Density and Concentration Measurement
DT Series Magd Nasr Ph.Dr.Eng.
-
8/9/2019 Density and Concentration Measurement
2/33
Basic Concepts
Introduction to the DT series Transmitter
Oil & Gas Applications
DT Series
-
8/9/2019 Density and Concentration Measurement
3/33
-
8/9/2019 Density and Concentration Measurement
4/33
Interface Level = 0 to 100%
100 %
0 %
Oil
Water
Interface Level Measurement MethodInterface Level Measurement Method
The interface level isproportional to the output
signal.
-
8/9/2019 Density and Concentration Measurement
5/33
Introduction
DT Series
-
8/9/2019 Density and Concentration Measurement
6/33
PRESSURE
SENSORSPRESSURE
SENSORS
TEMPERATURE
SENSOR
PROCESSCONECTION
FLANGE
ANSI B16.5
PROCESS
CONECTION
FLANGE
ANSI B16.5
CAPACITIVE CELL
ELECTRONICS
&
LOCAL LCD
DT SeriesDT Series -- ConfigurationConfiguration
Side
Mounting
Top
Mounting
-
8/9/2019 Density and Concentration Measurement
7/33
Density:
SI system unit: kg/m3
Commonly used units: g/cm3 or g/l
English system unit: lbm/ft3
A.P.I. Concentration:
Degrees: Baum, Gay-Lussac, INPM
% of Solids
Measurement UnitsMeasurement Units
-
8/9/2019 Density and Concentration Measurement
8/33
Designed for Density, Concentration & Interface level ON LINE
measurements Two-wire loop powered equipment, 12 to 45 Vdc
Communication:
4-20mA + Hart (DT301),
Foundation Fieldbus (DT302)
Profibus (DT303)
Remote monitoring and calibration using Palm Handheld and /or PC
Single integrated unit, no moving parts Local digital indicator
Direct readout in several engineering units
Process temperature indication,
Temperature variable output available only in bus version
Suitable for dynamic and static liquids
Explosion-proof and intrinsically safe
CharacteristicsCharacteristics
-
8/9/2019 Density and Concentration Measurement
9/33
Working Ranges
Ranges
Range 1 : 0.5 to 1.8 g/cm3
Range 2 : 1.0 to 2.5 g/cm3
Range 3 : 2.0 to 5.0 g/cm3
Minimum Span
Range 1 : 0.025 g/cm3
Range 2 : 0.050 g/cm3
Range 3 : 0.250 g/cm3
Accuracy
Range 1: 0.0004 g/cc
Range 2: 0.0007 g/cc Range 3: 0.0016 g/cc
-
8/9/2019 Density and Concentration Measurement
10/33
Temperature Limits
Ambient: -40 to 85 C
Process: -20 to 150 C
Static Pressure Limit:
70 Bar (1,015 psi)
Viscosity:
No known limits, already used in
liquids with 10,000 Cp
Working ConditionsWorking Conditions
-
8/9/2019 Density and Concentration Measurement
11/33
Materials
Probe
Stainless Steel 316L SST
Hastelloy C276
Diaphragm
Stainless Steel 316L SST
Hastelloy C276
Housing Aluminum Alloy
Stainless Steel 316L SST
Measurement Tank Stainless Steel 316L SST
-
8/9/2019 Density and Concentration Measurement
12/33
Process Connection
Process Connection
Flange size: 4 RF
Pressure rating: Ansi 150, 300, 600
-
8/9/2019 Density and Concentration Measurement
13/33
DT Series Features
Easy Installation
Low Maintenance
High Accuracy
No special training
Easy setup and calibration
-
8/9/2019 Density and Concentration Measurement
14/33
Typical Installation
DT Series
-
8/9/2019 Density and Concentration Measurement
15/33
Online Installation, PipelinesOnline Installation, Pipelines
-
8/9/2019 Density and Concentration Measurement
16/33
Tank InstallationTank Installation
-
8/9/2019 Density and Concentration Measurement
17/33
Separator tank InstallationSeparator tank Installation
-
8/9/2019 Density and Concentration Measurement
18/33
Applications
Exploration
Oil & Gas Production
DT Series
-
8/9/2019 Density and Concentration Measurement
19/33
Exploration Application
Drilling Mud Density
Brine Density Ballast Density
Fluid Interface
-
8/9/2019 Density and Concentration Measurement
20/33
Oil & Gas Production Applications
Online Measurement
Tank Level Interface Measurement Online Blending
-
8/9/2019 Density and Concentration Measurement
21/33
Application:
Crude oil densitymeasurement, direct in line at
90 m3/h
Online Density MeasurementOnline Density Measurement
-
8/9/2019 Density and Concentration Measurement
22/33
Application:
Vertical Separator tank
Interface Level MeasurementInterface Level Measurement
-
8/9/2019 Density and Concentration Measurement
23/33
Customer: Petrobras
Location: So Miguel dosCampos, Alagoas State,
Brazil.
Application:
Interface Level Oil / Salt
Water
Interface Level MeasurementInterface Level Measurement
-
8/9/2019 Density and Concentration Measurement
24/33
Reference Letter:
Interface Level of Oil/ Salt Water
PetrobrsPetrobrs Reference LetterReference Letter
-
8/9/2019 Density and Concentration Measurement
25/33
Customer: PetrobrasLocation: Merluza Platform,
Santos Basin, Brazil
Application:
Density of condensed gas
DT SeriesDT Series Offshore ApplicationOffshore Application
-
8/9/2019 Density and Concentration Measurement
26/33
Customer: PetrobrasLocation: Marlim Sul Field,
Campos Basin, Brazil
Application:
Interface Level Oil / Water
DT SeriesDT Series Offshore ApplicationOffshore Application
-
8/9/2019 Density and Concentration Measurement
27/33
Application:
Horizontal Crude Oil Separator tank
Interface Level MeasurementInterface Level Measurement
-
8/9/2019 Density and Concentration Measurement
28/33
Application:
Project Oil Separator tank and
Water Cut
Water Cut MeasurementWater Cut Measurement
-
8/9/2019 Density and Concentration Measurement
29/33
Application:
Oil-Emulsion-Water tank separator
Online Separation MeasurementOnline Separation Measurement
-
8/9/2019 Density and Concentration Measurement
30/33
Application:
Liquid Custody Transfer Measurement Skids
Custody TransferCustody Transfer
-
8/9/2019 Density and Concentration Measurement
31/33
Application:
Fieldbus Blending Solution
Online BlendingOnline Blending
-
8/9/2019 Density and Concentration Measurement
32/33
Application:
Fieldbus Blending Solution
Online Concentration MeasurementOnline Concentration Measurement
-
8/9/2019 Density and Concentration Measurement
33/33
END