Development and validation of a reagent based on enzymatic ... · A. Tobeña Montanuy, S. Dueñas...

1
. The presence of histamine in fish is becoming increasingly important to consumers and producers alike, due to the potential threats of toxicity to humans and consequently health implications. In the scientific field, histamine has the potential to be applied as indicator unsanitary conditions during fish manipulation. Current methods for analysis of histamine are HPLC, ELISA, and fluorimetry which sometimes require expensive and sophisticated instrumentation and as consequence skilled technicians. BioSystems presents a new, simple and rapid enzymatic method determination of histamine in fish that can be automated. The method is based on the specific reaction of histamine with recombinant histamine dehydrogenase (from E. Coli) causing the reduction of a soluble tetrazolium salt to form formazan salt that absorbs at 420 nm. Thus can be measured by visible spectrophotometry and correlate it, through a calibration, with histamine concentration. This new reagent has a long stability, is liquid and ready-to-use, avoiding end-user influence. It has been formulated to be used in any photometer or automated analyzer. Linearity, limit of detection (LoD), limit of quantification (LoQ) , repeatability, within laboratory reproducibility, trueness and recovery were characterized using a BioSystems Y15 ® automated analyzer and HPLC method. Method comparison between enzymatic kit & HPLC-UV Type of method: Quantitative Analyte: Histamine Units: mg/kg Matrix: Raw tuna, water-packed tuna, oil-packed tuna, raw sardines, oil-packed sardines, semi-preserved anchovy fillets Range: 10 to 200 mg/kg Reference method used: Analyte, range and units: Histamine, range of 10 to 500 mg/kg Accreditation: PEE/1/119, accredited by ENAC according to UNE-EN ISO/IEC 17025 (Technical Annex No. 96/LE230) Matrix: Fish, aquaculture and derivative products Method: HPLC-UV detector Limits of detection / Limits of quantification DEVELOPMENT AND VALIDATION OF AN ENZYMATIC REAGENT FOR AUTOMATING HISTAMINE ANALYSIS IN FISH Sample preparation (fish): Accurately weigh approximately 5 g of homogenized sample and add 25 ml of distilled water. Shake until the sample is homogeneously suspended. Incubate the sample for 20 minutes in a boiling water bath, stirring periodically. Let stand to room temperature and centrifuge for 10 minutes, at least at 2000g. Histamine in the sample originates, by means of the coupled reactions described below, a colored complex that can be measured by spectrophotometry: 1. M.L. Latorre-Moratalla et al. Validation of an ultra high pressure liquid chromatographic method for the determination of biologically active amines in food. J. Chromatogr. A. 1216 (2009) 7715–7720. 2. Tsuneo Sato et al. Simple and rapid determination of histamine in food using a new histamine dehydrogenase from Rhizobium sp. Anal. Bio- chem. 346 (2005) 320–326. 3. International organization of vine and wine (OIV), Compendium of international methods of wine and must analysis Vol. 1 & 2, Paris (2010). 4. AOAC International (1998). AOAC Peer-Verified Methods Program. Manual on Policies and Procedures. Maryland. USA. INTRODUCTION 5.COMMISSION DECISION (2002/657/EC) of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analyti- cal methods and the interpretation of results. 6.COMMISSION DIRECTIVE 98/53/EC of 16 July 1998 laying down the sampling methods and the methods of analysis for the official control of the levels for certain contaminants in foodstuffs. 7.Ellison SLR, Rosslein M, Williams A. (2000). Quantifying uncertainty in analytical measurement. 2nd edition. EURACHEM/CITAC Guide. 8.EURACHEM-GUIDE (1998). The fitness for purpose of analytical methods: A laboratory guide to method validation and related topics. LGC, Teddington. 9.Horwitz W. (1998). A simple method for evaluating data from an interlaboratory study. Journal of AOAC International Vol. 81, No. 6. 10.Hotwitz W. (2003). Validation: An invisible component of measurement. AOAC International. 11.Huber L. (1998). Validation of analytical methods: review and strategy. LC-GC International, pp. 96-105. 12.JC Miller JN. Miller. (1993). Estadística para química analítica. Addison-Wesley Iberoamericana. 2nd edition. 13.Statistical Subcommittee of the AMC. (2004). The amazing Horwitz function. Technical Brief No. 17 July. Royal Society of Chemistry. 14.Thompson M. (2000). Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing. Analyst, 125 385-386. 15.Thompson M, Ellison S. LR, Wood R. (2002). Harmonized guidelines for single-laboratory validation of methods of analysis. IUPAC Technical Report. Pure Appl. Chem., vol 74, no. 5, pp. 835,855. Abstract Product Performance Measurement procedure Conclusions Bibliography Reagents and calibrators are ready to use and stable until expiry date. Results confirms that FoodQuality ® Histamine Enzymatic (BioSystems) can quantitatively measure histamine in fish samples with similar accuracy and precision than the HPLC method. Furthermore, this test can be automated in a analyzer (the kit is adapted for Y15 ® or Y25 ® analyzers from BioSystems) or can be used in a photometer with a simple sample treatment making histamine analysis more accurate, fast and easy. The small volumes used also allows an affordable analysis and better waste management. A. Tobeña Montanuy, S. Dueñas Ros, S. Muñoz Hernández BioSystems S.A., Barcelona (Spain) [email protected] Raw Mackerel Raw Sardine Pickled anchovies ANFACO (HPLC) 34 39 64 61 BioSystems 10 12 16 14 97 89 Canned Tuna 2 2 8 8 121 122 567 592 450 437 Anchovies paté 4 4 0 0 Tuna sirloin 65 74 7 7 Canned Sardine 28 27 1 0 Canned Mackerel 69 81 50 25 0 -25 -50 0 100 200 300 Histamine (mg/Kg) % Diference 400 500 600 50 25 0 -25 -50 0 100 200 300 Histamine (mg/Kg) % Diference 400 500 600 600 500 400 300 200 100 0 0 100 200 300 mg/Kg (ANFACO) mg/Kg (BioSystems) 400 500 600 Oil-packed sardines LOD = 5.77 2.85 4.28 4.58 0.29 7.01 17 8.5 13 14 0.9 21 LOQ = 3 x LOD Semi-preserved anchovy fillets Water-packed Tuna Oil-packed Tuna Raw Tuna Raw Sardines Best-fit values Slope Y-int. when X=0.0 0.9774 ± 0.01387 2.332 ± 2.647 95% CI Slope Y-int. when X=0.0 0.9476 to 1.007 -3.345 to 8.009 Goodness of fit r 0.9972 Data Number of X values 17 Equation y = 0.9774x + 2.332

