Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator...

16
Radiators heatingthrough innovation. MYSON Decor VN Radiator Series Installation & Technical Guide

Transcript of Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator...

Page 1: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

Radiators

heatingthroughinnovation.

MYSONDecor VN Radiator Series Installation & Technical Guide

Page 2: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

02

DECOR.DECOR radiators stand for aesthetically sophisticated Design, combined with

technologically perfect heating. They were conceived with all areas of installation and use in

mind.

Radiators

03040506070809

10 - 12

Ko

nte

c B

asi

cs

Myson, Inc. Limited Warranty

Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.

The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.

NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE

The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.

Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions.

STEEL PANEL RADIATORS -- SELECT, T6, DÉCOR, COLUMN AND BENCH

The duration of warranty for steel panel radiators is 5 Years.

• Painted finishes will not peel or flake from the surface of the radiator• The body of the radiator and its welded joints will not leak when the product is properly installed and maintained

according to Myson's instructions.

What is not covered:

• Rust occurring from improperly sealed threaded connections or oxygen corrosion

• Electrolytic corrosion caused by failure to flush the system properly after initial installation

Contents

What is covered:

Important information Product description Model overview / connection dimensions Piping & rough-inWelded bracket positions Mounting and wall-clearance Decor 2H baseboard mounting detail / Start-up & MaintenanceHeating outputs / weights / water contentPiping arrangementsValve selection

1314

Page 3: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

Important Information 03

BEFORE YOU BEGIN

SAFETY PRECAUTIONSRadiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of aradiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and usersshould ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installersand users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should begiven to installing low surface temperature radiators, or to placing guards in front of the radiators.

For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a waythat it is suitable for intended use AND predictable misuse. A number of elements need to be taken intoconsideration including the fixing method used to secure the radiator to the wall, the type and condition of the wallitself, and any additional potential forces or weights that may happen to be applied to the radiator, prior tofinalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIEDPROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.

INTRODUCTIONThe Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Décor Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness anddependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.

CAUTIONStep 1 Read this entire instruction manual thoroughly before beginning installation.

Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all the instructions carefully .

Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.

APPLICATIONMyson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom-mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS.

INSPECT FOR DAMAGENOTE: Inspect materials for concealed shipping damage. You only have 11 days to file a freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690.

INSPECTION FOR COMPLETENESSUnpack the Décor Radiator carefully to avoid damage or loss of parts. The Décor Radiator will come with the following parts:

• Wall brackets

• Plastic inserts for noise suppression

• Stainless steel solid plug

• Vent plug

IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONALINSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.

Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.

DESIGN AND LAYOUT CONDITIONSMyson Décor Radiators should only be used with a recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Décor radiator is below a window where it can minimize downdrafts from glazed areas.

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Page 4: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

Radiators

DECOR convectors and horizontal heating panels are radiators in fully welded designs, with either 1 to 5 layers of steel rectangular water-flow tubes arranged one-behind-the-other (for convectors), or 1 or 2 such layers (for horizontal heating panels). In each layer, the convectors have between one and four tubes arranged one-above-the-other; the horizontal heating panels have from 2 to 11 tubes.

DECOR vertical heating panels consist of 1 or 2 layers of steel rectangular water flow tubes, arranged one-be-hind-the-other, with 6 to 10 steel pipes, arranged side-by-side.

A 5/62" space between the heating pipes guarantees additional resistance to corrosion. DECOR convectors and horizontal heating panels come with side panels and top covers; DECOR

vertical heating panels come with side panels. DECOR heating panels are delivered with welded mounting bra-ckets. (Except the 2H)

All DECOR convectors and heating panels are also delivered with factory-sealed drain plugs and pivotable vent plugs. (Exception: bottom-opposite-end connection models come with a dummy plug instead of the drain plug.)

Standard design: rectangular steel tubes 2-3/4" x 7/16" x 16 ga. High-pressure design: rectangular steel tubes, 2-3/4" x 7/16" x 14 ga.

