1
DAUMAR 40
Windows 95 software for labeling machines
Version 050199
2
IMPORTANT NOTICE ABOUT HOW TO INSTALL DE DAUMAR 40R 2.41
The Daumar 40 R.2.41 Version is prepared for working with Windows 95 and 98 programs.
If you install for the first time the DAUMAR 4R 2.41 Software, please check if the Windows
version contains the Imaging programme in the Accessories. If it is not the case, you should
install the VB10 Programme and proceed according to the manual book.
If it is installed on a previous Daumar 40R 2.41 version it is necessary to uninstall the
existing first version, and proceed as follows :
Mark the “Control Panel” and select the option of “Add or Remove hardware” and then mark
Daumar 40 R. Once the uninstall has been made, introduce the diskette labelled
“UNINSTALL” and then execute.
If you had followed the above instructions then you could install the Daumar 40R 2.41
programme.
NOTE:
It is possible that during the process of the installation appears some of the following
messages on the screen:
“ ERROR DE INFRACCION DE ACCESO AL COPIAR EL ARCHIVO” then select
Ignorar
After that the following message appears :
“ERROR DE INFRACCION DE ACCESO AL COPIAR EL ARCHIVO .... ¿ DESEA
PASAR POR ALTO EL ERROR?” then select SI
Please see the following two pages.
3
ERROR NUMBER 1
4
ERROR NUMBER 2.
5
IMPORTANT ORDERING INFORMATION
When ordering Concentrators to link labeling machines such as the Gircod, Eticod, EC-24
and Printcode to a PC, it is necessary to provide Daumar with the model number of your
clipping machine and labeling machine. The use of a Concentrator requires an EPROM
upgrade to the circuit board in the clipping machine, as per the following chart.
The possibilities are listed below:
Bagging unit Labeling machine Eprom code
number
Xarpamatic 78 / Girplus Eticod / Gircod Eprom 22-1-18A
Xarpamatic 78 / GH-10 EC-24 / 160 / Printcode Eprom 24-1-17C
Xarpamatic 78 / GH-10 EC-24 / 160 Printing on
top.
Eprom 24-1-17D
Xarpamatic 78 / GH-10 EC-24 / 120 / Printcode Eprom 24-1-18B
Xarpamatic 78 / GH-10 EC-24 / 120 Printing on
top.
Eprom 24-1-18
Xarpa-31 / Xarpa Evolution Eticod Eprom 22-1-20B
Xarpa-31 / Xarpa Evolution EC-24 / 160 Eprom 22-1-20B
Xarpa-31 / Xarpa Evolution EC-24 / 12 Eprom 22-1-20B
6
Important notice
An electronic key that enables communication between the PC and the labeling machine(s)
protects the Daumar 40 software. Without this electronic key, the software will only work in
demo mode, which does not allow communication with the labeling machine(s). The
electronic key should be connected to the parallel port of the PC before installing the
software. It has two connectors: the one marked Computer must be plugged to the PC parallel
port, and the other is attached to the printer cable. In the event that the PC has multiple keys,
make sure the Daumar 40 key is the first one attached to the computer?
Installing DAUMAR 40 software:
Notes:
For a complete control of the whole labeling installation from a PC:
- Minimum requirements: Pentium 100 processor with 32 MB RAM memory.
- Windows 95 operating system or Windows 98 (in case see installation in windows 98)
- For proper operation of this program, it is necessary that the PC Display be configured for
256 colors and 800 x 600 pixels. This can be verified and modified by clicking
on Display in the Control Panel. If you are using low-resolution labelling machine(s)
such as the EC-24, we recommend you experiment with Font Sizes to obtain the best
appearance.
- During the installation of Daumar 40, release 1.1, all screen prompts appear in Spanish.
This will be corrected in future releases.
7
Daumar 40 requires the latest version of Windows 95, which includes “Imaging”. To check
if your version of Windows 95 has Imaging, click on Start, Programs, Accessories, If your
system has Imaging, it should show up as one of the options. If Imaging is already installed,
please skip step 1.
Step 1 - Imaging:
Only follow this step if your version of Windows does not have “Imaging” installed.
- From the Start menu, select Run, insert the diskette labelled “VB10 1/3” and type a:
setup.exe. Follow the set-up instructions until “VB10” is correctly installed.
- From the Start menu, select Programs and click on the “VB10” icon.
