Daylight & Sunlight Assessments of a Strategic Housing Development at Mount St. Mary’s, Dundrum Road, Dublin 14.
Applicant: Winterbrook Homes (MSM) Ltd. Date: 27th April 2021
Prepared by John HealyMSc Environmental Design of Buildings
1 Rathmines Road Upper, Dublin 6, D06 Y5P5 tel 01 4965340 email [email protected] web digitaldimensions.ie Digital Dimensions Ltd trading as Digital Dimensions.
DRAFT
2
1: Introduction
We, Winterbrook Homes (MSM) Ltd, intend to apply to An Bord Pleanála for planning permission for a strategic housing development at a site of approx. 1.6 ha at Mount Saint Mary’s and Saint Joseph’s, Dundrum Road, Dublin 14 (D14 P9P3 & D14 AH57).
The site consists of the former Middle House; the Small Hall; the Gate Lodge Bungalow; the former Residence Wing building; former Chapel, Oratory and Side Chapels; and associated ancillary outbuildings (Stables/Lockups and Workshops). Robert Emmet House (a protected structure, RPS. No. 18) is located immediately adjacent to the main development site.
The development will consist of a new residential and mixed use scheme to include apartments, a central public park, café, afterschool childcare facility, pedestrian routes and associated resident facilities and amenities. A detailed development description is now set out as follows:
The proposal provides for the demolition (total area of approx. 2,913.8 sq m) of (a) the existing buildings on site (ranging in height from 1 - 3 storeys) and (b) part of the granite wall along Dundrum Road. The existing Small Hall (approx. 170 sq m) is retained and reconfigured as part of the overall proposal.
The new development will provide for the construction of a new residential scheme of 231 no. apartment units in the form of 5 no. apartment blocks (Villas A to E) ranging in height from 4 to 10 storeys as follows:
• Villa A (4 storeys) comprising 40 no. apartments (23 no. 1 bed and 17 no. 2 bed units)• Villa B (4 - 5 storeys) comprising 37 no. apartments (14 no. 1 bed and 23 no. 2 bed units)• Villa C (5 - 6 storeys) comprising 40 no. apartments (11 no. 1 bed and 29 no. 2 bed units)• Villa D (5 - 10 storeys) comprising 80 no. apartments (51 no. 1 bed and 29 no. 2 bed units)• Villa E (4 - 6 storeys) comprising 34 no. apartments (16 no. 1 bed and 18 no. 2 bed units)
Each residential unit has associated private open space in the form of a terrace/balcony.
The existing Small Hall will be reconfigured to accommodate an Afterschool Childcare Facility of approx. 161 sq m. The proposal will also provide for a café of approx. 83 sq m at the ground floor of Villa E.
Residential amenity areas of approx. 308 sq m are proposed in the form of resident support services and concierge services of approx. 111 sq m at the ground floor of Villa A; a gym room of approx. 77 sq m at the ground floor of Villa D; and a glazed pavilion indoor social space of approx. 120 sq m at the fourth floor of Villa D. A roof garden residential amenity area of approx. 130 sq m is also proposed at the fourth floor of Villa D.
Works to the northern and eastern boundary of Robert Emmet House (a protected structure) include (a) the closing up of opes to the existing Small Hall; and (b) the partial removal of a link between the existing Middle House on site and the adjacent Robert Emmet House (a protected structure) at ground and first floor levels and the subsequent reconfiguration and retention of existing fire escape at ground floor level for this building on the eastern elevation.
Open space (approx. 8,200 sq m) is proposed in the form of (a) a central public park including formal gardens, lawns, play area and pedestrian and cyclist links (approx. 6,300 sq m) and (b) residential / communal open space (approx. 1,900 sq m) including the roof terrace at Villa D (approx. 130 sq m).
Basement areas (total approx. 3,372 sq m) are proposed on one level, below Villas A and B, and include parking areas, waste management and plant areas. An ESB substation (approx. 45.5 sq m) and café waste store (approx. 18 sq m) are also proposed at surface level.
A total of 118 no. car parking spaces (99 no. at basement level and 19 no. at surface level) are proposed. 20 no. spaces are reserved for Robert Emmet House (10 no. at basement level and 10 no. at surface level). 463 no. bicycle spaces (365 no. at basement level and 98 no. at surface level) and 4 no. motorcycle spaces are proposed (all at basement level).
The development shall be served via the existing vehicular access point from Dundrum Road. Upgrade works are proposed to this vehicular access point to facilitate the proposed development and to provide for improved access and egress for the overall development. New pedestrian and cyclist access points will be provided via Dundrum Road and Churchfields. Future pedestrian links to the Hawthorn Residential Estate can be facilitated subject to third party approval.
DRAFT
3
The associated site and infrastructural works include provision for water services; foul and surface water drainage and connections; attenuation proposals; permeable paving; all landscaping works including tree protection, tree removal and new tree planting; green roofs; boundary treatment; internal roads and footpaths; and electrical services.
This analysis is carried out based on the drawings of Reddy Architecture and Urbanism.
1.1 Executive SummaryThe report assesses the impact of the proposed development for Daylight and Sunlight on the neighbouring buildings and the quality of daylight and sunlight to within the proposed development.
Impact on adjacent propertiesThere will be minimal impact to the daylight and sunlight to the adjacent dwellings with no perceivable reduction in either daylight or sunlight. There will be a minimal reduction in the sunlight to any of the adjacent amenity spaces. All areas assessed continue to meet or exceed the recommendations of the BRE guidelines.
Assessment of the quality of the proposed development.All the proposed units within the development will exceed the recommendations of the BRE guidelines for quality of Daylight with the apartments layouts which have been optimised for daylight and sunlight. The proposed amenity spaces will be bright well sunlit places and exceed the recommendations of the BRE guidelines.
Overall the results find that any impact on the adjacent residential structures would be minimal and imperceivable. There would be a good quality of daylight in the apartments analysed and the amenity areas would have sufficient sunlight to be bright and a pleasant spaces. The proposed development meets the recommendations of the BRE guidelines.
2: Methodology
2.1 Notes on the use of BS 8026-2 2008 and BRE guidance document (2011) Site layout planning for daylight and sunlight.Sustainable Urban Housing: Design Standards for New Apartments, Guidelines for Planning Authorities 2020 directs Planning authorities to have regard to quantitative performance approaches to daylight provision outlined in guides like the BRE guide ‘Site Layout Planning for Daylight and Sunlight’ (2nd edition) or British Standard BS 8206-2: 2008 – ‘Lighting for Buildings – Part 2: Code of Practice for Daylighting’. The standards for daylight and sunlight access in buildings (and the methodologies for assessment of same) suggested in both of these documents have been referenced in this Sunlight and Daylight Access Analysis. Neither the British Standard nor the BRE Guide set out rigid standards or limits. The BRE Guide is preceded by the following very clear warning as to how the design advice contained therein should be used: “The advice given here is not mandatory and the guide should not be seen as an instrument of planning policy; its aims is to help rather than constrain the designer. Although it gives numerical guidelines, these should be interpreted flexibly since natural lighting is only one of many factors in site layout design.” That the recommendations of the BRE Guide are not suitable for rigid application to all developments in all contexts is of particular importance in the context of national and local policies for the consolidation and densification of urban areas.
2.2 Daylight to the existing dwellingsThe site is analysed in plan, section and building use. Windows and amenity area are selected to test for impact from the proposed development.
BRE guidelines recommend that: “Loss of light to existing windows need not be assessed if the distance of each part of the new development from the existing window is three or more times its height above the centre of the existing window.”To check for this if part of a new building measured in a vertical section perpendicular to the main window wall of an existing building, from the centre of the lowest window, subtends an angle of more than 25º to the horizontal, then the diffuse light of the existing building may be adversely affected. If a window falls within a 45° angle both in plan and elevation with a new development in place then the window may be affected and should be assessed.
DRAFT
4
For loss of daylight and sunlight to existing buildings BRE guidance document (2011) “Site layout planning for daylight and sunlight” is used and BS8206 Part 2:2008 Lighting for Buildings, Code of Practice for Daylighting.
For loss of light the report recommends calculation of the Vertical Sky Component. This is the ratio of direct sky illuminance falling on the outside window, to the simultaneous horizontal illuminance under an unobstructed sky. The standard CIE Overcast Sky is used and the ratio is usually expressed as a percentage. The maximum value is just under 40% for a completely unobstructed vertical wall. The Vertical Sky Component on a window is a good measure of the amount of daylight entering it.
The BRE guidelines set out a two stage assessment for the Vertical Sky Component: a) Where the Vertical Sky Component at the centre of the existing window exceeds 27% with the new development in place then enough sky light should still be reached by the existing window.
b) Where the Vertical Sky Component with the new development in place is both less than 27% and less than 0.8 times its former value, then the area lit by the window is likely to appear more gloomy, and electric light will be needed more of the time.
2.3 SunlightThe BRE guidelines recommend assessing the loss of sunlight to the main living rooms and conservatories if they have a window wall facing within 90° of due south. Kitchens and bedrooms are less important but care should be taken not to block too much sun. If the proposed development is fully north then sunlight need not be assessed.
The Annual Probable Sunlight Hours (APSH) is used to assess the quantity of sunlight for a given location. This is the total amount sunshine for a given location on an unobstructed horizontal surface taking cloud cover into account. To Assess the APSH and the Probable Sunlight Hours for winter statistical data from the Irish Meteorological Service is used. Table 1 shows the average sunlight hours for each month and the maximum possible without any cloud cover. This gives the factor of possible sunlight hours for each month.
Met Eireann Sunlight Hours Data Set 1981-2010Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Total
Average Sunlight Hours/ Day 1:54 2:45 3:36 5:32 6:44 6:40 5:17 5:13 4:16 3:17 2:10 1:44Average Sunlight Hours/ Month 58:54 77:00 111:36 166:00 208:44 200:00 163:47 161:43 128:00 101:47 65:00 53:44 1496.25Total Available Sunlight Hours 252 265 358 412 488 485 496 451 375 320 250 248 4383Probable Sunlight Hours Ratio 23.37% 29.06% 31.17% 40.29% 42.77% 41.24% 33.02% 35.86% 34.13% 31.81% 26.00% 21.67% 34.14%
Table 1: Average monthly sunlight hours recorded at Dublin Airport - Data set 1981-2010
The BRE guidelines recommend that the centre of a window or 1.6m above ground for a door be assessed and receive at least 25% of the APSH and at least 5% during the period of 21st September to 21st March. If the available APSH is less than this then it should not be reduced below 0.8 times its former value or noticeable loss of sunlight may occur.
