Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined...

6
ORGINAL ARTICLE Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * Hydraulics Research Institute, National Water Research Centre, Egypt Received 23 December 2012; revised 30 July 2013; accepted 5 August 2013 Available online 15 September 2013 KEYWORDS Weir; SOBEK; Formula; Weirs with 1 or 2 pipes; Predicted Equations; Verification Abstract In this study, Formulae were developed for rehabilitated weirs (i.e., combined weirs and orifices, weirs with 1 or 2 pipes in their bodies). Several sites of the existing rehabilitated weirs in El-Fayoum were visited. During the visits, measurements were undertaken (i.e., discharge, velocity, and water levels) before and after the rehabilitation of weirs. The measurements were analyzed and used as input data for model SOBEK. The model was calibrated and verified against field data. For- mulae were developed from the data measurements. Moreover, two Formulae were developed, based on the model results for weirs with 1 or 2 pipes. These Formulae were validated against field measurements. The developed weir Formulae related the parameters, defining the weir with the pipe dimensions, and the discharge. These Formulae would assist engineers in designing the modification required to develop the existing weirs in order to increase the discharge. ª 2013 Production and hosting by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria University. 1. Introduction Weirs are the simplest hydraulic structures that have been used for centuries by hydraulic engineers for regulation of flow depth, flow measurements, energy dissipation, flow, and flow diversion [1,2]. Weirs have many types (i.e., Fayoum weir, Sharp-crested weir, Rectangular weir, Broad-crested weir, Ogee weir, Narrow-crested weir, Ordinary weir, and submerged weir). Weirs are overflow structures for measuring discharge and controlling flow in open channels [3]. Gates and pipes are also considered as measuring and controlling flow devices. Gates and weirs have been used extensively for flow control and discharge measurement in open channel. In terms of the importance of increasing the discharge, this research was done to suffice the expected water demands. The research objective is to increase the weir discharge without increasing the water head above it. This could be achieved by opening the two pipes to increase the discharge. The investigation phases are presented in this paper under the following headlines: Reviewing the literature. Site visits and description of the study area. Setting the research objectives. * Tel.: +20 100 5286635; fax: +20 42189539. E-mail address: [email protected] Peer review under responsibility of Faculty of Engineering, Alexandria University. Production and hosting by Elsevier Alexandria Engineering Journal (2013) 52, 763–768 Alexandria University Alexandria Engineering Journal www.elsevier.com/locate/aej www.sciencedirect.com 1110-0168 ª 2013 Production and hosting by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria University. http://dx.doi.org/10.1016/j.aej.2013.08.001

Transcript of Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined...

Page 1: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

Alexandria Engineering Journal (2013) 52, 763–768

Alexandria University

Alexandria Engineering Journal

www.elsevier.com/locate/aejwww.sciencedirect.com

ORGINAL ARTICLE

Developing Formulae for combined weir and orifice

(case study: EL-Fayoum weirs)

Ahmed M. El-Belasy *

Hydraulics Research Institute, National Water Research Centre, Egypt

Received 23 December 2012; revised 30 July 2013; accepted 5 August 2013

Available online 15 September 2013

*

E-

Pe

U

11

ht

KEYWORDS

Weir;

SOBEK;

Formula;

Weirs with 1 or 2 pipes;

Predicted Equations;

Verification

Tel.: +20 100 5286635; fax:mail address: ahmedbeasy5@

er review under responsibility

niversity.

Production an

10-0168 ª 2013 Production

tp://dx.doi.org/10.1016/j.aej.2

+20 421yahoo.c

of Facu

d hostin

and hosti

013.08.0

Abstract In this study, Formulae were developed for rehabilitated weirs (i.e., combined weirs and

orifices, weirs with 1 or 2 pipes in their bodies). Several sites of the existing rehabilitated weirs in

El-Fayoum were visited. During the visits, measurements were undertaken (i.e., discharge, velocity,

and water levels) before and after the rehabilitation of weirs. The measurements were analyzed and

used as input data for model SOBEK. The model was calibrated and verified against field data. For-

mulae were developed from the data measurements. Moreover, two Formulae were developed,

based on the model results for weirs with 1 or 2 pipes. These Formulae were validated against field

measurements.

The developed weir Formulae related the parameters, defining the weir with the pipe dimensions,

and the discharge. These Formulae would assist engineers in designing the modification required to

develop the existing weirs in order to increase the discharge.ª 2013 Production and hosting by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria

University.

