DEMA TITAN WAREWASH T-812 &T-813

64

description

DEMA TITAN WAREWASH T-812 &T-813. Instructional Presentation. The Titan  ware wash system controls all chemical delivery functions for dish machines and similar warewash applications. The system has an advanced power supply that will accept 100V–250V 50/60Hz. - PowerPoint PPT Presentation

Transcript of DEMA TITAN WAREWASH T-812 &T-813

Page 1: DEMA TITAN WAREWASH T-812 &T-813
Page 2: DEMA TITAN WAREWASH T-812 &T-813

The The TitanTitan ware wash system controls all chemical delivery functions ware wash system controls all chemical delivery functions for dish machines and similar warewash applications.for dish machines and similar warewash applications. The system has The system has an advanced power supply that will accept 100V–250V 50/60Hz. an advanced power supply that will accept 100V–250V 50/60Hz. The TitanThe Titan responds to detergent and rinse triggers in the range of responds to detergent and rinse triggers in the range of 20V–500V 50/60Hz. The 20V–500V 50/60Hz. The TitanTitan has been designed for simple has been designed for simple installation, set up, and operation.installation, set up, and operation.

The Titan has an Auto Switchover feature that allows automatic switchingThe Titan has an Auto Switchover feature that allows automatic switching from Concentration to Probeless in the case of a probe fault, from Concentration to Probeless in the case of a probe fault,

(and back again if the fault clears). This feature allows continued operation (and back again if the fault clears). This feature allows continued operation or the dish machine while cutting down on unnecessary service calls. or the dish machine while cutting down on unnecessary service calls.

Conditions that can activate this feature are the followingConditions that can activate this feature are the following::

Open probe – a probe wire is disconnected or there is lime buildup on the Open probe – a probe wire is disconnected or there is lime buildup on the tips.tips.

Closed probe – a piece of flatware may be lying across the probe tips.Closed probe – a piece of flatware may be lying across the probe tips.

Detergent not feeding properly – too much or too little detergent.Detergent not feeding properly – too much or too little detergent.

Page 3: DEMA TITAN WAREWASH T-812 &T-813

Click on the chapter you wish to view

Page 4: DEMA TITAN WAREWASH T-812 &T-813

• Wall Mounting• Electrical Connection• Tubing• Conductive Probe

Page 5: DEMA TITAN WAREWASH T-812 &T-813

• Unpack the Titan• Remove mounting plate from

Titan (Remove screw and slide plate down)

• Attach mounting plate to wall• Replace Titan on the mounting

plate (Replace screw)

Page 6: DEMA TITAN WAREWASH T-812 &T-813
Page 7: DEMA TITAN WAREWASH T-812 &T-813

Remove screw and slide Mounting Plate off(downward direction)

Page 8: DEMA TITAN WAREWASH T-812 &T-813

• Desired location of Titan and chemicals

• Electrical Connection for Titan

• Flat vertical surface away from splashing and steam originating from machine

• Titan should must be placed so that it can be easily observed and serviced

Page 9: DEMA TITAN WAREWASH T-812 &T-813
Page 10: DEMA TITAN WAREWASH T-812 &T-813

Follow instructions on Mounting Bracket

Page 11: DEMA TITAN WAREWASH T-812 &T-813

• Connect power to the Titan per dish machines manufacture's recommendations. Constant power should be supplied to the Titan anytime the dish machine power is on. The Titan can also be plugged directly into a wall socket.

• Connect the Detergent Trigger to the machine.( If the Machine does not have a specific trigger connection, then the trigger should be wired to the coil of the Motor Contactor)

• Connect the Rinse Trigger to the Machine. (If the Machine does not have a specific rinse trigger connection, then the trigger should be wired to the Rinse Solenoid Valve)

Page 12: DEMA TITAN WAREWASH T-812 &T-813

• Tubing connection from the Titan to the Machine.

• Tubing connection from the Titan to the Chemical.

Page 13: DEMA TITAN WAREWASH T-812 &T-813

Attaching the Bulkhead Fitting for the chemical injection of a liquid detergent.