- The program “VB10” will start, if it finds “Imaging” already installed in your PC, a
dialog screen will prompt you if you wish to re-install.
Step 2 – Daumar 40:
- From the Start menu, select Run and type a:setup exe. Follow the instructions on the
screen to install the program.
8
LABEL EDITING INSTRUCTIONS
WRITE TEXT Used for placing text on the label. Click the WRITE TEXT button; select the
area of the label you wish to place the text by clicking once on the label, type the text and press Enter
PLACE BAR CODE Used for placing bar codes on the label. Click the PLACE BAR CODE
button; select type of bar code, number, height, position in 0º or 180º, and control line. After pressing
OK the pointer becomes a bar code icon that you can place anywhere on the label and click once for
confirmation.
WRITE TEXT
PLACE BAR CODE
PRE-DEFINED TEXT
LOGOTYPES
VARIABLE DATA
DATES , LOTS , TEXTS
MAKE NEW LABEL
READ EXISTING LABEL
SAVE LABEL
COPY LABELS TO AND
FROM DISKETTES
EXIT
EDIT TEXTS AND CODES
FONTS
MOVE
ROTATE
CENTRE ERASE
LEFT RIGHT
LEFT BORDER
RIGHT BORDER
ZOOM
VARIABLE DATA LIST
VERSION
AND
LANGUAGE
9
PRE-DEFINED TEXT Used for placing pre-defined text strings. This button gives you access to pre-
defined text strings, which will be used frequently on labels. You can add, edit, delete and place these
text strings on the label.
LOGOTYPES Used for placing pre-defined graphic files in BMP format on the label. This
option displays graphic files in BMP format that are saved in the BMP folder of the DAUMAR 40
software. These graphic files must be in black & white (Monochrome). Typical applications are that
of logotypes or special promotional items.
VARIABLE DATA Button giving access to a screen where you can choose between Dates, Lots,
and Texts. After pressing OK the pointer becomes an icon that you can place anywhere on the label
and click once for confirmation.
MAKE NEW LABEL Click with your mouse and you will get a screen where you have to choose
the type of label that you wish and the resolution of your labelling machine (8 p/mm or 3 p/mm).
READ EXISTING LABEL Used for opening existing labels. This is necessary if you wish to edit
or copy a label. Descriptions of labels are available in the last version.
SAVE LABEL Once you are done creating or editing a label, you should save it so that the
labelling machines can retrieve the information. You will be asked to enter a three-digit number so
that the actual label can be saved to the hard disk.
COPY LABELS TO AND FROM DISKETTES Used to save a label to a diskette or to copy a label
from a diskette.
EXIT Click here to exit the program.
EDIT TEXTS AND CODES This button allows editing of already written text or codes. Just click on
top of the text and it will change color and become editable. If instead of text it is a bar code, a screen
will be shown for code selection and editing.
FONTS Place the mouse on the text and click: a screen will be shown to ask you for
the type of font, size, etc.
10
MOVE Clicking this button allows moving any object all over the label. Press the
mouse on top of the object (text, code, logo, etc.) and then drag the object to the desired position.
ROTATE This button allows the rotation of texts and bar codes. After selecting the
button, click on the object and it will rotate, 90º in the case of texts, and 180º if it is a bar code.
CENTER Select this button if you wish to center any object. A reference line will
appear in the middle of the label. It is also possible to bring this reference line to the left or right by
clicking on it and dragging it. Then any object that you click will be automatically replaced with
reference to the new position of the line.
ERASE Select this button and then click on any object that you want to delete.
LEFT Select this button if you wish to place any object to the left, where a reference
line will appear in the label. It is also possible to bring this reference line to the left or right clicking
on it and dragging it. Then any object that you click will be automatically replaced with reference to
the new position of the line.
RIGHT Select this button if you wish to place any object to the right, where a
reference line will appear in label. It is also possible to bring this reference line to the left or right
clicking on it and dragging it. Then any object that you click will be automatically replaced with
reference to the new position of the line.
LEFT BORDER This button allows to move to the left any object that is clicked after the
button is actuated. A reference line is shown at the extreme left edge of the label.
RIGHT BORDER This button allows to move to the right any object that is clicked after the
button is actuated. A reference line is shown at the extreme right edge of the label.
ZOOM Only available when editing 3 p/mm labels. Clicking the button makes a 2X
resizing, and clicking again goes back to the original size.