1. Introduction

Weirs are the simplest hydraulic structures that have been usedfor centuries by hydraulic engineers for regulation of flow

depth, flow measurements, energy dissipation, flow, and flowdiversion [1,2]. Weirs have many types (i.e., Fayoum weir,Sharp-crested weir, Rectangular weir, Broad-crested weir, Ogee

weir, Narrow-crested weir, Ordinary weir, and submerged

89539.om

lty of Engineering, Alexandria

g by Elsevier

ng by Elsevier B.V. on behalf of F

01

weir). Weirs are overflow structures for measuring dischargeand controlling flow in open channels [3]. Gates and pipes arealso considered as measuring and controlling flow devices.

Gates and weirs have been used extensively for flow control

and discharge measurement in open channel.In terms of the importance of increasing the discharge, this

research was done to suffice the expected water demands. The

research objective is to increase the weir discharge withoutincreasing the water head above it. This could be achievedby opening the two pipes to increase the discharge.

The investigation phases are presented in this paper underthe following headlines:

� Reviewing the literature.� Site visits and description of the study area.� Setting the research objectives.

aculty of Engineering, Alexandria University.

Page 2: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

764 A.M. El-Belasy

� Field measurements.

� Analyzing the measurements.� Modeling using SOBEK.� Establishing Formulae and verifying them.

2. Reviewing the literature

Literature, in the field of hydraulic structures, was reviewed. Itwas found that many efforts, concerning the use of sluice gatesas a discharge measurement, were achieved by many research-

ers (i.e., [4–8]).

� [9] Developed a generalized discharge equation for sluice

gates based on Henry’s curves. Providing a top openingfor the gate allows simultaneous underflow and overflowconditions.

� Regarding the flow over weirs, many efforts were reportedin the literature (i.e., [10–14]).� The specifications and the proper installation of weirs for

flow measurements are discussed by [15,16].� Problems concerning sedimentation and depositions areminimized by combined weirs and gates as outlined by [17].

3. Site visits and description of the study area

The study area was visited several times. During the visits, data

were collected, measurements were undertaken, observationswere documented, and photos were captured.

Based on these visits, the study area could be described, as

follows:

� Baher Hassan Wassef (Hassan Wassef Canal) is 13.8 km

long and is located in AL Fayoum governorate.� The designed bed width of the canal is 16.0 m with a bedslope of 10 cm/km.

Road Level

Flow Direction

Crest Level (24.60)

Upstream Water Level (25.80)

Floor Level (21.15) D = 0.75 m

Figure 1 Hassan Was

� The canal bed level is 21.50 m + MSL at its start and is

19.70 m + MSL at its end. The canal is regulated by Alla-houn Barrage.� Fayoum Type weir was constructed downstream the bar-

rage at a distance of 0.80 km to measure the discharge pass-ing through the canal.� The crest level is 24.60 m +MSL with designed upstreamand downstream maximum water levels of

25.80 m + MSL and 24.50 m +MSL, respectively, with awater head of 1.20 m. Fig. 1 presents the longitudinal bedprofile and the dimensions of the weir.

� The purpose of this weir is to control the flow and to main-tain the stability of the upstream canal cross sections.� There are two pipes with diameter of 0.75 m inside the weir.

These pipes were designed to empty the upstream reach formaintenance purposes. On the other hand, these pipes couldallow the discharge to pass during low flows.� The weir was designed to supply 130,000 feddan with irriga-

tion water. The irrigated area is expected to increase to150,000 Feddan.

4. Setting the study objectives

This study was initiated in order to develop Formulae for reha-

bilitated weirs (modified weirs with 1 or 2 pipes in their bodiesto allow more water to pass). These Formulae would assistengineers in the design process. A methodology was thus de-

signed to fulfill the study objectives.

5. Field measurements

Field measurements were carried out along Hassan Wasef Ca-nal prior to the pipe operation, as follows:

� A hydrographical survey, for a total distance of 13.80 km,was executed (66 cross sections, 200 m apart, along thecanal).

Two gated pipes

(27.00)

Downstream Water Level (24.50)

ef weir dimensions.

Page 3: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) 765

� Upstream and downstream water levels together with the

discharge were measured at the weir location during 1 year.� Water levels and the corresponding discharge along thecanal (from the head regulator till the end) were measured.

6. Analyzing the measurements

The measurements prior to the pipe operation were analyzedfrom which the following were obtained:

6.1. Discharge equation

From the measured upstream and downstream water levels,the discharges were calculated and plotted, Fig. 2. From thisfigure, it was clear that the maximum recorded water head over

the weir is 1.16 m and the corresponding discharge is 41.50 m3/s.

