Daumar40r English

39
1 DAUMAR 40 Windows 95 software for labeling machines Version 050199

description

Daumar40r English

Transcript of Daumar40r English

Page 1: Daumar40r English

1

DAUMAR 40

Windows 95 software for labeling machines

Version 050199

Page 2: Daumar40r English

2

IMPORTANT NOTICE ABOUT HOW TO INSTALL DE DAUMAR 40R 2.41

The Daumar 40 R.2.41 Version is prepared for working with Windows 95 and 98 programs.

If you install for the first time the DAUMAR 4R 2.41 Software, please check if the Windows

version contains the Imaging programme in the Accessories. If it is not the case, you should

install the VB10 Programme and proceed according to the manual book.

If it is installed on a previous Daumar 40R 2.41 version it is necessary to uninstall the

existing first version, and proceed as follows :

Mark the “Control Panel” and select the option of “Add or Remove hardware” and then mark

Daumar 40 R. Once the uninstall has been made, introduce the diskette labelled

“UNINSTALL” and then execute.

If you had followed the above instructions then you could install the Daumar 40R 2.41

programme.

NOTE:

It is possible that during the process of the installation appears some of the following

messages on the screen:

“ ERROR DE INFRACCION DE ACCESO AL COPIAR EL ARCHIVO” then select

Ignorar

After that the following message appears :

“ERROR DE INFRACCION DE ACCESO AL COPIAR EL ARCHIVO .... ¿ DESEA

PASAR POR ALTO EL ERROR?” then select SI

Please see the following two pages.

Page 3: Daumar40r English

3

ERROR NUMBER 1

Page 4: Daumar40r English

4

ERROR NUMBER 2.

Page 5: Daumar40r English

5

IMPORTANT ORDERING INFORMATION

When ordering Concentrators to link labeling machines such as the Gircod, Eticod, EC-24

and Printcode to a PC, it is necessary to provide Daumar with the model number of your

clipping machine and labeling machine. The use of a Concentrator requires an EPROM

upgrade to the circuit board in the clipping machine, as per the following chart.

The possibilities are listed below:

Bagging unit Labeling machine Eprom code

number

Xarpamatic 78 / Girplus Eticod / Gircod Eprom 22-1-18A

Xarpamatic 78 / GH-10 EC-24 / 160 / Printcode Eprom 24-1-17C

Xarpamatic 78 / GH-10 EC-24 / 160 Printing on

top.

Eprom 24-1-17D

Xarpamatic 78 / GH-10 EC-24 / 120 / Printcode Eprom 24-1-18B

Xarpamatic 78 / GH-10 EC-24 / 120 Printing on

top.

Eprom 24-1-18

Xarpa-31 / Xarpa Evolution Eticod Eprom 22-1-20B

Xarpa-31 / Xarpa Evolution EC-24 / 160 Eprom 22-1-20B

Xarpa-31 / Xarpa Evolution EC-24 / 12 Eprom 22-1-20B

Page 6: Daumar40r English

6

Important notice

An electronic key that enables communication between the PC and the labeling machine(s)

protects the Daumar 40 software. Without this electronic key, the software will only work in

demo mode, which does not allow communication with the labeling machine(s). The

electronic key should be connected to the parallel port of the PC before installing the

software. It has two connectors: the one marked Computer must be plugged to the PC parallel

port, and the other is attached to the printer cable. In the event that the PC has multiple keys,

make sure the Daumar 40 key is the first one attached to the computer?

Installing DAUMAR 40 software:

Notes:

For a complete control of the whole labeling installation from a PC:

- Minimum requirements: Pentium 100 processor with 32 MB RAM memory.

- Windows 95 operating system or Windows 98 (in case see installation in windows 98)

- For proper operation of this program, it is necessary that the PC Display be configured for

256 colors and 800 x 600 pixels. This can be verified and modified by clicking

on Display in the Control Panel. If you are using low-resolution labelling machine(s)

such as the EC-24, we recommend you experiment with Font Sizes to obtain the best

appearance.

- During the installation of Daumar 40, release 1.1, all screen prompts appear in Spanish.

This will be corrected in future releases.

Page 7: Daumar40r English

7

Daumar 40 requires the latest version of Windows 95, which includes “Imaging”. To check

if your version of Windows 95 has Imaging, click on Start, Programs, Accessories, If your

system has Imaging, it should show up as one of the options. If Imaging is already installed,

please skip step 1.

