Developing Interoperability Standards for Personal Health ... · Developing Interoperability...
Transcript of Developing Interoperability Standards for Personal Health ... · Developing Interoperability...
Developing Interoperability Standards
for Personal Health Devices
Daidi Zhong, Chongqing University
Michael J. Kirwan, DSheet Ltd.
Xiaolian Duan, Chongqing Academy of Science & Technology
Geneva, 24th Nov, 2013
Mission Statement
Personal Health Devices• Form Consensus
• Developing Standards
• Build Interoperability
• Global Deployment
• Empower Consumer
Computing Engines
IEEE 11073-
Personal Health Device (PHD) WG
� 319 members
� 206 organizations
� Weekly conference calls
� Face to face meetings 3 times per year
� International
involvement in
the Work Group� 52.9 % North America
� 25.8 % Europe
� 21.3 % Far East
4
-00103 Overview
Serial IrDA Bluetooth USB ZigBee Layers 1-4
Layers 5-7
OSI
IEEE 11073-PHD Stack
Communication Protocols
NFC
-20601 Optimized Exchange Protocol
-10404Pulse
Oximeter
-10407Blood
Pressure
-10408Thermo-meter
-10415WeighingScale
-10417Glucose
-10441Cardio
-10442Strength
-10471ActivityData
…
Device Specializations
ISO
TC215
IEEE
11073-PHD
CEN
FDA
…
Continua
…
Adoption Path
IEEE 11073-xxxxx ISO/IEEE 11073-xxxxx
MoU
ISO Pub
ISO Approve
ISO Submitted
IEEE Pub
RevCom
Balloting
Drafting
NesCom
Progress of PHD Standards
Approved and published international standards
Approved and published IEEE stds
Drafts underway
Continua Health Alliance (2006-)
� Continua is a not-for-profit (U.S. - 501c6) association focused
on the development of interoperability standards for personal
connected health devices.
� Continua also works as a trade association to enable adoption
and knowledge sharing within providers, policy/regulatory
bodies, payers, vendors and consumers.
� 240 member organizations
PHRPHRPHRPHREHREHREHREHRNFC
HealthReportingNetwork
(HRN)Interface
Personal Device(PAN/LAN/TAN)
Weight Scale
Pulse Oximeter
Independent
Living Activity
Cardio / Strength
Adherence
Monitor
Glucose Meter
Pulse /
Blood Pressure
Thermometer
Peak Flow
DeviceConnectivity
WideArea
Network
(WAN) Interface
HIEHIEHIEHIENHINNHINNHINNHINCCDCCDCCDCCDPCD PCD PCD PCD 01010101
Water
Gas
Temperature
Fall
Continua Health Alliance
E2E Architecture
Low Energy
HRN Device
WAN
Device
Application
Hosting
Device
Transport Adaption
Contact Information
Daidi Zhong
Michael J. Kirwan
Web Address
http://standards.ieee.org/develop/wg/PHD.html
http://www.continuaalliance.org/
http://www.bluetooth.com
Step by Step� Membership: PHD WG, IEEE-SA, IEEE
� Engagement (use case, tiger team)
� Draft the (Project Authorization Request) PAR
� PAR Submission (NesCom) -- 3~4 opportunities per year
� Draft the standard
� Forming the Ballot Group -- ≥30 days
� MEC Review -- 30 days
� Initial Ballot -- ≥30 days
� Recirculations (0 .... *) -- ≥10 days
� RevCom Submission -- 3~4 submission deadlines per year
� RevCom Approval
� IEEE editorial process -- 2 – 3 months
� Published