Baseboard dimensions: 2HOverall lengths: between 23-5/8 inches and 118-1/8 inches Overall height: 5-9/16 inches (2 panels)

Horizontal radiator dimensions: 3H - 11HOverall lengths: between 23-5/8 inches and 94-1/2 inchesOverall heights: between 8-7/16 inches (3 panels) and 31-1/8 inches (11 panels)

Vertical radiator dimensions: 5V - 10VOverall lengths of: 14-1/8, 16-15/16, 22-5/8, and 28-1/4 inches Overall height: 78-3/4 inches

Coatings:1. Undercoat: electrophoretic, using water-soluble paints,

conforming to DIN 55900 part 1, stoved at 329° F; 2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2,

in a state-of-the-art facility. (On request, and at a supplementary charge, a range of RAL and sanitary ware colours can be offered.) This particularly robust coating is stoved at an object temperature of 356° F.

Packaging: 1. Cardboard packaging2. Edge protection3. Shrink foil

DECOR product descr ipt ion

Quality certif icates

MYSON offers its customers strong brands that meet highest quality standards. All the production sites’ production processes are certifi ed ac-cording to ISO. The quality and perfor-mance specifications of the convectors and heating panels have been verifi ed by recognised European institutions.

The standards that the quality certifi -cates require us to maintain give you security, the best heating performance and premium product quality. For the MYSON warranty conditions, please refer to the table of contents page of this manual.

Strong brands of the highest quality

Connections:2 x internal thread G 1/2“ BSP, welded-in for supply and return. Vent and drain plugs (or dummy plug) are factory sealed and are fi tted according to the customer’s specifi cations.

Maximum positive operating pressureStandard design: 72 psi

Maximum positive operating pressure: High-pressure design Special Order(supplementary charge): 116 psi

Maximum operating temperature: 230° Fm

ax.

72psimax.

116psimax.

04

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

P R O D U C T D E S C R I P T I O N 6 H 2 2 0 9 0

Overall Length [mm]

Number of Convector Rows [depth]

Number of Panel Rows [depth]

Panel Orientation Horizontal/Vertical

Number of Panels

Additional sizes and models are available as special order

Page 5: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR model overview / connect ion dimensions

Overall height [in]

Horizontal & Vertical design, H & V models

**100 **120 **140 **160 **180 **200 **220 **240

23-5/8" 31-1/2" 35-7/16" 39-3/8" 47-1/4" 55-1/8" 63" 70-7/8" 78-3/4" 86-5/8" 94-1/2"Overall length

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Sid

e C

on

ne

ctio

ns:

All Dimensions are nominal

05

H34

6-7/8"

1-7

/8"

H11 1"

H22 1-7

/8"

3-11/16"

Tapping spacing [in]

2-11/16"

8-7/16"

5-5/8"

11-1/4"

16-15/16"

22-5/8"

31-1/8"

Overall Heights Overall Lengths

22-5/8" 31-1/8"

21" 29-1/2"

2-11/16"

V11

78

-3/4

"

V111

"3/16"3/16"

2-11

/16"

Model Height 8H 11H

13/16" Typical

Overall Length

Overall length

Vertical Model 6V11 8V11 10V11

16-15/16" 22-5/8" 28-1/4"

2H 3H 4H 6H

5-5/8" 8-7/16" 11-1/4" 16-15/16"

4" 6-7/8" 9-9/16" 15-3/8"

Model Length **060 **080 **090

76

-3/4

"

5V11

14-1/8"

**300

118-1/8"

Page 6: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR piping & rough-in

H and V models

Suitable for mono-flo, home run or 2-pipe systems

Top-bottom, opposite-end, side-connection, right-side supply

Top-bottom, opposite-end, side-connection, left-side supply*

Bottom-only, opposite-end, side-connection, right-side supply

Note: 5% reduced heat output

Rough-in dimension shown at right is for a TRV and a LKD valve or a pair of LKD valves. When using FF valves add 3-5/8" to overall length.

Recommendation: Radiator tappings and valve spuds are 1/2"BSP. Professional expertise is required when sealing these "straight" threads. Failure to properly seal the connections will result in leaks resulting in property damage.

NOTE ! Myson is not responsible for damage resulting from improper workmanship.

NOTE ! Rough-in information is given for Myson control valves. Valve specifications vary by manufacturer. Myson will not be responsible for damage or repair of property resulting from the use of non-Myson valves.

