    DDP-1 Digital Distribution Products

    6th Edition

  • 7/31/2019 DDP Instructions

    2/21

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1Table of Contents

    IntroductionDescription...................................................................................................................................................1Applications ................................................................................................................................................2

    DDP-1 ChassisDescription...................................................................................................................................................3Single Access............................................................................................................................................4-5Dual Access .................................................................................................................................................6Special Application ...................................................................................................................................7-8

    DDP-1 CardsDescription...................................................................................................................................................9Ordering Information...................................................................................................................................9Schematics ...........................................................................................................................................10-12

    DDP-1 BaysRack Assembly Guidelines .........................................................................................................................13Rack and Hardware Guidelines..................................................................................................................14System Line-Up..........................................................................................................................................15Rack and Hardware Ordering Information .................................................................................................16

    Rack Accessories Ordering Information......................................................................................................16

    Auxiliary Equipment .............................................................................................................................17Patch Cords..............................................................................................................................................17Index .......................................................................................................................................................18

  • 7/31/2019 DDP Instructions

    3/21

    1w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1Introduction

    The DDP-1 chassis is an interface pointplaced between a digital cross-connectsystem (DCS) and digital networkelements (NE), providing a flexiblealternative to hard wiring NEs directly

    to the DCS.

    A digital distribution point provides cabletermination and circuit access to digitalcircuits at the DS1, DS1C, E1 and VT1.5signal levels. Software cross-connectsbetween two NEs are provided by the DCS.

    DS3

    NE

    DS3

    NE

    DS3

    NE

    DS3

    NE

    DDP-3

    DS1

    NE

    DS1

    NE

    DS3PORT

    DDP-1 3/3 DCS

    DS3PORT

    3/1 DCS

    DS3PORT

    DS3PORT

    DS1PORT

    DS1PORT

    LOGICALCROSS-

    CONNECTS

    TWISTEDPAIR CABLE

    COAXIALCABLE

    Features and Benefits

    Centralized termination, interconnection and access to digital circuits between the 3/1 DCS andnetwork elements

    An alternative to hard wiring the digital telecommunications equipment directly to the 3/1 DCSbackplane

    Smooth, flexible and economical migration of service to a 3/1 DCS in an office

    In-service or out-of-service cutover options using DDP-1

    Catastrophic access options utilizing the optional jack card (monitoring in both directions from onelocation and patching options)

    Ease of adding or removing future network elements

    Improved cable management and additional cabling flexibility as the office grows

    Economic access solution since permanent jacks are not required for each circuit

  • 7/31/2019 DDP Instructions

    4/21

    2w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1Applications

    The DDP-1 is an interconnect point between a NE and a DCS port. When the DCS is installed, all circuitports are cabled to the DDP. Periodically, when NEs are added, they are cabled to the DDP instead of wiringto the active DCS backplane. Moving this routine cabling away from the DCS backplane reduces service out-ages of active circuits due to installation activities. The DDP-1 is an extension of the fragile DCS backplaneand provides a robust distribution frame for wiring of NEs as the telecommunications network evolves.

    In addition to the basic application of an interface point between the DCS and NE, the DDP-1 may be usedas a termination and access point between dedicated NEs where cross-connect flexibility is not required,such as in outside plant cabinets, huts, CEVs and on customer premises. If cross-connect flexibility is desired,then a DSX-1 may be a more appropriate product.

    Circuit access is provided by modular access cards that need only be plugged into a DDP-1 chassis whenaccess is desired. Access cards provide industry standard Bantam jacks (MONITOR, OUT and IN jacks) forconvenient monitoring, testing and patching capabilities. Patching into the OUT and IN jacks breaks the con-nection between the DCS and NE and extends the signal to a patch cord for testing and patching. TheMONITOR jack is a high impedance bridge point that is used for nonintrusive monitoring of active circuits.DDP-1 chassis are typically grouped together in a common area to concentrate installation and maintenanceactivities and allow for patching between any access point.

    During normal circuit operation, the access cards are not in line with the circuit. The DDP-1 chassis includesmake-before-break loop-through connectors that interconnect a NE to a DCS port. When access is desired,the access card is inserted into the chassis where the loop-through connection is then extended through theaccess card.