11
VARIABLE DATA LIST This button is only available when some variable data object has
been made (Dates, lots, or texts).
VERSION & LANGUAGE This button activates a screen that displays the
software version and allows language selection for the operation of Daumar 40. The default language
is Spanish. The language texts are located in archives written in text format in the “Daumar 40”
program folder and their names are : espanol.idi, english.idi, français.idi
In the event that other languages are required, the process is very simple: just copy any of these three
files and rename it with the name of the language to be added (example.idi). Double click on the new
file icon and you will see all the words in the program that you can edit at your convenience. This is
an easy way to configure Daumar 40 to display in another language.
Please note, it is very important not to touch the three asterisks at the end of the text.
12
DAUMAR 40R CONFIGURATION.
When “Daumar 40” is launched, there are really three programs that are simultaneously opened; the
first one is the label editor, and the other two are Allocation and Communications, which are both
shown minimised in the task bar.
1. Click Daumar logo.
Configuration screen.
Please check if the configuration is like this:
Click Daumar Logo, located on the right part of the screen.
The configuration will appear.
The user level must be Edition + Allocation + screening.
The type of work on network must be disconnected from the network.
See drawing 1.
13
2.. Make one label and store it.
3. Communications screen.
When clicking on Communications the following screen (drawing 2) will appear:
Select range between 01 and 96.
Select COM number.
See drawing 2
This window gives you the possibility to select the serial port number where the Converter RS-485 is
placed (com 1, com2 , etc). Just enter the proper digit in � com number: � and then press OK.
14
4. Allocation screen.
When clicking on Allocation the following screen (drawing 3) can be seen:
This window allows allocation of the type and number of the labelling machine, as well as the label’s
number. By pressing Add we enter the labeller’s number, the label type as per the available types
list, and the allocated label number. If we enter �000" for the value of allocated label, we allow the
user to request any label from the labelling machine. If we enter a value different to �000" we restrict
the possibilities of the user to print the label which number has been written in allocated label. After
entering data, save changes must be pressed and the new labeller’s number will be shown in the table.
The changes will become effective when clicking on Exit.
See drawing 3.
5. Communications screen.
Go back to communications and activate communications.
15
The communications can be switched on and off by just clicking the Activate/Deactivate button.
When communications are ON, you can see the different numbers of the labellers quickly changing in
the Checking labelling machine window as the PC is systematically scans the attached labelling
machines.
See drawing 4.
WIRING CONNECTIONS
16
Before running wire, one should determine the type of installation necessary. There are two basic
types of installations;
(1) A PC connected directly to one or more High Density labelling machines or (2) A PC connected to
one or more Concentrators.
When connecting Low Density labelling machines such as the EC-24, a Concentrator must be placed
between the PC and the labelling machine. It is possible to connect up to 16 labelling machines to each
Concentrator. The software “Daumar 40” allows a maximum of 96 labelling machines on the network,
which means a maximum of 6 Concentrators.
If you are installing high density labelling machines such as the EC-40, you do not need a
Concentrator.
An RS-485 connector must be placed on an available RS-232 (serial) port on the PC. This improves
the RF-noise tolerance and allows a longer wire run. The wire specifications are Shielded
Twisted Pair, 2-Pair.
Wiring a PC directly to one or more High Density Labelling Machines
See figure 6 for proper schematic layout.
1 – Connect the RS-485 converter to an available serial port (RS-232) on the PC.
2 – Run the cable from the PC to the labelling machine(s), making sure to stay away from electrical
outlets, power cords and motors.(see wiring PC to concentrator or EC-40).
3 – Configure the local stations (Labelling Machines). The circuit board that controls each local
station (CI-7033) has 4 sliding switches, that allow 16 different values (see figure 4). Make sure the
first local station is 01, the second is 02, the third 03, etc..
Wiring a PC to one or more Concentrators
17
See figure 1 for proper schematic layout.
1 – Connect the RS-485 converter to an available serial port (RS-232) on the PC.
2 – Run the cable from the PC to the Concentrator(s). First, install the wire between the PC and the
Concentrators. Cable sample:
Shielded Twisted Pair, 2-Pair.
Sample:
18
The wire must be laid as far as possible from any source of electrical noises (RF Interference). This
type of network connection requires that the transmission line have impedance of 60 ohm.
