Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ......

17
Design • Build • Deliver Padmounted Primary Metering Gear, 5-35kV Live Front Dead Front Single- or Three-Phase Configurations With Powergrid Solution’s Primary Metering Gear, customers can safely meter voltages from 5-35 kV and reliably measure power usage. Powergrid Solution’s equipment comes assembled and ready for installation, saving you time and money on-site. Live Front and Dead Front units are available in single or three-phase configurations, loop or radial feeds, with 200 or 600 Amp bushings standard, upgradeable to 1200 Amp. Order the cabinets alone, or have Powergrid Solutions source, supply and install instrument trans- formers.

Transcript of Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ......

Page 1: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

Design • Build • Deliver

Padmounted Primary Metering Gear, 5-35kVLive Front • Dead Front • Single- or Three-Phase Configurations

With Powergrid Solution’s Primary

Metering Gear, customers can

safely meter voltages from 5-35 kV

and reliably measure power usage.

Powergrid Solution’s equipment

comes assembled and ready for

installation, saving you time and

money on-site.

Live Front and Dead Front units are

available in single or three-phase

configurations, loop or radial feeds,

with 200 or 600 Amp bushings

standard, upgradeable to 1200

Amp. Order the cabinets alone, or

have Powergrid Solutions source,

supply and install instrument trans-

formers.

larryjohannson
Repped by: logo
Page 2: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

For more information, please visit our Web site, contact our sales network or re

Padmounted Primary Metering Gear, 5-35kVLive Front • Dead Front • Single or Three-Phase Configurations

ModelsSPMD, SPML, SPMG

Standard Features200 or 600 AmpPaint meeting IEEE C57.12.28Mild steelCopper bus (silver- or tin-plated)Custom paint colors (when specified at time of order)GPO-3 glass polyester or clear Lexan® barriersIndoor or outdoor instrument transformersLifting lugsLoop/radial feedsMimic busPenta head latch (3-point, dual-action, positive verification latch)Cross kinked roofStainless steel backing screens on louversStainless steel exterior hardwareStainless steel parking standsWelded construction

Customization Options1200 AmpGalvanneal. aluminum or stainless steel constructionBase undercoatingContinuous and concentric ground busExtended elbow compartment depth (dead front)Instrument transformers installed (Powergrid Solutions or customer-supplied)Insulating non-drip compound (inside roof)Low-voltage wiring (color-coded, standard)Meter base and test block enclosure with plywood sub-panelMeter sockets installed (Powergrid Solutions or customer-supplied)Multi-lingual exterior/interior signagePartially-hinged roof or fully-removable roofTest blocks installed (Powergrid Solutions or customer-supplied)

The Powergrid Solutions DifferenceA major U.S. utility wanted to save time and money by sourcing empty Powergrid SolutionsPadmounted Primary Metering enclosures. The customer planned to install components and wire the units in their facility. However, component delivery and installations were fraught with logistics and lead-time problems.

Ultimately, the utility opted to source completed Padmounted Primary Metering gear fromPowergrid Solutions, including instrument transformers, meter sockets, test blocks and low-voltage wiring. Powergrid Solution’s integrated manufacturing proved to be the most cost-effec-tive and timely method, making Powergrid Solutions the utility’s preferred provider.

larryjohannson
Represented By
Page 3: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.1

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Non-Fused.

Application: Powergrid Solutions (PSI) Padmount Primary Metering cabinets offer Commercial, Industrial, and Utility Customers a solution for revenue metering of primary voltages. Padmount primary metering cabinets are used throughout underground power systems where metering of primary voltages is necessary such as large plants, universities, and utility power supplies. Powergrid Solutions Padmount Primary Metering cabinets can be supplied fully equipped with current transformers (CT’s), potential transformers (PT’s), Meter Socket, and Test Switch completely wired and tested per the Customers’ requirements which allows for fast field installation. PSI can supply transformers to meet the customer specifications or, if it is preferred, the Customer can provide PSI with transformers to install and wire into the enclosure. PSI Padmount Primary Metering gear is available to meter medium voltages ranging from 5kV to 35kV and up to 600 amps. PSI Padmount Primary Metering Cabinets are available in a variety of sizes and construction features to meet customer and environmental requirements. The PSI design fully meets and exceeds all IEEE and ANSI standards.

SPMD SPMD

SPMG

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 4: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

PADMOUNTED PRIMARY METERING GEAR CONSTRUCTION FEATURES

4.1.2 © 2015 Powergrid Solutions Inc.

Catalog Version 2.1.1 To find a listing for your local Powergrid Solutions

representative, log on to www.powergridsolutionsinc.com

3

5

2

4 10

8

1. Lifting provisions with removable lifting plates and blind-tapped bolt holes.

2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position.

