Default
Transcript of Default
Parameter name vallue Inter-frequency Measure Report Mode Periodical reporting Inter-frequency Measure Filter Coeff D3Inter-frequency Measure Periodical Measurement Report Period D500 2B Hysteresis <NULL>
2D Hysteresis 4 2F Hysteresis 4
HHO Hysteresis 0 Weight for Used frequency 0 Event 2B Trigger Delay <NULL> Event 2D Trigger Delay D320
Event 2F Trigger Delay D1280 HHO Period Trigger Delay 0 Inter-freq CS Measure Start Ec/No THD -18 Inter-freq CS Measure Stop Ec/No THD -16 Inter-freq R99 PS Measure Start Ec/No THD -18
Inter-freq H Measure Start Ec/No THD -18 Inter-freq R99 PS Measure Stop Ec/No THD -16 Inter-freq H Measure Stop Ec/No THD -16 Inter-freq CS Measure Start RSCP THD -115 Inter-freq CS Measure Stop RSCP THD -113 Inter-freq R99 PS Measure Start RSCP THD -115 Inter-freq H Measure Start RSCP THD -115 Inter-freq R99 PS Measure Stop RSCP THD -113 Inter-freq H Measure Stop RSCP THD -113 Inter-freq CS Target Frequency Trigger Ec/No THD -16 Inter-freq R99 PS Target Frequency Trigger Ec/No THD -16
Inter-freq HSPA Target Frequency Trigger Ec/No THD -16 Inter-freq CS Target Freqency Trigger RSCP THD -113 Inter-freq R99 PS Target Frequency Trigger RSCP THD -113 Inter-freq HSPA Target Freqency Trigger RSCP THD -113 Inter-freq CS Used frequency trigger Ec/No THD -16 Inter-freq R99 PS Used frequency trigger Ec/No THD -16 Inter-freq H Used frequency trigger Ec/No THD -16 Inter-freq CS Used frequency trigger RSCP THD -113 Inter-freq R99 PS Used frequency trigger RSCP THD -113 Inter-freq H Used frequency trigger RSCP THD -113 Inter-freq Measure Timer Length 60
2B Event Retry Period <NULL> 2B Event Retry Max Times <NULL> Inter-freq Coverage Handover Trigger Delay 0
Parameter valueIntra-frequency L3 Filter Coefficient D3
Intra-frequency Measurement Quantity CPICH_EC/NO
Event 1A to Periodical Report Number D16
Event 1A to Periodical Report Period D4000
Event 1C to Periodical Report Number D16
Event 1C to Periodical Report Period D4000
Event 1J to Periodical Report Number D64
Event 1J to Periodical Report Period D1000
VP Service Event 1A Relative Threshold 6
CS Non-VP Service Event 1A Relative THD 6
PS Service Event 1A Relative Threshold 6
VP Service Event 1B Relative Threshold 10
CS Non-VP Service Event 1B Relative Threshold 10
PS Service Event 1B Relative Threshold 10
Event 1F Absolute Ec/No Threshold -24
Event 1F Absolute RSCP Threshold <NULL>
1A Hysteresis 0
1B Hysteresis 0
1C Hysteresis 8
1D Hysteresis 8
1F Hysteresis 8
1J Hysteresis 8
Weighted factor 0
Event 1A Triggering Delay D320
Event 1B Triggering Delay D640
Event 1C Triggering Delay D640
Event 1D Triggering Delay D640
Event 1F Triggering Delay D640
Event 1J Triggering Delay D640
Max Evaluation Period of SHO Failure 60
Threshold Number of SHO Failure 3
Relative Threshold of SHO Failure 2
Period of Penalty Timer for SHO Failure After Down Rate 30
Min Quality THD for SHO -24
Max Number of Cell in Active Set 3
Event 1F Blind Handover Trigger Condition -115
Intra-Frequency Measurement Report Interval of Blind HO D250
Intra-Frequency Masurement Report Amount of Blind Handover D2
Parameter Value Inter-RAT Report Mode Periodical reporting
2D/2F Filter Coefficient D3