    M

    O

    I

    M

    O

    I

    DS1NE1

    DS1PORT

    A

    DS1PORT

    B

    DS1NE2

    DDP-1 POS #2

    XMITRCV

    XMIT

    RCV

    XMITRCV

    XMITRCV

    DDP-1 POS #1

    SoftwareCross-Connects

    DCS

  • 7/31/2019 DDP Instructions

    5/21

    3w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisDescription

    The DDP-1 chassis is available in two basic configurations: Single Access and Dual Access.

    Various circuit densities are available to match DCS group quantities (i.e. 56, 64, 84 circuit). Various wiringconnection styles (i.e. wire-wrap, 50-pin or 64-pin connectors) and equipment rack styles (i.e. 19", 23"mounting) are available.

    The Single Access chassis allows access to the NEside or the DCS side but not simultaneously. Anaccess card is inserted in the normal position (withmonitor jack on top) to access the NE. The accesscard is inserted in the inverted position (monitorjack on bottom) to access the DCS.

    The Dual Access chassis allows access to both theNE side and the DCS side simultaneously. Twoaccess cards are inserted in the normal position(with monitor jack on top). One access card isinserted into the top half of the chassis for the NE,and another access card is inserted into the bottomhalf of the chassis for the DCS. Full bidirectionalaccess is accommodated with the dual access chassis.

    M

    O

    I

    I

    O

    M

    DS1NE1

    DS1PORT

    A

    DCS ACCESS

    XMITRCV

    XMITRCV

    NE ACCESS

    DCS

    Software Cross-Connects to Other

    DCS Ports

    DS1

    NE1

    XMITRCV

    Software Cross-

    Connects to Other

    DCS PortsConnections

    Internal to Card

    DS1

    PORT

    A

    XMITRCV

    M

    O

    I

    M

    O

    I

    DCS

    NE

    Single Access

    Dual Access

    DCS AccessNE Access

    Software Cross-

    Connects to OtherDCS Ports

    Software Cross-

    Connects to Other

    DCS Ports

    Connections

    Internal to Card

  • 7/31/2019 DDP Instructions

    6/21

    4w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisSingle Access

    84 and 64 Termination

    *Front or rear access to equipment cable terminations is designed to meet CEV or OSP cabinet requirements.

    Note: Panel Color is Putty.

    DD1-351001Front View

    (Door Closed)

    DD1-351001Front View

    (Door Open)

    DD1-351001Rear View

    Number ofCircuits

    84

    84

    64

    64

    Cable

    ConnectionsDCS IN/OUT

    Wire-wrap

    Wire-wrap

    Wire-wrap

    64-PinReceptacle

    Connectors

    Cable

    ConnectionsNE IN/OUT

    Wire-wrap

    Wire-wrap

    Wire-wrap

    Wire-wrap

    O r d e r i n g I n f o r m a t i o n

    Cable

    TerminationAccess

    Rear

    Front or

    Rear

    Rear

    Rear

    MountingOptions

    Flush or 2"

    (5.08 cm)

    RecessEIA/WECO

    Flush

    WECO

    Flush or 2"

    (5.08 cm)Recess

    EIA/WECO

    Flush or 2"(5.08 cm)

    Recess

    EIA/WECO

    Dimensions(Height, Width, Depth)

    6 x 23 x 8.4 inches

    (15.24 x 58.42 x 21.34 cm)

    6 x 23 x 8 inches

    (15.24 x 58.42 x 20.32 cm)

    2.6 x 23 x 8 inches

    (6.6 x 58.42 x 20.32 cm)

    3 x 23 x 11 inches

    (7.62 x 58.42 x 27.94 cm)

    Catalog Number

    DD1-351001

    DD1-351000*

    DD1-321001

    DD1-322001

    6.0"

    1.75"

    22.3"

    23.0"

    DD1-351001Rear View

    DD1-351001Front View

    (Door Open)

  • 7/31/2019 DDP Instructions

    7/21

    5w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisSingle Access

    56 Termination

    8.00"

    2.00"

    23.00"

    22.31"

    CKT 1 CKT 56

    1.25"

    1.25"2.6

    DD1-311001

    Front View

    DD1-311001

    Top View

    DD1-331001

    Front View

    (Door Open)

    DD1-331001

    Front View

    (Door Closed)

    DD1-331001

    Rear View

    Note: Panel Color is Putty.