3. 3-point positive mechanism with recessed penta-bolt

4. Door Stay Arms

5. Cross Kinked Roof

6. “No-Drip” insulating compound on inside of roof

7. Manufacture’s data plate, noncorrosive, stamped and attached to enclosure.

8. Warning and identification labels per IEEE, NEC & NFPA.

9. All-welded construction.

10. 200 amp bushing wells or 600 amp bushings (Deadfront Only)

11. Transformer Mounting Strut

12. 3/16” GPO Phase Barriers

13. Meter Socket and Test Switch (Option)

14. Shorting and Terminal Block (Option)

15. Stainless Steel Parking Stands

16. Phase Identification Labels

17. Screened Tamper Proof Louvers

15

16

17

Page 5: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

PADMOUNTED PRIMARY METERING GEAR CONSTRUCTION FEATURES

4.1.3 © 2015 Powergrid Solutions Inc.

Catalog Version 2.1.1 To find a listing for your local Powergrid Solutions

representative, log on to www.powergridsolutionsinc.com

3

5

2

4 12

8

17

1. Lifting provisions with removable lifting plates and blind-tapped bolt holes.

2. Stainless steel hinges, loose joint pin, allows doors to be removed in the open position.

3. 3-point positive mechanism with recessed penta-bolt

4. Door Stay Arms

5. Cross Kinked Roof

6. “No-Drip” insulating compound on inside of roof

7. Manufacture’s data plate, noncorrosive, stamped and attached to enclosure.

8. Warning and identification labels per IEEE, NEC & NFPA.

9. All-welded construction.

10. 200 amp bushing wells or 600 amp bushings (Deadfront Only)

11. Transformer Mounting Strut

12. 3/16” GPO Phase Barriers

13. Meter Socket and Test Switch (Option)

14. Shorting and Terminal Block (Option)

15. Stainless Steel Parking Stands

16. Phase Identification Labels

17. Screened Tamper Proof Louvers

Page 6: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

EXAMPLE: SPMD-31522-62-MS-XXXX PAD-MOUNT, DEADFRONT PRIMARY METERING CABINET, 3 PHASE, 15 KV, WITH 2-600 AMP BUSHINGS AND 2-200 AMP BUSHING WELLS PER PHASE, CABINET IS CONSTRUCTED OF MILD STEEL.

AL - ALUMINUM GA - GALVANNEAL MS - MILD STEEL SS - STAINLESS STEEL

4.1.4

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Non-Fused.

Catalog Number Selection Sheet. To be used in conjunction with Factory Check Sheet.

MODEL STYLE

ENCLOSURE MATERIAL

AMPERAGE, LOAD TERMINALS (MAX)

AMPERAGE, LINE TERMINALS (MAX)

PH

AS

E

1 2 3

05 15 25 35

VO

LTA

GE

(KV

)

NUMBER OF LINE

TERMINALS

2 - 200 AMP 6 - 600 AMP

SPECIAL DESIGNATIONS SPMD

SPMG

NUMBER OF LOAD

TERMINALS

2 - 200 AMP 6 - 600 AMP

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 7: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.5

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD and SPMG, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Non-Fused.

Factory Check Sheet. To be used in conjunction with Catalog Number Selection Sheet.

RATINGS: Nominal System Voltage/ ______ / ______ kV

Maximum Design Voltage □ 5 kV, 60 kV BIL

Basic Insulation Level (BIL) □ 15 kV, 95 kV BIL

□ 25 kV, 125 kV BIL

□ 35 kV, 150 kV BIL

□ Other ___ kV, ___ kV BIL

Continuous Current (Line) □ 200 amp

□ 600 amp

□ 1200 amp (consult factory)

Continuous Current (Load) □ 200 amp

□ 600 amp ENCLOSURE: Material:

□ A36 Mild Steel

□ A60 Galvanneal Steel

□ 304 L Stainless Steel

□ 5052-H32 Aluminum

Paint Finish:

□ Green. Munsell No., 7GY 3.29/1.5

□ Gray (ANSI 70). Munsell No., 8.3G 7.0/0.4

□ Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54

□ Other: ___________________ 3-Point Latch Type:

□ Penta-Head Bolt

□ Hex-Head Bolt Metering Compartment Barriers, (Model SPMD only):

□ 3/16”, Glass Reinforced Polyester, (standard).

□ 1/4”, Clear Polycarbonate (Lexan), Replaces 3/16” Glass Reinforced Polyester Compartment Barriers. Instrumental Transformers:

□ Current Transformers: Manufacturer: ____, Model: ____, Type: ____, kV: ____, Ratio: ____.

□ Potential Transformers: Manufacturer: ____, Model: ____, Type: ____, kV: ____, Ratio: ____.

