10/7/13 Dell - Dell| EMC CX4 Series Storage Arrays - Management Module https://dtt.dell.com/ifr/EMC/CX4_Series_Arrays/CX4-240_man_mod.asp 1/3 Dell Training Tool | Dell|EMC CX4 Series Storage Arrays Previous | Next Management Module Each CX4 storage array has two management modules, one for SPA and one for SPB. Each module has SPS, management LAN and peer service LAN connectors. The pictures below shows the management module for the CX4 storage arrays that use the 2U enclosure chassis (the CX4-120, CX4-240 and CX4-480 arrays): Fig: Management Module for CX4-120, CX4-240 and CX4-480 Storage Arrays The management module for SPA is situated on the right hand side of the chassis, when viewed from the rear. The management module for SPB is on the left hand side. Fig: Management Module positions Management Module Features The management module has the following ports & connectors:

description

training notes

Transcript of Dell - Dell_EMC CX4 -240Series Storage Arrays - Management Module

  • 10/7/13 Dell - Dell|EMC CX4 Series Storage Arrays - Management Module

    https://dtt.dell.com/ifr/EMC/CX4_Series_Arrays/CX4-240_man_mod.asp 1/3

    Dell Training Tool | Dell|EMC CX4 Series StorageArrays

    Previous | Next

    Management Module

    Each CX4 storage array has two management modules, one for SPA and one for SPB. Each module has SPS,management LAN and peer service LAN connectors.

    The pictures below shows the management module for the CX4 storage arrays that use the 2U enclosure chassis (theCX4-120, CX4-240 and CX4-480 arrays):

    Fig: Management Module for CX4-120, CX4-240 and CX4-480 Storage Arrays

    The management module for SPA is situated on the right hand side of the chassis, when viewed from the rear. Themanagement module for SPB is on the left hand side.

    Fig: Management Module positions

    Management Module FeaturesThe management module has the following ports & connectors:

  • 10/7/13 Dell - Dell|EMC CX4 Series Storage Arrays - Management Module

    https://dtt.dell.com/ifr/EMC/CX4_Series_Arrays/CX4-240_man_mod.asp 2/3

    Fig: Management Module Ports & Connectors

    Management Module Features

    Feature Connector Type Usage

    Management LAN Port RJ45 1Gb Ethernet SP management

    Peer Service 1GB Ethernet LANport

    RJ45 1Gb Ethernet Service port management of peer SP

    Management Serial Port for SP Micro DB9RS-232 connection to a service console via null modemserial cable

    Standby Power Supply (SPS)Serial Port

    Micro DB9 Communication between SPS and SP

    NMI buttonFor engineering useonly

    Forced reboot and crash dump

    SP Mangement Ports and IPv6SP management ports can now be configured with a choice of either IPv4 (the default option) or IPv6 (which must beselected manually). The management port Supports IPv6 for in-bound traffic. Out-bound IPv6 support is forPing/Traceroute only. There is no IPv6 tunneling support.

    Peer Service LAN PortWhen connecting to an SP using the peer service LAN port, you must be connected to the management module thatcontrols the opposite (partner or peer) SP. Hence, if you wish to connect to SPA, you must physically connect to the peerservice LAN port on the managment module for SPB. A standard Ethernet cable is used to connect to the peer serviceLAN port (cross-over cables are not require). You must use the IP address for the peer SP. The peer service LAN portprovides full GUI and CLI access to the storage array and can manage both SPs.

    The IP address settings for the peer service LAN ports are as follows:

  • 10/7/13 Dell - Dell|EMC CX4 Series Storage Arrays - Management Module

    https://dtt.dell.com/ifr/EMC/CX4_Series_Arrays/CX4-240_man_mod.asp 3/3

    Peer Service LAN port Settings

    SP IP Address Subnet Mask

    SPA 128.221.1.250 255.255.255.248

    SPB 128.221.1.251 255.255.255.248

    NOTE: Domain security applies when accessing a storage array through a Service LAN port. Log on credential for thearray are required.

    Status LEDsThe tables below gives details of the rear LEDs for the CX4 SPE 2U chassis:

    Management Module LED Information

    LED LED condition Condition/status

    Management module status LED is on module handle

    Solid green Management module has power

    Off Power is Not being supplied to module

    Amber Module is faulted

    Management/peer service LAN link LEDSolid green Good Ethernet link

    off No link (bad cable or connector, configuration mismatch)

    Management/peer service LAN activity LED

    Blinking amber Brief bursts of data detected on port

    Solid amber Streams of data detected on port

    Off No data detected on port