Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK...

30
Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Transcript of Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK...

Page 1: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Detectable Warnings

X

Correct Placement if X < 5 feetCorrect Placement if X > 5 feet

GRADE BREAK

PROWAG(R304.2.1)

Page 2: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(Advisory R304.2.3)

“… the vertical rows of truncated domes in a detectable warning surface should be aligned to perpendicular or radial to the grade break…”

Detectable Warnings

Page 3: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG (R304)

ADAAG(4.29)Detectable Warnings

Avoid gaps in detectable warnings

Page 4: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG (R304)

ADAAG(4.29)Detectable Warnings

“Detectable warning surfaces shall contrast visually with adjacent… walkway surfaces, either light-on-dark or dark-on-light.”

Page 5: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Detectable Warnings PROWAG (R304)

ADAAG(4.29)

Detectable warnings are not wayfinding devices. This application has a gap.

Page 6: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Detectable Warnings PROWAG (R304)

ADAAG(4.29)

Does this meet ADA?

Page 7: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Detectable Warnings PROWAG (R221)

ADAAG(4.29)

“The overuse of detectable warning surfaces should be avoided in the interests of message clarity. However, where commercial driveways are provided with

traffic control devices or otherwise are permitted to operate like public streets, detectable warnings should be provided at the junction between the pedestrian

route and the street.”

Page 8: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

MDOT Special Provision 03SP803(A)“Do not construct detectable warnings by forming or stamping in newly cast concrete.”

Detectable Warnings

Page 9: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R301.5.2)

ADAAG(4.5.2)Changes in Level

Page 10: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R301.5.2)

ADAAG(4.5.2)Changes in Level

Page 11: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Gaps and Grates PROWAG(R301.7)

ADAAG(4.5.4)

“Gratings… shall have spaces no greater than ½”

wide in one direction.”

“Gratings… shall be placed so that the long dimension is

perpendicular to the dominant direction of travel .”

Page 12: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R301.7.1)

“Openings shall not permit passage of a sphere more than ½” in diameter.”

ADAAG(4.5.4)Bridge Joints

Page 13: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R301.7.1)

ADAAG(4.5.4)Bridge Joints

A properly installed bridge expansion device covers the gap

Page 14: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Protruding Objects PROWAG(R401)

ADAAG(4.4.1)

Page 15: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R410)

ADAAG(10.2.1)Bus Pads

Page 16: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Buses often need additional room for loadingBuses often need additional room for loading

Bus Pads PROWAG(R410)

ADAAG(10.2.1)

Page 17: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Parking

ADAAG does not specifically address on-street parking. Local jurisdictions should look to the PROWAG to provide accessible on-street parking.

PROWAG(R216, R308)

PROWAG: Where on-street parking is marked or metered, accessible parking spaces complying with R308 shall be provided on the block perimeter…

On-Street Parking

Page 18: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R306.2)

“Each crosswalk with pedestrian signal indication shall have an accessible pedestrian signal which includes audible and vibrotactile indications of the WALK interval.”

“A device that communicates information about pedestrian timing in non-visual format such as audible tones, verbal messages, and/or vibrating surfaces.”

WHAT ARE ACCESSIBLE PEDESTRIAN SIGNALS?

Section 4E.06 of the MUTCD:

PROWAC R306.2:

Accessible Ped Signals (APS)

Page 19: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R306.2)

Also found in MUTCD 4E.09

Accessible Ped Signals (APS)

Page 20: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R306.2)Pushbutton Placement

This is not accessible!This is not accessible!

Page 21: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R404)Pushbutton Placement

Pushbuttons must have a level landingPushbuttons must have a level landing

Page 22: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Not behind clutter!Not behind clutter!

Pushbutton Placement PROWAG(R404)

Page 23: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Pushbutton placement: not behind grassPushbutton placement: not behind grass

Pushbutton Placement PROWAG(R404)

Page 24: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R306.2)Pushbutton Placement

Where are we sending pedestrians?Where are we sending pedestrians?

40 feet

Page 25: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R404)Pushbutton Placement

Page 26: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Pedestrian count-down signal tells pedestrians how much Pedestrian count-down signal tells pedestrians how much crossing time is left …crossing time is left …

Countdown Ped Signals PROWAGR306

Page 27: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAC R205“When an existing pedestrian access route is blocked by construction, alteration, maintenance, or other temporary conditions, an alternate pedestrian access route complying to the maximum extent feasible shall be provided.”

FHWA ADA Toolkit Desk Reference:“A smooth, continuous, hard surface should be provided throughout the entire length of the temporary pedestrian facility. There should be no curbs or abrupt changes in grade or terrain that could cause tripping or be a barrier to wheelchair use. The geometry and alignment of the facility should meet the applicable requirements of the "Americans with Disabilities Act Accessibly Guidelines for Buildings and Facilities (ADAAG)" (see Section 1A.11).”

PROWAG(R205)Pedestrian Detour Route

Page 28: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

PROWAG(R302)

“Where the alternate circulation path is exposed to adjacent construction, excavation drop-offs, traffic, or other hazards, it shall be protected with a pedestrian barricade or

channelizing device…”

A continuous bottom edge 6” max above the groundupper rail 36” minimum above ground

Pedestrian Detour Route

Page 29: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Pedestrian Detour Route

Pedestrian route should be easy to travelPedestrian route should be easy to travel

Page 30: Detectable Warnings X Correct Placement if X < 5 feet Correct Placement if X > 5 feet GRADE BREAK PROWAG (R304.2.1)

Safe and Accessible

It is possible to meet ADA and still have an unsafe condition.It is possible to meet ADA and still have an unsafe condition.