3A Measure Quantity <NULL>
Inter-RAT Filter Coefficient D3
Weight for Used Frequency 0
Inter-RAT Period Reporting Interval D1000
2D Hysteresis 4
2F Hysteresis 4
3A Hysteresis <NULL>
Inter-RAT Hysteresis 0
2D Event Trigger Delay Time D320
2F Event Trigger Delay Time D1280
3A Event Trigger Delay Time <NULL>
Time to Trigger Handover to Non-Verified GSM Cell 0
Time to Trigger Handover to Verified GSM Cell 0
BSIC Verify Switch Verify mode
Inter-RAT CS Measure Start Ec/No THD -14
Inter-RAT CS Measure Stop Ec/No THD -11
Inter-RAT R99 PS Measure Start Ec/No THD -15
Inter-RAT HSPA Measure Start Ec/No THD -15
Inter-RAT R99 PS Measure Stop Ec/No THD -12
Inter-RAT HSPA Measure Stop Ec/No THD -12
Inter-RAT CS Measure Start RSCP THD -102
Inter-RAT CS Measure Stop RSCP THD -98
Inter-RAT R99 PS Measure Start RSCP THD -110
Inter-RAT HSPA Measure Start RSCP THD -110
Inter-RAT R99 PS Measure Stop RSCP THD -105
Inter-RAT HSPA Measure Stop RSCP THD -105
Inter-RAT CS Handover Decision THD 21
Inter-RAT R99 PS Handover Decision THD 16
Inter-RAT HSPA Handover Decision THD 16
Inter-RAT CS Used Frequency Trigger Ec/No THD <NULL>
Inter-RAT R99 PS Used Frequency Trigger Ec/No THD <NULL>
Inter-RAT HSPA Used Frequency Trigger Ec/No THD <NULL>
Inter-RAT CS Used Frequency Trigger RSCP THD <NULL>
Inter-RAT R99 PS Used Frequency Trigger RSCP THD <NULL>
Inter-RAT HSPA Used Frequency Trigger RSCP THD <NULL>
Inter-RAT Measure Timer Length 60
Inter-RAT Ping-Pong Timer 0
Inter-RAT Ping-Pong Hysteresis 0
3A Event Retry Period <NULL>
3A Event Maximum Retry Times <NULL>
Inter-RAT HO Physical Channel Failure THD 3
Inter-RAT HO Physical Channel Failure Penalty Timer 30
(Number of results = 1)
Inter-RAT Filter Coefficient = D3 3C Hysteresis = 0 Event 3C Trigger Delay = D640 BSIC Verify Switch = Verify mode Inter-RAT CS Handover Decision THD = 21 Inter-RAT PS Handover Decision THD = 21 Inter-RAT Handover Max Attempt Times = 16 Inter-RAT Measure Timer Length = 60 Send Load Info to GSM Ind = OFF NCOV Reloc Ind Based on GSM Cell Load = ON CS Domain Reloc GSM Load THD = 80 PS Domain Reloc GSM Load THD = 60 Event 3C Retry Period = 4 Event 3C Retry Max Times = 1 Inter-RAT HO Physical Channel Failure THD = 3Inter-RAT HO Physical Channel Failure Penalty Timer = 30
(Number of results = 1)
Softer Handover Combination Indication Switch = NodeB chooses whether combine at NodeB HSPA Hysteresis Timer Length = 0Inter-Freq and Inter-RAT Coexist Measure Threshold Choice = Choosing the inter-RAT oriented parameters Max Number of Cell in EDCH Active Set = 3The Timer Length of Anti Pingpong NCOV Interfreq Handover = 30
(Number of results = 1)
CQI Power Offset = PO_24/15 CQI Power Offset Multi-RLS = PO_24/15 CQI Repetition Factor = 1 CQI Repetition Factor Multi-RLS = 1 CQI Feedback Cycle k = D2 CQI Feedback Cycle k Multi-RLS = D2 Conv Services CQI Feedback Cycle K = D2 MIMO Services CQI Feedback Cycle k = D2DC MIMO Services CQI Feedback Cycle k = D4
(Number of results = 1)
Inter-frequency Measure Filter Coeff = D3 2C Hysteresis = 6 Event 2C Trigger Delay = D640Inter-freq measure target frequency trigger Ec/No THD = -16 Inter-freq Measure Timer Length = 60 2C Event Retry Period = 4 Event 2C Retry Max Times = 1