Step 1 - Imaging:

Only follow this step if your version of Windows does not have “Imaging” installed.

- From the Start menu, select Run, insert the diskette labelled “VB10 1/3” and type a:

setup.exe. Follow the set-up instructions until “VB10” is correctly installed.

- From the Start menu, select Programs and click on the “VB10” icon.

- The program “VB10” will start, if it finds “Imaging” already installed in your PC, a

dialog screen will prompt you if you wish to re-install.

Step 2 – Daumar 40:

- From the Start menu, select Run and type a:setup exe. Follow the instructions on the

screen to install the program.

Page 8: Daumar40r English

8

LABEL EDITING INSTRUCTIONS

WRITE TEXT Used for placing text on the label. Click the WRITE TEXT button; select the

area of the label you wish to place the text by clicking once on the label, type the text and press Enter

PLACE BAR CODE Used for placing bar codes on the label. Click the PLACE BAR CODE

button; select type of bar code, number, height, position in 0º or 180º, and control line. After pressing

OK the pointer becomes a bar code icon that you can place anywhere on the label and click once for

confirmation.

WRITE TEXT

PLACE BAR CODE

PRE-DEFINED TEXT

LOGOTYPES

VARIABLE DATA

DATES , LOTS , TEXTS

MAKE NEW LABEL

READ EXISTING LABEL

SAVE LABEL

COPY LABELS TO AND

FROM DISKETTES

EXIT

EDIT TEXTS AND CODES

FONTS

MOVE

ROTATE

CENTRE ERASE

LEFT RIGHT

LEFT BORDER

RIGHT BORDER

ZOOM

VARIABLE DATA LIST

VERSION

AND

LANGUAGE

Page 9: Daumar40r English

9

PRE-DEFINED TEXT Used for placing pre-defined text strings. This button gives you access to pre-

defined text strings, which will be used frequently on labels. You can add, edit, delete and place these

text strings on the label.

LOGOTYPES Used for placing pre-defined graphic files in BMP format on the label. This

option displays graphic files in BMP format that are saved in the BMP folder of the DAUMAR 40

software. These graphic files must be in black & white (Monochrome). Typical applications are that

of logotypes or special promotional items.

VARIABLE DATA Button giving access to a screen where you can choose between Dates, Lots,

and Texts. After pressing OK the pointer becomes an icon that you can place anywhere on the label

and click once for confirmation.

MAKE NEW LABEL Click with your mouse and you will get a screen where you have to choose

the type of label that you wish and the resolution of your labelling machine (8 p/mm or 3 p/mm).

READ EXISTING LABEL Used for opening existing labels. This is necessary if you wish to edit

or copy a label. Descriptions of labels are available in the last version.

SAVE LABEL Once you are done creating or editing a label, you should save it so that the

labelling machines can retrieve the information. You will be asked to enter a three-digit number so

that the actual label can be saved to the hard disk.

COPY LABELS TO AND FROM DISKETTES Used to save a label to a diskette or to copy a label

from a diskette.

EXIT Click here to exit the program.

EDIT TEXTS AND CODES This button allows editing of already written text or codes. Just click on

top of the text and it will change color and become editable. If instead of text it is a bar code, a screen

will be shown for code selection and editing.

FONTS Place the mouse on the text and click: a screen will be shown to ask you for

the type of font, size, etc.

Page 10: Daumar40r English

10

MOVE Clicking this button allows moving any object all over the label. Press the

mouse on top of the object (text, code, logo, etc.) and then drag the object to the desired position.

ROTATE This button allows the rotation of texts and bar codes. After selecting the

button, click on the object and it will rotate, 90º in the case of texts, and 180º if it is a bar code.

CENTER Select this button if you wish to center any object. A reference line will

appear in the middle of the label. It is also possible to bring this reference line to the left or right by

clicking on it and dragging it. Then any object that you click will be automatically replaced with

reference to the new position of the line.

ERASE Select this button and then click on any object that you want to delete.

LEFT Select this button if you wish to place any object to the left, where a reference

line will appear in the label. It is also possible to bring this reference line to the left or right clicking

on it and dragging it. Then any object that you click will be automatically replaced with reference to

the new position of the line.

RIGHT Select this button if you wish to place any object to the right, where a

reference line will appear in label. It is also possible to bring this reference line to the left or right

clicking on it and dragging it. Then any object that you click will be automatically replaced with

reference to the new position of the line.