OutsideInside

•Chemical injection fitting must be above the water level in the tank

•Chemical Injection fitting should be directly above Conductive Probe

Page 14: DEMA TITAN WAREWASH T-812 &T-813

Installing Conductive Probe

Inside Outside

•The Probe should be installed 2/3 down from water level of the tank

•The probe should be installed directly below chemical injection

Page 15: DEMA TITAN WAREWASH T-812 &T-813
Page 16: DEMA TITAN WAREWASH T-812 &T-813
Page 17: DEMA TITAN WAREWASH T-812 &T-813

Changing Languages

•Press to get to language screen

•Press to start edit screen

•Press or to change languages

•Press to accept change

Page 18: DEMA TITAN WAREWASH T-812 &T-813

Detergent Prime

• Press to scroll to Detergent Prime

• Press to start priming

• Press again to stop priming

Pump will run for 2 minutes if it is not stopped manually

Page 19: DEMA TITAN WAREWASH T-812 &T-813

Rinse Prime

• Press to scroll to Rinse Prime

• Press to start priming

• Press again to stop priming

Pump will run for 2 minutes if it is not stopped manually

Page 20: DEMA TITAN WAREWASH T-812 &T-813

Sanitizer Prime

• Press to scroll to Sanitizer Prime

• Press to start priming

• Press again to stop priming

Pump will run for 2 minutes if it is not stopped manually

Page 21: DEMA TITAN WAREWASH T-812 &T-813

Detergent Status Display

Press to display Status

C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor

P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading

T – Recharge

+ Titan is feeding detergent

- Titan is not feeding detergent

* Screen will stay active for 30 minutes until the up or down arrow is pressed or 30 minutes lapse

Page 22: DEMA TITAN WAREWASH T-812 &T-813

Rack Count

Rack Count 00000

This is a read only record 0-49999

Page 23: DEMA TITAN WAREWASH T-812 &T-813

Descale

Press to start

Press again to stop

Page 24: DEMA TITAN WAREWASH T-812 &T-813
Page 25: DEMA TITAN WAREWASH T-812 &T-813

System Access is only available after Initial Programming is completed

Page 26: DEMA TITAN WAREWASH T-812 &T-813

Enter Code

Page 27: DEMA TITAN WAREWASH T-812 &T-813
Page 28: DEMA TITAN WAREWASH T-812 &T-813
Page 29: DEMA TITAN WAREWASH T-812 &T-813
Page 30: DEMA TITAN WAREWASH T-812 &T-813
Page 31: DEMA TITAN WAREWASH T-812 &T-813
Page 32: DEMA TITAN WAREWASH T-812 &T-813
Page 33: DEMA TITAN WAREWASH T-812 &T-813
Page 34: DEMA TITAN WAREWASH T-812 &T-813
Page 35: DEMA TITAN WAREWASH T-812 &T-813
Page 36: DEMA TITAN WAREWASH T-812 &T-813
Page 37: DEMA TITAN WAREWASH T-812 &T-813
Page 38: DEMA TITAN WAREWASH T-812 &T-813
Page 39: DEMA TITAN WAREWASH T-812 &T-813
Page 40: DEMA TITAN WAREWASH T-812 &T-813
Page 41: DEMA TITAN WAREWASH T-812 &T-813
Page 42: DEMA TITAN WAREWASH T-812 &T-813
Page 43: DEMA TITAN WAREWASH T-812 &T-813
Page 44: DEMA TITAN WAREWASH T-812 &T-813
Page 45: DEMA TITAN WAREWASH T-812 &T-813

Detergent

Level

Rinse

Level

Sanitizer

Level

Page 46: DEMA TITAN WAREWASH T-812 &T-813

C - Concentration I – Initial Set Point in Concentration Mode Detergent Sensor

P – Probeless D – Dwell Alarm Point in Probeless mode Probe Reading

T – Recharge

+ Concentration mode

- not Concentration mode

* - When a trigger is present

Page 47: DEMA TITAN WAREWASH T-812 &T-813

L – Liquid

D - Dry

D – Delay

R – Rinsing

L – Limit

Reached

Rinse Alarm

Set Point

Rinse Sensor

Reading

Page 48: DEMA TITAN WAREWASH T-812 &T-813

Liquid Sanitizer alarm set Point

+ - running

- - not running

Sensor

Reading

Page 49: DEMA TITAN WAREWASH T-812 &T-813

Displays total switchover count for OVER and Under feeding

Displays total switchover counts for

An open probe or shorted probe

Page 50: DEMA TITAN WAREWASH T-812 &T-813
Page 51: DEMA TITAN WAREWASH T-812 &T-813

The DEMA Magnetic Field Reader eliminates the need to make wire connections to warewash and laundry machines. The DEMA Magnetic Reader detects the presence of the magnetic field surrounding an AC solenoid valve or Ac motor. This may then be used as a trigger signal to a DEMA warewash or laundry dispenser.

