide

    Red dry powder coated finish. Other colours available

    Lock and key and wired glass window fixed with glazing rubber

    Boxes for foam inlets and single breechings available on request

    f e a t u r e s

    Dry/wet

    Macron manufactures and supplies,

    for installation by others, all necessarycomponents for dry and wet riser

    systems.

    The dry riser system is only charged

    with water when in use, whereas the

    wet riser system is permanently

    connected to a water supply.

    All components are manufactured strictly

    to relevant British Standards. They can be

    used in multi-storey buildings where a firefighting system should be available for

    fire brigade use.

    Dry riser landing valve boxDry riser landing valve box

    Vertical breeching box

    Wet riser landing valve box

    Dry riser inlet box Horizontal breeching box for twin outlet

    = =

    400

    610

    690mm

    460mm

    210

    540mm325

    383

    210

    595mm

    675mm

    475mm

    230

    395mm 295mm

    155

    =

    150

    230

    230

    610mm

    690mm

    420mm

    210

    540mm

    260mm=

    395

    =

    =475mm

    595mm

    230

    312

    675mm

    283

    295

    Inlet breechingOblique patternlanding valve

    Horizontal patternlanding valve

    Tyco Fire Suppression & Building Products, Burlingham House, Hewett Road, Gapton Hall Industrial Estate,

    Great Yarmouth, Norfolk NR31 0NN, UK. Tel: +44 (0)1493 417600 Fax: +44 (0)1493 417700

    E-mail: [email protected] Web: www.macron-safety.com

    Datasheet Ref. MDF11 A1

    l

    o (http://www.verypdf.com)

    This is trial versionIf you want get full version, please register it, thank you.

    www.verypdf.como (http://www.verypdf.com)o (http://www.verypdf.com)

    http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/
  • 8/22/2019 DF11 Dry & Wet Riser Systems

    2/2

    d r y + w e t r i s e r s y s t e m s

    Data Sheet File 11 Page 2 of 2

    Dry riser system

    An inlet breeching at ground level

    provides the connection to the watersupply and can be installed in a

    horizontal or vertical position. The

    breeching has a 102mm (4 in)

    screwed or flanged outlet and two

    65mm (21/2 in) instantaneous male

    inlets fitted with non-return valves and

    drain valve as standard. It is housed in

    a dry riser box, normally recessed into

    the external wall of the building. Each

    draw-off point from the dry riser is

    fitted with a landing valve, situated in a

    recess or cabinet. Manufacture is in

    accordance with BS 5041 Part 2.

    The valves have instantaneous

    couplings to BS 336, for connection

    to the fire-fighting hose.

    The head of the dry riser should be

    fitted with an air release valve which

    ventilates pipework as water is

    pumped in and closes automatically

    by water pressure.

    Wet riser system

    This system is permanently

    connected to the water supply.

    Therefore inlet breeching and air

    release valves are not required. Each

    draw-off point requires a landing

    valve, with either a rubber metal

    seated valve. They are

    manufactured in accordance with BS

    5041 Part 1. The instantaneous

    female outlet is to BS 336. Inletconnections may be screwed or

    flanged as required.

    Air release valve

    Landing valve

    100mm bore main pipe

    Top Floor

    First Floor

    Ground Floor

    Basement

    Pipe bracket

    Landing valve

    Landing valve /landing valve box

    A dry riser system

    Dry riser landing valve box

    External wall

    Dry riser inlet breeching

    Dry riser inlet boxwith glazed door

    Flanged tee piece

    25mm drain valve

    Optional

    Part No. Product10251 4 Way Dry Riser Inlet Breeching11016 2.5 Dry Riser Gate Valve

    (inlet: 2.5 Female BSPT)10254 2.5 Dry Riser Gate Valve

    (Flange: BS 4505 PN16)11165 2.5 Dry Riser Gate Valve

    (Flange: BS10 Table D)

    Part No. Product

    10250 2 Way Dry Riser Inlet Breeching10246 2.5 Oblique Pattern Hydrant

    Valve (Flange: BS10 Table D)11045 2.5 Oblique Pattern Hydrant

    Valve (DN65 Flange: BS 4505 PN16)10247 2.5 Horizontal Pattern Hydrant

    Valve

    Tyco Fire Suppression & Building Products, Burlingham House, Hewett Road, Gapton Hall Industrial Estate,

    Great Yarmouth, Norfolk NR31 0NN, UK. Tel: +44 (0)1493 417600 Fax: +44 (0)1493 417700

    E-mail: [email protected] Web: www.macron-safety.com

    Datasheet Ref. MDF11 A1

    34

    l

    o (http://www.verypdf.com)

    This is trial versionIf you want get full version, please register it, thank you.

    www.verypdf.como (http://www.verypdf.com)o (http://www.verypdf.com)

    http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/http://www.verypdf.com/