DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT...

20
C 1.0 E 1.0 AS REQUIRED BY MODULE MANUFACTURER B 1.0 1" X W IRONRIDGE FRA IRONRIDGE NORTH TILT LEG IRONRIDGE U-FOOT ANGLE OF SOLAR INCIDENCE C IRONRIDGE SOUTH TILT LEG W C G 1.4 J 1.4 R H 1.4 K 1.4 IRONRIDGE RAIL MEMBRANE FLASHING VARIES BY ROOF TYPE PV MODULE FRAME IRONRIDGE UNIVERSAL FASTENING OBJECT 3 8 " PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE UNIVERSAL FASTENING OBJECT PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL FASTENING OBJECT 1" PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL FASTENING OBJECT 1" SNOW LOAD, PSF EXPOSURE CAT MODULE TYPE RISK CAT WIND SPEED, MPH MODULE W DC MODULE QTY - - - - 60-CELL, GENERIC - - SHEET NAME JOB NO. ISSUE DATE SHEET NO. SHEET SIZE 24X36 1495 ZEPHYR AVE, HAYWARD, CA 94544 800.227.9523 IRONRIDGE.COM NOT FOR CONSTRUCTION REVISION HISTORY APPROVAL STATUS REV DESCRIPTION DATE 3.0 FR FLAT ROOF PV SYSTEM DETAILS: FLAT ROOF ATTACHMENT (FRA) (UFO) DEC 2018 IR 1.0 Scale: 1"=1'-0" PLAN VIEW, FRA, PORTRAIT MODULE A Scale: 1"=1'-0" SIDE VIEW, FRA, PORTRAIT MODULE B Scale: 6"=1'-0" DETAIL, END CLAMP (UFO) PLAN E Scale: 6"=1'-0" DETAIL, END CLAMP (UFO) FRONT F Scale: 6"=1'-0" DETAIL, MID CLAMP PLAN C Scale: 6"=1'-0" DETAIL, MID CLAMP FRONT D CLIENT NAME PROJECT NAME PROJECT ADDRESS SYSTEM KW DC IRONRIDGE FLAT ROOF MOUNT SYSTEM

Transcript of DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT...

Page 1: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

1.0

E

1.0

AS REQUIRED BY

MODULE MANUFACTURER

B

1.0

1"

X

W

IRONRIDGE FRA

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

IRONRIDGE SOUTH TILT LEG

W

C

G

1.4

J

1.4

R

H

1.4

K

1.4

IRONRIDGE RAIL

MEMBRANE FLASHING

VARIES BY ROOF TYPE

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS: FLAT

ROOF

ATTACHMENT

(FRA) (UFO)

DEC 2018

IR 1.0

Scale: 1"=1'-0"

PLAN VIEW, FRA, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, FRA, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 2: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

E

1.1

AS REQUIRED BY

MODULE MANUFACTURER

B

1.1

C

1.1

X

W

IRONRIDGE FRA

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

IRONRIDGE SOUTH TILT LEG

W

C

G

1.4

J

1.4

R

H

1.4

K

1.4

IRONRIDGE RAIL

MEMBRANE FLASHING

VARIES BY ROOF TYPE

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS: FLAT

ROOF

ATTACHMENT

(FRA) (CAMO)

DEC 2018

IR 1.1

Scale: 1"=1'-0"

PLAN VIEW, FRA, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, FRA, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 3: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

1.2

E

1.2

AS REQUIRED BY

MODULE MANUFACTURER

B

1.2

1"

VARIES

XW

C

C

W

R

G

1.4

J

1.4

H

1.4

K

1.4

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

SOUTH TILT LEG

ANGLE OF

SOLAR INCIDENCE

IRONRIDGE FRA

MEMBRANE FLASHING

VARIES BY ROOF TYPE

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS: FLAT

ROOF

ATTACHMENT

(FRA) (UFO)

DEC 2018

IR 1.2

Scale: 1"=1'-0"

SIDE VIEW, FRA, LANDSCAPE MODULE

B

Scale: 1"=1'-0"

SIDE VIEW, FRA, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 4: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

VARIES

XW

C

C

W

R

G

1.4

J

1.4

H

1.4

K

1.4

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

SOUTH TILT LEG

ANGLE OF

SOLAR INCIDENCE

IRONRIDGE FRA

MEMBRANE FLASHING

VARIES BY ROOF TYPE

B

1.3

AS REQUIRED BY

MODULE MANUFACTURER

C

1.3

E

1.3

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS: FLAT

ROOF

ATTACHMENT

(FRA) (CAMO)

