3
0° 00' 59" 220.89' S E 0° 00' 59" 220.89' N W 89° 59' 32" 165.00' N W 89° 59' 32" 165.00' S E 400 WEST (E) POWER POLE PROPOSED FIRE HYDRANT LOCATION UNIT 1 UNIT 1 UNIT 1 UNIT 1A 17'-4" 8'-8" UNIT 1 UNIT 1 UNIT 1 UNIT 1B UNIT 1 UNIT 1 UNIT 1 UNIT 1A UNIT 1 UNIT 1 UNIT 1 UNIT 1A BIKE RACK BIKE RACK (E) POWER POLE (E) POWER POLE PROPOSED TRANSFORMER LOCATION UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 UNIT 1 25'-0" 24'-0" 13'-2" 14'-3" 25'-0" 24'-0" BUILDING A BUILDING B BUILDING C BUILDING D 2 4 1 5 4 TYP. 3 3 TYP. 3 3 6 6 6 6 5 TYP. 5 TYP. 5 TYP. SETBACK 10'-0" SETBACK 10'-0" SETBACK 10'-0" SETBACK 15'-0" 140'-0" 7 1/2" 34'-4" 2'-0" 20'-0" 2'-0" 33'-4 1/2" 14'-8" 34'-10 1/2" 2'-0" 20'-0" 2'-0" 34'-10 1/2" 1 5/8" F E E D D NOTES: 1. FINISH GRADE SHALL HAVE A SLOPE AWAY FROM THE BUILDING OF 6" MINIMUM FOR THE FIRST TEN FEET AND A 2% SLOPE THEREAFTER. ALL DRAINAGE FROM LOT SHALL DRAIN INTO AN APPROVED DRAINAGE SYSTEM. ALL EARTH FILL TO RECEIVE CONCRETE FLOORS, WALKS, DRIVES, ETC., SHALL BE SETTLED AND TAMPED TO 90% MINIMUM COMPACTION. 2. ALL FOUNDATION HEIGHTS GIVEN ARE BASED ON OWNER / CONTRACTOR PROVIDED DATA. ACTUAL HEIGHTS SHALL BE FIELD VERIFIED AND COORDINATED THROUGHOUT TO ENSURE THE RESIDENCE AND SURROUNDING GRADE DO NOT POSE A WATER RISK TO THE RESIDENCE AND THE SURROUNDING RESIDENCES. 3. RETAINING SHOWN SHALL BE FIELD VERIFIED. 4' MAX. LIFTS UNLESS ENGINEERED BY A CIVIL ENGINEER. 4. CONTRACTOR SHALL CONSULT GEO-TECHNICAL REPORT AND IMPLEMENT ALL REQUIREMENTS. © COPYRIGHT DESIGN WEST ARCHITECTS 2019 5 4 3 2 1 A B D C design west architects 255 SOUTH 300 WEST 795 NORTH 400 WEST LOGAN UT 84321 SALT LAKE CITY UT 84103 PROJECT #: DRAWN BY: CHECKED BY: ISSUED: OF 055 4/21/2021 1:23:31 PM TAG SLC - 765 NORTH APARTMENTS SALT LAKE CITY, UT 519057 HARMISON DC XX.XX.XXXX ARCHITECTURAL SITE PLAN A-003 NOT FOR CONSTRUCTION TAG - SLC 3/32" = 1'-0" A1 ARCHITECTURAL SITE PLAN SITE PLAN KEYED NOTES MARK DESCRIPTION 1 AC CONDENSING UNIT. APPROXIMATE LOCATION SHOWN 2 CONC SIDEWALK. SEE CIVIL 3 CONC DRIVEWAY. SEE CIVIL 4 BIKE RACK. SEE CIVIL 5 GAS METER AND DISCONNECTS - APPROXIMATE LOCATION SHOWN 6 ELECTRICAL METER AND DISCONNECTS - APPROXIMATE LOCATION SHOWN MARK: DATE: DESCRIPTION:

Transcript of design west - slcdocs.com

Page 1: design west - slcdocs.com

0° 0

0' 5

9"22

0.89

'S

E

0° 0

0' 5

9"22

0.89

'N

W

89° 59' 32"165.00'