Transcript of Development and validation of a reagent based on enzymatic ... · A. Tobeña Montanuy, S. Dueñas...

Page 1: Development and validation of a reagent based on enzymatic ... · A. Tobeña Montanuy, S. Dueñas Ros, S. Muñoz Hernández , N. Toro Funes BioSystems S.A., Barcelona (Spain) atobena@biosystems.es

.

The presence of histamine in fish is becoming increasingly important to consumers and producers alike, due to the potential threats of toxicity to humans and consequently health implications. In the scientific field, histamine has the potential to be applied as indicator unsanitary conditions during fish manipulation. Current methods for analysis of histamine are HPLC, ELISA, and fluorimetry which sometimes require expensive and sophisticated instrumentation and as consequence skilled technicians. BioSystems presents a new, simple and rapid enzymatic method determination of histamine in fish that can be automated.

The method is based on the specific reaction of histamine with recombinant histamine dehydrogenase (from E. Coli) causing the reduction of a soluble tetrazolium salt to form formazan salt that absorbs at 420 nm. Thus can be measured by visible spectrophotometry and correlate it, through a calibration, with histamine concentration. This new reagent has a long stability, is liquid and ready-to-use, avoiding end-user influence. It has been formulated to be used in any photometer or automated analyzer. Linearity, limit of detection (LoD), limit of quantification (LoQ) , repeatability, within laboratory reproducibility, trueness and recovery were characterized using a BioSystems Y15® automated analyzer and HPLC method.

Method comparison between enzymatic kit & HPLC-UV

Type of method: QuantitativeAnalyte: HistamineUnits: mg/kgMatrix: Raw tuna, water-packed tuna, oil-packed tuna, raw sardines, oil-packed sardines, semi-preserved anchovy filletsRange: 10 to 200 mg/kg

Reference method used:Analyte, range and units: Histamine, range of 10 to 500 mg/kgAccreditation: PEE/1/119, accredited by ENAC according to UNE-EN ISO/IEC 17025 (Technical Annex No. 96/LE230)Matrix: Fish, aquaculture and derivative productsMethod: HPLC-UV detector

Limits of detection / Limits of quantification

DEVELOPMENT AND VALIDATION OF AN ENZYMATIC REAGENT FOR AUTOMATING HISTAMINE ANALYSIS IN FISH

Sample preparation (fish): Accurately weigh approximately 5 g of homogenized sample and add 25 ml of distilled water. Shake until the sample is homogeneously suspended.Incubate the sample for 20 minutes in a boiling water bath, stirring periodically. Let stand to room temperature and centrifuge for 10 minutes, at least at 2000g.