2.4 Sunlight to gardens and open spacesFor calculations of sunlight analysis it is general practice to use March 21 and the recommendations of the BRE guidance document (2011) “Site layout planning for daylight and sunlight”. P.J Littlefair, in relation to Gardens and open spaces section 3.3.17 state:
“It is recommended that for it to appear adequately sunlit throughout the year, at least half of a garden or amenity area should receive at least two hours of sunlight on 21 March. If as a result of new development an existing garden or amenity area does not meet the above, and the area which can receive two hours of sun on 21 March is less than 0.8 times its former value, then the loss of sunlight is likely to be noticeable. If a detailed calculation cannot be carried out, it is recommended that the centre of the area should receive at least two hours of sunlight on 21 March.”
2.5 Daylight in the proposed development. The proposed project is analysed in plan & section, and building use. The rooms are assessed for Average Daylight Factor (ADF).
DRAFT
5
2.6 Environmental impact assessmentThe BRE guidelines sets out criteria for classification for assessment of impact where a new development affects a number of existing buildings or open spaces. The guide does not give a specific range or percentages but sets out parameters set out below.
“Where the loss of skylight or sunlight fully meets the guidelines in this book, the impact is assessed as negligible or minor adverse. Where the loss of light is well within the guidelines, or only a small number of windows or limited area of open space lose light (within the guidelines), a classification of negligible impact is more appropriate. Where the loss of light is only just within the guidelines, and a larger number of windows or open space area are affected, a minor adverse impact would be more appropriate, especially if there is a particularly strong requirement for daylight and sunlight in the affected building or open space.
Where the loss of skylight or sunlight does not meet the guidelines in this book, the impact is assessed as minor, moderate or major adverse. Factors tending towards a minor adverse impact include: • only a small number of windows or limited area of open space are affected • the loss of light is only marginally outside the guidelines • an affected room has other sources of skylight or sunlight • the affected building or open space only has a low level requirement for skylight or sunlight • there are particular reasons why an alternative, less stringent, guideline should be applied.
Factors tending towards a major adverse impact include: • a large number of windows or large area of open space are affected • the loss of light is substantially outside the guidelines • all the windows in a particular property are affected • the affected indoor or outdoor spaces have a particularly strong requirement for skylight or sunlight, eg a living room in a dwelling or a children’s playground.
Beneficial impacts occur when there is a significant increase in the amount of skylight and sunlight reaching an existing building where it is required, or in the amount of sunlight reaching an open space.
Beneficial impacts should be worked out using the same principles as adverse impacts. Thus a tiny increase in light would be classified as a negligible impact, not a minor beneficial impact.”
A flexible approach should be taken when assessing the impact with daylight and sunlight being one of many factors that influence the environment when planning a new development.
DRAFT
6
Figure 1: Existing Site Plan.
3: Daylight to adjacent buildings.
Buildings to be demolished
68
3014
Churchfields
ChurchfieldsD
undr
um R
d
44
1
2
Emmet House
The site contains former institutional buildings of 1-3 Storeys, most of which are to be demolished. The protected structure, Emmet House and the adjoining single storey building to the rear, will be retained. Churchfields housing estate surrounds the site to the North and East. There are sports grounds to the South and the Dundrum road to the West with houses facing the site.
67
Figure 2: Aerial view of site.
O/H C
ABLE
O/H
CABLE
O/H CABLE
O/H CABLE O/H
CABLE
PEDESTRIAN CROSSING
KER
B KER
B
KER
B
GATE
GATE
KERB
KERB
Conc.
TARMAC
TARMAC WALKWAY
GATE
UP
WALLWALL
KERB
KERB
GAT
E
UP
Conc. STAIRS
Conc.
TARMAC
TARMAC
GRASS AREA
TARMAC
PALISADE FEN
CE
SOLID
BAR R
AILING
SOLID BAR RAILING
BOW RAILING
BOW RAILING
BOW RAILING
GATE
BOW RAILING
P&W FENCE
STEEL POST FENCE
KERB
KERB
BOW RAILING
BOW
RAILING
KERB
GATE
TARMAC WALKW
AY
TARMAC
TARMAC
TARMAC
TARMAC
TARMAC
TARMAC
TARMAC DRIVEWAY
Conc. PATH
Conc. PATH
TARM
AC PATH
GRASS AREA
GRASS AREA
GRASS AREA
GRASS AREA
GRASS AREA
GRASS AREA
KERB
KERB
KERB
KERB
KERB
KERB
GATEGATESTEEL FENCE
KERB
UP
UP
KERB
KERB
STEEL POST & WIRE FENCE
STEEL POST & WIRE FENCE
Conc. DRAINAGE CHANNEL
Conc. ED
GE
Conc. ED
GE
Conc.
Conc.
Conc.
STONE WALL
STONE WALL
STONE WALL
STONE WALLSTONE WALL
BLOCK WALL
BLOCK WALL
GAT
E
Conc. PATH
Conc. PATHBLOCK WALL
TREE OUTLINEC TREE TRUNKSL
POST BOX
GATE
GATE
BLOCK WALL
WALL
WALL
HEDGE
HED
GE
GROTTO
EDG
E O
F TA
RM
AC
EDGE O
F TARMAC
EDGE O
F TARMAC
STON
E WALL
STON
E WALL
STON
E WALL
STON
E WALL
KERB
Conc. FO
OTPATH
Conc. FO
OTPATH
Conc. FO
OTPATH
Conc. FO
OTPATH
KERB
KERB
KERB
KERBKER
B
CHAPEL
BLOCK EDGE
SHED
SHED
SHED SHED
PAVING
Conc. EDGE
Conc. EDGE
Conc. EDGE
Conc. EDGE
Ridge 46.54
Ridge 43.20
RL:34.63
Parapet 36.02
Parapet 40.71
Gutter 43.27
Gutter 40.59
Parapet 36.01
Parapet 39.94
Parapet 39.53
RL:42.86
Gutter 42.72
Parapet 41.32
Gutter 39.67
Parapet 41.31
Ridge 36.97
Gutter 34.17
FL 31.83
Gutter 35.50
Ridge 39.16
Gutter 36.32
Gutter 34.02Gutter 33.94
RL:34.25
RL:34.71
FL:31.41
Parapet 39.48
Gutter 42.73
Gutter 43.25
Parapet 35.75RL:34.52
RL:35.01
Gutter 33.57Gutter 33.81
RL:34.60
RL:35.29
RL:34.07
wt:34.50
wt:34.56
wt:34.64
wt:34.49
wt:32.92
wt:32.65
Top of Pier 33.24
Top of Pier 33.27
Top of Pier 33.24
Top of Pier 33.23
wt:32.91
wt:32.97
wt:33.34
Top of Pier 34.64
wt:33.25
wt:33.68
wt:33.89
wt:34.35
wt:34.27
Parapet 39.48
Parapet 39.49
Parapet 39.49
Gutter 36.32
wt:34.06
Gutter 40.59
Parapet 39.48
Parapet 39.48
Parapet 41.32
Parapet 39.49
EmmetHouse
CUS Grounds
PRO
DU
CED
BY
AN
AU
TOD
ESK
STU
DEN
T VE
RSI
ON
PRODUCED BY AN AUTODESK STUDENT VERSION
PRO
DU
CED
BY A
N A
UTO
DESK
STUD
ENT VER
SION
PRODUCED BY AN AUTODESK STUDENT VERSION
N
DRAFT
7
Figure 3: Proposed site plan showing the zone of influence and sections through window wall of adjacent residential properties.
Entrance
Emmet House and immediate
surrounds excluded from property
the subject of this application
Villa C
Villa B
Villa A
CUS Grounds
Green and woodland Area
Hawthorn Meadows
Gym
Concierge
E
D
C
B
A
F
G
H
30
28
44
67
68
30
29
Chandos
29
27262524232221
20191817161514
Coolnahinch
1
2
St. Luke's Crescent
Churchfields
N
Villa A Villa B
Villa E
Villa CVilla D
3.1 Preliminary assessment of adjoining dwellings The BRE guideline recommends that loss of light to existing windows need not be assessed if the distance of each part of the new development from the existing window is three or more times its height above the centre of the existing window. The zone of influence 3 times the height of the proposal is plotted in Figure 3 in yellow.
Section planes perpendicular to the window wall of the properties facing the proposed development are indicated in blue. The planes at locations A-H extend and intersect the proposed development. Sections at these locations are plotted in Figures 4 & 5.
The document also states that if part of a new building measured in a vertical section perpendicular to the main window wall of an existing building, from the centre of the lowest window, subtends an angle of more than 25º to the horizontal, then the diffuse light of the existing building may be adversely affected. If a window falls within a 45° angle both in plan and elevation with a new development in place then the window may be affected and should be assessed.
DRAFT
8
25o
25o
25o
Section through window wall at location H
Bo
un
da
ry
Section through window wall at location C
25o
25o
25o
25o
Bo
un
da
ry
Bo
un
da
ryB
ou
nd
ary
Bo
un
da
ry
Bo
un
da
ry
Bo
un
da
ry
Section through window wall at location G
Section through window wall at location F
Section through window wall at location E
Section through window wall at location B
Section through window wall at location D
Section through window wall at location A
25o
Bo
un
da
ry
Figure 4: Sections through the window wall of the adjacent residential properties.
Villa B
Villa A
Villa C
Villa D
68 Churchfields
67 Churchfields
27 Churchfields
21 Churchfields
Villa B
15 Churchfields
Emmet House
DRAFT
9
25o
25o
25o
Section through window wall at location H
Bo
un
da
ry
Section through window wall at location C
25o
25o
25o
25o
Bo
un
da
ry
Bo
un
da
ryB
ou
nd
ary
Bo
un
da
ry
Bo
un
da
ry
Bo
un
da
ry
Section through window wall at location G
Section through window wall at location F
Section through window wall at location E
Section through window wall at location B
Section through window wall at location D
Section through window wall at location A
25o
Bo
un
da
ry
Figure 5: Sections through the window wall of the adjacent residential properties.
Villa DVilla E
Chandos, Dundrum Rd
1 Coolnahinch, Dundrum Rd
3.2 DiscussionLocations A, B C and D: The 25º line would be subtended by the proposed development, indicating further assessment required.
Locations E, F and G: The 25º line is not subtended by the proposed development, indicating any reduction in available daylight is negligible and no further assessment required.
Location H: The 25º line would be subtended by the proposed development, indicating further assessment required.
3.3 ConclusionThe houses at Churchfields and Coolnahinch require further detailed assessment. For completeness all the houses adjacent to the proposed development within the zone of influence will be assessed in detail for the Vertical Sky Component (VSC) as recommended in the BRE guidelines.