06

*Plug & Vent location as shipped:

V

P

V

P

V P P V

Overall Length + 3-1/2"

LKD16AN FF16WAC TRV

• All installations require 2 valves per radiator

• All valves are ½” BSP thread for connection to theradiator and ½” NPT thread for connection to thesystem (also includes compression nut and ferrulefor connection to ½” copper)

• Valves are available in 3 basic patterns: angle,straight, and inverted angle (TRV only)

• Basic Installation: use 2 – LKD16AN (angle) orLKD16SN (straight) manual valves, nickel plated withscrewdriver stops and caps

• Basic upgrade: use 1 - FF16WAC and 1 - FF16LACmanual valves, angle only, chrome plated with whitehandles (FF16WAC is adjustable for balancing,FF16LAC is fixed open but can be closed for service)

• TRV (thermostatic radiator valves) are available forautomatic temperature control of individual radiators:available in 3 body patterns, with or withoutthermostatic head (sensor), use in conjunction withLKD or FF

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Bottom-only, opposite-end, side-connection, left-side supply

Note: 5% reduced heat output

NOTE: See page 8 for rough-in from finished wall to pipe centers.

See page 14 for additional valve information

Page 7: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR welded bracket posit ion

H models

H11/H22 L-BRACKET 300

Overallheight

8-7/16"

Overallheight

11-1/4"

23-5/8" - 78-3/4"

A A

3-3/8"

4-3/4"

A A1/2 1/2

86-5/8" - 94-1/2"

5-1/8"

4-3/4"

23-5/8" - 78-3/4"

A A

1-9

/16

"

A A

86-5/8" - 94-1/2"

1/2 1/2

1-9

/16

"

2-3/8"

9/1

6"

H11 H22

07

H11/H22 L-BRACKET 400

Overallheight

16-15/16"

5-1/8"

8-11/16"

23-5/8" - 78-3/4"

A A A A

86-5/8" - 94-1/2"

1/2 1/2

Overallheight

from22-5/8"

to31-1/8"

5-1/8"

16-1/2"

23-5/8" - 78-3/4"

A A

130

420

A A

86-5/8" - 94-1/2"

1/2 1/2

H11/H22 L-BRACKET 600

A = 6-5/16"

1-9

/16

"

2-3/8"

9/1

6"

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Page 8: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR bracket posit ions

V11 H11 H22 models

WA 11Bracket

2-3/8" 9/1

6"

08

16-15/16" - 28-1/4"

78

-3/4

"

5-1/

8"

4-1/4"4-1/4"

3-9

/16

"

1-9

/16

"

Model V11 WA11-BRACKET

1-3/4"

70

-1/1

6"

H34 pedestal model Floor Stand KOMFOOT-1: posit ioning

KOMFOOT-1

H34

Measurement X: chosen distance between the wall or window surface and the back of the convector.

5-7/8" 5-7/8"

1/2overall length

6-9

/16

"

6-7

/8"

X

3-1

/2"

1/2 overall length

constantconstant

H11/H22 L-BRACKET

Note: For an overal l length of 86-5/8" and greater, a 3rd stand console must be used!

W

Measurement W H11 = 1-11/16" H22 = 3-7/16"

PLEASE NOTE: The brackets provided are only intended for installation on walls made of solid wood, bricks, concrete or on timber-frame stud walls where the fixing is into the timber. For walls made of other materials, for example hollow bricks, please consult your installer and/or specialist supplier. ONCE AGAIN, IF YOU ARE UNSURE, IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.

4" Minimum L-Bracket

XMeasurement X H11 = 3-3/8" H22 = 5 -1/4"

3-3/8"

Note: For H11 and H22 models with an overal l length of 86-5/8" and greater 3 brackets are required.

Note: For more detai led L-bracket instal lat ion dimensions and mounting posit ions please consult the Assembly Instruct ions included with the mounting brackets.

Note: The L-Bracket is not for use with 2H11 model. please refer to page 09 for 2H11 mounting detai ls .

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Page 9: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR model 2H Baseboard mounting detai l / Start-up & Maintenance

Horizontal & Vertical design, H & V models

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

09

2H11 1"

2-11/16"

5-5/8" 4"

3-3/16" Minimum

1-7/16"

3-1/8"

BBCB Bracket

BBWB Bracket

BBWB shown with foam spacer typical on all lower bracket locations.