The DEMA Inductive Warewash Probe replaces the conductivity probe used to sense detergent concentration in the wash tank. The advanced technology of the DEMA Inductive Warewash Probe allows the wash tank conductivity to be sensed without any metal contacting the wash tank solution. As a result, the DEMA Inductive Warewash Probe is immune to contaminants, such as lime, which plate onto conductivity probes.

Page 52: DEMA TITAN WAREWASH T-812 &T-813

• Disconnect the power from the Titan and the warewash machine.

• Disconnect rinse or wash trigger cable (81-153-1) from the Titan control board (81-118-20).

• Route the Magnetic Field Reader cable as shown on next page in to the Titan enclosure.

• Plug the Magnetic Field Reader cable into rinse or wash trigger connector on the Titan control board (81-118-20).

• With the door on the Titan fully open; secure the Magnetic Field Reader cable in the bottom plate of the Titan with strain relief (81-183-1).

• Close the door on the Titan.

• Place the Magnetic Field Reader against the coil of the solenoid valve or motor housing to be used for sensing. The sensing element is on the bottom side of the Magnetic Field Reader below the point of the arrow that is on the top.

• Secure the Magnetic Field Reader in place with the Hook & Loop strap. The strap may be trimmed as required.

• Turn the power on the Titan.

• Turn on the power to the warewash machine.

• Energize the solenoid valve or motor to which the Magnetic Field Reader is attached.

• After one second a green LED on the Magnetic Field Reader should illuminate next to the cable. If it does not illuminate, reposition the sensor until it does.

Page 53: DEMA TITAN WAREWASH T-812 &T-813

• De-energize the solenoid valve or motor. The green LED should turn off after one second. If it stays on, reposition the sensor.

• When properly installed the green LED will turn on one second after the solenoid valve or motor which it is attached is activated. It will turn off one second after deactivation.

Page 54: DEMA TITAN WAREWASH T-812 &T-813

• Disconnect the power from the Titan and the warewash machine.

• Drain the warewash machine

• Disconnect the probe wire from the Titan control board and remove the conductivity probe from the tank.

• Install the DEMA Inductive Warewash Probe in the wash tank, through the wall shown on next page. The hole through the center of the DEMA Inductive Warewash Probe must be vertical.

• Route the DEMA Inductive Warewash Probe cable, as shown on the next page, into the Titan enclosure. The connector and strain relief fit the ¾” hole in the bottom-center access panel of the Titan enclosure.

• Plug the DEMA Inductive Warewash Probe cable into the white eight pin connector on the Titan control board (81-118-20). The connector is directly above the microcontroller chip.

• With the door on the Titan fully open; secure the DEMA Inductive Warewash Probe cable in the bottom plate of the Titan with strain relief (81-183-2 or-3).

• Close the door on the Titan.

• Turn on the power to the Titan

• Turn on the power to the warewash machine.

Page 55: DEMA TITAN WAREWASH T-812 &T-813

NO. PART NUMBER DESCRIPTION

1 81-183-2 (Use either -2 or -3)81-183-3

Cable Strain Relief 5/8” Cable Strain Relief 3/4"

2 82-28-1 Inductive Probe Kit

Page 56: DEMA TITAN WAREWASH T-812 &T-813
Page 57: DEMA TITAN WAREWASH T-812 &T-813
Page 58: DEMA TITAN WAREWASH T-812 &T-813
Page 59: DEMA TITAN WAREWASH T-812 &T-813
Page 60: DEMA TITAN WAREWASH T-812 &T-813
Page 61: DEMA TITAN WAREWASH T-812 &T-813
Page 62: DEMA TITAN WAREWASH T-812 &T-813
Page 63: DEMA TITAN WAREWASH T-812 &T-813
Page 64: DEMA TITAN WAREWASH T-812 &T-813