N W

89° 59' 32"165.00'

S E

400

WES

T

(E) POWER POLE

PROPOSED FIRE HYDRANT LOCATION

UNIT 1UNIT 1UNIT 1 UNIT 1A

17'-4

"

8'-8"

UNIT 1UNIT 1UNIT 1 UNIT 1B

UNIT 1UNIT 1UNIT 1 UNIT 1A

UNIT 1UNIT 1UNIT 1 UNIT 1A

BIKE RACK

BIKE RACK

(E) POWER POLE

(E) POWER POLE

PROPOSED TRANSFORMER

LOCATION

UNIT 1 UNIT 1 UNIT 1

UNIT 1UNIT 1UNIT 1

UNIT 1UNIT 1UNIT 1

UNIT 1UNIT 1UNIT 1

25'-0

"

24'-0

"

13'-2

"

14'-3

"

25'-0

"

24'-0

"

BUILDING A

BUILDING B

BUILDING C

BUILDING D

2

4

1

5

4

TYP.

3

3

TYP.

3

3

6

6

6

6

5TYP.

5TYP.

5TYP.

SETBACK

10'-0"

SETB

ACK

10'-0

"

SETB

ACK

10'-0

"

SETBACK

15'-0" 140'-0"

7 1/

2"34

'-4"

2'-0"

20'-0

"2'-

0"33

'-4 1

/2"

14'-8

"34

'-10

1/2"

2'-0"

20'-0

"2'-

0"34

'-10

1/2"

1 5/

8"

F FE E

DD

NOTES:1. FINISH GRADE SHALL HAVE A SLOPE AWAY FROM THE BUILDING OF 6"

MINIMUM FOR THE FIRST TEN FEET AND A 2% SLOPE THEREAFTER. ALLDRAINAGE FROM LOT SHALL DRAIN INTO AN APPROVED DRAINAGE SYSTEM. ALL EARTH FILL TO RECEIVE CONCRETE FLOORS, WALKS, DRIVES, ETC.,SHALL BE SETTLED AND TAMPED TO 90% MINIMUM COMPACTION.

2. ALL FOUNDATION HEIGHTS GIVEN ARE BASED ON OWNER / CONTRACTOR PROVIDED DATA. ACTUAL HEIGHTS SHALL BE FIELD VERIFIED ANDCOORDINATED THROUGHOUT TO ENSURE THE RESIDENCE ANDSURROUNDING GRADE DO NOT POSE A WATER RISK TO THE RESIDENCE AND THE SURROUNDING RESIDENCES.

3. RETAINING SHOWN SHALL BE FIELD VERIFIED. 4' MAX. LIFTS UNLESSENGINEERED BY A CIVIL ENGINEER.

4. CONTRACTOR SHALL CONSULT GEO-TECHNICAL REPORT AND IMPLEMENT ALL REQUIREMENTS.

© COPYRIGHT DESIGN WEST ARCHITECTS 201954321

A

B

D

C

desi

gn w

est

arch

itect

s25

5 SO

UTH

300

WES

T79

5 NO

RTH

400

WES

TLO

GAN

UT

843

21SA

LT L

AKE

CITY

UT

841

03

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

OF 055

4/21/2

021 1

:23:31

PM

TAG

SLC

-765

NOR

TH A

PART

MEN

TS

SALT

LAK

E CI

TY, U

T

519057

HARMISON

DC

XX.XX.XXXX

ARCHITECTURALSITE PLAN

A-003

NO

T FO

R C

ON

STR

UC

TIO

N

TAG

-SLC

3/32" = 1'-0"

A1 ARCHITECTURAL SITE PLAN

SITE PLAN KEYED NOTES

MARK DESCRIPTION

1 AC CONDENSING UNIT. APPROXIMATE LOCATION SHOWN2 CONC SIDEWALK. SEE CIVIL3 CONC DRIVEWAY. SEE CIVIL4 BIKE RACK. SEE CIVIL5 GAS METER AND DISCONNECTS - APPROXIMATE LOCATION SHOWN6 ELECTRICAL METER AND DISCONNECTS - APPROXIMATE LOCATION SHOWN

MARK

:DA

TE:

DESC

RIPT

ION:

Page 2: design west - slcdocs.com

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

T.O. FOUNDATION99'-8"

F E D

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

T.O. FOUNDATION99'-8"

FED

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

12345678

T.O. FOUNDATION99'-8"

TYP.