DEC 2018

IR 1.3

Scale: 1"=1'-0"

SIDE VIEW, FRA, LANDSCAPE MODULE

B

Scale: 1"=1'-0"

SIDE VIEW, FRA, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 5: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

SELF-DRILLING SCREW

GROUNDING STRAP,

INSTALLED AS NEEDED

1"MIN

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

1'-0"

SELF-DRILLING SCREWN

1.2

Ø12"

Ø7"

1

1

16

"

1"

UNDERMOUNTING SLOT

SIDE-FACING SLOT

TOP-FACING SLOT

INTERNAL SPLICE

IRONRIDGE FRA

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

IRONRIDGE

RAIL

MEMBRANE

FLASHING VARIES

BY ROOF TYPE

IRONRIDGE FRA

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

MEMBRANE

FLASHING VARIES

BY ROOF TYPE

IRONRIDGE FRA

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

IRONRIDGE

RAIL

MEMBRANE

FLASHING VARIES

BY ROOF TYPE

IRONRIDGE FRA

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

MEMBRANE

FLASHING VARIES

BY ROOF TYPE

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF

COMPONENT

DETAILS: FLAT

ROOF

ATTACHMENT

(FRA)

DEC 2018

IR 1.4

6"=1'-0"

DETAIL, SPLICE CONNECTION, IRONRIDGE RAIL

L

1'-0"=1'-0"

DETAIL, INTERNAL SPLICE, IRONRIDGE RAIL

N

6"=1'-0"

DETAIL, EXPANSION JOINT CONNECTION, IRONRIDGE RAIL

M

MEMBRANE FLASHING, PLAN VIEW

S

FRA, PERSPECTIVE VIEW

P

MEMBRANE FLASHING, PLAN VIEW

T

Scale: 3"=1'-0"

STANDOFF DETAIL

G

Scale: 3"=1'-0"

STANDOFF DETAIL

H

Scale: 3"=1'-0"

STANDOFF DETAIL

K

Scale: 3"=1'-0"

STANDOFF DETAIL

J

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

FRA, SIDE VIEW

Q

MEMBRANE FLASHING, SIDE VIEW

R

Page 6: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

B

2.0

C

2.0

AS REQUIRED BY

MODULE MANUFACTURER

E

2.0

1"

IRONRIDGE RAIL

VARIES

G

2.4

XW

ANGLE OF

SOLAR INCIDENCE

C

C

W

IRONRIDGE NORTH TILT LEG

J

2.4

H

2.4

K

2.4

R

POST STANDOFF

IRONRIDGE U-FOOT

IRONRIDGE SOUTH TILT LEG

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

QUICKMOUNT

(UFO)

DEC 2018

IR 2.0

Scale: 1"=1'-0"

PLAN VIEW, QUICKMOUNT, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 7: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

B

2.1

C

2.1

AS REQUIRED BY

MODULE MANUFACTURER

E

2.1

IRONRIDGE RAIL

VARIES

G

2.4

XW

ANGLE OF

SOLAR INCIDENCE

C

C

W

IRONRIDGE NORTH TILT LEG

J

2.4

H

2.4

K

2.4

R

POST STANDOFF

IRONRIDGE U-FOOT

IRONRIDGE SOUTH TILT LEG

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

QUICKMOUNT

(CAMO)

DEC 2018

IR 2.1

Scale: 1"=1'-0"

PLAN VIEW, QUICKMOUNT, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 8: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

2.2

E

2.2

AS REQUIRED BY

MODULE MANUFACTURER

B

2.2

1"

POST STANDOFF

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

VARIES

ANGLE OF

SOLAR INCIDENCE

XW

C

C

W

SOUTH TILT LEG

R

H

2.4

G

2.4

J

2.4

K

2.4

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

QUICKMOUNT

(UFO)

DEC 2018

IR 2.2

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, LANDSCAPE MODULE

B

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 9: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

POST STANDOFF

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

VARIES

ANGLE OF

SOLAR INCIDENCE

XW

C

C

W

SOUTH TILT LEG

R

H

2.4

G

2.4

J

2.4

K

2.4

C

2.3

B

2.3

AS REQUIRED BY

MODULE MANUFACTURER

E

2.3

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

QUICKMOUNT

(CAMO)