Also, from these data, the discharge coefficient of the weir

was determined. According to [18], the discharge equation ofthe Fayoum Type weir is:

Q ¼ 2

3CdB

ffiffiffiffiffi2g

pH

32 ¼ CBHn ð1Þ

in which Q is the discharge passing over the weir [L3/s], Cd the

discharge coefficient [�], B the crest length of the weir [L], Hthe head difference between upstream water level and weircrest level [L], and C is equal to Cd multiplied by the square

root of the 2g [L].The value of C could be determined if the value of n was

considered to be 1.50. Using the measured discharge and headover the weir crest, the value of C was determined. It was

found that C and Cd are equal to 2.06 and 0.7, respectively.The standard deviations of the calculated average value of Cand its coefficient of variation were found to be equal to

0.04 and 0.12, respectively. These are acceptable values, fromthe engineering point of view, and are indicators to the accu-racy of the field measurements.

It is also worthy to mention that the value of C in the liter-ature for Fayoum Type weir varies between 1.65 and 2.0 [18].

Compared to the values in the literature, the value of Cd

varies between 0.56 and 0.72. The reason for the obtained highvalues of C and Cd is due to the fact that the flow head on theweir is higher than the designed value.

Using the above values for C and n, the discharge equation

could be written as follows:

10

15

20

25

30

35

40

45

0.6 0.7 0.8 0.9 1.0 1.1 1.2

H, Water depth above the weir crest (m)

Q, D

isch

arge

(m

3 /s)

Figure 2 Measured discharge and water head over the weir crest.

Q ¼ 2:06BH1:5 ð2Þ

The value of C and n could also be determined, by using thelogarithmic relationship between the measured discharge (Q)and the head (H) over weir. These values could be determinedusing the regression analysis. This resulted in a value of C to be

2.1 and n to be 1.92. In this case, the equation could be writtenas follow:

Q ¼ 2:1BH1:92 ð3Þ

Fig. 3 shows the relation between the discharge and thehead over weir for the measured and calculated data, using

Eq. (3). The results indicated that Eq. (3) gives better valuesfor the calculated discharge with an error percentage varyingbetween �1.42% and 3.25%.

6.1. Canal bed roughness

The roughness coefficient was calculated using the measuredfield data and manning formula. The results showed that the

average value of manning roughness coefficient (n) is 0.0275.This value is within the known range of the natural earthcanals [19].

7. Modeling using SOBEK

The study area was modeled using a 1-D mathematical model

(SOBEK-channel) to determine the discharge of the 2-pipedweir. SOBEK-channel flow [20] is an one-dimensional modelthat was developed by Delft Hydraulics. It is a tool based on

knowledge and experience gained from many rivers and estuar-ies in the world. SOBEK can be used for flood forecasting,navigation, optimizing drainage systems, controlling irrigationsystems, reservoir operation, sewer overflow design, ground

water level control, river morphology regulation, and waterquality control. The integrated approach also means thatSOBEK can combine river systems, urban systems, and rural

systems for a total water management solution.This section is devoted to display the model schematization,

calibration, verification, and application.

7.1. Model schematization

A mathematical model of the study area was developed to sim-

ulate 13.8 km from Al-ahoun regulator to the end of the canal.

Figure 3 The relation between the discharge and the over weir

head for the measured data and calculated using Eq. (3).

Page 4: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

Flow direction

DownstreamBoundary

WeirLocation

UpstreamBoundary

Figure 4 Model layout.

766 A.M. El-Belasy

The simulations have been carried out using the following fieldmeasurements:

� 36 Measuring cross sections.� Weir dimensions.� All off-takes� Water levels and discharges along the canal, Fig. 4.

7.2. Model calibration

The model calibration was carried out using the measured dis-charges and corresponding water levels. The boundary condi-

tions that were used, during calibration, is as follows:

� The passing discharge from the head regulator is 26.95 m3/s.

� The water level downstream the head regulator is 25.62 m.� The water level at the end of the canal is 23.18 m.

23.0

23.5

24.0

24.5

25.0

25.5

26.0

0 2 4 6 8 10 12 14

Wat

er L

evel

(m+M

SL)

Distance from Head Regulator (km)

Calculated water levels

Measured water levels

WeirLocation

Figure 5 Model calibration.

Fig. 5 shows the water surface profile, obtained from themodel and from measurements, along the canal during the cal-ibration phase. The roughness coefficient of the study area,

during calibration, was determined to be 0.0275.

7.3. Model simulations

The model was run using different discharges in order to pre-

dict the discharge of the 1 piped and 2 piped weirs. From themodel simulations, the discharge and the water depth abovethe weir were obtained.