Consequently, it is necessary to place terminators at both ends of the line. Two resistors of 120 ohm
must be installed at the end connected to the RS-485 converter, and two more resistors of 120 ohm at
the line’s end. It is necessary that each node or union coincide with the connector of each
Concentrator, in other words, the Concentrators are connected in parallel, not in series.
The line coming from the RS-485 converter must go to the first Concentrator, and from this unit’s
connector the line must go to the next Concentrator, and so successively. Be careful not to mix the
polarity of the wires.
3 - Wire the Concentrator to the labelling machine(s), as can be seen in figure 2.
If replacing a Programming Unit for a Concentrator, the already existing line between EC-24’s and
Programming Unit can be used. Just pay attention not to change the polarity of the wires when
replacing the Programming Unit’s connector for the Concentrator’s numbered connecting rule.
If it is a new installation, proceed as in step 2, with the exception that the terminators are not
necessary.
4 – Configure the Concentrator(s). Each Concentrator can handle 16 labelling machines, and we can
install up to 6 Concentrators. It is logically required that each Concentrator has a single ID number
that distinguishes it from the others. When opening the Concentrator’s cover you can see that the small
circuit board (9049) has some sliding switches (see figure 3). These switches allow you to change the
number of each Concentrator. Here is the table
with the numbers allocation :
Concentrator 0: local station numbers 1 to16
Concentrator 1: local station number 17 to 32
Concentrator 2: local station number 33 to 48
Concentrator 3: local station number 49 to 64
Concentrator 4: local station number 65 to 80
Concentrator 5: local station number 81 to 96
5 – Configure the local stations (Labelling Machines). The circuit board that controls each local
station (CI-7033) has 4 sliding switches, that allow 16 different values (see figure 4). Make sure the
first local station is 01, the second is 02, the third 03, etc..
19
EC-40 CONTROL BOX
The EC-40 control box is an autonomous electronic device that can handle high definition printing
machines (Gircod-Plus,etc.) It does not need a Concentrator and can be connected to an RS-485
network (see figure 6). Up to 32 high resolution labelling machines can be connected to the same PC.
Each time a printing order is given, the labeller prints a label. There are two connectors at the back of
the machine, X1 and X2. X1 receives the start order as per the instructions in figure 5. This contact
does not obtain any internal power from the machine, it must be connected to the power source of the
bagging machine where the labelling machine is fitted. X2 is the communications connector that must
be connected according to the wiring connections instructions.
CONFIGURATION
There are two sliding switches inside the control box that allow to set-up the different operating
modes.
SW1
OFF
EC-40 AUTONOMOUS CONTROL BOX
ON
INTEGRATED IN XARPA-31
SW2 SW3 SW4
20
ON
ON
ON
EC-40 160 SIGN ON SCREEN E16
OFF
ON
ON
EC-40 120 SIGN ON SCREEN E12
ON
OFF
ON
GIRCOD 1 SIGN ON SCREEN E-1
OFF
OFF
ON
GIRCOD 2 SIGN ON SCREEN E-2
ON
ON
OFF
GIRCOD 3 SIGN ON SCREEN E-3
SW5 AVAILABLE
SW6 AVAILABLE
CONFIGURATION OF THE LABELLING MACHINE NUMBER
Each labelling machine must have a unique number in the range of 1 to 96.
Here is the process to select a number:
- Launch the control box while pressing the “request label” button.
- You will see �000" on screen, and then “opt”
- With the arrows select the number �003" and press the “request label” button.
- Enter the control box number (1 to 96), then press the “request label” button and the value
will be stored in memory.
REQUEST LABEL
With the keys of hundreds, tens, and units, select the label number that you wish and press the “request
label” button.
21 Figure 1
CONCENTRATORS
NETWORK
CONNECTION
Connector to concentrator
Connector to concentrator
To labeler’s
Control box
To labeler’s
Control box
To labeler’s
Control box
Terminator
Unit n
Unit n
Connector to concentrator
Unit n
Twisted pair
shielded wire
Connector to Concentrator Twisted pair shielded
wire (4 wires)
Connector to Concentrator
To labeler’s
Control box
Terminator
Unit 2
To labeler’s
Control box
To labeler’s
Control box
Connector to Concentrator
Terminator
Unit 2
CONCENTRATORS
NETWORK
CONNECTION
Unit 2
Connector to PC serial port
22 Figure 2
COMPARISON
PROGRAMMING UNIT - CONCENTRATOR
Connection
between
labellers and a
Progrmming
unit Unit 1
Labeller’s
connector
Unit 2
Labeller’s
connector
Unit 3
Labeller’s
connector
Unit n
Labeller’s
connector
Connection
between
labellers and
a concentrator Unit 1
Labeller’s
connector
Unit 2
Labeller’s
connector
Unit 3
Labeller’s
connector
Unit n
Labeller’s
connector
Programming
Unit connector
Concentrator
connector
23 Figure 3
Concentrator 6
Labellers
From 81 to 96
TABLE
OF
CONCENTRATORS
Concentrator 4
Labellers
From 49 to 64
Concentrator 2
Labellers
From 17 to 32
Concentrator 3
Labellers
From 33 to 48
Concentrator 1
Labellers
From 1 to 16
Concentrator 5
Labellers
From 65 to 80
24 Figure 4
CONFIGURATION OF
LABELLERS ATTACHED
TO A CONCENTRATOR
Symbol equivalence
Concentrator 1
Labellers
From 1 to 16
Concentrator 2
Labellers
From 17 to 32
Concentrator 3
Labellers
From 33 to 48
Concentrator 4
Labellers
From 49 to 64
Concentrator 5
Labellers
From 65 to 80
Concentrator 6
Labellers
From 81 to 96
01
02
17
18
33
34
49
50
65
66
81
82
03 19 35 51 67 83
04 20 36 52 68 84
05
06
07
08
21
22
23
24
37
38
39
40
53
54
55
56
69
70
71
72
85
86
87
88
11
09
10
27
25
26 42
43
41
58
59
57
74
75
73
90
91
89
12
13
14
28
29
30
44
45
46
60
61
62
76
77
78
92
93
94
15
16
31
32
47 63 79
48 64 80
95
96
25 Figure 5
EC-40
CONNECTION
26
EC-40 NETWORK CONNECTIONS
Maximum number
of EC-40 is 32
units.
A terminator must
be placed at the
begining and the
end of the line.
The installation
cable must be
twisted pair
shielded 4 wires.
EC-40 connector
Unit nº 32
EC-40 connector
Unit nº 2
EC-40 connector
Unit nº 1
Terminator
Connector to PC
serial port
Figure 6
27
Unit 2
Figure 7
NETWORK
CONNECTIONS FROM
XARPA-31 TO EC-40
Twisted
wire
Unit 1
Unit 32
Maximum of 32 units.
A terminator is required at
each end of the line.
Shielded twisted pair wire
must be used.
The first twisted pair will
be 1 & 2.
The second twisted pair
will be 3 & 4.
Serial port PC connection
Terminator
28
XARPA 31 WITH INTEGRATED CONTROL OF
LABELLING MACHINE EC-40
Once the installation has been carried out as previously described, connect to the control box of the
XARPA-31, which in this case is a circular connector with four contacts (see figure 7).
CONFIGURATION
The number of the labelling machine allocated to the XARPA must be defined and in order to do
this the configuration of the Xarpa must be set. This process is carried out using the screen of the
Xarpa
First of all select option “0”, LABEL, from the main screen of the Xarpa.
The screen referring to the labelling machine will appear and, on the second line, which reads
number of label, press the key sequence 3 8 7 C, and a service menu will appear. Choose option 3
“LOCATION NUMBER”, and the following will appear “N. OF LABELLING M.(01 TO
96):” introduce the desired number and press “M”. Then exit by pressing “C” until the main menu
appears.
NOTE: If you wish to consult the selected location number, on pressing “0” from the main menu,
the first line shows: the location number, the type of labelling machine and the label which has
been memorised.
Concentrator display/EC-40 display.
The display is a device that permits us to check what is going on in the working process.
We have different steps or phases (so the display will show what the situation is):
29
1.
The display is not showing anything. The display is completely off.
Check if the concentrator/local 40 is correctly connected to the main power.
Check if the primary of the concentrator transformer is receiving 220 V.
Check if there is any fuse blown.
Check if the secondary of the concentrator transformer is giving 11V and 12V,
2.
PC / L-- --.
The display is showing PC or L -– and after a few seconds PC again.
It means that there is no communication between the computer and the concentrator.
-Check if in the computer the Daumar 40 is running.
-Check if the concentrator sliding switches are setup in correct position. (See pag.18 figure 4 to
configure labelers attached to a concentrator).
-Check if the settings of the communication and the allocation are correct. (Make sure that the
number of labeler you configure with the sliding switches in the Circuit board 7033 “local unit”,
is the same as you configure in the allocation option inside the Daumar 40 software.
If you connect more than one labeler, see also page 18 in the Daumar 40 book.
-Check if the converter transformer is correctly connected to the “220V” power supply and
check if the output is 9VDC.Also check if it is connected to the serial port, if necessary we also
send to you an adapter in case you have a 9 pins Com.
-Check if the wires are connected as they should be.
-Check if the “KEY” is correctly connected (must be connected to the parallel port of the
computer).
If you still have the same information on the display screen; you may have some problems in
the computer COM.
To check if there is any problem in the COM, you can use the HYPER TERMINAL.
30
3.Step 1.
L01,L02,L03...L16 / L17,L18,L19...L32.
The display is showing L 01, after L 02...
Lets say, that when we configure 16 labelers attached to the first concentrator we will see on the
display that the number 01 will be continuously changing until it arrives to number 16 and after
the number 16 the number 01 will reappear and so on.
When this happens, it means that the computer is communicating with the concentrator.
In case of local 40 you see the number of label in memory and when is requesting a label you
see the number changing.
Step 2. REQUESTING LABEL.E 01
The display is showing E 01 when you request one label from the local unit and depending on
the labeller number you will see ”E “and then the number of the labeller.
This means that the concentrator is receiving the request for one label from the Local Unit
(7033).
Step 3.PC IS PREPARING THE LABEL TO BE SENT.R-01.
The display will show “ r 01”.
At this moment you will see that the computer screen is going to change it’s format, showing the
label, but inverted, lets say that now the computer is preparing the label to be sent to the
concentrator.
Sometimes this step is very fast, because the computer did this sometime before, if you request this
label for the first time it takes a little more time.
4. PC IS SENDING THE LABEL. + R01
The display will show you “+ r 01”.
At this moment the computer is sending the label to the concentrator.
The number is the number of labelling machine.
5.CONCENTRATOR IS SENDING THE LABEL TO THE
LOCAL UNIT ( 3PPM). T-01.
The display will show you “ t – 01”.
At this moment the concentrator is sending the label to the local unit “board 7033”.
Only in case concentrator.
31
Step 1.
The display will show you again the same information as step 3. “L-01...L-02...L-01”
Now the label has been sent OK. And the system is waiting for another label request.
ALARMS:
These steps can be interrupted by an alarm at the end of the process or during it.
The display can show different alarms as follows:
- A01.
PC is not sending labels.
- A02.
Label does not exist.
Will appear at the end of the step 4.
- A03.
Repeat 10 times the same data. It means that the machine has sent the information of the label
10 times but this information has not been completely received from the concentrator.
- A04.
The type of label that the computer sent is not the same as the label machine type.
This means for example that we ask for one label 120 mm/3ppm and the labelling machine is in
an EC-24 160mm/3ppm format.
-A05.
Over-temperature thermal head alarm.
- A00.
The thermal head temperature alarm disappears. (Only in X-31).
- A06.
Communication alarm.
32
Note:
If for any reason the computer will not communicate with the concentrator, we suggest to
turning off the concentrator, turn off the power for the converter RS485, close the
communications, and after close the allocation: then exit from Daumar 40, restart the computer
and open Daumar 40 again.
In the communication window to close the communication place your mouse on the colon after
“checking labelling” and click the left button.
In the allocation window to close the allocation place the mouse on the colon
after “labeller number” and click the left button.
33
LOCAL 40 TEST
Options Menu.
Here is the process to select a number:
- Launch the control box while pressing the “request label” button.
- You will see �000" on screen, and then “opt”
- With the keys of hundreds, tens, and units, select the label numbers that you wish and
press the “request label” button.
001= See number of labels.
With key of hundreds select the digits; in units check the value.
1-0, 2-0,3-0, 4-0, 5-0, 6-0, 7-3, 8-7, 9-6.
Number of labels: 000000376
Request label button to exit.
002 = Delete label counter.
003 = Program number of labeller (priority from the hardware).
Enter value with units and tens. (01 - 96).
Request label button to exit.
004 = RAM test.
Tens (-) = Exit from test.
005 = Label Ram test (outside). (Electronic department).
Request label button to exit.
006 = Input test.
See by binary mode all the inputs.
Request label button to exit.
007 = Input test. (Labeller selector or options).
See by binary mode all the inputs.
Request label button to exit.
34
008 = Output test.
Output selection with hundreds.
Units (+) = to connect.
Units (-) = to disconnect,
Request label button to exit.
009 = See Thermal head temperature.
Request label button to exit.
010 = Com 1Test: (Electronic Department).
Request label button to exit.
011 = Com 2Test:
Request label button to exit.
012 = Thermal head printer lines Test.
Request label button to exit.
013 = Thermal head voltage test ON/OFF.
Request label button to exit.
014 = (T1). Delay start cutting.
Request label button to exit.
015 = (T2). Cutting time.
Request label button to exit.
016 = (T3). Finger turning Time.
Request label button to exit.
017 = (T4). Delay starts the translation.
Request label button to exit.
018 = (T5). Translation time.
Request label button to exit.
019 = (T6). Delay between stop the motor and reverse the direction.
Request label button to exit.
020 = (T7). Reversing time motor. (Stopping).
Request label button to exit.
35
EC-40 Times.
Xarpa- 31
C-387 + label
EC-40 (160 mm.). EC_40 (120 mm.) EC-24 (160-120)
T-1: 0 0 0
T-2: cutting.
70 90 250
T-3: finger
movement.
250 400 0
T-4: delay translation.
150 150 0
T-5: translation time. 150 300 0
T-6: delay between
the stopping of the
motor and the
reversion
050 050 0
T-7: 036-reversion
time of the motor
036 036 0
LEA 80
T-1: label pusher time 300
T-2: vacuum time 250
T-3: delay vacuum 300
T-4: delay start label 0
T-5 delay label movement 0
36
CEA 44.
CS-28 CB-34
T-1: label pusher time 500 300
T-2: vacuum time 500 500
T-3: delay start label pusher 300 0
T-4: delay begins to print 20 40
T-5 delay start vacuum 200 200
LOCAL 40 TEST
Options Menu.
Here is the process to select a number:
- Launch the control box while pressing the “request label” button.
- You will see �000" on screen, and then “opt”
- With the keys of hundreds, tens, and units, select the label numbers that you
wish and press the “request label” button.
001= See number of labels.
With key of hundreds select the digits; in units check the value.
1-0, 2-0,3-0, 4-0, 5-0, 6-0, 7-3, 8-7, 9-6.
Number of labels: 000000376
Request label button to exit.
002 = Delete label counter.
003 = Program number of labeler (priority from the hardware).
Enter value with units and tens. (01 - 96).
Request label button to exit.
004 = RAM test.
Tens (-) = Exit from test.
37
005 = Label Ram test (outside). (Electronic department).
Request label button to exit.
006 = Input test.
See by binary mode all the inputs.
Request label button to exit.
007 = Input test. (Labeller selector or options).
See by binary mode all the inputs.
Request label button to exit.
008 = Output test.
Output selection with hundreds
Units (+) = to connect.
Units (-) = to disconnect,
Output n-2 vacuum.
Output n-3 pusher.
Output n-4 motor.
Request label button to exit.
009 = See Thermal head temperature.
Request label button to exit.
010 = Com 1Test: (Electronic Department).
Request label button to exit.
011 = Com 2Test:
Request label button to exit.
012 = Thermal head printer lines Test.
Request label button to exit.
013 = Thermal head voltage test ON/OFF.
Request label button to exit.
014 = (T1). T-1: label pusher time
Request label button to exit.
015 = (T2). T-2: vacuum time
Request label button to exit.
016 = (T3). T-3: delay start label pusher
Request label button to exit.
38
017 = (T4). T-4: delay begins to print.
Request label button to exit.
018 = (T5). T-5 delay starts the vacuum.
Request label button to exit.
019 = (T6). Free
Request label button to exit.
020 = (T7). Free.
Request label button to exit.
39
Gircod labels
A
B
Gircod 1 :
3 ppm : A= 40 mm. B=50.6 mm.
8 ppm : A= 43.25 mm. B=54.75 mm.
Gircod 2 :
3 ppm : A= 40 mm. B=53.3 mm.
8 ppm : A= 43.25 mm. B=56 mm.
Gircod 3 :
3 ppm : A= 64 mm. B=53.3 mm.
8 ppm : A=69.12 mm. B=56 mm.