DEC 2018

IR 2.3

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, LANDSCAPE MODULE

B

Scale: 1"=1'-0"

SIDE VIEW, QUICKMOUNT, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 10: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

SELF-DRILLING SCREW

GROUNDING STRAP,

INSTALLED AS NEEDED

1"MIN

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

1'-0"

SELF-DRILLING SCREWN

1.2

1

1

2

"

VARIOUS

SIZES

AVAILABLE

5/16" LAG BOLT

BY OTHERS

1

1

4

"

3

7

8

"

UNDERMOUNTING SLOT

SIDE-FACING SLOT

TOP-FACING SLOT

INTERNAL SPLICE

(E) ROOF

POST

STANDOFF

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

(E) ROOF

POST

STANDOFF

IRONRIDGE

NORTH

TILT LEG

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

(E) ROOF

POST

STANDOFF

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

(E) ROOF

POST

STANDOFF

IRONRIDGE

SOUTH

TILT LEG

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF

COMPONENT

DETAILS:

QUICKMOUNT

DEC 2018

IR 2.4

6"=1'-0"

DETAIL, SPLICE CONNECTION, IRONRIDGE RAIL

L

1'-0"=1'-0"

DETAIL, INTERNAL SPLICE, IRONRIDGE RAIL

N

6"=1'-0"

DETAIL, EXPANSION JOINT CONNECTION, IRONRIDGE RAIL

M

QUICKMOUNT ALUM. STANDOFF, PLAN VIEW

Q

QUICKMOUNT ALUMINUM STANDOFF

P

QUICKMOUNT ALUM. STANDOFF, SIDE VIEW

R

Scale: 3"=1'-0"

STANDOFF DETAIL

G

Scale: 3"=1'-0"

STANDOFF DETAIL

H

Scale: 3"=1'-0"

STANDOFF DETAIL

K

Scale: 3"=1'-0"

STANDOFF DETAIL

J

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 11: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

3.0

E

3.0

AS REQUIRED BY

MODULE MANUFACTURER

B

3.0

1"

XW

U-ANCHOR 2000

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

IRONRIDGE SOUTH TILT LEG

W

C

G

3.4

J

3.4

R

H

3.4

K

3.4

IRONRIDGE RAIL

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2000

(UFO)

DEC 2018

IR 3.0

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2000, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2000, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 12: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

E

3.1

AS REQUIRED BY

MODULE MANUFACTURER

B

3.1

C

3.1

XW

U-ANCHOR 2000

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

IRONRIDGE SOUTH TILT LEG

C

W

H

3.4

K

3.4

R

G

3.4

J

3.4

IRONRIDGE RAIL

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2000

(CAMO)

DEC 2018

IR 3.1

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2000, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2000, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 13: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

C

3.2

E

3.2

AS REQUIRED BY

MODULE MANUFACTURER

B

3.2

1"

VARIES

XW

C

C

W

R

G

3.4

J

3.4

H

3.4

K

3.4

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

SOUTH TILT LEG

ANGLE OF

SOLAR INCIDENCE

U-ANCHOR 2000

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2000

(UFO)

DEC 2018

IR 3.2

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2000, LANDSCAPE MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2000, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 14: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) FRONT

IRONRIDGE CAMO

END CLAMP

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP (CAMO) PLAN

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

VARIES

XW

C

C

W

R

G

3.4

J

3.4

H

3.4

K

3.4

IRONRIDGE RAIL

NORTH TILT LEG

IRONRIDGE U-FOOT

SOUTH TILT LEG

ANGLE OF

SOLAR INCIDENCE

U-ANCHOR 2000

B

3.3

C

3.3

E

3.3

AS REQUIRED BY

MODULE MANUFACTURER

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2000

(CAMO)

DEC 2018

IR 3.3

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2000, LANDSCAPE MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2000, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 15: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

SELF-DRILLING SCREW

GROUNDING STRAP,

INSTALLED AS NEEDED

1"MIN

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

1'-0"

SELF-DRILLING SCREWN

2.2

1'-3

3

4

"

1'-3

3

4

"

6

1

2

"

5

16

"

1"