Rear view of typical upper and lower bracket (BBCB + BBWB) locations.* Upper brackets should be fastened to studs or blocking**when installed on frame construction. * Upper brackets should be installed at a recommended minimum of 32" intervals. * Lower brackets with foam backer used for bottom of panel standoff should be spaced between upper brackets as required.

Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty.

Step 1 Fill and vent the system.

Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.

Step 3 Shut off and drain the system while the water is still hot.

Step 4 Refill the system.

Step 5 Reheat, vent, and balance the system.

Step 6 Once the Décor Radiator is filled with water the system should be left filled.

Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.

SYSTEM START-UP

MAINTENANCE & CLEANING1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion.

2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of yourMyson Décor Panel Radiator.

3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty.

Page 10: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR heat ing outputs 10

Heating output as calculated using an AWT shown and EAT of 70° F

8-7/16"

11-1/4"

2H11

4H11

5-5/8"

Overall depth

2-11/16"

Mode l

Overallheight

Overalllength

47-1/4"

55-1/8"

70-7/8"

86-5/8"

94-1/2"

23-5/8"

35-7/16"

Model

16-15/16"

6H11

963

1445

Output [btuh] 180° F 160° F 140° F

691 1235

1852 1037

2469 1926

16132881

1383

2247

3704

2535

2889 2074

4527 3531

3852 27654938

Output [btuh]

1216

1828

180° F 160° F 140° F

873 1558

2343 1312

3122 2436 1749

4681

3205

3651 2621

5724 4464

4871 34976245

Output [btuh]

1513

2269

180° F 160° F 140° F

1086 1940

2909 1629

3879 3026 2172

5825

3984

4543 3262

7144 5549

6056 43487764

Output [btuh]

2252

3002

180° F 160° F 140° F

1617 2887

3849 2155

4811 3753

37726736

2694

5254

8660 6755 4850

118-1/8" 4815 34576173

63" 3292 2568 1844 4160 3244 2329

5174 4036 2898

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Watercontent gals.

Weight lbs.

Watercontent gals.

Weight lbs.

10.28 .18

.26

.35

.40

.46

.52

.63

.69

.87

15.00 .26

.39

.52

.70

.78

.95

1.04

3H11

Overall depth

2-11/16"

Overallheight

Overalllength

47-1/4"

70-7/8"

86-5/8"

94-1/2"

23-5/8"

35-7/16"

63"

31-1/2"

39-3/8"

Watercontent gals.

Weight lbs.

19.20 .36

.53

.71

.95

1.06

1.30

Watercontent gals.

Weight lbs.

26.27 .52

.69

.87

1.22

1.56

1.42

55-1/8"

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

__ __ __ __ __

22.33

44.65

54.57

59.54

39.69

29.77

28.81

38.42

51.22

57.62

70.43 76.83

35.03

43.79

61.30

78.82

23.98

27.41

30.83

37.68

41.11

51.38

20.55

15.42

Page 11: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR heat ing outputs 11

Heating output as calculated using an AWT shown and EAT of 70° F

Overall

depth 2-11/16"

Overallheight

Model

Overalllength

23-5/8"

31-1/2"

39-3/8"

55-1/8"

70-7/8"

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Overall

depth 2-11/16"

Overallheight

22-5/8" 31-1/8"

Model 8H11 11H11

Overalllength

23-5/8"

31-1/2"

39-3/8"

55-1/8"

70-7/8"

2731

3639

Output [btuh]

180° F 160° F 140° F

1960 3501

4665 2613

5830 4548

45708160

3265

6365

10496 8187 5878

Output [btuh]

3274

4365

180° F 160° F 140° F

2350 4147

5596 3134

6995 5456

54849793

3917

7639

12591 9821 7051

Watercontent gals.

Weight lbs.

34.59 .71

.95

1.18

1.66

2.13

Watercontent gals.

Weight lbs.

44.39 .97

1.29

1.62

2.26

2.91

22-5/8"

8H22

16-15/16"

6H22

4207

5606

Output [btuh]

180° F 160° F 140° F

3021 5394

7187 4025

8988 7010

704512581

5033

9813

16175 12616 9058

4985

6650

Output [btuh]

180° F 160° F 140° F

3579 6391

8526 4744

10654 8310

835314917

5966

11635

19180 14960 10741

Watercontent gals.

Weight lbs.

48.86 1.06

1.42

1.77

2.48

3.19

Watercontent gals.

Weight lbs.

64.85 1.42

1.89

2.36

3.31

4.25

46.12

57.65

80.70

103.76

59.19

74.00

103.58

133.18

65.14

81.43

114.00

146.57

86.47

108.09

151.32

194.55

Page 12: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

Heating output as calculated using an AWT shown and EAT of 70° F

DECOR heat ing outputs 12

Overall depth 3-11/16"

Overallheight 31-1/8"

Model

Overalllength

23-5/8"

31-1/2"

39-3/8"

55-1/8"

70-7/8"

5-5/8"

2H34

Overall depth 6-7/8"

Overallheight[less feet]

Model

Overalllength

39-3/8"

55-1/8"

70-7/8"

86-5/8"

11-1/4"

4H34

Output [btuh]

5909

7877

180° F 160° F 140° F

4242 7575

10098 5655

12621 9845

989417667

7068

13780

22720 17721 12723

7258

Output [btuh]

180° F 160° F 140° F

3722 6647

9306 5211

11964 9332

818914623

6700

11406

8508

11910

Output [btuh]

180° F 160° F 140° F

6108 10907

15629 8551

19630 15312

1343923998

10993

18719

Note: H28 Pedestal models require KOMFOOT-1 feet for instal lat ion.

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

Watercontent gals.

Weight lbs.

83.45 1.94

2.58

3.25

4.52

5.81

78-3/4"

V11

4424

5901

Output [btuh]

180° F 160° F 140° F

3176 5671

7565 4237

9459 7378 5298

4719 3681 2643

Watercontent gals.

Weight lbs.

58.30 1.32

1.58

2.11

2.63

Overall depth 2-11/16"

Overallheight

Overalllength

14-1/8"

16-15/16"

22-5/8"

28-1/4"

Watercontent gals.

Weight lbs.

52.77 .87

1.22

1.56

1.91

Watercontent gals.

Weight lbs.

102.38 1.79

2.48

3.19

3.90

11H22

5185

111.26

139.07

194.70

250.33

69.90

93.38

116.59

73.87

94.98 116.08

143.33

184.28

225.23

Model

Page 13: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

Typical hydronic system types

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

13

The following drawings are general examples. Consult a certified heating professional for your specific application.

DECOR optional piping arrangements

Page 14: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

DECOR valve select ion

Valve application

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

14

All installations require 2 valves per radiator

All valves are ½” BSP thread for connection to the radiator and½” NPT thread for connection to the system (also includes compression nutand ferrule for connection to ½” copper

Valves are available in 3 basic patterns: angle, straight, and inverted angle (TRV only)

Basic Installation: use 2 – LKD16AN (angle) or LKD16SN (straight)manual valves, nickel plated with screwdriver stops and caps

Basic upgrade: use 1 ‐ FF16WAC and 1 – FF16LAC manual valves, angleonly, chrome plated with white handles (FF16WAC is adjustable forbalancing, FF16LAC is fixed open but can be closed for service)

TRV (thermostatic radiator valves) are available for automatic temperature control of individualradiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunctionwith LKD or FF

TRV remote sensors and adjusters available for special applications

DCK12 – 4” chrome nipple with compression connection available for use with all Myson valves,includes escutcheon (connects valve to heating system)

DAV12 – same as DCK12 with addition of integral ball stop angle valve

Decorative pipe covers and escutcheons available in chrome or white (useto cover exposed copper pipe used in radiator installation)

   LKD16AN     LKD16SN    FF16WAC      FF16LAC    TRV angle w/HEAD

 Remote Sensor      Remote Adjuster     TRV straight    TRV inverted angle      TRV HEAD only 

DCK      DAV 

Page 15: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

NOTES

Notes

Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

15

Page 16: Decor VN Radiator Series MYSON Installation & Technical GuideINTRODUCTION The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase

heatingthroughinnovation.

MYSON Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com

DEC

OR

9/20

13