30 St. Lukes Crescent
Villa DVilla E
DRAFT
10
Figure 6: No.68 Churchfields - indicating VSC and APSH test points.
4: Detailed assessment to adjoining dwellings
Following the preliminary analysis the windows in No.s 14 - 30 Churchfields, No.s 44, 67 & 68 Churchfields, No.s 29 & 30 St. Lukes Crescent, Chandos and No.s 1 & 2 Coolnahinch, Dundrum Road were assessed for their Vertical Sky Component (VSC). The BRE guidelines recommends assessing adjacent dwellings for the Vertical Sky Component where there is a potential loss of daylight identified in the preliminary assessment. The BRE guideline recommends that if a window retains a VSC in excess of 27% with the proposed development in place then it will still receive enough daylight. If the existing VSC is below 27% or is reduced below 27% and below 0.8 times its former value then the diffuse light maybe adversely affected.
Test points representing window in the dwellings at locations identified in Section 3.3 are indicated in Figures 6 - 12. The BRE guidelines recommend assessing the Vertical Sky Component (VSC) to adjacent properties, where the preliminary assessment indicates a further assessment is required. The Annual Probable Sunlight Hours will also be assessed.
Window locations are represented as accurately as possible and are determined based on available information from Architectural and survey drawings, Local authority planning records, Google earth and on site observation. Access to private rear gardens was not possible and any omissions or inaccurate window locations are unintentional.
68 68
Vertical Sky ComponentLocation Use/ Assumed
UseVertical Sky Component Recommended Value > 27%
Ratio: Proposal to Existing Recommended > 80%
Meets criteria of >27% VSC Or <27% but >80% Existing ValueExisting % Proposed %
68 Churchfields
1 Living room 29.2 28.1 96.4% Meets criteria
2 Family room 34.9 32.7 93.9% Average84.8%
*Dual AspectMeets criteria3 Family room 30.9 21.0 68.2%
4 Kitchen/ Dining 30.2 27.9 92.4% Average93.5%
*Dual AspectMeets criteria6 Kitchen/ Dining 34.7 32.8 94.6%
7 Bedroom 35.7 35.2 98.4% Meets criteria
8 Bedroom 38.2 36.8 96.5% Meets criteria
9 Bedroom 32.0 29.3 91.6% Average77.9%
**Dual AspectMeets criteria10 Bedroom 36.2 23.2 64.2%
11 Bedroom 35.8 33.9 94.7% Meets criteria
12 Bedroom 36.0 34.3 95.4% Meets criteria
* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Windows that retain a VSC in excess of 27% will not perceive a reduction in daylight availability.
Table 2: Vertical sky component for windows adjacent residential properties
DRAFT
11
Figure 8: No.67 Churchfields - Indicating VSC and APSH test points.
6767
67 Garden Space
Vertical Sky ComponentLocation Use/ Assumed Use Vertical Sky Component Recommended
Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria if >27% VSC or <27% but >80% Existing ValueExisting % Proposed %
67 Churchfields
13 Kitchen 34.8 32.1 92.4% Meets criteria
14 Study 30.2 30.0 99.2% Meets criteria
15 Family room 33.3 31.7 95.1% Meets criteria
16 Living room 35.7 34.7 97.1% Meets criteria
17 Bedroom 37.7 34.9 92.6% Meets criteria
18 Bedroom 37.7 34.6 91.6% Meets criteria
19 Bathroom 36.0 32.3 89.7% Meets criteria
20 Landing 36.7 25.5 69.5% Meets criteria
21 Bedroom 35.4 33.8 95.6% Meets criteria
22 Bedroom 36.0 34.9 96.8% Meets criteria
23 Bedroom 37.0 36.1 97.5% Meets criteria
130 Garden Room 27.0 25.2 93.3% Average87.3%
Meets criteria
131 Garden Room 31.1 25.5 81.2% Meets criteria
44 Churchfields
24 Living room 35.5 32.8 92.4% Meets criteria
25 Family room 31.9 28.7 89.8% Meets criteria
26 Family room 31.2 29.1 93.3% Meets criteria
27 Bedroom 36.8 34.0 92.4% Meets criteria
28 Bedroom 36.9 34.3 93.2% Meets criteria
44
Figure 7: No.67 Churchfields - Indicating VSC and APSH test points.
* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Windows that retain a VSC in excess of 27% will not perceive a reduction in daylight availability.
Table 3: Vertical sky component for windows adjacent residential properties
DRAFT
12
No. 30
Figure 9: No.s 25 - 30 Churchfields - Rear view of model, locating VSC and APSH test points.
No. 29
No. 28No. 27
No. 25 No. 26
Vertical Sky ComponentLocation Use/ Assumed Use Vertical Sky Component Recommended
Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria if >27% VSC or <27% but >80% Existing ValueExisting % Proposed %
No.s 29 & 30 Churchfields
29 Living room 30.6 27.9 91.2% Meets criteria
30 Kitchen 31.9 28.0 88.0% Meets criteria
31 Bedroom 36.1 33.0 91.3% Meets criteria
32 Bedroom 35.9 32.4 90.4% Meets criteria
33 Kitchen 32.3 28.0 86.7% Meets criteria
34 Dining 26.5 22.9 86.6% Meets criteria
35 Bedroom 36.1 32.3 89.6% Meets criteria
36 Bedroom 36.0 31.7 88.1% Meets criteria
No.s 25 - 28 Churchfields
37 Living room 29.2 24.7 84.5% Meets criteria
38 Kitchen 28.4 23.0 81.0% Meets criteria
39 Bedroom 35.6 30.8 86.4% Meets criteria
40 Bedroom 35.5 30.6 86.1% Meets criteria
41 Kitchen 32.6 27.0 82.9% Meets criteria
42 Dining 25.3 21.8 86.2% Meets criteria
43 Bedroom 35.1 30.3 86.3% Meets criteria
44 Bedroom 35.3 30.8 87.2% Meets criteria
45 Dining 25.3 21.9 86.7% Meets criteria
46 Kitchen 32.6 27.5 84.5% Meets criteria
47 Bedroom 35.2 30.9 87.7% Meets criteria
48 Bedroom 34.8 30.4 87.6% Meets criteria
49 Kitchen 32.5 27.3 84.1% Meets criteria
50 Dining 28.2 24.3 86.1% Meets criteria
51 Bedroom 35.0 30.7 87.7% Meets criteria
52 Bedroom 34.9 30.6 87.6% Meets criteria
* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Windows that retain a VSC in excess of 27% will not perceive a reduction in daylight availability.
Table 4: Vertical sky component for windows adjacent residential properties
DRAFT
13
Figure 10: No.s 17- 24 Churchfields - Rear view of model, locating VSC and APSH test points.
No. 24No. 23
No. 22No. 21No. 18
No. 19
No. 17
No. 20
Vertical Sky ComponentLocation Use/ Assumed Use Vertical Sky Component Recommended
Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria if >27% VSC or <27% but >80% Existing ValueExisting % Proposed %
No.s 21 - 24 Churchfields
53 Dining 28.1 23.6 84.1% Meets criteria
54 Kitchen 32.1 26.5 82.5% Meets criteria
55 Bedroom 34.8 30.2 86.7% Meets criteria
56 Bedroom 34.6 29.9 86.5% Meets criteria
57 Kitchen 31.8 26.4 82.8% Meets criteria
58 Dining 24.4 20.8 85.1% Meets criteria
59 Bedroom 34.3 29.7 86.7% Meets criteria
60 Bedroom 34.3 29.8 86.9% Meets criteria
61 Dining 23.9 20.7 86.4% Meets criteria
62 Kitchen 31.4 26.2 83.5% Meets criteria
63 Bedroom 34.2 29.9 87.3% Meets criteria
64 Bedroom 33.9 29.8 87.8% Meets criteria
65 Kitchen 31.1 26.3 84.7% Meets criteria
66 Dining 26.4 23.2 88.0% Meets criteria
67 Bedroom 34.0 30.1 88.5% Meets criteria
68 Bedroom 33.8 30.4 89.8% Meets criteria
No.s 17 - 20 Churchfields
69 Dining 26.8 24.0 89.5% Meets criteria
70 Kitchen 31.1 28.2 90.8% Meets criteria
71 Bedroom 34.1 31.6 92.7% Meets criteria
72 Bedroom 34.1 32.1 94.2% Meets criteria
73 Kitchen 30.9 28.8 93.2% Meets criteria
74 Dining 23.5 22.7 96.6% Meets criteria
75 Bedroom 33.9 32.5 95.8% Meets criteria
76 Bedroom 34.1 32.9 96.6% Meets criteria
77 Dining 23.7 23.0 97.0% Meets criteria
78 Kitchen 31.1 29.5 95.1% Meets criteria
79 Bedroom 34.2 33.1 97.0% Meets criteria
80 Bedroom 34.2 33.3 97.3% Meets criteria
81 Kitchen 31.3 30.2 96.5% Meets criteria
82 Dining 27.0 26.7 98.9% Meets criteria
83 Bedroom 34.4 33.6 97.7% Meets criteria
84 Bedroom 34.6 33.9 98.0% Meets criteria
* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Windows that retain a VSC in excess of 27% will not perceive a reduction in daylight availability.
Table 5: Vertical sky component for windows adjacent residential properties
DRAFT
14
No. 16
No. 14No. 15
Figure 11: No.s 14 - 16 Churchfields, No.s 29 & 30 St. Lukes Crescent - indicating VSC and APSH test points.
Vertical Sky ComponentLocation Use/ Assumed Use Vertical Sky Component Recommended
Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria if >27% VSC or <27% but >80% Existing ValueExisting % Proposed %
No.s 14 - 16 Churchfields
85 Living room 25.1 24.6 97.9% Meets criteria
86 Living room 29.3 28.6 97.7% Meets criteria
87 Living room 28.9 28.8 99.8% Meets criteria
88 Kitchen 27.2 26.6 98.1% Meets criteria
89 Bedroom 34.8 34.1 98.1% Meets criteria
90 Bedroom 34.7 34.1 98.3% Meets criteria
91 Kitchen 28.3 28.7 101.6% Meets criteria
92 Dining 28.3 28.0 99.0% Meets criteria
93 Bedroom 35.0 34.5 98.7% Meets criteria
94 Bedroom 34.8 34.8 99.8% Meets criteria
95 Kitchen 23.2 23.9 103.2% Meets criteria
96 Bedroom 33.9 35.2 103.7% Meets criteria
No.s 29 & 30 St. Lukes Crescent
97 Living room 37.2 33.1 89.0% Meets criteria
98 Bedroom 37.6 34.1 90.6% Meets criteria
99 Bedroom 37.8 34.1 90.2% Meets criteria
100 Living room 37.2 33.0 88.6% Meets criteria
101 Bedroom 37.8 34.0 89.9% Meets criteria
102 Bedroom 37.7 33.7 89.3% Meets criteria
No. 30 No. 29
No.s 29 & 30 St. Lukes CrescentNo.s 14 - 16 Churchfields
* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Windows that retain a VSC in excess of 27% will not perceive a reduction in daylight availability.
Table 6: Vertical sky component for windows adjacent residential properties
DRAFT
15
No. 2No. 1
Figure 12: Chandos, No.s 1 & 2 Coolnahinch -indicating VSC and APSH test points.
Chandos
Vertical Sky ComponentLocation Use/ Assumed Use Vertical Sky Component Recommended
Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria if >27% VSC or <27% but >80% Existing ValueExisting % Proposed %
Chanos, Dundrum Road
103 Living room 37.4 33.0 88.3% Meets criteria
104 Living room 37.6 33.5 88.9% Meets criteria
105 Living room 37.4 33.2 88.8% Meets criteria
106 Bedroom 38.0 34.5 90.8% Meets criteria
107 Bedroom 38.0 34.5 90.8% Meets criteria
108 Bedroom 37.8 34.6 91.3% Meets criteria
No.s 1 & 2 Coolnahinch
109 Living room 37.8 33.3 88.0% Meets criteria
110 Bedroom 38.0 34.2 90.0% Meets criteria
111 Bedroom 37.8 33.9 89.6% Meets criteria
112 Living room 37.8 33.5 88.5% Meets criteria
113 Bedroom 38.0 34.3 90.2% Meets criteria
114 Bedroom 37.9 34.2 90.4% Meets criteria* The guidelines recommends where a room has 2 or more windows the average all the windows should be used.** Window retains a VSC in excess of 27% and no reduction in daylight availability will be perceived.
Table 7: Vertical sky component for windows adjacent residential properties
4.1 DiscussionAll the windows to the adjoining dwellings facing the proposed development were tested in detail. There is a minor reduction to the available daylight to some of the windows but all the windows either retain a VSC in excess of 27% or are not reduced below 80% of their former value if less than 27% VSC. In the case of a dual aspect room, it is sufficient that if one window retains a VSC in excess of 27% there will be no perceived loss of light or the average of the number of windows retains a VSC in excess of 80% of the existing value.
The assessment of the VSC is a measurement at a point at the centre of each window to determine the portion of the sky visible to the point and window. The assessment does not take into account window size, room depth and the interior finishes to the room. Even if there is a reduction below the values set out in the BRE guidelines there may not be a noticeable reduction in available daylight.
4.2 ConclusionThe loss of light to all the windows assessed is well within the recommendations of the BRE guidelines and the proposed development meets the recommendations of the BRE Guidelines and BS8206 Part 2:2008 Lighting for Buildings Code of Practice for Daylighting. Any reduction to the daylight in neighbouring dwellings would be imperceptible and any impact will be negligible.
No.s 1 &2 Coolnahinch
DRAFT
16
Figure 13: View of Emmet House and of the model locating VSC test points.
4.3 Detailed assessment of Emmet House. Emmet House is a protected structure, 2 storeys over lower ground level and is currently in commercial use. The BRE guidelines does not set out specific requirement for daylight in rooms with commercial use. The windows that face the proposed development were assessed for impact on their VSC. Test points locations are indicated in Figure 13 and the results are displayed in Table 8 below.
Vertical Sky ComponentLocation Use Vertical Sky Component
Recommended Value > 27%Ratio: Proposal to Existing Recommended > 80%
Meets criteria of >27% VSC Or <27% but >80% Existing ValueExisting % Proposed %
115 Commercial 29.7 19.9 67.2% Minor impact
116 Commercial 27.4 19.8 72.4% Minor impact
117 Commercial 24.1 19.9 82.4% Meets criteria
118 Commercial 20.2 20.2 100.1% Meets criteria
119 Commercial 13.7 20.5 149.8% Meets criteria
120 Commercial 32.7 24.4 74.6% Minor impact
121 Commercial 30.9 24.4 78.9% Minor impact
122 Commercial 27.8 24.5 88.2% Meets criteria
123 Commercial 23.7 24.8 105.0% Meets criteria
124 Commercial 16.8 25.2 150.1% Meets criteria
125 Commercial 35.1 29.0 82.8% Meets criteria
126 Commercial 34.2 29.2 85.3% Meets criteria
127 Commercial 32.4 29.3 90.5% Meets criteria
128 Commercial 29.2 29.6 101.3% Meets criteria
129 Commercial 24.1 29.9 124.1% Meets criteria
Table 8: Vertical sky component for windows in Emmet House.
4.4 Discussion4 of the 15 windows are below 80% of their former value. Windows 115 and 116 most likely serve the same room and have a window facing away from the proposed development (as can be seen in figure 13) on a different elevation which would average at 80% of the existing VSC value for the cumulative of the 3 windows. The same applies to windows 120 and 121. Five of the windows would have an increase in available access to light from the sky.
4.5 ConclusionThe majority of windows meet the recommendations of the BRE guidelines. 4 of the windows are reduced below marginally below 80% of their existing value but there is an increase availability to 5 windows. The building meets the recommendations of the BRE guidelines and any impact will be negligible.
DRAFT
17
5: Sunlight in Adjoining Residential Living Areas
5.1 Annual Probable Sunlight HoursThe BRE guidelines recommends assessing window walls for the APSH that face within 90° of due South. The houses that this applies to are No.s 14 to 30, 44, 67 & 68 Churchfields. For a proposed development to have a noticeable impact on the annual Probable Sunlight Hours the value need to be reduced below the recommended 25% annual or 5% in the winter period from September to March. If the value is either below this to begin with or is reduced below this then it should not be reduced below 80% of its former value.
The guidelines states only the main living spaces need to be assessed. Bedrooms do not need to be assessed. The windows identified in the preliminary assessment and indicated in Figures 6-12 that face within 90° of due South are assessed and the results are set out in Table 9.
Annual Probable Sunlight HoursAPSH >25% Target Sept 21 - Mar 21 PSH >5% Target Meets criteria of
>25% APSH and >5% PSH Or
<25% or <5% PSH but >80% Existing Value
Location ID
Assumed room use
Existing Proposed Ratio Existing Proposed Ratio
% of APSH
% of APSH
If less than 25% APSH Target >80%
% PSH % PSH If less than 5% PSH Target >80%
68 Churchfields
1 Living room 71.0% 64.8% 91.3% 29.5% 26.1% 88.4% Yes
2 Family room 71.0% 59.9% 84.4% 29.3% 24.0% 81.9% Yes
3 Family room 46.3% 24.9% 53.7% 15.4% 9.3% 60.5% Yes
67 Churchfields
13 Kitchen 70.4% 61.3% 87.2% 23.6% 17.5% 74.3% Yes
14 Study 52.4% 52.4% 100.0% 10.7% 10.7% 100.0% Yes
44 Churchfields
24 Living room 75.7% 69.5% 91.8% 26.6% 21.6% 81.0% Yes
25 Family room 60.2% 52.5% 87.3% 23.5% 17.5% 74.6% Yes
26 Family room 36.1% 31.7% 87.8% 10.9% 7.2% 66.4% Yes
30 Churchfields
29 Living room 58.6% 53.9% 91.9% 14.4% 10.4% 72.7% Yes
30 Kitchen 60.2% 52.5% 87.2% 18.4% 11.9% 65.0% Yes
29 Churchfields
33 Kitchen 64.2% 55.9% 87.0% 18.4% 11.5% 62.4% Yes
34 Dining 50.2% 40.7% 81.0% 16.6% 8.7% 52.3% Yes
28 Churchfields
37 Living room 49.1% 44.1% 89.9% 9.8% 5.7% 57.8% Yes
38 Kitchen 53.2% 42.1% 79.2% 17.4% 8.2% 47.1% Yes
27 Churchfields
41 Kitchen 67.8% 56.3% 83.0% 21.3% 11.7% 55.0% Yes
42 Dining 42.9% 35.2% 82.1% 12.9% 6.5% 50.5% Yes
26 Churchfields
45 Dining 40.2% 33.2% 82.6% 12.4% 6.6% 53.1% Yes
46 Kitchen 68.4% 57.7% 84.4% 21.4% 12.5% 58.6% Yes
25 Churchfields
49 Kitchen 69.0% 57.5% 83.2% 21.9% 12.2% 56.0% Yes
50 Dining 51.6% 42.8% 82.9% 16.9% 9.5% 56.5% Yes
24 Churchfields
53 Dining 54.7% 45.4% 83.0% 16.3% 8.5% 52.6% Yes
54 Kitchen 63.6% 53.4% 83.9% 17.3% 8.8% 50.7% Yes
23 Churchfields
57 Kitchen 62.9% 53.0% 84.2% 17.5% 9.2% 52.8% Yes
58 Dining 44.2% 37.1% 83.8% 13.2% 7.3% 55.2% Yes
22 Churchfields
61 Dining 46.2% 38.9% 84.2% 11.8% 5.7% 48.4% Yes
DRAFT
18
Annual Probable Sunlight HoursAPSH >25% Target Sept 21 - Mar 21 PSH >5% Target Meets criteria of
>25% APSH and >5% PSH Or
<25% or <5% PSH but >80% Existing Value
Location ID
Assumed room use
Existing Proposed Ratio Existing Proposed Ratio
% of APSH
% of APSH
If less than 25% APSH Target >80%
% PSH % PSH If less than 5% PSH Target >80%
62 Kitchen 62.3% 52.6% 84.5% 16.1% 8.1% 50.3% Yes
21 Churchfields
65 Kitchen 60.9% 53.2% 87.3% 15.8% 9.4% 59.4% Yes
66 Dining 47.4% 43.1% 90.8% 13.5% 9.8% 73.0% Yes
20 Churchfields
69 Dining 41.3% 37.5% 90.7% 9.8% 6.6% 67.4% Yes
70 Kitchen 61.1% 56.4% 92.3% 15.1% 11.2% 74.0% Yes
19 Churchfields
73 Kitchen 60.5% 57.5% 95.2% 15.4% 13.0% 84.2% Yes
74 Dining 30.4% 29.8% 97.8% 6.9% 6.3% 92.0% Yes
18 Churchfields
77 Dining 28.0% 27.8% 99.3% 7.4% 7.2% 97.7% Yes
78 Kitchen 61.0% 58.3% 95.5% 15.0% 12.8% 85.0% Yes
17 Churchfields
81 Kitchen 61.1% 59.9% 98.0% 16.0% 14.9% 93.6% Yes
82 Dining 38.4% 38.2% 99.5% 10.2% 10.0% 98.3% Yes
16 Churchfields
85 Living room 35.5% 35.1% 98.9% 9.3% 8.9% 96.5% Yes
86 Living room 56.9% 55.7% 97.9% 12.6% 11.6% 92.0% Yes
87 Living room 48.2% 47.5% 98.5% 12.2% 11.6% 95.0% Yes
88 Kitchen 46.3% 45.4% 98.0% 10.5% 9.7% 92.8% Yes
15 Churchfields
91 Kitchen 49.9% 51.3% 102.8% 14.7% 15.9% 107.9% Yes
92 Dining 51.4% 50.5% 98.3% 11.5% 10.8% 93.6% Yes
14 Churchfields
95 Kitchen 40.6% 41.3% 101.6% 7.7% 8.3% 107.1% Yes
Table 9: Annual Probable Sunlight hours to adjoining properties
5.2 DiscussionNo.s 14 to 30, 44, 67 & 68 Churchfields are the relevant houses which have a living space with a window facing within 90° of due South. These were assessed and all windows have an APSH percentage greater than the recommended 25% (414 hours) and 5% (75 hours) from 21 September to 21 March.
In assessing the overall quality of light within a space it is important to note that sunlight is of lesser importance than good quality daylight. Direct sunlight is intermittent and a bright well lit living space is more desirable than a gloomy living space with spells of sunshine.
5.3 ConclusionAll windows assessed exceed the target values set out for annual and winter probable sunlight hours. The proposed development meets the recommendations of the BRE guidelines and any potential loss of sunlight will be negligible.
DRAFT
19
6: Daylight to Proposed Development.The BRE guidelines recommend that the Average Daylight Factor (ADF) be assessed in habitable rooms of new developments. BS 8206-2 gives minimum values of ADF of 2% for kitchens and living rooms which include a kitchen, 1.5% for living rooms and 1% for bedrooms. An average daylight factor of 5% is a well ‘daylit’ space. Where there are two room uses within a space then the higher ADF value should be used.
The factors that affect ADF are room depth, aspect, window size relative to floor area and closeness to an adjacent obstruction. All habitable rooms on the ground, first and the fourth floors were assessed. Results are shown for each block in table form together with false colour plans from generated analysis.
A01.01
A01.02
A02.02
A02.01
A02.03
A03.02
A03.01
A04.01
A04.02
A05.01
A05.02
A06.03
A06.02
A06.01
A07.01
A07.02
A08.01
A08.02
A09.02
A09.01
A10.02
A00.01
A10.01
Figure 14: Villa A False Colour Plan of ground & first floors indicating habitable rooms assessed for ADF
A11.01
A11.02
A12.02
A12.01
A12.03
A13.02
A13.01
A14.01
A14.02
A15.01
A15.02
A16.03
A16.02
A16.01
A17.01
A17.02
A18.01
A18.02
A19.02
A19.01
A20.03
A20.01
A15.03
A20.02
A17.03
Gro
und
Floo
rFi
rst F
loor
ADF
7%
0%
DRAFT
20
Average Daylight Factor - Villa ASpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
Ground Floor
A00.01 Concierge 85.9 207 8.82% N/A Meets Criteria
A01.01 Liv / Kit 24.1 66 2.40% 2 Meets Criteria
A01.02 Bed 10.0 30 3.48% 1 Meets Criteria
A02.01 Liv / Kit 29.6 78 2.55% 2 Meets Criteria
A02.02 Bed 10.1 30 6.43% 1 Meets Criteria
A02.03 Bed 13.9 35 2.84% 1 Meets Criteria
A03.01 Liv / Kit 26.3 59 3.62% 2 Meets Criteria
A03.02 Bed 11.5 35 4.59% 1 Meets Criteria
A04.01 Liv / Kit 23.5 54 2.91% 2 Meets Criteria
A04.02 Bed 9.9 30 4.28% 1 Meets Criteria
A05.01 Liv / Kit 21.2 62 2.62% 2 Meets Criteria
A05.02 Bed 9.9 30 1.67% 1 Meets Criteria
A06.01 Liv / Kit 30.4 75 4.73% 2 Meets Criteria
A06.02 Bed 13.3 36 2.80% 1 Meets Criteria
A06.03 Bed 9.9 25 1.46% 1 Meets Criteria
A07.01 Liv / Kit 21.2 62 4.53% 2 Meets Criteria
A07.02 Bed 11.5 35 4.80% 1 Meets Criteria
A08.01 Liv / Kit 21.2 62 4.42% 2 Meets Criteria
A08.02 Bed 11.5 35 4.63% 1 Meets Criteria
A09.01 Liv / Kit 21.2 62 4.70% 2 Meets Criteria
A09.02 Bed 11.5 35 4.63% 1 Meets Criteria
A10.01 Liv / Kit 21.3 62 8.88% 2 Meets Criteria
A10.02 Bed 11.5 35 4.98% 1 Meets Criteria
First Floor
A11.01 Liv / Kit 30.0 84 3.73% 2 Meets Criteria
A11.02 Bed 10.6 32 2.38% 1 Meets Criteria
A12.01 Liv / Kit 29.6 78 3.29% 2 Meets Criteria
A12.02 Bed 10.1 30 6.36% 1 Meets Criteria
A12.03 Bed 13.9 35 2.92% 1 Meets Criteria
A13.01 Liv / Kit 26.3 59 4.75% 2 Meets Criteria
A13.02 Bed 11.5 35 4.71% 1 Meets Criteria
A14.01 Liv / Kit 23.5 54 4.13% 2 Meets Criteria
A14.02 Bed 9.9 30 4.77% 1 Meets Criteria
A15.01 Liv / Kit 31.3 84 2.62% 2 Meets Criteria
A15.02 Bed 11.2 29 4.16% 1 Meets Criteria
A15.03 Bed 14.8 37 3.03% 1 Meets Criteria
A16.01 Liv / Kit 30.4 75 5.93% 2 Meets Criteria
A16.02 Bed 13.3 36 3.77% 1 Meets Criteria
A16.03 Bed 9.9 25 3.61% 1 Meets Criteria
A17.01 Liv / Kit 28.3 81 8.12% 2 Meets Criteria
A17.02 Bed 11.7 28 4.62% 1 Meets Criteria
A17.03 Bed 14.2 34 4.52% 1 Meets Criteria
A18.01 Liv / Kit 21.2 62 5.14% 2 Meets Criteria
A18.02 Bed 11.5 35 5.18% 1 Meets Criteria
A19.01 Liv / Kit 25.7 64 3.51% 2 Meets Criteria
A19.02 Bed 11.5 35 5.13% 1 Meets Criteria
A20.01 Liv / Kit 28.4 81 9.04% 2 Meets Criteria
A20.02 Bed 11.8 29 4.96% 1 Meets Criteria
A20.03 Bed 11.7 28 5.59% 1 Meets Criteria
Table 10: Villa A - Average Daylight Factor of Ground & First Floor Habitable Rooms
DRAFT
21
Figure 15: Villa B False Colour Plan of ground, first and fourth floors indicating habitable rooms assessed for ADF
ADF
7%
0%
B01.01
B01.02
B02.02
B03.02
B03.01
B04.01
B04.02
B05.03
B05.01
B06.02
B06.01
B07.01
B07.02
B08.02
B08.01
B01.03
B02.01
B03.03
B04.03
B05.02
B08.03
B09.01
B09.02
B10.02
B11.02
B11.01
B12.01
B12.02
B13.03
B13.01
B14.02
B14.01
B15.01
B15.02
B16.02
B16.01
B09.03
B10.01
B11.03
B12.03
B13.02
B16.03
Gro
und
Floo
r
B33.01
B34.02
B34.01
B35.03
B35.01
B36.02
B36.01
B37.01
B37.02
B33.02
B34.03
B35.02
B33.03
Four
th F
loor
Firs
t Flo
or
DRAFT
22
Average Daylight Factor - Villa BSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
Ground Floor
B01.01 Liv / Kit 28.3 81 5.80% 2 Meets Criteria
B01.02 Bed 11.7 28 4.70% 1 Meets Criteria
B01.03 Bed 11.8 29 4.23% 1 Meets Criteria
B02.01 Liv / Kit 21.2 62 2.49% 2 Meets Criteria
B02.02 Bed 10.6 32 4.19% 1 Meets Criteria
B03.01 Liv / Kit 31.3 84 2.24% 2 Meets Criteria
B03.02 Bed 11.2 29 4.19% 1 Meets Criteria
B03.03 Bed 14.8 37 3.54% 1 Meets Criteria
B04.01 Liv / Kit 30.4 75 3.34% 2 Meets Criteria
B04.02 Bed 13.5 38 2.55% 1 Meets Criteria
B04.03 Bed 11.7 23 4.70% 1 Meets Criteria
B05.01 Liv / Kit 30.2 75 4.28% 2 Meets Criteria
B05.02 Bed 13.3 32 3.02% 1 Meets Criteria
B05.03 Bed 11.7 23 3.06% 1 Meets Criteria
B06.01 Liv / Kit 21.2 62 2.34% 2 Meets Criteria
B06.02 Bed 10.5 32 3.15% 1 Meets Criteria
B07.01 Liv / Kit 21.1 62 2.23% 2 Meets Criteria
B07.02 Bed 10.6 32 3.14% 1 Meets Criteria
B08.01 Liv / Kit 28.3 81 4.44% 2 Meets Criteria
B08.02 Bed 11.8 29 2.54% 1 Meets Criteria
B08.03 Bed 11.7 28 4.65% 1 Meets Criteria
First Floor
B09.01 Liv / Kit 28.3 81 7.75% 2 Meets Criteria
B09.02 Bed 11.7 28 5.56% 1 Meets Criteria
B09.03 Bed 11.8 29 5.20% 1 Meets Criteria
B10.01 Liv / Kit 21.2 62 3.23% 2 Meets Criteria
B10.02 Bed 10.6 32 5.16% 1 Meets Criteria
B11.01 Liv / Kit 31.3 84 2.61% 2 Meets Criteria
B11.02 Bed 11.2 29 5.18% 1 Meets Criteria
B11.03 Bed 14.8 37 4.39% 1 Meets Criteria
B12.01 Liv / Kit 30.4 75 4.75% 2 Meets Criteria
B12.02 Bed 11.7 23 5.68% 1 Meets Criteria
B12.03 Bed 13.5 38 3.54% 1 Meets Criteria
B13.01 Liv / Kit 30.2 75 6.10% 2 Meets Criteria
B13.02 Bed 11.7 23 4.04% 1 Meets Criteria
B13.03 Bed 13.3 32 4.25% 1 Meets Criteria
B14.01 Liv / Kit 21.2 62 3.47% 2 Meets Criteria
B14.02 Bed 10.5 32 4.45% 1 Meets Criteria
B15.01 Liv / Kit 21.1 62 2.73% 2 Meets Criteria
B15.02 Bed 10.6 32 4.36% 1 Meets Criteria
B16.01 Liv / Kit 28.3 81 6.27% 2 Meets Criteria
B16.02 Bed 11.8 29 3.60% 1 Meets Criteria
B16.03 Bed 11.7 28 5.51% 1 Meets Criteria
Fourth Floor
B33.01 Liv / Kit 27.7 75 10.05% 2 Meets Criteria
B33.02 Bed 11.4 30 6.98% 1 Meets Criteria
B33.03 Bed 13.2 33 5.93% 1 Meets Criteria
B34.01 Liv / Kit 27.7 75 7.96% 2 Meets Criteria
B34.02 Bed 11.4 30 6.53% 1 Meets Criteria
DRAFT
23
Average Daylight Factor - Villa BSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
B34.03 Bed 13.2 33 5.78% 1 Meets Criteria
B35.01 Liv / Kit 30.2 75 9.39% 2 Meets Criteria
B35.02 Bed 11.7 23 5.78% 1 Meets Criteria
B35.03 Bed 13.3 32 5.21% 1 Meets Criteria
B36.01 Liv / Kit 21.2 62 6.36% 2 Meets Criteria
B36.02 Bed 10.5 32 5.93% 1 Meets Criteria
B37.01 Liv / Kit 21.1 62 5.86% 2 Meets Criteria
B37.02 Bed 10.6 32 5.92% 1 Meets Criteria
Table 11: Villa B - Average Daylight Factor of Ground, First & Fourth Floor Habitable Rooms
DRAFT
24
Figure 16: Villa C False Colour Plan of ground, first and fourth floors indicating habitable rooms assessed for ADF
C01.01
C01.02
C02.01
C03.01
C03.02
C04.01
C04.02
C05.03
C05.01
C06.03
C06.01
C06.02
C07.02
C07.01
C01.03
C02.02
C04.03
C05.02
C07.03
C08.01
C08.02
C09.01
C10.01
C10.02
C11.01
C11.02
C12.03
C12.01
C13.03
C13.01
C13.02
C14.02
C14.01
C08.03
C09.02
C11.03
C12.02
C14.03
C29.01
C29.02
C30.01
C31.01
C31.02
C32.01
C32.02
C33.03
C33.01
C34.03
C34.01
C34.02
C35.02
C35.01
C29.03
C30.02
C32.03
C33.02
C35.03
Gro
und
Floo
rFi
rst F
loor
ADF
7%
0%
Four
th F
loor
DRAFT
25
Average Daylight Factor - Villa CSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
Ground Floor
C01.01 Liv / Kit 28.3 81 5.73% 2 Meets Criteria
C01.02 Bed 11.7 28 2.01% 1 Meets Criteria
C01.03 Bed 9.6 24 4.98% 1 Meets Criteria
C02.01 Liv / Kit 19.6 52 2.33% 2 Meets Criteria
C02.02 Bed 10.4 32 4.62% 1 Meets Criteria
C03.01 Liv / Kit 19.3 46 2.69% 2 Meets Criteria
C03.02 Bed 10.8 32 4.67% 1 Meets Criteria
C04.01 Liv / Kit 30.7 75 7.37% 2 Meets Criteria
C04.02 Bed 13.7 38 4.46% 1 Meets Criteria
C04.03 Bed 11.7 23 5.04% 1 Meets Criteria
C05.01 Liv / Kit 30.2 75 7.06% 2 Meets Criteria
C05.02 Bed 13.3 32 3.17% 1 Meets Criteria
C05.03 Bed 11.7 23 5.65% 1 Meets Criteria
C06.01 Liv / Kit 23.2 64 3.06% 2 Meets Criteria
C06.02 Bed 11.2 29 3.53% 1 Meets Criteria
C06.03 Bed 14.6 37 3.11% 1 Meets Criteria
C07.01 Liv / Kit 28.3 81 5.67% 2 Meets Criteria
C07.02 Bed 9.6 24 4.27% 1 Meets Criteria
C07.03 Bed 11.7 28 1.85% 1 Meets Criteria
First Floor
C08.01 Liv / Kit 28.3 81 5.86% 2 Meets Criteria
C08.02 Bed 11.7 28 2.30% 1 Meets Criteria
C08.03 Bed 9.6 24 5.40% 1 Meets Criteria
C09.01 Liv / Kit 19.6 52 2.15% 2 Meets Criteria
C09.02 Bed 10.4 32 5.06% 1 Meets Criteria
C10.01 Liv / Kit 19.3 46 2.49% 2 Meets Criteria
C10.02 Bed 10.8 32 5.08% 1 Meets Criteria
C11.01 Liv / Kit 30.7 75 7.26% 2 Meets Criteria
C11.02 Bed 11.7 23 5.45% 1 Meets Criteria
C11.03 Bed 13.7 38 4.58% 1 Meets Criteria
C12.01 Liv / Kit 30.2 75 6.57% 2 Meets Criteria
C12.02 Bed 11.7 23 5.73% 1 Meets Criteria
C12.03 Bed 13.3 32 3.34% 1 Meets Criteria
C13.01 Liv / Kit 23.2 64 2.58% 2 Meets Criteria
C13.02 Bed 11.2 29 3.80% 1 Meets Criteria
C13.03 Bed 14.6 37 3.28% 1 Meets Criteria
C14.01 Liv / Kit 28.3 81 5.51% 2 Meets Criteria
C14.02 Bed 9.6 24 4.61% 1 Meets Criteria
C14.03 Bed 11.7 28 2.18% 1 Meets Criteria
Fourth Floor
C29.01 Liv / Kit 28.3 81 6.60% 2 Meets Criteria
C29.02 Bed 11.7 28 3.12% 1 Meets Criteria
C29.03 Bed 9.6 24 5.78% 1 Meets Criteria
C30.01 Liv / Kit 19.6 52 2.33% 2 Meets Criteria
C30.02 Bed 10.4 32 5.66% 1 Meets Criteria
C31.01 Liv / Kit 19.3 46 2.65% 2 Meets Criteria
C31.02 Bed 10.8 32 5.68% 1 Meets Criteria
C32.01 Liv / Kit 30.7 75 7.77% 2 Meets Criteria
C32.02 Bed 11.7 23 5.83% 1 Meets Criteria
C32.03 Bed 13.7 38 4.78% 1 Meets Criteria
C33.01 Liv / Kit 30.2 75 6.95% 2 Meets Criteria
DRAFT
26
Average Daylight Factor - Villa CSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
C33.02 Bed 11.7 23 5.84% 1 Meets Criteria
C33.03 Bed 13.3 32 3.98% 1 Meets Criteria
C34.01 Liv / Kit 23.2 64 3.23% 2 Meets Criteria
C34.02 Bed 11.2 29 4.54% 1 Meets Criteria
C34.03 Bed 14.6 37 3.85% 1 Meets Criteria
C35.01 Liv / Kit 28.3 81 6.53% 2 Meets Criteria
C35.02 Bed 9.6 24 5.32% 1 Meets Criteria
C35.03 Bed 11.7 28 2.99% 1 Meets Criteria
Table 12: Villa C - Average Daylight Factor of Ground & First Floor Habitable Rooms
D47.01
D47.02
D48.02
D51.03
D51.01
D53.01
D53.02
D54.02
D54.01
D47.03
D48.01
D51.02
D50.01
D50.02
D52.01
D52.02
D49.01
D49.02
D55.03
D55.01
D55.02
D00.04
Figure 17: Villa D False Colour Plan of 4th floor indicating habitable rooms assessed for ADF
Four
th F
loor
ADF
7%
0%
DRAFT
27
Figure 18: Villa D False Colour Plan of ground & 1st floors indicating habitable rooms assessed for ADF
D11.01
D11.02
D12.01
D14.01
D14.02
D15.01
D18.03
D18.01
D20.01
D20.02
D21.02
D21.01
D11.03
D12.02
D15.02
D18.02
D15.03
D16.01
D16.02
D17.01
D17.02
D17.02
D19.01
D19.02
D13.01
D13.02
D22.03
D22.01
D22.02
Firs
t Flo
or
D01.01
D01.02
D02.01
D03.01
D03.02
D04.01
D07.03
D07.01
D09.01
D09.02
D10.02
D10.01
D01.03
D02.02
D04.02
D07.02
D00.01
D04.03
D05.01
D05.02
D06.01
D06.02
D06.02
D10.03
D08.01
D08.02
Gro
und
Floo
r
ADF
7%
0%
DRAFT
28
Average Daylight Factor - Villa DSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
Ground Floor
D00.01 Gym 66.3 174 10.45% N/A Meets Criteria
D01.01 Liv / Kit 29.1 69 5.64% 2 Meets Criteria
D01.02 Bed 13.1 36 3.77% 1 Meets Criteria
D01.03 Liv / Kit 11.7 23 4.96% 2 Meets Criteria
D02.01 Liv / Kit 31.4 84 2.15% 2 Meets Criteria
D02.02 Bed 11.2 29 3.89% 1 Meets Criteria
D02.03 Bed 14.0 35 1.21% 1 Meets Criteria
D03.01 Liv / Kit 23.2 60 4.67% 2 Meets Criteria
D03.02 Bed 12.2 35 1.85% 1 Meets Criteria
D04.01 Liv / Kit 27.4 66 4.50% 2 Meets Criteria
D04.02 Bed 9.8 25 1.61% 1 Meets Criteria
D04.03 Bed 13.5 40 6.12% 1 Meets Criteria
D05.01 Liv / Kit 20.1 54 7.51% 2 Meets Criteria
D05.02 Bed 9.8 30 6.84% 1 Meets Criteria
D06.01 Liv / Kit 31.1 78 2.96% 2 Meets Criteria
D06.02 Bed 9.6 25 7.16% 1 Meets Criteria
D06.03 Bed 11.2 30 6.05% 1 Meets Criteria
D07.01 Liv / Kit 30.4 75 6.30% 2 Meets Criteria
D07.02 Bed 13.5 38 3.62% 1 Meets Criteria
D07.03 Bed 11.7 23 4.19% 1 Meets Criteria
D08.01 Liv / Kit 21.6 62 4.33% 2 Meets Criteria
D08.02 Bed 11.9 35 2.65% 1 Meets Criteria
D09.01 Liv / Kit 21.6 62 2.55% 2 Meets Criteria
D09.02 Bed 11.9 35 4.36% 1 Meets Criteria
D10.01 Liv / Kit 31.3 84 3.50% 2 Meets Criteria
D10.02 Bed 11.2 29 3.78% 1 Meets Criteria
D10.03 Bed 14.8 37 3.63% 1 Meets Criteria
First Floor
D11.01 Liv / Kit 30.3 75 6.24% 2 Meets Criteria
D11.02 Bed 13.5 38 4.18% 1 Meets Criteria
D11.03 Bed 11.7 23 4.62% 1 Meets Criteria
D12.01 Liv / Kit 21.6 62 2.36% 2 Meets Criteria
D12.02 Bed 11.9 35 2.94% 1 Meets Criteria
D13.01 Liv / Kit 21.6 62 2.71% 2 Meets Criteria
D13.02 Bed 11.9 35 2.59% 1 Meets Criteria
D14.01 Liv / Kit 26.9 64 4.12% 2 Meets Criteria
D14.02 Bed 12.2 35 2.14% 1 Meets Criteria
D15.01 Liv / Kit 27.4 66 4.54% 2 Meets Criteria
D15.02 Bed 10.6 27 1.59% 1 Meets Criteria
D15.03 Bed 13.5 40 6.34% 1 Meets Criteria
D16.01 Liv / Kit 20.1 54 5.55% 2 Meets Criteria
D16.02 Bed 9.8 30 6.24% 1 Meets Criteria
D17.01 Liv / Kit 31.1 78 3.08% 2 Meets Criteria
D17.02 Bed 9.6 25 6.42% 1 Meets Criteria
D17.03 Bed 11.2 30 5.59% 1 Meets Criteria
D18.01 Liv / Kit 30.4 75 6.50% 2 Meets Criteria
D18.02 Bed 13.5 38 3.71% 1 Meets Criteria
D18.02 Bed 11.7 23 4.74% 1 Meets Criteria
D19.01 Liv / Kit 21.6 62 3.52% 2 Meets Criteria
D19.02 Bed 11.9 35 4.14% 1 Meets Criteria
DRAFT
29
Average Daylight Factor - Villa DSpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
D20.01 Liv / Kit 21.6 62 4.04% 2 Meets Criteria
D20.02 Bed 11.9 35 4.56% 1 Meets Criteria
D21.01 Liv / Kit 21.6 62 4.53% 2 Meets Criteria
D21.02 Bed 11.9 35 4.91% 1 Meets Criteria
D22.01 Liv / Kit 30.3 75 7.06% 2 Meets Criteria
D22.02 Bed 11.7 23 8.85% 1 Meets Criteria
D22.03 Bed 13.5 38 4.33% 1 Meets Criteria
Fourth Floor
D04.00 Co working 105.5 280 17.14% N/A Meets Criteria
D47.01 Liv / Kit 30.3 75 9.56% 2 Meets Criteria
D47.02 Bed 13.5 38 5.11% 1 Meets Criteria
D47.03 Bed 11.7 23 5.77% 1 Meets Criteria
D48.01 Liv / Kit 21.6 62 3.99% 2 Meets Criteria
D48.02 Bed 11.9 35 4.81% 1 Meets Criteria
D49.01 Liv / Kit 21.6 62 4.54% 2 Meets Criteria
D49.02 Bed 11.9 35 4.83% 1 Meets Criteria
D50.01 Liv / Kit 27.1 64 4.27% 2 Meets Criteria
D50.02 Bed 10.6 32 6.13% 1 Meets Criteria
D51.01 Liv / Kit 30.4 75 7.07% 2 Meets Criteria
D51.02 Bed 11.7 23 4.84% 1 Meets Criteria
D51.03 Bed 13.5 38 4.65% 1 Meets Criteria
D52.01 Liv / Kit 21.6 62 4.77% 2 Meets Criteria
D52.02 Bed 11.9 35 5.42% 1 Meets Criteria
D53.01 Liv / Kit 21.6 62 4.98% 2 Meets Criteria
D53.02 Bed 11.9 35 5.66% 1 Meets Criteria
D54.01 Liv / Kit 21.6 62 6.06% 2 Meets Criteria
D54.02 Bed 11.9 35 6.65% 1 Meets Criteria
D55.01 Liv / Kit 30.3 75 9.84% 2 Meets Criteria
D55.02 Bed 11.7 23 10.02% 1 Meets Criteria
D55.03 Bed 13.5 38 5.19% 1 Meets Criteria
Table 13: Villa D - Average Daylight Factor of Ground, First & Fourth Floor Habitable Rooms
DRAFT
30
E01.01
E01.02
E02.01E02.02
E03.02 E03.01E04.01E05.01E05.02
E00.01
E02.03
E03.03
E04.02E06.01 E06.02
E06.03
E07.01
E07.02
E08.01E08.02
E09.02 E09.01E10.01E11.01E11.02
E08.03
E09.03
E10.02E12.01 E12.02
E12.03
E13.03E13.01
E13.02
E28.01E29.01E29.02 E28.02E30.01 E30.02
E30.03
E31.03E31.01
E31.02
Gro
und
Floo
rFi
rst F
loor
Four
th F
loor
Figure 19: Villa E False Colour Plan of ground, first and fourth floors indicating habitable rooms assessed for ADF
DRAFT
31
Average Daylight Factor - Villa ESpace ID Description Area m2 Sensor Count ADF Minimum ADF Comment
Ground Floor
E00.01 Cafe 69.8 176 9.42% N/A Meets Criteria
E01.01 Liv / Kit 20.1 55 6.93% 2 Meets Criteria
E01.02 Bed 11.5 35 4.95% 1 Meets Criteria
E02.01 Liv / Kit 31.4 75 3.01% 2 Meets Criteria
E02.02 Bed 14.4 38 4.43% 1 Meets Criteria
E02.03 Bed 11.5 23 1.47% 1 Meets Criteria
E03.01 Liv / Kit 30.4 75 3.85% 2 Meets Criteria
E03.02 Bed 11.5 23 1.57% 1 Meets Criteria
E03.03 Bed 12.8 38 5.33% 1 Meets Criteria
E04.01 Liv / Kit 21.2 62 3.37% 2 Meets Criteria
E04.02 Bed 11.5 35 4.92% 1 Meets Criteria
E05.01 Liv / Kit 21.2 62 3.34% 2 Meets Criteria
E05.02 Bed 11.5 35 4.86% 1 Meets Criteria
E06.01 Liv / Kit 30.3 75 6.96% 2 Meets Criteria
E06.02 Bed 13.4 38 4.98% 1 Meets Criteria
E06.03 Bed 11.7 23 5.39% 1 Meets Criteria
First Floor
E07.01 Liv / Kit 20.1 55 6.33% 2 Meets Criteria
E07.02 Bed 11.5 35 5.30% 1 Meets Criteria
E08.01 Liv / Kit 31.4 75 3.82% 2 Meets Criteria
E08.02 Bed 14.4 38 4.72% 1 Meets Criteria
E08.03 Bed 11.5 23 2.16% 1 Meets Criteria
E09.01 Liv / Kit 30.4 75 4.78% 2 Meets Criteria
E09.02 Bed 11.5 23 2.24% 1 Meets Criteria
E09.03 Bed 12.8 38 5.62% 1 Meets Criteria
E10.01 Liv / Kit 21.2 62 4.04% 2 Meets Criteria
E10.02 Bed 11.5 35 5.27% 1 Meets Criteria
E11.01 Liv / Kit 21.2 62 4.05% 2 Meets Criteria
E11.02 Bed 11.5 35 5.19% 1 Meets Criteria
E12.01 Liv / Kit 30.3 75 7.99% 2 Meets Criteria
E12.02 Bed 13.4 38 5.28% 1 Meets Criteria
E12.03 Bed 11.7 23 6.15% 1 Meets Criteria
E13.01 Liv / Kit 30.3 75 8.56% 2 Meets Criteria
E13.02 Bed 13.4 38 5.70% 1 Meets Criteria
E13.03 Bed 11.7 23 5.90% 1 Meets Criteria
Fourth Floor
E28.01 Liv / Kit 21.2 62 4.14% 2 Meets Criteria
E28.02 Bed 11.5 35 5.46% 1 Meets Criteria
E29.01 Bed 21.2 62 4.11% 1 Meets Criteria
E29.02 Bed 11.5 35 5.41% 1 Meets Criteria
E30.01 Liv / Kit 30.3 75 8.26% 2 Meets Criteria
E30.02 Bed 13.4 38 5.42% 1 Meets Criteria
E30.03 Bed 11.7 23 6.34% 1 Meets Criteria
E31.01 Liv / Kit 30.3 75 10.40% 2 Meets Criteria
E31.02 Bed 13.4 38 5.46% 1 Meets Criteria
E31.03 Bed 11.7 23 6.52% 1 Meets Criteria
Table 14: Villa E - Average Daylight Factor of Ground, First & Fourth Floor Habitable Rooms
DRAFT
32
6.1 DiscussionWithin the development the design was optimised for good quality daylight. Priority is given to main living spaces over bedrooms and where possible they are positioned away from inner corners or projecting stair cores to maximise available daylight. The use of very large windows also enhances available daylight and light penetration to the depths of the rooms.
The higher target value of 2% is selected for all the main living rooms because they contain a kitchen and the BRE guide and BS 8602:2 recommend that the higher value should be used were there are multiple uses in a room. The assessment plane covers 100% of living space being considered and in some cases excludes the circulation space from the apartment entrance to the main living space. The corridors associated with the living space would be traditionally be internalised and are deep within the plan where natural light levels will not penetrate and artificial lighting will be required. The assessment plane in these rooms still exceed 80% of the floor plate.
All habitable rooms on the ground, first and fourth floors were assessed. Its is evident from the results that the ADF values improve with the higher the floor level. This is due to increased access to the sky with less obstruction from opposing buildings. All the rooms assessed exceed the minimum ADF levels with a large number of the rooms exceeding an ADF of 5%, this is particularly evident in the rooms with dual aspect.
6.2 ConclusionAll the rooms assessed exceed the minimum recommendations for the Average Daylight Factor and will be well daylit. The proposed development meets the recommendations of the BRE Guidelines and BS8206 Part 2:2008 Lighting for Buildings, Code of Practice for Daylighting.
DRAFT
33
The BRE document indicates that for an amenity area, such as a garden, to have good quality sunlight throughout the year, 50% should receive in excess of 2 hours sunlight on the 21st March. It also states that front gardens need not be assessed for sunlight.
The guidelines states that the 21 March should be used for the assessment and that “Sunlight at an altitude of 10° or less does not count, because it is likely to be blocked by low level planting anyway.” The amenity space is assessed for the amount of direct sunlight received by the space in 5 minute intervals between 8am and 6pm on the 21st March over an analysis grid with a 300mm grid size and the average is calculated.
7.1 Private amenity space to neighbouring properties.No.s 14 - 30 Churchfields are to the North of the Proposed Development, No.s 67 & 68 are to the East. The private amenity space to the neighbouring properties which is generally the rear garden were assessed for the availability of sunlight on the ground. The existing and proposed radiation maps are in Figures 20 - 22, the results can be seen in Table 15 below.
Sunlight on the Ground - Adjacent ResidencesLocation ID Location Existing Proposed Ratio Meets criteria of
>50% area Or if <50% but >80% Existing Value
% Area receiving 2 hours sunlight on 21st March
L1 Churchfields 14 83.8 83.8 100.0% Meets criteria
L2 Churchfields 15 79.7 79.7 100% Meets criteria
L3 Churchfields 16 71.0 76.7 108% Meets criteria
L4 Churchfields 17 56 74.5 133% Meets criteria
L5 Churchfields 18 54.3 73 134% Meets criteria
L6 Churchfields 19 54.8 70 127.7% Meets criteria
L7 Churchfields 20 57.7 72.7 126.0% Meets criteria
L8 Churchfields 21 64.9 67.4 103.9% Meets criteria
L9 Churchfields 22 67.5 66.2 98.1% Meets criteria
L10 Churchfields 23 69.0 68.6 99.4% Meets criteria
L11 Churchfields 24 70.5 70.5 100.0% Meets criteria
L12 Churchfields 25 73.3 73.3 100.0% Meets criteria
L13 Churchfields 26 71.3 69.8 97.9% Meets criteria
L14 Churchfields 27 72.5 68.6 94.6% Meets criteria
L15 Churchfields 28 43.9 44.3 100.9% Meets criteria
L16 Churchfields 29 57.2 56.4 98.6% Meets criteria
L17 Churchfields 30 47.2 46.9 99.4% Meets criteria
L18 Churchfields 67 77.6 76.0 97.9% Meets criteria
L19 Churchfields 68 78.2 66.5 85.0% Meets criteria
Table 15: Calculation of Sun on the Ground to Adjacent Amenity Spaces.
7.2 DiscussionThe adjacent residential properties which have private amenity spaces (rear gardens) facing toward the proposed development are all in Churchfields. There is a marginal reduction to the percentage of the amenity spaces receiving at least 2 hours sunlight to some of the gardens but this is not reduced to 80% of their former value set out in the BRE guidelines. There is a positive impact to some of the gardens from 15 to 21 Churchfields where the removal of the boundary structures will allow increased availability of access to the sun.
The CUS grounds are entirely to the south of the proposed buildings and will not have any reduction in sunlight to the amenity space.
7.3 ConclusionA small number of gardens will have a small reduction to the percentage of the amenity spaces receiving at least 2 hours sunlight on the 21st March but none are reduced below 80% of their existing value. Additionally some amenity spaces will experience an increased availability. The proposed development meets the recommendations of the BRE guidelines.
7: Sunlight to gardens and open spaces
DRAFT
34
Figure 20: No.s 15 - 30 Churchfields: Existing radiation map generated through the calculation of sun on the ground, on the 21st March. Scale indicates 0-8 hours of sunlight.
Figure 21: No.s 15 - 30 Churchfields: Proposed radiation map generated through the calculation of sun on the ground, on the 21st March. Scale indicates 0-8 hours of sunlight.
N
N Existing
Proposed
30
28
29
272625
Churchfields
44
67
68
2423222120191817
161514
30
28
29
272625
Churchfields
44
67
68
2423222120191817
161514
DRAFT
35
N
Figure 22: No.s 67 & 68 Churchfields: Existing & Proposed radiation maps generated through the calculation of sun on the ground, on the 21st March. Scale indicates 0-8 hours of sunlight.
No. 67 No. 67
No. 68 No. 68
Existing Proposed
DRAFT
36
S2
7.4 Sunlight to amenity within the proposed development
The areas of amenity within this proposal have been assessed with a calculation of Sun on the Ground on the 21st March. A location plan is shown in Figure 23, generated analysis in Figure 24 and the results are set out in Table 16 below.
Sunlight on the ground - within developmentLocation ID Location Proposed Meets criteria if
>50% area receiving 2 hours sunlight on 21st March% Area receiving 2 hours sunlight on 21st March
S1 Ground level 88.4% Meets criteria
S2 Roof terrace, Villa D 92% Meets criteria
Table 16: Calculation of Sun on the Ground to amenity area within the proposed development.
Figure 23: Landscape plan, locating areas of amenity assessed for direct sunlight.
N
S1
DRAFT
37
S1
S2
Figure 24: Proposed Radiation map of amenity areas, showing available sunlight on 21st March. The scale represents the percentage of daylight received from 0 - 8 hours.
N
7.5 ConclusionA variety of amenity spaces have been designed into this scheme, they are well oriented for sunlight and over 88% of the proposed amenity spaces will have over 2 hours sunlight on the 21st March. The proposed development meets the recommendations of the BRE guidelines.
DRAFT
38
8: Shadow Diagrams
8.1 BRE Guidance on Shadow StudiesThe BRE guidelines recommend using the 21st March for plotting shadow, it states: “If a space is used all year round, the equinox (21 March) is the best date for which to prepare shadow plots as it gives an average level of shadowing. Lengths of shadows at the autumn equinox (21 September) will be the same as those for 21 March, so a separate set of plots for September is not required.”
June 21st and December 21st are provided below for information but it should be noted that the summer solstice is the best case scenario with shadows at their shortest. In Winter even low buildings will cast long shadows and it is common for large areas of the ground to be in shadow throughout the day especially in a built up area and sun barely rises above an altitude of 10° during the course of the day. The guidelines recommends that Sunlight at an altitude of 10° or less does not count. Below are the times for the Equinox and Solstice that the sun is above 10° altitude rounded to the nearest half hour.
Equinox: between 8:30 and 17:30Summer Solstice: Between 6:30 and 20:00Winter Solstice: Between 10:30 and 14:00
Section 8.3 shows the proposed shadow diagrams for the Equinox on the 21st March at 2 hourly intervals during the day between 09:00 and 17:00. Section 8.4 shows the proposed shadow diagrams for the Summer Solstice on the 21st June at 2 hourly intervals during the day between 10:00 and 18:00. Section 8.5 shows the proposed shadow diagrams for the Equinox on the 21st September at 2 hourly intervals during the day between 09:00 and 17:00. Section 8.6 shows the proposed shadow diagrams for the Winter Solstice on the 21st December at 2 hourly intervals during the day between 10:00 and 16:00.
The shadows cast on the September equinox are the same as the March Equinox. They are included here with the Daylight Saving Time (DST) applied, as with the Summer Solstice diagrams. Much of the site is a greenfield, where there is no shadows cast from any structures on the site at present.
The use of shadow diagrams as an assessment method should be taken over the course of the day and not a specific time due to the transient nature of the sun and the shade caused by obstructions.
In relation to the effects of trees and hedges the BRE guidelines states, “It is generally more difficult to calculate the effects of trees on daylight because of their irregular shape and because some light will generally penetrate through the crown. Where the effects of a new building on existing buildings nearby is being analysed, it is usual to ignore the effects of existing trees. This is because daylight is at its scarcest and most valuable in winter when most trees will not be in leaf.”
The trees were not included because they are mostly deciduous and guidelines recommends only including trees where there are dense bands of evergreen trees.
8.2 ConclusionShadow diagrams are a visual aid to understand where possible shading may occur. The BRE guidelines recommends using the March Equinox due the equal length of the day and night time.
It can be seen that the proposed development does not cast any additional shading to the surrounding properties on the 21st March until late evening when the sun is low and the existing walls cast long shadows and are self shading. There will be no shading to the CUS grounds which lie entirely to the south of the proposed development.
DRAFT
39
Proposed
Existing
N
N
8.3 Shadow Casting diagrams March Equinox
Figure 25: Shadow diagrams 21 March 09:00 GMT
DRAFT
40
Proposed
Existing
N
N
Figure 26: Shadow diagrams 21 March 11:00 GMT
DRAFT
41
Figure 27: Shadow diagrams 21 March 13:00 GMT
Proposed
Existing
N
N
DRAFT
42
Figure 28: Shadow diagrams 21 March 15:00 GMT
Proposed
Existing
N
N
DRAFT
43
Figure 29: Shadow diagrams 21 March 17:00 GMT
Proposed
Existing
N
N
DRAFT
44
Figure 30: Shadow diagrams 21 June 10:00 GMT +1 (DST)
8.4 Shadow Casting diagrams June Solstice
Proposed
Existing
N
N
DRAFT
45
Figure 31: Shadow diagrams 21 June 12:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
46
Figure 32: Shadow diagrams 21 June 14:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
47
Figure 33: Shadow diagrams 21 June 16:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
48
Figure 34: Shadow diagrams 21 June 18:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
49
N
8.5 Shadow Casting diagrams September Equinox
Figure 35: Shadow diagrams 21 September 09:00 GMT +1 (DST)
N
Proposed
Existing
DRAFT
50
N
N
Figure 36: Shadow diagrams 21 September 11:00 GMT +1 (DST)
Proposed
Existing
DRAFT
51
Figure 37: Shadow diagrams 21 September 13:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
52
Figure 38: Shadow diagrams 21 September 15:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
53
Figure 39: Shadow diagrams 21 September 17:00 GMT +1 (DST)
Proposed
Existing
N
N
DRAFT
54
Figure 40: Shadow diagrams 21 December 10:00 GMT
8.6 Shadow Casting diagrams December Solstice
Proposed
Existing
N
N
DRAFT
55
Figure 41: Shadow diagrams 21 December 12:00 GMT
Proposed
Existing
N
N
DRAFT
56
Figure 42: Shadow diagrams 21 December 14:00 GMT
Proposed
Existing
N
N
DRAFT
57
Figure 43: Shadow diagrams 21 December 16:00 GMT
Proposed
Existing
N
N