Fig. 6 represents the computed results of the cases 1 and 2piped weirs, respectively. It was found that the maximum dis-charge of the weir without pipes is 43.60 m3/s at a level of

25.80 m (H = 1.20), while the discharge was 44.65 m3/s when1 pipe was operated, at the same water level and increased to45.70 m3/s, in case of operating 2 pipes.

10

15

20

25

30

35

40

45

0.6 0.7 0.8 0.9 1 1.1 1.2

H, Water depth above the weir crest (m)

Q, D

isch

arge

(m

3 /s)

Measured Discharge (Weir)

Calculated discharge by model (Weir)

Calculated discharge by model (Weir and one pipe)

Calculated discharge by model (Weir and two pipe)

Figure 6 Relation between the discharges and the head above

the weir crest (1 and 2-piped weir).

Page 5: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) 767

8. Establishing Formulae and verifying them

The computed head, above the weir, and the correspondingdischarges in case of using a 1-piped weir was used to deter-

mine the coefficient of the weir Formula.The values of C and nweir were computed in the same man-

ner (as in the case of a no pipes-weir).

They were first calculated by considering the value of nweirto be 1.50 and the computed discharge and head over the weircrest were used to evaluate the value of C.

It was found that the C value is equal to 2.14 and Cd value

is equal to 0.72. The standard deviation of the calculated aver-age value of C is equal to 0.08, and its coefficient of variation isequal to 0.03. These values are considered to be acceptable.

Using the above values for C and n, the discharge equationwas obtained to be as follows:

Q ¼ 2:14BH1:5 ð4Þ

Figure 7 Relation between water depth above the weir crest and

discharge calculated by model and using Eq. (5), 1-piped weir.

Figure 8 Relation between water depth above the weir crest and

discharge calculated by model and using Eq. (7), 2-piped weir.

Table 1 Measured discharges and heads over the 2-piped weirs.

Head above the weir (m) Discharge (m3/s)

Measured Predicted from m

0.675 17.49 17.98

1.020 34.20 35.30

1.150 41.12 42.70

Then, they were secondly calculated by using the logarith-mic relationship between the discharge (Q) and the head overthe weir (H). Applying the regression analysis, the values were

found to be 2.19 and 1.72, for C and nweir, respectively. Theobtained equation is given below.

Q ¼ 2:14BH1:72 ð5Þ

The results indicated that Eq. (5) gives better values for thecalculated discharge with a percentage of error that ranges

between �0.54% and 0.32%. Fig. 7 shows the relation betweenthe discharge and the head over the weir based on measure-ments and computations using Eq. (5).

8.1. Established Formulae for 2-piped weirs

The model results, Fig. 8, for 2-piped weirs were used in theFormulae establishment. The values of C and n were com-

puted in the same manner. The value of n was first consideredto be 1.50 and the measured discharge and head over the crestof the weir. It was found that the value of C was 2.24 and the

value of Cd was 0.76. The standard deviation of the calculatedaverage value of C is equal to 0.05 and its coefficient of varia-tion is equal to 0.02. Also, the value of Cd in the literature var-

ies between 0.56 and 0.72. The discharge Formula could bewritten as follows:

Q ¼ 2:24BH1:5 ð6Þ

The value of n was, secondly, computed using the logarith-mic relationship between the measured discharge (Q) and theHead over the weir (H). By regression analysis, the values were

found to be 2.28 and 1.63 for C and n, respectively. The estab-lished Formulae could be written as follow:

Q ¼ 2:28BH1:63 ð7Þ

The results indicated that Eq. (7) gives better values with apercentage of error varying between 0.05% and 2.5%. Fig. 8represents the relation between the discharge and the head

over the weir of the measured and calculated values usingEq. (7).

8.2. Verifying the Formulae of the 2-piped weirs

The head over the weir and the discharges through the 2 pipeswere measured 3 times and are listed in Table 1. These values

were used to verify the established Formulae of the 2-pipedweirs. The discharges were computed using model and Eq.(7) and were compared to the measured values, at the same

water levels where an acceptable error ranging between 2.8%and 3.8% was found for the predicted values by the modeland ranges between 3.9% and 4.40% for predicted by Eq. (6).

Error %

odel Predicted by Eq. (7) Model Eq. (7)

18.00 2.80 2.90

35.32 3.20 3.28

42.95 3.80 4.40

Page 6: Developing Formulae for combined weir and orifice (case ... · Developing Formulae for combined weir and orifice (case study: EL-Fayoum weirs) Ahmed M. El-Belasy * ... houn Barrage.

