Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as...

21
Dedicated Dynamic Driven

Transcript of Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as...

Page 1: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

DedicatedDynamicDriven

Page 2: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Supplier of integrated offshore packagesEquipment, parts and service

Offshore System Packages

Page 3: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

3 facilities12 companies9200 square meter offices4200 square meter workshops

MAKING ROOM FOR GROWTH

Page 4: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Oil & Gas SolutionsMods & UpgradesEngineeringStudies & SurveysOperational Support

One Stop Shop

Page 5: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

ROXEL GROUP

ROXEL ELEKTRO

ROXEL BUILDING TECHNOLOGY

ROXEL KLIMA

ROXEL VVS

ROXEL AS

ROXEL GROUP

ROXEL ENERGYROXEL TEKNISKE

ROXEL PRODUCTS

ROXEL AANESTAD

ROXEL SOLUTIONS

ROXEL HVAC

ROXEL RENTAL

ROXEL PROMECH

12 companies146 employees300 MNOK Turnover600 MNOK Backlog

ROXEL INFRASTRUCTURE

ROXEL INFRA

Page 6: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Modifications/Upgrades Process/Utility/Drilling/Well/Safety Rental/Units/Machines

El/VVS/Vent/Automation Airports/Luggage handling Factories/Industry/Machines

OFFSHORE

INDUSTRY

Business areas

Page 7: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Forus

Integrated drilling packagesModifications and supportEPCIC

Dri l l ing SystemsIndependent system integration of 3’rd party suppliers:

• Drillers cabins• Pipehandling control cabins• Mud & cement control systems• Local Equipment Room (LER)• Control cabinets (PLC & HMI)• Instrumentation• EX equipment• Drives • Robotics and automation

Page 8: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

New PSD system presentationChallenges:

High risk potentialHarsh environment Critical processPortable equipment

SAFETY SYSTEMS - Offshore

Page 9: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Forus

Process ShutdownTailormade Systems forEx Zones & IEC61508/11 - SIL

Safety Systems

Page 10: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Forus

Drive CabinetBrake Resistor &Operator Station

Control & Drive Skid

Page 11: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Forus

Derrick & Pipehandling equipmentMud & Solids SystemsSeismic Logistic Solutions

Dri l l ing Equipment & Chemicals

Page 12: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Forus

Ex zone 1 for control and instrumentsSIL2 according to IEC61508/511/OLF070DNV approved acc to DNV-OS-D202

PortablePSD for Well Test

Page 13: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Roxel is approved as Solution Integrator by Siemens:

International program:1300 partners world wide7 partners in Norway

Roxel is approved for the following areas:

Process Control System SIMATIC PCS7, specializing on PCS 7 Safety Human Machine Interface SIMATIC HMI Automation System SIMATIC

Roxel is approved as Safety Specialists in PCS 7:

First partner in Norway Only partner within O&G in Scandinavia 18 partners outside Germany

Page 14: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

How the program works:

Support network- Siemens IADT in Oslo- Product experts in Germany- Safety Centre in K’he

Competence through mandatory training- SIL courses in Germany (3 x 2 weeks)- Annual Certification- PCS 7 Work shops- Partner Summits- Information on new products

Page 15: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

SIL – Competence and skills

Rules and regulations:- IEC 61508/511/OLF070- API RP 14C / ISO10418 - DNV-OS-A101 – Safety Principles and

Arrangements

Documentation and formalities:- SRS and SAR- SIF calculations and Test intervals- FMEA and HAZOP- Follow-up certifying bodies- Follow-up vendors and subvendors

Equipment and solutions:- Siemens PCS 7 / F-tools- Safety Matrix - Siemens Simatic S7300F/400HF Redundancy- Field instrumentation and actuators

Project Management:- Quality Assurance- Project documentation- Procedures and Reports, SA&VP - Certificates

Life Cycle:- Modification and service- Testing to maintain and document SIL-level

Page 16: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

SIL – Solutions and tools

SIEMENS SIMATIC PCS 7

- Based on Standard F-tools library- Full PCS 7 HMI interface

SIEMENS SIMATIC Safety Matrix tool:

- Configuration of logic according to Safe Charts / C&E- Safety Matrix Editor- Safety Matrix Viewer, integrated in PCS 7 HMI

Page 17: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Safety Matrix - Benefits

The Safety Matrix solution has the following benefits:

1. Less programming skills for modifications.2. Software is configured and generated.3. Automatic generation of SIL documentation 4. Real-time overview of the C&E 5. Diagnostics functions for maintenance and operation6. Integrated commands are included: Bypass, Reset,

Override, Parameter modification7. Sequence of event display and savings is provided8. Automatic version tracking9. Automatic documentation of modifications

Page 18: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Roxel can provide:

- Certified knowledge of Siemens PCS 7- Certified competence in Safety Systems- Skilled personnel with long and relevant experience- Drilling competence – Hitec, NOV, MHWirth- Modular systems, DNV certified, Z-015- Ex competence

Page 19: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Portable PSD & Datalogging system

Page 20: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Requirements

NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010, D001) DNV-OS-D202, R0 – Continuous available ISO9001

Page 21: Dedicated Dynamic Driven€¦ · NORSOK D-007 "Well Testing Systems" specifies IEC61508/11, SIL2 as of OLF070. Other NORSOK standards will follow (D-002 Well Intervention, D-010,

Simatic Process Device Manager HART Instrument Validation

HART Interface