    Number ofCircuits

    56

    56

    Cable

    ConnectionsDCS IN/OUT

    Wire-wrap

    Wire-wrap

    Cable

    ConnectionsNE IN/OUT

    Wire-wrap

    Wire-wrap

    O r d e r i n g I n f o r m a t i o n

    Cable

    TerminationAccess

    Rear

    Rear

    MountingOptions

    Flush or 2"(5.08 cm)

    Recess

    EIA/WECO

    4.75" (12.07

    cm) Recess

    EIA/WECO

    Dimensions(Height, Width, Depth)

    2.6 x 23 x 8 inches(6.60 x 58.42 x 20.32 cm)

    3 x 19 x 11.5 inches(7.62 x 48.26 x 29.21 cm)

    Catalog Number

    DD1-311001

    DD1-211001

  • 7/31/2019 DDP Instructions

    8/21

    6w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisDual Access

    56 and 64 Termination

    8.20"

    2.00"

    .50"

    5.00"

    4.00"3.25"

    1.00"

    6.00"

    23.00"

    22.31"

    CKT 1 CKT 64

    DD1-331DAS

    Front View

    (Door Open)

    DD1-331DAS

    Top View

    Note: Panel Color is Putty.

    Number ofCircuits

    64

    56

    Cable

    ConnectionsDCS IN/OUT

    Wire-wrap

    Wire-wrap

    Cable

    ConnectionsNE IN/OUT

    Wire-wrap

    Wire-wrap

    O r d e r i n g I n f o r m a t i o n

    Cable

    TerminationAccess

    Rear

    Rear

    MountingOptions

    Flush or 2"

    (5.08 cm)Recess

    EIA/WECO

    5" (12.7 cm)

    Recess

    EIA/WECO

    Dimensions(Height, Width, Depth)

    6 x 23 x 8.2 inches

    (15.24 x 58.42 x 20.83 cm)

    6 x 19 x 10 inches

    (15.24 x 48.26 x 25.40 cm)

    Catalog Number

    DD1-331DAS

    DD1-241002

  • 7/31/2019 DDP Instructions

    9/21

    7w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisSpecial Applications

    *The DCS connections may be made with either DB15 or with RJ48X connectors since both are provided.

    **Special labeling and location of cable terminations are designed to meet co-location requirements.

    Note: Panel Color is Putty.

    23.00"

    22.31"

    6.00"

    .50"

    5.00"

    4.00"3.25"

    1.00"

    CKT 64CKT 1

    DD1-331003 Front View

    10.40"

    2.00"

    DD1-331003 Top View

    Number of

    Circuits

    64 (Dual

    Access)

    56 (Single

    Access)

    4 (Single

    Access)

    Cable

    ConnectionsNE IN/OUT

    Wire-wrap

    (Access 1)

    Wire-wrap

    (LEC-Front)

    5' Stub End

    Cable

    Attached

    (24GA/16PR,

    8PR Unused)

    O r d e r i n g I n f o r m a t i o n

    CableConnectionsDCS IN/OUT

    Wire-wrap

    (Access 2)

    Wire-wrap

    (CAP-Rear)

    Both DB15

    Receptacleand RJ48X

    Connector

    Cable

    Termination

    Access

    Rear

    Front and

    Rear

    Rear

    Mounting

    Options

    2" (5.08 cm)

    RecessEIA/WECO

    5" (12.7 cm)

    RecessEIA/WECO

    Wall Mount

    Dimensions(Height, Width, Depth)

    6 x 23 x 10.4 inches

    (15.24 x 58.42 x 26.42 cm)

    5 x 19 or 23 x 11.7 inches

    (12.7 x 48.26 or 58.42 x 29.72 cm)

    3 x 19 x 12.25 inches

    (7.62 x 48.26 x 31.12 cm)

    Catalog Number

    DD1-331003**

    DD1-211003**

    DD1-000002*

  • 7/31/2019 DDP Instructions

    10/21

    8w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 ChassisSpecial Applications

    12.25"

    5.00"

    4.75"

    DD1-212001

    Top View

    19.00"

    18.31"

    CKT 1 CKT 56

    1.00"

    1.00"

    .480"

    3.00"

    DD1-212001Front View

    Note: Panel Color is Putty.