768 A.M. El-Belasy

9. Conclusions and recommendations

From the above investigation, the following conclusions werereached:

� Formulae, for discharge prediction over the no-pipes, 1-piped and 2-piped weirs, were developed. The established

Formulae for the 2-piped were verified against measure-ments where an error percentage that ranged between2.9% and 4.4% was determined. On the other hand, theestablished Formulae for the discharge over the weir with

no-pipes were verified against measurements where an errorpercentage that ranged between �1.42% and 3.25% wasdetermined. These Formulae would be most probably assist

engineers to design piped-weirs.� These piped weirs are expected to allow more discharge tosuffice the extra water demands. This was seen through

the present investigation, as follows:� The 1-piped weir increased the discharge by 1.05 m3/s at

a water head of 1.20 m

� The 2-piped weir increased the discharge by 2.10 m3/s ata water head of 1.20 m

� The values of C and Cd of the established Formulae for the

weir with no-pipes weir were found to be within the rangementioned in the literature. On the other hand, the C andCd values, of the established Formulae for the 1-piped

and 2-piped weirs, were found to be higher than the valuesof the no-pipes weir.� It is recommended to develop Formulae for weirs with dif-

ferent numbers of pipes with different diameters. This couldbe achieved by using a physical model. It is also recom-mended to conduct field measurements for the 1-piped weirs

to verify the established Formula.

References

[1] G. Abouzeid, Improvement of the hydraulic performance of

sharp-crested side weirs in circular channels. In: English

International Water Technology Conference, IWTC8 2004,

Egypt, 2004, pp. 499–509.

[2] W. Boiten, Flow measuring structures, Delft Hydraulics,

Publications number 478, August 1993.

[3] R.S. Khurmi, A Text Book of Hydraulics, Fluid Mechanics and

Hydraulic Machines, 12 ed., 1982.

[4] H.R. Henry, Discussion to diffusion of submerged jets, by M.L.

Albertson, Y.B. Dai, R.A. Jensen, H. Rouse, Trans. ASCE, vol.

115, 1950, pp. 687–694.

[5] N. Rajaratnam, K. Subramanya, FlowEquation for the sluice

gate, Proc. ASCE J. Irrig. Drain. Div. 93 (IR3) (1967) 167–186.

[6] N. Rajaratnam, Free flow immediately below sluice gates, Proc.

ASCE J. Hydraulic Div. 103 (HY4) (1977) 345–351.

[7] R.H. French, Open-Channel Hydraulics, McGraw Hill Book

Co, NewYork, 1986, pp. 343–353.

[8] K. Subramanya, Flow in Open Channels, First revised ed., Tata

Mc-Graw-Hill Publishing Company Ltd., New Delhi, 1986, pp.

219–226 (7th reprint).

[9] P.K. Swamee, Sluice-gate discharge equations, Proc. ASCE J.

Irrig. Drain. Eng. 118 (1) (1992) 57–60.

[10] A. Ackers, W.R. White, J.A. Perkins, A.J.M. Harrison, Weirs

and Flumes for Low Measurements, John Wiley & Sons, New

York, 1978, pp. 44–85 (Chapter 3).

[11] M.G. Bos (ed.), Discharge measurement structures, 3rd ed.,

International Institute for Land Reclamation and Improvement,

Wageningen, The Netherlands, 1989.

[12] C.E. Kindsvater, R.W. Carter, Discharge characteristics of

rectangular thin-plate weirs, J. Hydraulics Div., Vol. 83, No.

HY6, paper No. 1453, 1957, pp. 1–36.

[13] P.K. Swamee, Generalized rectangular weir equations, J.

Hydraul. Eng. 114 (8) (1988) 945–949.

[14] B.R. Munson, D.F. Young, T.H. Okiishi, Fundamentals of fluid

mechanics, 2nd ed., JohnWiley and Sons, Inc., New York, 1994.

[15] British Standard Institution (BSI), Thin-plate weirs and Venturi

flumes, in methods of measurement of liquid flow in open

channel, Part 4A, BSI 3680, BSI, London, 1965.

[16] USBR, Water measurement manual, United States Dept. of the

Interior, Bureau of Reclamation, Second ed., Denver, Col.,

revised reprint, 1984, pp. 7–42 (1967).

[17] A.A. Alhamid, A.M. Negm, A.M. Al-Brahim, Discharge

equation for proposed self-cleaning device, J. King Saud Univ.

Eng. Sci., Riyadh, Saudi Arabia 9 (1) (1997) 13–24.

[18] Sharl Shukry Sakla, Design of Irrigation Structures, text book,

El-Mansoura, Second ed., published by Lotus printing co, 2002.

[19] Simons, Senturk, Sediment Technology, 1992.

[20] WL|Delft Hydraulics, SOBEK River/Estuary User Manual,

SOBEK Help Desk Delft, the Netherlands, 2005.