Histamine in the sample originates, by means of the coupled reactions described below, a colored complex that can be measured by spectrophotometry:

1. M.L. Latorre-Moratalla et al. Validation of an ultra high pressure liquid chromatographic method for the determination of biologically active amines in food. J. Chromatogr. A. 1216 (2009) 7715–7720.2. Tsuneo Sato et al. Simple and rapid determination of histamine in food using a new histamine dehydrogenase from Rhizobium sp. Anal. Bio-chem. 346 (2005) 320–326.3. International organization of vine and wine (OIV), Compendium of international methods of wine and must analysis Vol. 1 & 2, Paris (2010).4. AOAC International (1998). AOAC Peer-Verified Methods Program. Manual on Policies and Procedures. Maryland. USA. INTRODUCTION5.COMMISSION DECISION (2002/657/EC) of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analyti-cal methods and the interpretation of results.6.COMMISSION DIRECTIVE 98/53/EC of 16 July 1998 laying down the sampling methods and the methods of analysis for the official control of the levels for certain contaminants in foodstuffs.7.Ellison SLR, Rosslein M, Williams A. (2000). Quantifying uncertainty in analytical measurement. 2nd edition. EURACHEM/CITAC Guide.8.EURACHEM-GUIDE (1998). The fitness for purpose of analytical methods: A laboratory guide to method validation and related topics. LGC, Teddington.9.Horwitz W. (1998). A simple method for evaluating data from an interlaboratory study. Journal of AOAC International Vol. 81, No. 6.10.Hotwitz W. (2003). Validation: An invisible component of measurement. AOAC International.11.Huber L. (1998). Validation of analytical methods: review and strategy. LC-GC International, pp. 96-105.12.JC Miller JN. Miller. (1993). Estadística para química analítica. Addison-Wesley Iberoamericana. 2nd edition.13.Statistical Subcommittee of the AMC. (2004). The amazing Horwitz function. Technical Brief No. 17 July. Royal Society of Chemistry.14.Thompson M. (2000). Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing. Analyst, 125 385-386.15.Thompson M, Ellison S. LR, Wood R. (2002). Harmonized guidelines for single-laboratory validation of methods of analysis. IUPAC Technical Report. Pure Appl. Chem., vol 74, no. 5, pp. 835,855.

Abstract Product Performance

Measurement procedure

Conclusions

Bibliography

Reagents and calibrators are ready to use and stable until expiry date.

Results confirms that FoodQuality® Histamine Enzymatic (BioSystems) can quantitatively measure histamine in fish samples with similar accuracy and precision than the HPLC method. Furthermore, this test can be automated in a analyzer (the kit is adapted for Y15® or Y25® analyzers from BioSystems) or can be used in a photometer with a simple sample treatment making histamine analysis more accurate, fast and easy. The small volumes used also allows an affordable analysis and better waste management.

A. Tobeña Montanuy, S. Dueñas Ros, S. Muñoz HernándezBioSystems S.A., Barcelona (Spain)

[email protected]

Raw Mackerel

Raw Sardine

Pickled anchovies

ANFACO (HPLC)

34 39

6461

BioSystems

10 12

1614

9789

Canned Tuna

2 2

88

121122

567592

450437

Anchovies paté 44

00Tuna sirloin

6574

77Canned Sardine

2827

10Canned Mackerel

6981

50

25

0

-25

-500 100 200 300

Histamine (mg/Kg)

% D

ifere

nce

400 500 600

50

25

0

-25

-500 100 200 300

Histamine (mg/Kg)

% D

ifere

nce

400 500 600

600

500

400

300

200

100

00

100 200 300mg/Kg (ANFACO)

mg/

Kg

(Bio

Sys

tem

s)

400 500 600

Oil-packed sardines

LOD = 5.77 2.85 4.28 4.58 0.29 7.01

17 8.5 13 14 0.9 21LOQ = 3 x LOD

Semi-preservedanchovy fillets

Water-packedTuna

Oil-packedTuna

RawTuna

RawSardines

Best-fit valuesSlopeY-int. when X=0.0

0.9774 ± 0.013872.332 ± 2.647

95% CISlopeY-int. when X=0.0

0.9476 to 1.007-3.345 to 8.009

Goodness of fitr 0.9972

DataNumber of X values 17

Equation y = 0.9774x + 2.332