2
CONSTRUCTION & DIMENSIONS - CONDUCTOR PARAMETER - • Number of Pairs 6 • AWG Size 22 • Conductor Stranding 7x30 • Conductor Type Tinned Copper • Nominal DCR 17 Ohm/1000ſt INSULATION PARAMETER - • Insulation Type FEP • Insulation ickness 0.007 in • Insulation Color Code 1.Black-Red, 2. Black-White 3. Black-Green 4. Black-Blue 5. Black-Yellow 6. Black-Brown SHIELDING PARAMETER - • Shield Type Individually Shielded • Drain Wire Type Tinned Copper • Drain Wire AWG 24 AWG ELECTRICAL CHARACTERISTICS - • Nominal Impedance 55 Ohm • Nom. Cap. Between Conductors 35 pF/ſt • Nom. Cap. Conductor to Shield 67 pF/ſt OVERALL CONSTRUCTION PARAMETERS - Total Number of Conductors 12 Jacket Type Flexible Plenum Jacket ickness 0.017 in Nominal Cable O.D. 0.304 in Plenum Yes NEC UL Rating CMP RoHS Compliant Yes Pull Tension 125 lbs Bend Radius 2.736 in Cable Weight 69 lbs OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS - UL Flammability NFPA 262 Plenum Operating Range -0 to 60 Deg C UL Voltage Rating 300 Construction & Dimensions Overall Construction Overall Electrical & Optical Characteristics Detailed Specification & Technical Data D25432 Audio and Control 2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com 6Pr. 22AWG Ind. Shielded CMP

Transcript of Detailed Specification & Technical · PDF fileTotal Number of Conductors 12 ... Overall...

Page 1: Detailed Specification & Technical  · PDF fileTotal Number of Conductors 12 ... Overall Electrical & Optical Characteristics Detailed Specification & Technical Data D25432

CONSTRUCTION & DIMENSIONS -

CONDUCTOR PARAMETER - • Number of Pairs 6

• AWG Size 22

• Conductor Stranding 7x30

• Conductor Type Tinned Copper

• Nominal DCR 17 Ohm/1000ft

INSULATION PARAMETER - • Insulation Type FEP

• Insulation Thickness 0.007 in

• Insulation Color Code 1.Black-Red, 2. Black-White 3. Black-Green 4. Black-Blue 5. Black-Yellow 6. Black-Brown

SHIELDING PARAMETER - • Shield Type Individually Shielded

• Drain Wire Type Tinned Copper

• Drain Wire AWG 24 AWG

ELECTRICAL CHARACTERISTICS - • Nominal Impedance 55 Ohm

• Nom. Cap. Between Conductors 35 pF/ft

• Nom. Cap. Conductor to Shield 67 pF/ft

OVERALL CONSTRUCTION PARAMETERS -Total Number of Conductors 12

Jacket Type Flexible Plenum

Jacket Thickness 0.017 in

Nominal Cable O.D. 0.304 in

Plenum Yes

NEC UL Rating CMP

RoHS Compliant Yes

Pull Tension 125 lbs

Bend Radius 2.736 in

Cable Weight 69 lbs

OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS -UL Flammability NFPA 262 Plenum

Operating Range -0 to 60 Deg C

UL Voltage Rating 300

Construction & Dimensions

Overall Construction

Overall Electrical & Optical Characteristics

Detailed Specification & Technical Data

D25432

Audio and Control

2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com

6Pr. 22AWG Ind. Shielded CMP

Page 2: Detailed Specification & Technical  · PDF fileTotal Number of Conductors 12 ... Overall Electrical & Optical Characteristics Detailed Specification & Technical Data D25432

RELATED PRODUCTS -Non Plenum Number D432

3 Pin XLR Male CN-NC3MX

3 Pin XLR Female CN-NC3FX

3.5mm Stereo Mini CN-NYS231

Related Products

Detailed Specification & Technical Data

2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com

D25432

Audio and Control6Pr. 22AWG Ind. Shielded CMP