UNDERMOUNTING SLOT

SIDE-FACING SLOT

TOP-FACING SLOT

INTERNAL SPLICE

(E) ROOF

MEMBRANE,

FULLY

ADHERED

U-ANCHOR 2000

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

IRONRIDGE

RAIL

(E) ROOF

MEMBRANE,

FULLY

ADHERED

U-ANCHOR 2000

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

(E) ROOF

MEMBRANE,

FULLY

ADHERED

U-ANCHOR 2000

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

IRONRIDGE

RAIL

(E) ROOF

MEMBRANE,

FULLY

ADHERED

U-ANCHOR 2000

IRONRIDGE

RAIL

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF

COMPONENT

DETAILS:

U-ANCHOR 2000

DEC 2018

IR 3.4

6"=1'-0"

DETAIL, SPLICE CONNECTION, IRONRIDGE

L

1'-0"=1'-0"

DETAIL, INTERNAL SPLICE, IRONRIDGE RAIL

N

6"=1'-0"

DETAIL, EXPANSION JOINT CONNECTION, IRONRIDGE RAIL

M

Scale: 3"=1'-0"

STANDOFF DETAIL

G

Scale: 3"=1'-0"

STANDOFF DETAIL

H

Scale: 3"=1'-0"

STANDOFF DETAIL

K

Scale: 3"=1'-0"

STANDOFF DETAIL

J

U-ANCHOR 2000, SIDE VIEW

T

U-ANCHOR 2000, PLAN VIEW

S

U-ANCHOR TARGET PLATE

R

U-ANCHOR 2000, PERSPECTIVE VIEW

Q

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 16: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

4.0

AS REQUIRED BY

MODULE MANUFACTURER

B

4.0

E

4.0

1"

XW

U-ANCHOR 2400

IRONRIDGE SOUTH TILT LEG

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

C

W

IRONRIDGE RAIL

G

4.4

J

4.4

H

4.4

K

4.4

R

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2400

(UFO)

DEC 2018

IR 4.0

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2400, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2400, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 17: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

IRONRIDGE CAMO

END CLAMP

PV MODULE FRAME

IRONRIDGE RAIL

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

B

4.1

E

4.1

C

4.1

AS REQUIRED BY

MODULE MANUFACTURER

XW

U-ANCHOR 2400

IRONRIDGE SOUTH TILT LEG

IRONRIDGE NORTH TILT LEG

IRONRIDGE U-FOOT

ANGLE OF

SOLAR INCIDENCE

C

C

W

IRONRIDGE RAIL

R

G

4.4

J

4.4

H

4.4

K

4.4

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2400

(CAMO)

DEC 2018

IR 4.1

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2400, PORTRAIT MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2400, PORTRAIT MODULE

B

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 18: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

C

4.2

E

4.2

AS REQUIRED BY

MODULE MANUFACTURER

B

4.2

1"

IRONRIDGE RAIL

VARIES

ANGLE OF

SOLAR INCIDENCE

XW

C

C

W

NORTH TILT LEG

IRONRIDGE U-FOOT

SOUTH TILT LEG

R

G

4.4

J

4.4

H

4.4

K

4.4

U-ANCHOR 2400

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP PLAN

IRONRIDGE STOPPER

SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, END CLAMP FRONT

IRONRIDGE STOPPER SLEEVE

IRONRIDGE UNIVERSAL

FASTENING OBJECT

1"

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2400

(UFO)

DEC 2018

IR 4.2

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2400, LANDSCAPE MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2400, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (UFO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 19: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

PV MODULE FRAME

DETAIL, MID CLAMP PLAN

IRONRIDGE UNIVERSAL

FASTENING OBJECT

3

8

"

PV MODULE FRAME

IRONRIDGE RAIL

DETAIL, MID CLAMP FRONT

IRONRIDGE UNIVERSAL

FASTENING OBJECT

PV MODULE FRAME

IRONRIDGE RAIL

IRONRIDGE CAMO

END CLAMP

PV MODULE FRAME

IRONRIDGE RAIL

IRONRIDGE CAMO

END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

IRONRIDGE RAIL

VARIES

ANGLE OF

SOLAR INCIDENCE

XW

C

C

W

SOUTH TILT LEG

NORTH TILT LEG

IRONRIDGE U-FOOT

R

G

4.4

J

4.4

H

4.4

K

4.4

U-ANCHOR 2400

C

4.3

AS REQUIRED BY

MODULE MANUFACTURER

B

4.3

E

4.3

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF PV

SYSTEM

DETAILS:

U-ANCHOR 2400

(CAMO)