TYP.

TYP.

TYP.

TYP.

TYP. TYP.

1

11 9

4

7 8

2

10 7

6

3 16

FINISH FLOOR - LEVEL 1100'-0"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

1 2 3 4 5 6 7 8

T.O. FOUNDATION99'-8"

ELEVATION LEGEND:

ARCHITECTURAL ASPHALT SHINGLES

ALL COLORS AS SELECTED BY OWNER

STUCCO FINISH, COLOR PER OWNER. INSTALL PER

MANUFACTURERS RECOMENDATIONS

ALL COLORS AS SELECTED BY OWNER

FIBER CEMENT LAP SIDING

ALL COLORS AS SELECTED BY OWNER

NOTE:

SEE A3/A-601 FOR WINDOW TRIM DETAILS

© COPYRIGHT DESIGN WEST ARCHITECTS 201954321

A

B

D

C

desi

gn w

est

arch

itect

s

255

SOU

TH 3

00 W

EST

795

NO

RTH

400

WES

TLO

GAN

UT

843

21SA

LT L

AKE

CIT

Y U

T 8

4103

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

OF 055

4/2

7/2

021 1

1:0

5:1

8 A

M

TAG

SLC

-76

5 N

OR

TH A

PAR

TMEN

TS

SALT

LA

KE C

ITY,

UT

8410

3

519057

XX

XX

04-23-2021

EXTERIORELEVATIONS (BLDGB)

A-220

PE

RM

IT S

ET

TAG

-SL

C

765

NO

RTH

400

WES

T

1/8" = 1'-0"

B4 BLDG B STREET ELEVATION

1/8" = 1'-0"

A4 BLDG B SIDE ELEVATION

1/8" = 1'-0"

B1 BLDG B REAR ELEVATION

1/8" = 1'-0"

A1 BLDG B FRONT ELEVATION

MA

RK

:D

AT

E:

DE

SC

RIP

TIO

N:

ELEVATION KEYED NOTES

MARK DESCRIPTION

1 FINISH GRADE, COORDINATE WITH CIVIL

2 "V" GROOVE EXPANSION JOINT

3 FIBER CEMENT TRIM

4 WINDOW TRIM @ WINDOW. SEE DETAIL A3/A-601,SIM AT DOOR HEADS AND JAMBS

5 FIBER CEMENT SIDING, MITER JOINTS AT OUTSIDECORNER

6 MECHANICAL FLUE (GRAPHICAL REPRESENTATIONONLY), EXTEND BEYOND ROOF PER CODE, FLASH ASREQ'D

7 BATHROOM EXHAUST VENT- COLOR: TBD

8 RANGE EXHAUST VENT- COLOR: TBD

9 MECHANICAL OUTSIDE AIR INTAKE, PROVIDE GRILLAND SCREEN - COLOR: TBD

10 DRYER EXHAUST VENT- COLOR: TBD

11 BOLLARD, SEE DETAIL C5/A-550

12 ADDRESS LETTERING SHALL BE 6" HIGH AND ASTROKE WIDTH NOT LESS THAN 1/2." ADDRESSNUMBERS SHALL BE ARABIC NUMBERS. ADDRESSSHALL BE CONTRASTING COLOR OF BACKGROUND

13 HOSE BIBB. TO BE FROST PROOF AND EQUIPPEDWITH VACUUM BREAKER

14 PRE-FINISHED ALUMINIUM GUTTER

15 PRE-FINISHED ALUMINIUM DOWNSPOUT WITHSPLASH BLOCK

16 SCUPPER WITH DOWNSPOUT - CONNECT PER CIVIL

Page 3: design west - slcdocs.com

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

A1

A-321

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

CB A

T.O. FOUNDATION99'-8"

1

2TYP

3

4

5

XXXX

12

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

C1

A-321

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

12345678

T.O. FOUNDATION99'-8"

1

2TYP.

3

4

5

13TYP

C3

A-321

14TYP.