    Number of

    Circuits

    56

    Cable

    Connections

    DCS IN/OUT

    Wire-wrap

    Cable

    Connections

    NE IN/OUT

    Wire-wrap

    O r d e r i n g I n f o r m a t i o n

    Cable

    Termination

    Access

    Rear

    MountingOptions

    4.75"

    (12.07 cm)Recess

    EIA/WECO

    Dimensions(Height, Width, Depth)

    3 x 19 x 12.25 inches

    (7.62 x 48.26 x 31.12 cm)

    Catalog Number

    DD1-212001

  • 7/31/2019 DDP Instructions

    11/21

    9w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 CardsDescription

    Description

    Loopback card

    Provides loopback of transmit to receive for both the NE and DCS

    equipment.

    Terminating card

    Provides 135 Ohm termination across tip and ring for transmit andreceive of both NE and DCS equipment.

    Opening card

    Provides opening of transmission path between NE and DCS.(Isolates NE from DCS for continuity testing during installation.)

    Jack access cardProvides MON, OUT and IN jacks for circuit access to NE equipment.Provides MON, OUT and IN jacks for circuit access to DCS equipment

    when the card is inverted. (Bantam jacks)

    Drop and insert card

    Provides MON, OUT and IN jacks for both the NE and DCS equipment

    for full duplex circuit access. This provides dual access functionality in

    the single access chassis. (Bantam jacks)

    Circuit guard card

    Provides circuit guard with red label for a single mounting slot withinthe chassis. This prevents insertion of an access card for high priority

    circuits.

    Monitor only card

    Provides MON jack for circuit access to the NE equipment transmit.Provides MON jack for circuit access to the DCS equipment transmit

    when the card is inverted. (Bantam jack)

    DS0 access card

    Provides jack access to voice frequency circuits when DDP-1 chassis is

    used in special analog applications.

    Start-up kit

    Kit consists of: (28) Loopback, (4) Terminating, (4) Opening, (28) Jack

    access, (4) Monitor only cards

    Module extractor tool

    Used to extract DDP-1 card from its mounting slot in the chassis

    Catalog Number

    DD1-100002

    DD1-100003

    DD1-100004

    DD1-100005

    DD1-100006

    DD1-100008

    DD1-100012

    DD1-100020

    DD1-100025

    DD1-000001

    Cards are inserted into the DDP-1 chassis only when equipment installation or maintenanceactivities are required. A variety of cards provide many functions during installation and mainte-nance activities. Each access card has a lock and release device for secure attachment in thechassis. All cards containing jacks use industry standard Bantam jacks.

    O r d e r i n g I n f o r m a t i o n

  • 7/31/2019 DDP Instructions

    12/21

    10w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 CardsSchematics

    T

    R

    T

    R

    NE OUT

    NE OUT

    NE IN

    NE IN

    T

    R

    T

    R

    DCS IN

    DCS IN

    DCS OUT

    DCS OUT

    Loopback CardDD1-100002

    T

    R

    T

    R

    T

    R

    T

    R

    NE OUT

    NE OUT

    NE IN

    NE IN

    DCS IN

    DCS IN

    DCS OUT

    DCS OUT

    R1

    R1

    R1

    R1

    Terminating Card

    R1 = 135 Ohm

    Opening Card

    DD1-100004

    T

    R

    T

    R

    T

    R

    T

    R

    NE OUT

    NE OUT

    NE IN

    NE IN

    DCS IN

    DCS IN

    DCS OUT

    DCS OUT

    DD1-100002

    DD1-100004

    DD1-100003DD1-100003

  • 7/31/2019 DDP Instructions

    13/21

    11w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 CardsSchematics

    DD1-100005

    R

    T

    SG

    R

    RN

    TN

    T

    TTN

    RN

    R

    T (NE OUT)