DEC 2018

IR 4.3

Scale: 1"=1'-0"

PLAN VIEW, U-ANCHOR 2400, LANDSCAPE MODULE

A

Scale: 1"=1'-0"

SIDE VIEW, U-ANCHOR 2400, LANDSCAPE MODULE

B

Scale: 6"=1'-0"

DETAIL, MID CLAMP PLAN

C

Scale: 6"=1'-0"

DETAIL, MID CLAMP FRONT

D

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) PLAN

E

Scale: 6"=1'-0"

DETAIL, END CLAMP (CAMO) FRONT

F

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M

Page 20: DETAIL, MID CLAMP PLAN DETAIL, MID CLAMP FRONT ...files.ironridge.com/flat-roof-mounting/resources/cutsheets/FR-AutoCAD-PDF.pdf · membrane flashing varies by roof type pv module

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

SELF-DRILLING SCREW

GROUNDING STRAP,

INSTALLED AS NEEDED

1"MIN

IRONRIDGE RAIL

IRONRIDGE INTERNAL SPLICE

1'-0"

SELF-DRILLING SCREWN

3.2

11

3

4

"

11

3

4

"

6

1

2

"

5

16

"

1"

FASTENERS DEFINED

BY OTHERS

UNDERMOUNTING SLOT

SIDE-FACING SLOT

TOP-FACING SLOT

INTERNAL SPLICE

FASTENERS

DEFINED BY

OTHERS

(E) ROOF

MEMBRANE,

MECHANICALLY

ATTACHED

U-ANCHOR 2400

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

IRONRIDGE

RAIL

(E) ROOF

MEMBRANE,

MECHANICALLY

ATTACHED

U-ANCHOR 2400

PV MODULE,

BY OTHERS

IRONRIDGE

NORTH

TILT LEG

IRONRIDGE

RAIL

FASTENERS

DEFINED BY

OTHERS

(E) ROOF

MEMBRANE,

MECHANICALLY

ATTACHED

U-ANCHOR 2400

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

IRONRIDGE

RAIL

(E) ROOF

MEMBRANE,

MECHANICALLY

ATTACHED

U-ANCHOR 2400

PV MODULE,

BY OTHERS

IRONRIDGE

SOUTH

TILT LEG

IRONRIDGE

RAIL

SHEET NAME

JOB NO.

ISSUE DATE

SHEET NO.

SHEET SIZE

24X36

1495 Z

EP

HY

R A

VE

, H

AY

WA

RD

, C

A 9454

4

80

0.227.95

23 IR

ON

RID

GE

.C

OM

N

O

T

F

O

R

C

O

N

S

T

R

U

C

T

I

O

N

REVISION HISTORY

APPROVAL STATUS

REV DESCRIPTION DATE

3.0 FR

FLAT ROOF

COMPONENT

DETAILS:

U-ANCHOR 2400

DEC 2018

IR 4.4

6"=1'-0"

DETAIL, SPLICE CONNECTION, IRONRIDGE RAIL

L

1'-0"=1'-0"

DETAIL, INTERNAL SPLICE, IRONRIDGE RAIL

N

6"=1'-0"

DETAIL, EXPANSION JOINT CONNECTION, IRONRIDGE RAIL

M

Scale: 3"=1'-0"

STANDOFF DETAIL

G

Scale: 3"=1'-0"

STANDOFF DETAIL

H

Scale: 3"=1'-0"

STANDOFF DETAIL

K

Scale: 3"=1'-0"

STANDOFF DETAIL

J

U-ANCHOR 2400, SIDE VIEW

T

U-ANCHOR 2400, PLAN VIEW

S

U-ANCHOR TARGET PLATE

R

U-ANCHOR 2400, PERSPECTIVE VIEW

Q

SN

OW

L

OA

D, P

SF

EX

PO

SU

RE

C

AT

MO

DU

LE

T

YP

E

RIS

K C

AT

WIN

D S

PE

ED

, M

PH

MO

DU

LE

W

D

C

MO

DU

LE

Q

TY

- - - -

60

-C

EL

L, G

EN

ER

IC

- -

CL

IE

NT

N

AM

E

PR

OJE

CT

N

AM

E

PR

OJE

CT

AD

DR

ES

S

SY

ST

EM

K

W D

C

IR

ON

RID

GE

FL

AT

R

OO

F M

OU

NT

S

YS

TE

M