□ Meter Socket: Manufacturer: ____, Model: ____, Type: ____.

□ Louvers for enclosure ventilation.

□ Insulation “No-Drip” Compound. Applied to the inside surface of the enclosure roof to prevent condensation.

□ Base Undercoating. Applied to the bottom 2” of the enclosure. (Not required for Stainless Steel enclosures.)

□ Terminal Adapters. Allows “ piggybacking” of cables in switch and bus compartments.

□ Ground Bails. (Located on the Deadfront, Model SPMD only).

□ Interface Bushing Well Inserts. (200 amp only).

□ Specials: ____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 8: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.6

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD, 5-35 kV. 200 and 600 Ampere. Single and Three Phase, Fused/Non-Fused.

For 5 kV applications, use 15 kV table.

Units available as enclosures only (Customer supplied and installed component) or as complete units from the factory.

For single phase units, special configurations and sizes, consult factory.

FRONT VIEW EXPOSED

BASE PLAN

SIDE VIEW EXPOSED

BACK VIEW EXPOSED

STYLE KV H W D H1 H2 SPMD – 115 15 48" 36" 54" 22.00" 8.00"

SPMD – 125 25 54" 36" 54" 22.00" 8.00"

SPMD – 135 35 Consult Factory

SPMD – 315 15 48" 72" 54" 22.00" 8.00"

SPMD – 325 25 54" 72" 54" 22.00" 8.00"

SPMD – 335 35 Consult Factory

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 9: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.7

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMG, 5-15 kV. 200 Ampere Max. Single and Three Phase, 15 kV Max.

For 5 kV applications, use 15 kV table.

Utilizes General Electric JKM-95 and JVM-95 Instrument Transformers.

Units available as enclosures only (customers supplied and installed component) or as complete units from the factory.

For special configurations and sizes, consult factory.

Not available above 15 kV.

FRONT VIEW EXPOSED

BASE PLAN

SIDE VIEW EXPOSED

CIRCUIT DIAGRAM STYLE KV H W D WGT

SPMG – 315 15 48" 48" 36" 310 LB

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 10: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.8

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD, Fused, 5-35 kV. Custom Designs.

Customer specified Fused Deadfront Primary Metering Unit, 200 ampere elbow connected, 15 kV, 95 kV BIL, with S&C SML-20 fuse mountings, metering compartment, special instrument transformer mounting, and secondary wiring conduit and provisions for test blocks and meter sockets in an isolated compartment.

For other custom designs, consult factory.

FRONT VIEW

SECTION D--D

SECTION C--C

SECTION B--B SECTION A--A

SIDE VIEW

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 11: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.1.9

PADMOUNTED PRIMARY METERING GEAR (DEADFRONT)

Model SPMD, Fused, 5-35 kV. Custom Designs.

Customer specified Fused Deadfront Primary Metering Unit, 200 ampere elbow connected, 15 kV, 95 kV BIL, with S&C SML-4Z fuse mounting

For other custom designs, consult factory.

SECTION C--C

SECTION A--A SECTION B--B

FRONT & REAR VIEW SIDE VIEW

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 12: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.1

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. 200-1200 Ampere. Single and Three Phase.

Application: Powergrid Solutions (PSI) Padmount Primary Metering cabinets offer Commercial, In-dustrial, and Utility Customers a solution for revenue metering of primary voltages. Padmount primary metering cabinets are used throughout underground power systems where metering of primary voltages is necessary such as large plants, universities, and utility power supplies. Powergrid Solutions Padmount Primary Metering cabinets can be supplied fully equipped with current transformers (CT’s), potential transformers (PT’s), Meter Socket, and Test Switch completely wired and tested per the Customers’ requirements which allows for fast field installation. PSI can supply transformers to meet the customer specifications or, if it is preferred, the Customer can provide PSI with transformers to install and wire into the enclosure. PSI Padmount Primary Meter-ing gear is available to meter medium voltages ranging from 5kV to 35kV and up to 600 amps. PSI Padmount Primary Metering Cabinets are available in a variety of sizes and construction features to meet customer and environmental requirements. The PSI design fully meets and exceeds all IEEE and ANSI standards.

REAR VIEW

FRONT VIEW

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 13: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.2

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. 200-1200 Ampere. Single and Three Phase.

Catalog Number Selection Sheet. To be used in conjunction with Factory Check Sheet.