    R (NE OUT)

    T (NE IN)

    R (NE IN)

    SLEEVE GROUND (COMMON BUS)

    TN (DCS IN)

    RN (DCS IN)

    TN (DCS IN)

    RN (DCS IN)

    430 OHM

    (NE) IN

    100 OHM

    (NE) OUT

    MON

    Jack Access Card DD1-100005

    100 Ohm Normal Orientation

    R

    RN

    TN

    T

    T

    TN

    RN

    R

    SG

    T

    R

    R (DCS IN)

    T (DCS IN)

    R (DCS OUT)

    T (DCS OUT)

    SLEEVE GROUND (COMMON BUS)

    TN (NE IN)

    430 OHM

    RN (NE IN)

    TN (NE OUT)

    RN (NE OUT)

    (DCS) IN

    (DCS) OUT

    MON

    100 OHM

    Jack Access Card DD1-100005

    100 Ohm Flipped Orientation*

    DD1-100006

    MON

    OUT

    IN

    NTWK

    100OHM

    SLEEVEGROUND

    NETWORK OUT

    NETWORK IN

    MON

    OUT

    IN

    DCS

    100OHM

    SHIELDGROUND

    DCS OUT

    DCS IN

    430 OHM

    T

    R

    T

    R

    T

    R

    T

    R

    430 OHM

    Drop and Insert DD1-100006

    *Note: Tip and Ring are reversed in the Flipped Orientation

  • 7/31/2019 DDP Instructions

    14/21

    12w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 CardsSchematics

    RTSGRRNTNTT

    TNRNR

    T (NE OUT)

    R (NE OUT)

    T (NE IN)

    R (NE IN)

    SLEEVE GROUND (COMMON BUS)

    TN (DCS IN)

    RN (DCS IN)TN (DCS IN)

    RN (DCS IN)

    (NE) IN(PLUGGED)

    100 OHM

    430 OHM

    (NE) OUT(PLUGGED)

    MON

    INSULATOR

    DD1-100012 100 Ohm Monitor Only

    Normal Orientation

    R

    RN

    TN

    TT

    TN

    RN

    R

    SG

    T

    R

    R (DCS IN)

    T (DCS IN)

    R (DCS OUT)

    T (DCS OUT)

    SLEEVE GROUND (COMMON BUS)

    TN (NE IN)RN (NE IN)

    TN (NE IN)

    RN (NE IN)

    100 OHM

    430 OHM

    (DCS) IN(PLUGGED)

    (DCS) OUT

    (PLUGGED)

    MON

    DD1-100012 100 Ohm Monitor Only

    Flipped Orientation*

    DD1-100012

    R

    T

    SG

    R

    RNTN

    T

    T

    TN

    RN

    R

    T (NE OUT)

    R (NE OUT)

    T (NE IN)

    R (NE IN)

    SLEEVE GROUND (COMMON BUS)

    TN (DCS IN)

    RN (DCS IN)

    TN (DCS IN)

    RN (DCS IN)

    (NE) IN

    (NE) OUT

    MON

    DD1-100020 DS0, Normal Orientation

    DD1-100020 DS0, Flipped Orientation*

    R

    RNTN

    T

    T

    TN

    RN

    R

    SG

    T

    R

    R (DCS IN)

    T (DCS IN)

    R (DCS OUT)

    T (DCS OUT)

    SLEEVE GROUND (COMMON BUS)

    TN (NE IN)

    RN (NE IN)

    TN (NE OUT)

    RN (NE OUT)

    (DCS) IN

    (DCS) OUT

    MON

    DD1-100020

    *Note: Tip and Ring are reversed in the Flipped Orientation

  • 7/31/2019 DDP Instructions

    15/21

    13w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 BaysRack Assembly Guidelines

    The recommended bay layout consists of 16 chassis. Each chassis contains 56 or 64 circuits depending onthe type of DCS machine being interfaced. This rack configuration of 16 chassis provides an interface for896 circuits using the 56 circuit chassis or 1024 circuits using the 64 circuit chassis. The chassis are mountedin groups of four to match numerically to each DCS module of 224 or 256 circuits. Although there is physi-cal mounting space for more chassis, the rack is limited to these maximums for the following reasons:

    10" spacing between racks has a maximum cable capacity for up to 1024 circuits using either 600-type(22 gauge) or 1249-type (26 gauge) shielded cable.