15TYP.

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

C1

A-321

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

1 2 3 4 5 6 7 8

T.O. FOUNDATION99'-8"

1

2TYP.

3

4

9TYP.

8TYP.

11TYP.

C3

A-321

16

7TYP.

10TYP.

7TYP.

6

1616161616

FINISH FLOOR - LEVEL 1100'-0"

FTG-FND PLAN96'-0"

TOP OF BLDG138'-8 1/2"

FINISH FLOOR - LEVEL 2110'-2 3/4"

FINISH FLOOR - LEVEL 3120'-5 1/2"

A1

A-321

T.O. WALL - LEVEL 1109'-0"

T.O. WALL - LEVEL 2119'-2 3/4"

T.O. WALL - LEVEL 3129'-5 1/2"

CBA

T.O. FOUNDATION99'-8"

1

2TYP

ELEVATION LEGEND:

ARCHITECTURAL ASPHALT SHINGLES

ALL COLORS AS SELECTED BY OWNER

STUCCO FINISH, COLOR PER OWNER. INSTALL PER

MANUFACTURERS RECOMENDATIONS

ALL COLORS AS SELECTED BY OWNER

FIBER CEMENT LAP SIDING

ALL COLORS AS SELECTED BY OWNER

NOTE:

SEE A3/A-601 FOR WINDOW TRIM DETAILS

© COPYRIGHT DESIGN WEST ARCHITECTS 201954321

A

B

D

C

desi

gn w

est

arch

itect

s

255

SOU

TH 3

00 W

EST

795

NO

RTH

400

WES

TLO

GAN

UT

843

21SA

LT L

AKE

CIT

Y U

T 8

4103

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

OF 055

4/2

7/2

021 1

1:0

4:5

7 A

M

TAG

SLC

-76

5 N

OR

TH A

PAR

TMEN

TS

SALT

LA

KE C

ITY,

UT

8410

3

519057

XX

XX

04-23-2021

EXTERIORELEVATIONS (BLDGA & C)

A-120

PE

RM

IT S

ET

TAG

-SL

C

765

NO

RTH

400

WES

T

1/8" = 1'-0"

A4 BLDG A & C STREET ELEVATION

1/8" = 1'-0"

A1 BLDG A & C FRONT ELEVATION

1/8" = 1'-0"

B1 BLDG A & C REAR ELEVATION

1/8" = 1'-0"

B4 BLDG A & C SIDE ELEVATION

ELEVATION KEYED NOTES

MARK DESCRIPTION

1 FINISH GRADE, COORDINATE WITH CIVIL

2 "V" GROOVE EXPANSION JOINT

3 FIBER CEMENT TRIM

4 WINDOW TRIM @ WINDOW. SEE DETAIL A3/A-601,SIM AT DOOR HEADS AND JAMBS

5 FIBER CEMENT SIDING, MITER JOINTS AT OUTSIDECORNER

6 MECHANICAL FLUE (GRAPHICAL REPRESENTATIONONLY), EXTEND BEYOND ROOF PER CODE, FLASH ASREQ'D

7 BATHROOM EXHAUST VENT- COLOR: TBD

8 RANGE EXHAUST VENT- COLOR: TBD

9 MECHANICAL OUTSIDE AIR INTAKE, PROVIDE GRILLAND SCREEN - COLOR: TBD

10 DRYER EXHAUST VENT- COLOR: TBD

11 BOLLARD, SEE DETAIL C5/A-550

12 ADDRESS LETTERING SHALL BE 6" HIGH AND ASTROKE WIDTH NOT LESS THAN 1/2." ADDRESSNUMBERS SHALL BE ARABIC NUMBERS. ADDRESSSHALL BE CONTRASTING COLOR OF BACKGROUND

13 HOSE BIBB. TO BE FROST PROOF AND EQUIPPEDWITH VACUUM BREAKER

14 PRE-FINISHED ALUMINIUM GUTTER

15 PRE-FINISHED ALUMINIUM DOWNSPOUT WITHSPLASH BLOCK

16 SCUPPER WITH DOWNSPOUT - CONNECT PER CIVIL

MA

RK

:D

AT

E:

DE

SC

RIP

TIO

N: