From: HPCConnection To: HPCConnection Subject: FW: Deadline 4 Date: 05 May 2015 16:01:56 Attachments: Alternatives_to_overhead_highvoltage_electricity_transmission_lines_Fac....pdf EMI and the Pacemaker Patient Rev C Sep 2012.pdf Gas_Insulated_Transmission_Lines_Reliability__Availability.pdf GIL JIC07_A36.pdf IEE_GIL_0306.pdf Korpinen Powerline PAacemaker 2012.pdf Siemens quoted installation rate 23 April 2015.pdf From: Dr. Hugh Pratt [mailto Sent: 05 May 2015 13:45 To: HPCConnection Cc: Chris Ambrose Subject: Deadline 4 Dear Tayo Thank-you for your email and help. Here are more documents referenced or requested during examination. Probably one or more are already on file. Yours sincerely, Dr. Hugh Pratt

Transcript of Dear Tayo Thank-you for your email and help. Here are more ... · PDF fileGas Insulated...

  • From: HPCConnectionTo: HPCConnectionSubject: FW: Deadline 4Date: 05 May 2015 16:01:56Attachments: Alternatives_to_overhead_highvoltage_electricity_transmission_lines_Fac....pdf

    EMI and the Pacemaker Patient Rev C Sep 2012.pdfGas_Insulated_Transmission_Lines_Reliability__Availability.pdfGIL JIC07_A36.pdfIEE_GIL_0306.pdfKorpinen Powerline PAacemaker 2012.pdfSiemens quoted installation rate 23 April 2015.pdf

    From: Dr. Hugh Pratt [mailto Sent: 05 May 2015 13:45To: HPCConnectionCc: Chris AmbroseSubject: Deadline 4DearTayoThank-youforyouremailandhelp.Herearemoredocumentsreferencedorrequestedduringexamination.Probablyoneormorearealreadyonfile.Yourssincerely,Dr.HughPratt

    mailto:/O=DCLGORG/OU=EXCHANGE ADMINISTRATIVE GROUP (FYDIBOHF23SPDLT)/CN=RECIPIENTS/CN=HPCCONNECTIONmailto:[email protected]
  • www.hinkleyconnection.co.uk 01

    Image: Cable swathe

    Alternatives to overhead high voltage electricity transmission lines

    As part of the development of the Hinkley Point C Connection Project National Grid has considered a range of other technology options including high-voltage direct current (HVDC) Subsea cables, Underground cables and gas insulated lines (GIL).

    National Grid has installations of each technology in the UK, and therefore has substantial operational experience of each.

    Cost is an important factor in our assessment as this passes through to the electricity bills of industry and domestic consumers, but a number of other factors contributed to why these options are not proposed for the Hinkley Point C Connection Project.

    HVDC Subsea cables

    The technical requirements needed for this project go beyond any application of the technology worldwide. This posed a huge risk for the connection of the proposed nuclear power station

    There would be effects on the internationally important designated environmental sites along the Severn Estuary

    Due to the complexity of installation, construction timescales within the Estuary would be very significant and could pose a risk for the connection of the proposed nuclear power station

    There is a risk of damage to undersea cables in the Estuary due to powerful tidal movements, and from anchorage

    HVDC requires large above ground infrastructure at either end of the route, giving rise to siting, planning and environmental issues

    Underground Cables

    Involve higher cost than overhead lines but lower cost than GIL and HVDC

    Require above ground cable sealing end compounds

    Require a very large and disruptive construction & operational swathe

  • www.hinkleyconnection.co.uk 02

    Image: Cable sealing end compound

    Image: GIL swathe

    Would cause substantial effects on hydrology due to the number of water courses and drainage ditches in the Somerset Levels South and North

    Would also affect a range of environmental features, including archaeology and ecology

    Gas-Insulated Transmission Lines (GIL)

    Untested on the scale required. The longest installation worldwide to date is approx 1km (Frankfurt Airport, Germany)

    The highest cost technology

    Uses a Nitrogen and SF6 a greenhouse gas to provide insulation

    The capacity requirements of the Hinkley Point C Connection Project would mean a deep underground tunnel would be required

  • www.hinkleyconnection.co.uk 03

    Image: GIL section

    Image: GIL tunnel

    Requires permanent tunnel access and above ground ventilation for gassing, testing and cooling

    There would also be effects on a range of environmental features including archaeology, ecology and character of the Somerset Levels South and North.

