De Beleving van Daglicht - Nicolas Roy
-
Upload
material-design -
Category
Design
-
view
1.612 -
download
0
description
Transcript of De Beleving van Daglicht - Nicolas Roy
![Page 1: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/1.jpg)
VELUX Daylight Visualizer 2 An Intuitive and User-Friendly Simulation Tool for
Accurate Daylighting Predictions
Daylighting Seminar, 26 May 2010
Nicolas Roy, ArchitectVELUX A/S, Department of Daylight, Energy and Indoor Climate
![Page 2: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/2.jpg)
VELUX Daylight Visualizer 2
Lighting engine
• Global illumination using bidirectional Monte Carlo ray tracing and photon mapping.
Main objectives
• Provide professionals with an accessible and user-friendly tool which can perform accurate daylight simulations.
• Predict and document daylight levels and appearance of a space prior to realization of the building to promote good daylighting design.
Target group
• Building professionals/architects/engineers/students
• Professional house builders/developers/specifiers
![Page 3: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/3.jpg)
Input areaUser input area includes predefined settings, product databases (windows) and numerical entries
Edit viewA view from the top is used to define the 3D model and insert windows
• Pan• Zoom in• Zoom out• Fit• Measure
Intuitive user interface
Screenshot of Daylight Visualizer 2 user interface
Progress barSimulation process has been divided into 8 distinctive steps • Floor/Plan• Roof/Ceiling• Windows/Doors• Surfaces• Furniture• Location• Camera• Render
3D viewThe model can be viewed in real time as a ”wire shaded” rendering
• Zoom in• Zoom out• Fit
Section viewThe model can be viewed as a ”wireframe” section
• Pan• Zoom in• Zoom out• Fit• Measure
Guidance textStep by step instructions following the user actions
3D Modeller
![Page 4: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/4.jpg)
Intuitive user interface
Screenshot of Daylight Visualizer 2 user interface – 3D Importer
3D Importer
Progress barSimulation process has been divided into 5 distinctive steps
• Scale/Units• Surfaces• Location• Camera• Render
Plan viewThe 3D Importer uses a ”Plan” view instead of an ”Edit” view
• Pan• Zoom in• Zoom out• Fit• Measure
![Page 5: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/5.jpg)
Intuitive user interface
Screenshot of Daylight Visualizer 2 user interface
Perspective camera
Camera previewThe 3D view changes to a camera preview when defining the perspective view
Perspective viewA perspective view is defined by placing and orienting the camera icons in the ”Plan” and ”Section” view ports
![Page 6: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/6.jpg)
Predefined settingsDaylight Visualizer 2 uses predefined settings to ensure realistic inputs and the validity of the models and simulations.
Screenshot showing the assignment of predefined surface properties.
Screenshot showing the predefined render specifications for still images.
Custom settingsUser defined settings can also be specified in order to ensure a good level of flexibility
![Page 7: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/7.jpg)
Efficient workflowUsers can perform quick comparisons between different scenarios such as window layout, pane properties, room surfaces, sky conditions, locations, and orientations.
Room 1 Room 2 Room 3
![Page 8: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/8.jpg)
Efficient workflowUsers can perform quick comparisons between different scenarios such as window layout, pane properties, room surfaces, sky conditions, locations, and orientations.
Room 1 Room 2 Room 3
![Page 9: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/9.jpg)
Results and metrics
Luminance
Daylight Visualizer 2 uses recognized metrics and performance indicators, including luminance (cd/m2), illuminance (lux) and daylight factor (%).
Illuminance Daylight factor
![Page 10: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/10.jpg)
Results and metricsRendered images can be viewed in photorealistic, false colour and/or ISO contour modes.
Photorealistic False colour ISO contour
![Page 11: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/11.jpg)
Results and metricsSimulations can be performed as still images, annual overviews and animations.
![Page 12: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/12.jpg)
Validation against CIE 171:2006
Description of test case 5.9 (CIE 171:2006)
Description of test case 5.7 (CIE 171:2006)
Average error between the simulation results obatined with Daylight Visualizer 2 and the CIE 171:2006 analytical references (ENTPE)
Calculations have been validated against CIE 171:2006,Test Cases to Assess the Accuracy of Lightning Computer Program, in collaboration with ENTPE, l‘École Nationale des Travaux Publics de l‘État in France.
