Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

17
Detector Backgrounds in the HERA ep- Colldider F. Willeke, BNL October 9, 2012

Transcript of Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Page 1: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Detector Backgrounds in the HERA ep-Colldider

F. Willeke, BNLOctober 9, 2012

Page 2: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

HERA Overview

ZEUS

HERMES

HERA-B

Page 3: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

HERA

• Provided collisions with 920GeV p beams and 27.5 GeV longitudinally spin-polarized lepton (e+/e-) beams for colliding beam experiments H1 and ZEUS.

• Two 6 km circumference rings in underground tunnel (20m). Proton ring with superconducting magnets, lepton ring with superconducting RF.

• Luminosity: 5.4 1031 cm-2s-1

• Lepton ring and proton rings also provided independently beam to fixed target experiments (HERMES and HERA-B)

Page 4: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

HERA Chronology• 1984 Construction Project authorized in 1984• 1991 Commissioning Complete • 1992 Start Operation 820GeV p+ & 27.5GeV e-• 1993-4 820GeV p & 27.5 GeV e+• 1995 add HERMES IR and spin rotators• 1996 add HERA-B IR, 920GeV p – 27.5GeV e+• 1997 reach design luminosity• 1997-8 IP NEG, Hardware upgrade• 1998-2000 920GeV p & 27.5GeV e-/e+ productive runs >50 pb-1y-1

• 2000-2001 Luminosity Upgrade, Factor 3-5 , H1 & ZEUS Spin rotator Upgrade brings machine components into detectors to 2m from IP including S.C. magnets Synchrotron radiation from beam separation magnets passes through entire IR and is absorbed far (30m) from IP

• 2001 Fall Re-commissioning• 2002-2003 Resolving Detector Background Issues• 2004-2007 Productive luminosity runs >100pb-1y-1, p-e+/e- ,long. Polarized leptons• Runs with varying proton energy: 450GeV-620GeV (FL)

HERA I

HERA II

Page 5: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

HERA Accelerator Parameters HERA Accelerator Parameters

protons per bunch Np /1011

normalized emittance eN /mm

Proton b functions b*y,x /m

Leptons Current Ie /mA

Lepton emittance ee /mA

number of coll. Bunches nb

E vert. bb tune shift/ip Dnye

hor./vert. beam size at IP sx,y,p,e /mm

specific Luminosity Ls /1030cm-2s-1 mA-2

Luminosity L /1031cm-2s-1

1 0.85

20 (15-20)

0.18, 2.45 0.18, 2.45

58 50

20 20

174 174

0.045 0.050

114x30 112x25

1.8 2.

7 5.4

Design Achieved

Page 6: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

80k beampipe

!

Detector

Page 7: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

2002-2003

Vacuum clean, minor traces of Methane, Ethane after warmup

IR vacuum improving rapidly and in steps after warm up of sc. Magnets with 80K beam pipe

IR Pumping:Distributed NEGLumped Ion pumpTi-Subl.Pumps

Page 8: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

H1 Detector

protons

leptons

Lq Ar Hadron Cal

EM Cal

m ChambersDrift Ch

mVDForward Cal

Backward Cal

Solenoidcoil

yoke

Page 9: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Background Issues after Upgrade of the Interaction Region

• Synchrotron radiation from far away (100m) bend resolved immediately

• Faulty Design of Backscatter mask for MVX and drift chambers, conceptually straight forward fix, but required large shut down

• Poor collimator design in both ZEUS and H1 detectors: no cooling, poor geometry and large HOM heating: high gas load generated during injection affecting beginning of each run:

straight forward fix, but required a large shut down

• Proton backgrounds from collisions of 920GeV p with desorbed gas generated by e beam synchrotron radiation on vacuum component of p-side of IP

Severe problem which disappeared only slowly over several years of running

Page 10: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Issues worried about which did not cause problems

• e particle backgrounds: High energy leptons after rest gas collisions get bent into detector by separation magnetic

fields: This was only a noticeable contribution to background shortly after machine was turned on

• Impact of 80K beam pipe of SC IR magnets: There was never evidence of any detrimental effect, on the contrary, 80K surface acted as cryo-pump for CO2, Methane …• Direct Synchrotron radiation from the lepton side IR quads and separation magnets This required careful adjustments of IR beam orbits and was not really a problem• Synchrotron Radiation Back Scattering from keyhole-masks of the IR vacuum system on the

hadron-side of the IP This required good IR orbit control but did not cause a major background issue• Synchrotron radiation backgrounds in drift chambers and radiation dose to micro vertex

detectors: Always critical but usually under control by careful tuning of the IR orbits, the beam

parameters (tunes, chromaticity, coupling)• Small angle low energy synchrotron radiation desorbed gases in the detector region Vacuum inside the detector beam pipe indeed worse than in the rst of the IR. This effect might have contributed in addition to to lack of pumping (one ion pump at 3.6m) and limited conductance

Page 11: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Issue: • High occupancy of calorimeters reduces the

fraction of useful data. • It is caused by debris from proton rest gas

interaction. • Debris scatter off the vacuum components

and the masks against back scattered synchrotron radiation from the crotch absorber

Background from 920GeV p scattering on desorbed Gases in the IP

Page 12: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Secondary Vertices detected in the H1 detectors

Page 13: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Background from 920GeV p scattering on desorbed Gases in the IP

Study of Background Multiplicities:No evidence of vacuum contamination Date explained by CO2 in residual gas

HERA I

HERA II

Page 14: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Background from 920GeV p scattering on desorbed Gases in the IP

• Why was this a major problem for HERA II and not for HERA I (before 2000)? (This was never satisfactorily answered)

- Crotch Absorber only 11m from IP, more intense desorption from back scattered photons,

however vacuum in IR 1E-10- 1E-11- Methan production in IR quadrupole NEG Pumps: no evidence for Methane or Ethane in beam vacuum- HERA I started with small proton and lepton currents (30mA/15mA) and intensity

was increased gradually to 70mA/45mA) between 1992-2000 no venting of IRs, whereas HERA II started with 100mA proton currents and 40mA lepton currents, there were several IR vacuum leaks which always caused a set back in vacuum conditions

Page 15: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Hadron Backgrounds cont’d

• The Hadron induced backgrounds reduced slowly and by 2004, reached levels were, while still being important, they did not constitute a major obstacle for data taking

• Improvements occurred in steps after each warm up of the superconducting IR magnets and subsequent reactivation of the IR NEG pumps. Interpreted as effect of more efficient NEG and cryo pumping

• There were several vacuum leaks in the IR which required vent of the IR vacuum. This was followed by increased background levels which recovered quickly and had the tendency to drop below the levels before the leak: interpreted as an effect of flushing the IR vacuum with N2

Page 16: Detector Backgrounds in the HERA ep-Colldider F. Willeke, BNL October 9, 2012.

Conclusions• HERA backgrounds from synchrotron Radiation and Hadronic background

were found at unexpected high levels after an upgrade of the IR regions which brought machine elements much closer to the IP (2m).

• Synchrotron radiation backgrounds were soon under control after some flaws with synchrotron radiation masks were fixed and after beam tuning became routine

• The most problematic backgrounds were caused by scattering of high energy protons on the rest gas desorbed by synchrotron radiation from the lepton beam.

• While the geometric conditions after the upgrade favored somewhat higher backgrounds, the main reasons for the problem was that extremely good IR vacuum conditions are required to operate a high luminosity and high energy ep collider with tolerable background conditions.