    Longest construction timescales of all technology options

    For GIL technology videos please visit Siemens

    http://www.energy.siemens.com/hq/en/power-transmission/gas-insulated-transmission-lines.htm

  • Technical Insight September 2012

    TI02-001 Rev C Technical Services 15900 Valley View Court Sylmar, CA 91342-3577 800 722 3774

    ELECTROMAGNETIC INTERFERENCE

    AND THE PACEMAKER PATIENT

    While clinically significant problems with electromagnetic interference (EMI) are rare,

    a pacemakers response to EMI becomes more diverse as technology advances.

    Pacemaker manufacturers continue to develop interference protection circuitry to keep

    up with these vast sources of EMI.

    The pacemakers response to EMI is dependent on the characteristics of the EMI,

    proximity to the interference, available shielding, and the sensing characteristics and

    polarity of the pacemaker. The pacemaker circuitry is designed to attenuate any

    interference outside the normal intracardiac range (10 Hz - 100 Hz). This is achieved

    by using bandpass filters.

    EMI sources can be broadly classified as galvanic, electromagnetic or magnetic.

    Galvanic interference requires direct contact with electrical current. This is most often seen in defibrillation/cardioversion, cautery,

    Transcutaneous Electrical Nerve Stimulator units and diathermy.

    Electromagnetic or electrically coupled interference does not require direct body contact. This interference is most often seen with arc welders,

    radio transmitters, electrical appliances, metal detectors, therapeutic

    ultrasound and high voltage power lines.

    Magnetic interference occurs when a patient comes in close proximity with an intense magnetic field. This is often seen in nuclear magnetic

    resonance imaging (NMR/MRI) and steel mill induction furnaces.

    EMI with signal modulation can mimic normal intracardiac signals. When detected, the

    response to EMI may present itself as a single beat inhibition, total inhibition, noise

    reversion/asynchronous pacing, rate increase, erratic pacing, or no output. These

    responses are usually temporary, but can be permanent if the pulse generator circuitry is

    damaged.

    A pacemakers response to EMI is highly dependent on the specific EMI source, the

    pacemakers mode, and sensing polarity. Included is a list that details the interaction of

    commonly encountered pacemaker EMI sources. Accompanying this list is a summary

    table of these common EMI sources and the potential device responses. For specific

    instructions for use and suggested recommendations for a given pacemaker model,

    please refer to the manufacturers Users Manual.

    If you have any questions or would like to discuss this topic in greater detail, please do not

    hesitate to contact Technical Services at 800-722-3774.

  • Technical Insight Page 2

    TI02-001 Rev C Technical Services 15900 Valley View Court Sylmar, CA 91342-3577 800 722 3774

    Common Sources of EMI

    Ablation (RF): Loss of capture - exit block is frequently seen during RF ablations. Arrhythmia induction, undersensing,

    inhibition, rate increase and noise reversion pacing are also possible. Circuit damage is less likely than DC ablation.

    Acupuncture: Low frequency electroacupuncture may cause inhibition and noise reversion at high frequencies.

    Airport detector/Metal detectors: Single beat inhibition is rare and seen only on unipolar devices.

    Anti-theft devices/Electronic Article Surveillance (EAS): Possible inhibition or rate increase reported primarily on unipolar

    devices especially if patient leans or lingers near EAS. An increased incidence of cross-talk is seen on unipolar DDD

    pacers.

    Arc welders: Single beat inhibition is commonly seen on unipolar devices each time the arc is struck. High magnetic fields from

    the cables may cause reed switch closure resulting in asynchronous pacing.

    Auto Smart Key: No effect.

    Bone Stimulator: Possible inhibition on unipolar devices.

    Cardioversion: Cardioversion, performed at high energies similar to that of defibrillation or performed directly over the pulse

    generator, may damage circuitry resulting in no output, erratic pacing, or rate increases. Energy conducted through the

    lead may cause arrhythmias and myocardial burning.

    Cautery: Cautery used near the pacing system may result in inhibition, asynchronous pacing and/or circuit damage. Energy

    conducted through the lead may cause arrhythmias and myocardial burning. Impedance-based rate responsive pulse

    generators may exhibit erratic pacing or rate increases. A Shaw scalpel uses non-electric cautery that is thermally coupled

    and will not cause any interference.

    CB radio: Single beat inhibition may be seen with microphone keying on unipolar devices.

    Cellular Phone: Total inhibition or asynchronous pacing is possible with some digital cell phones if placed within 6 inches of

    the pacemaker. SJM pacemakers implanted since the late 1980s are cellular tested and should not be affected by cellular

    phones.

    CT Scan/PET Scan: No documented reports of capture or sensing anomalies. Possible sensor driven pacing up to programmed

    Maximum Sensor Rate.

    Defibrillation: Defibrillation performed at high energies, or defibrillation directly over the pulse generator, may damage

    circuitry resulting in no output, erratic pacing, or rate increases. Energy conducted through the lead may cause