![Page 13: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/13.jpg)
Validation against CIE 171:2006
Conclusions from ENTPE’s report
• VELUX Daylight Visualizer 2 can accurately predict daylight levels and appearance of a space lit with natural light, prior to realization of the building design.
• VELUX Daylight Visualizer 2 passed the CIE 171:2006 test cases dedicated to natural lighting.
• For the custom setting, VELUX Daylight Visualizer 2 simulates natural light transport with a maximal error lower than 5.13 %, and an average error lower than 1.29 %.
![Page 14: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/14.jpg)
ExampleHome for Life (Aarhus, Denmark)
Illuminance renderings – Overcast sky conditions
![Page 15: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/15.jpg)
ExampleHome for Life (Aarhus, Denmark)
Luminance renderings – Sunny sky conditions
![Page 16: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/16.jpg)
ExampleHome for Life (Aarhus, Denmark)
Luminance renderings – Overcast sky conditions
![Page 17: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/17.jpg)
ExampleHome for Life (Aarhus, Denmark)
Daylight factor simulations
Ground floor First floor
![Page 18: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/18.jpg)
ExampleHome for Life (Aarhus, Denmark)
Luminance renderings – Annual overview – Sunny sky conditions (21st at 12:00)
DecemberNovemberOctoberSeptember
AugustJulyJuneMay
AprilMarchFebruaryJanuary
![Page 19: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/19.jpg)
ExampleHome for Life (Aarhus, Denmark)
Luminance renderings – Annual overview – Sunny sky conditions (21st at 12:00)
DecemberNovemberOctoberSeptember
AugustJulyJuneMay
AprilMarchFebruaryJanuary
![Page 20: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/20.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Daylight factor simulation (0.85m above the ground)
![Page 21: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/21.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Group room 2
Luminance and illuminance levels - 21/12 at 12 o’clock, with intermediate sky
![Page 22: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/22.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Group room 2
Luminance and illuminance levels - 21/3 at 12 o’clock, with intermediate sky
![Page 23: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/23.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Group room 2
Luminance and illuminance levels - 21/6 at 12 o’clock, with intermediate sky
![Page 24: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/24.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Group room 6
Luminance and illuminance levels - 21/6 at 12 o’clock, with intermediate sky
![Page 25: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/25.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Circulation area
Luminance and illuminance levels - 21/6 at 12 o’clock, with intermediate sky
![Page 26: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/26.jpg)
ExampleSolhuset kindergarten (Hoersholm, Denmark)
Design iteration
Initial design
The daylight conditions in the initial design are evaluated using the daylight factor (DF) performance indicator.
The simulation shows the areas of the building where the light levels are not sufficient, such as the gymnastic room located in the central part and the dining room facing east (e.g. 5% DF instead of 2% DF). By contrast, it shows high light levels in certain areas which could be used better if re-distributed.
Revised design
A revised window layout is proposed based on the findings made in the first evaluation, aiming to reach adequate light levels in the central parts of the building. This new model also included angle openings of the window linings.
The light levels obtained in the central part of the building and the dining room are much higher than in the previous model, ensuring that all the activity rooms have sufficient daylight.
Final design
According to the architect, the number of windows and size of the window linings opening has been optimized in the final design to promote a more rational solution in terms of ceiling construction, while keeping a generous and good distribution of daylight inside the rooms.
The daylight factor simulation of the final design shows a significant improvement over the results obtained with the initial design.
![Page 27: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/27.jpg)
ExampleGeneric house (France)
Daylight factor simulations – situation without roof windows
![Page 28: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/28.jpg)
ExampleGeneric house (France)
Daylight factor simulations – situation with roof windows
![Page 29: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/29.jpg)
ExampleGeneric house (France)
Staircase
Luminance renderings – situation without roof windows
![Page 30: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/30.jpg)
ExampleGeneric house (France)
Staircase
Luminance renderings – situation with roof windows
![Page 31: De Beleving van Daglicht - Nicolas Roy](https://reader033.fdocuments.in/reader033/viewer/2022051610/549c7983b47959a0318b473c/html5/thumbnails/31.jpg)
http://viz.velux.com
• Download
• Examples
• Tutorials
• News
• Newsletter
• FAQ
VELUX Daylight Visualizer 2 website