    Often a configuration of 16 chassis corresponds numerically to the number of DS1 circuits in many DCSmachines. Example: 16 chassis x 56 circuits per chassis = 896 circuits per rack.

    The unused mounting spaces in the rack can be used for maintenance equipment such as amiscellaneous jackfield (fault location lines, order wire access, T1 maintenance lines, etc.),communication panel, fuse panel and customer provided test equipment. A fuse panel is not requiredfor DDP-1, but is required if a communication panel or test equipment is placed in the DDP-1 rack.

    The unused mounting spaces in the rack also provide room for future DDP-1 chassis when rolling over toa new DCS machine. DS1 ports from the new DCS can be terminated on the new chassis, then transferthe NE cables as they are cut into the new DCS.

    CABLESUPPORTBRACKETSIN REAR

    16

    15

    14

    13

    44

    40

    35

    30

    25

    20

    15

    10

    5

    1

    7'-0"

    25.88

    1,75

    5.00

    12.00

    5.00

    REAR

    12

    11

    10

    9

    4

    3

    2

    1

    8

    7

    6

    5

    DDP-1 CHASSIS

    Front View

    Side View

  • 7/31/2019 DDP Instructions

    16/21

    14w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 BaysRack and Hardware Guidelines

    ADC recommends placing the DDP-1 in a 7' environment to allow technicians to access circuits without theneed for ladders. When DDP-1 is installed in environments higher than 7', the chassis should be placedonly up to the 7' level. This recommendation follows existing practices for access to DSX jacks.

    Aisle spacing conforms to existing practices of 3'0" front aisle and 2'6" rear aisle spacing. This allows room

    for technicians to perform routine maintenance activities at the front of racks and for cable termination atthe rear of racks.

    Unequal flange-type racks are recommended because they provide efficient cable management for routingcables into the rack. When two racks are placed next to each other, the wide front flanges form a cableduct area between the racks. This duct area provides a cable management route for running cables vertical-ly within the rack. Adding a rack filler panel between the racks increases the cable duct area. For a full rackof DDP-1 (16 single access chassis), the recommended size of the filler panel is 10" between racks and 5"at the ends of rack lineups. This spacing provides sufficient room to add and remove cables as the networkelements (NE) and digital cross-connect system change (DCS).

    END GUARD

    5" FILLERPANEL

    UNEQUAL FLANGERACK

    10" FILLERPANEL

    NE CABLETIE BRACKET

    DCS CABLETIE BRACKET

  • 7/31/2019 DDP Instructions

    17/21

    15w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 BaysSystem Line-Up

    Guard boxes (included as part of the rack) provide a bumper at the base of the rack to prevent mobileequipment from hitting equipment chassis installed in the rack. The recommended unequal flange typerack is equipped with 5" rear and 2" front guard boxes. The DDP-1 chassis will fit within a 12" rack foot-print. A/C outlets may be placed on the guard boxes and are recommended for convenience on everythird or fourth rack.

    Recommended end guards are placed at the ends of rack lineups to protect cables routed in the ductarea. They also provide a location for bay alarm indicators and A/C light switches.

    The recommended rack installation kit provides hardware to anchor the rack to the floor and support thetop of the rack to superstructure above. Also included in the kit are cable tie brackets that attach to thesides of the rack in the duct area to provide a means to secure the DCS cables within the duct area.Twelve NE cable tie brackets attach to the rear of the rack's wide front flange. These brackets provide ameans to secure the NE cables in the same duct area and separate them from the DCS cables. The segre-gation between NE and DCS cable allows for efficient cable management as cables are added andremoved in the future. A three bay lineup with racks, filler panels, and end guards is shown below.

    One group of fourDDP-1 chassis

    interfaces to oneDCS module

    DDP-1Rack #1

    ENDGUARD

    ENDGUARD

    DDP-1Rack #2

    DDP-1Rack #3

    DCSRack #3

    DCSRack #2DCSRack #1

    5" FILLERPANEL

    5" FILLER

    PANEL

    10" FILLER

    PANEL

  • 7/31/2019 DDP Instructions

    18/21

    16w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 Rack, Hardware and Accessories

    Rack Accessories

    Contact ADC at 1-800-366-3891 for preassembled DDP-1 bays.

    O r d e r i n g I n f o r m a t i o n

    Description

    7' Rack and Hardware

    7' x 23" network rack; 2" front/5" rear guard box, EIA, putty white

    7' x 5" rack filler panel; putty white7' x 10" rack filler panel; putty white

    7' x 12" universal end guard; putty white

    9' Rack and Hardware

    9' x 23" network rack; 2" front/5" rear guard box, EIA, putty white

    9' x 5" rack filler panel; putty white

    9' x 10" rack filler panel; putty white9' x 12" universal end guard; putty white

    11'6" Rack and Hardware

    11'6" x 23" network rack; 2" front/5" rear guard box, EIA, putty white

    11'6" x 5" rack filler panel; putty white11'6" x 10" rack filler panel; putty white

    11'6" x 12" universal end guard; putty white

    Catalog Number

    PWUEF-7ER1SE

    7RFP-5NPW7RFP-10NPW

    UEGP-7NPW

    PWUEF-9ER1SE

    9RFP-5NPW

    9RFP-10NPW

    UEGP-9NPW

    PWUEF-115ER1SE

    115RFP-5NPW115RFP-10NPW

    UEGP-115NPW

    O r d e r i n g I n f o r m a t i o n

    Description

    AC outlet; putty white (2 per rack where outlets are required)

    AC raceway; putty white (2 per rack where outlets are not required)

    AC raceway filler; putty white (2 per 5" filler panel, 4 per 10" filler panel)Rack Installation Kits

    7' DDP Bays: Includes

    (1) floor mounting kit

    (1) top attachment kit for 7' rack

    (12) rack tie bracket kits(12) DDP tie bracket kits

    (1) rack ground kit for 7' rack

    9' and 11'6" DDP Bays: Includes

    (1) floor mounting kit

    (1) top attachment kit for 7' rack

    (12) rack tie bracket kits(12) DDP tie bracket kits

    (1) rack ground kit for 9' and 11'6" racks

    Catalog Number

    ACOK-PWNB

    ACB-PWNB

    AC-PWNB-RS5

    RINST-DDP7-PW

    RINST-DDP9-PW

    Rack and Hardware

  • 7/31/2019 DDP Instructions

    19/21

    17w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    DDP-1 Auxiliary Equipment and Accessories

    Three Conductor Patch Cords

    Bantam patch cords are plastic jacketed,shielded cords with molded-on plugs. Theplugs are made with molded insulationbetween conductors. Bantam patch cordsare available with single and dual three con-ductor plugs. A cord strain relief feature isincluded in the plug construction. Dualtwisted pair patch cords are recommendedfor protection against cross talk, especiallyduring switch cutovers and when patchcords over 12' are used.

    *For nickel plated patch cords, add the suffix N.

    For plenum-rated fire retardant patch cords, add the suffix PL.

    Bantam Three Conductor Patch Cords

    Dual

    Single

    O r d e r i n g I n f o r m a t i o n

    Description

    1.75" x 23" blank panel; putty white3.50" x 23" blank panel; putty white

    5.25" x 23" blank panel; putty white

    Communication panelCommunication panel headset

    Communication panel handset

    Communication panel headset/handset holder

    20 position fuse panel (1.75" x 19"); putty whiteExtender bracket kit for fuse panel (19" to 23"); putty white

    Catalog Number

    PWBP-1723PWBP-3523

    PWBP-5223

    COMP-21COMP-HDS

    COMP-HNDS

    COMP-HNR-P

    DSX-FP20HEB-17P

    O r d e r i n g I n f o r m a t i o n

    Description

    Three Conductor*Single

    1' (.3 m)

    2' (.61 m)3' (.91 m)

    4' (1.22 m)

    5' (1.52 m)6' (1.83 m)

    8' (2.44 m)

    10' (3.05 m)12' (3.66 m)15' (4.57 m)

    20' (6.1 m)

    Dual1' (.3 m)

    2' (.61 m)

    3' (.91 m)4' (1.22 m)

    5' (1.52 m)

    6' (1.83 m)

    8' (2.44 m)10' (3.05 m)

    12' (2.66 m)

    14' (4.27 m)20' (6.1 m)

    Catalog Number

    PJ712

    PJ714PJ716

    PJ718

    PJ720PJ722

    PJ1208

    PJ1210PJ1212PJ1415

    PJ1420

    PJ762

    PJ764

    PJ766PJ768

    PJ770

    PJ772PJ1308

    PJ1310

    PJ1312PJ1514

    PJ1520

    Auxiliary Equipment

  • 7/31/2019 DDP Instructions

    20/21

    18w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0

    1

    0

    /0

    0

    2

    5

    8

    DDP-1

    DigitalDistri

    bution

    Produc

    ts

    Index

    115RFP-10NPW....................................................16115RFP-5NPW ......................................................167RFP-10NPW ........................................................167RFP-5NPW ..........................................................169RFP-10NPW ........................................................16

    9RFP-5NPW ..........................................................16AAC-PWNB-RS5......................................................16ACB-PWNB...........................................................16ACOK-PWNB........................................................16CCOMP-21 .............................................................17COMP-HDS ..........................................................17COMP-HNDS ........................................................17COMP-HNR-P .......................................................17DDD1-000001 ..........................................................9DD1-000002 ..........................................................7

    DD1-100002 ..........................................................9DD1-100003 ..........................................................9DD1-100004 ..........................................................9DD1-100005 ..........................................................9DD1-100006 ..........................................................9DD1-100008 ..........................................................9DD1-100012 ..........................................................9DD1-100020 ..........................................................9DD1-100025 ..........................................................9DD1-211001 ..........................................................5DD1-211003 ..........................................................7DD1-212001 ..........................................................8DD1-241002 ..........................................................6

    DD1-311001 ..........................................................5DD1-321001 ..........................................................4DD1-322001 ..........................................................4DD1-331003 ..........................................................7DD1-331DAS..........................................................6DD1-351000 ..........................................................4DD1-351001 ..........................................................4DSX-FP20H...........................................................17EEB-17P..................................................................17PPJ1208 .................................................................17PJ1210 .................................................................17

    PJ1212 .................................................................17PJ1308 .................................................................17PJ1310 .................................................................17PJ1312 .................................................................17PJ1415 .................................................................17PJ1420 .................................................................17PJ1514 .................................................................17PJ1520 .................................................................17PJ712....................................................................17

    PJ714....................................................................17PJ716....................................................................17PJ718....................................................................17PJ720....................................................................17PJ722....................................................................17

    PJ762....................................................................17PJ764....................................................................17PJ766....................................................................17PJ768....................................................................17PJ770....................................................................17PJ772....................................................................17PWBP-1723 ..........................................................17PWBP-3523 ..........................................................17PWBP-5223 ..........................................................17PWUEF-115ER1SE.................................................16PWUEF-7ER1SE.....................................................16PWUEF-9ER1SE.....................................................16R

    RINST-DDP7-PW....................................................16RINST-DDP9-PW....................................................16UUEGP-115NPW.....................................................16UEGP-7NPW.........................................................16UEGP-9NPW.........................................................16

  • 7/31/2019 DDP Instructions

    21/21

    ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101Specifications published here are current as of the date of publication of this document. Because we are continuously improving ourproducts, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by

    contacting o r headq arters office in Minneapolis ADC Telecomm nications Inc ie s its patent portfolio as an important corporate

    Web Site: www.adc.comFrom North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080 Fax: +1-952-946-3292

    For a complete listing of ADC's global sales office locations, please refer to our web site.