MODEL STYLE

ENCLOSURE MATERIAL

AMPERAGE

S P M L

PH

AS

E

1 2 3

05 15 25 35

VO

LTA

GE

(KV

)

2 - 200 AMP 6 - 600 AMP 12 - 1200 AMP

SPECIAL DESIGNATIONS

D - DELTA G - GROUND WYE U - UNGROUNDED WYE

EXAMPLE: SPML-325-06-U-MS-XXXX

PAD-MOUNT, LIVEFRONT PRIMARY METERING CABINET, 3 PHASE, 25 KV, 600 AMP, UNGROUNDED WYE. CABINET IS CONSTRUCTED OF MILD STEEL.

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

AL - ALUMINUM GA - GALVANNEAL MS - MILD STEEL SS - STAINLESS STEEL

Page 14: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.3

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. 200-1200 Ampere. Single and Three Phase.

Factory Check Sheet. To be used in conjunction with Catalog Number Selection Sheet.

RATINGS: Nominal System Voltage/ ______ / ______ kV

Maximum Design Voltage □ 5 kV, 60 kV BIL

Basic Insulation Level (BIL) □ 15 kV, 95 kV BIL

□ 25 kV, 125 kV BIL

□ 35 kV, 150 kV BIL

□ Other ___ kV, ___ kV BIL

Continuous Current (Line) □ ____ amp

Continuous Current (Load) □ ____ amp ENCLOSURE: Material:

□ A36 Mild Steel

□ A60 Galvanneal Steel

□ 304 L Stainless Steel

□ 5052-H32 Aluminum

Paint Finish:

□ Green. Munsell No., 7GY 3.29/1.5

□ Gray (ANSI 70). Munsell No., 8.3G 7.0/0.4

□ Gray (ANSI 61). Munsell No., 8.3G 6.10/0.54

□ Other: ___________________ 3-Point Latch Type:

□ Penta-Head Bolt

□ Hex-Head Bolt Metering Compartment Barriers:

□ 3/16”, Glass Reinforced Polyester, (standard).

□ 1/4”, Clear Polycarbonate (Lexan), Replaces 3/16” Glass Reinforced Polyester Compartment Barriers. Instrumental Transformers:

□ Current Transformers: Manufacturer: ____, Model: ____, Type: ____, kV: ____, Ratio: ____.

□ Potential Transformers: Manufacturer: ____, Model: ____, Type: ____, kV: ____, Ratio: ____.

□ Meter Socket: Manufacturer: ____, Model: ____, Type: ____.

□ Louvers for enclosure ventilation.

□ Insulation “No-Drip” Compound. Applied to the inside surface of the enclosure roof to prevent condensation.

□ Base Undercoating. Applied to the bottom 2” of the enclosure. (Not required for Stainless Steel enclosures.)

□ Specials: ____________________________________________________________________________________________

____________________________________________________________________________________________

____________________________________________________________________________________________

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 15: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.4

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. 200-1200 Ampere. Single and Three Phase.

For 5 kV applications, use 15 kV table.

Units available as enclosures only (Customer supplied and installed components) or as complete units from the factory.

For single phase units, special configurations and sizes, consult factory.

BASE PLAN

SIDE VIEW EXPOSED FRONT & REAR VIEW EXPOSED

CIRCUIT DIAGRAM STYLE KV H W D WGT

SPML – 315 15 48" 72" 54" 1100 LB

SPML – 325 25 48" 72" 54" 1100 LB

SPML – 335 35 Consult Factory

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 16: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.5

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. 200-1200 Ampere. Single and Three Phase, 15 kV, 3000 Ampere Max.

For 5 kV applications, use 15 kV table.

Utilizes low voltage current transformers, 3000 ampere max.

For special configurations and sizes, consult factory.

BASE PLAN

REAR VIEW EXPOSED

TERMINATORS

POTENTIAL TRANSFORMERS

FRONT VIEW EXPOSED SIDE VIEW EXPOSED

L.V. CURRENT TRANSFORMERS

TERMINATORS

L.V. CURRENT TRANSFORMERS

TERMINATORS

CIRCUIT DIAGRAM STYLE KV H W D WGT

SPML-315-T-LVCT 15 54" 72" 54" 1050 LB

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com

Page 17: Design • Build • Deliver - tanddproducts.com e-Catalog.pdf · Design • Build • Deliver ... Lifting lugs Loop/radial feeds Mimic bus Penta head latch ... Manufacture’s data

4.2.6

PADMOUNTED PRIMARY METERING GEAR (LIVEFRONT)

Model SPML, 5-35 kV. Custom Designs.

Customer specific Livefront Primary Metering Unit, 600 ampere with specials terminations, 15 kV, 95 kV BIL.

For custom designs, consult factory.

FRONT & REAR VIEW RIGHT SIDE VIEW

SECTION A--A

SECTION C--C

SECTION B--B

© 2015 Powergrid Solutions Inc. Catalog Version 2.1.1

To find a listing for your local Powergrid Solutions representative, log on to www.powergridsolutionsinc.com