LEFT BORDER This button allows to move to the left any object that is clicked after the

button is actuated. A reference line is shown at the extreme left edge of the label.

RIGHT BORDER This button allows to move to the right any object that is clicked after the

button is actuated. A reference line is shown at the extreme right edge of the label.

ZOOM Only available when editing 3 p/mm labels. Clicking the button makes a 2X

resizing, and clicking again goes back to the original size.

Page 11: Daumar40r English

11

VARIABLE DATA LIST This button is only available when some variable data object has

been made (Dates, lots, or texts).

VERSION & LANGUAGE This button activates a screen that displays the

software version and allows language selection for the operation of Daumar 40. The default language

is Spanish. The language texts are located in archives written in text format in the “Daumar 40”

program folder and their names are : espanol.idi, english.idi, français.idi

In the event that other languages are required, the process is very simple: just copy any of these three

files and rename it with the name of the language to be added (example.idi). Double click on the new

file icon and you will see all the words in the program that you can edit at your convenience. This is

an easy way to configure Daumar 40 to display in another language.

Please note, it is very important not to touch the three asterisks at the end of the text.

Page 12: Daumar40r English

12

DAUMAR 40R CONFIGURATION.

When “Daumar 40” is launched, there are really three programs that are simultaneously opened; the

first one is the label editor, and the other two are Allocation and Communications, which are both

shown minimised in the task bar.

1. Click Daumar logo.

Configuration screen.

Please check if the configuration is like this:

Click Daumar Logo, located on the right part of the screen.

The configuration will appear.

The user level must be Edition + Allocation + screening.

The type of work on network must be disconnected from the network.

See drawing 1.

Page 13: Daumar40r English

13

2.. Make one label and store it.

3. Communications screen.

When clicking on Communications the following screen (drawing 2) will appear:

Select range between 01 and 96.

Select COM number.

See drawing 2

This window gives you the possibility to select the serial port number where the Converter RS-485 is

placed (com 1, com2 , etc). Just enter the proper digit in � com number: � and then press OK.

Page 14: Daumar40r English

14

4. Allocation screen.

When clicking on Allocation the following screen (drawing 3) can be seen:

This window allows allocation of the type and number of the labelling machine, as well as the label’s

number. By pressing Add we enter the labeller’s number, the label type as per the available types

list, and the allocated label number. If we enter �000" for the value of allocated label, we allow the

user to request any label from the labelling machine. If we enter a value different to �000" we restrict

the possibilities of the user to print the label which number has been written in allocated label. After

entering data, save changes must be pressed and the new labeller’s number will be shown in the table.

The changes will become effective when clicking on Exit.

See drawing 3.

5. Communications screen.

Go back to communications and activate communications.

Page 15: Daumar40r English

15

The communications can be switched on and off by just clicking the Activate/Deactivate button.

When communications are ON, you can see the different numbers of the labellers quickly changing in

the Checking labelling machine window as the PC is systematically scans the attached labelling

machines.

See drawing 4.

WIRING CONNECTIONS

Page 16: Daumar40r English

16

Before running wire, one should determine the type of installation necessary. There are two basic

types of installations;

(1) A PC connected directly to one or more High Density labelling machines or (2) A PC connected to

one or more Concentrators.

When connecting Low Density labelling machines such as the EC-24, a Concentrator must be placed

between the PC and the labelling machine. It is possible to connect up to 16 labelling machines to each

Concentrator. The software “Daumar 40” allows a maximum of 96 labelling machines on the network,

which means a maximum of 6 Concentrators.

If you are installing high density labelling machines such as the EC-40, you do not need a

Concentrator.

An RS-485 connector must be placed on an available RS-232 (serial) port on the PC. This improves

the RF-noise tolerance and allows a longer wire run. The wire specifications are Shielded

Twisted Pair, 2-Pair.

Wiring a PC directly to one or more High Density Labelling Machines

See figure 6 for proper schematic layout.

1 – Connect the RS-485 converter to an available serial port (RS-232) on the PC.

2 – Run the cable from the PC to the labelling machine(s), making sure to stay away from electrical

outlets, power cords and motors.(see wiring PC to concentrator or EC-40).

3 – Configure the local stations (Labelling Machines). The circuit board that controls each local

station (CI-7033) has 4 sliding switches, that allow 16 different values (see figure 4). Make sure the

first local station is 01, the second is 02, the third 03, etc..

Wiring a PC to one or more Concentrators

Page 17: Daumar40r English

17

See figure 1 for proper schematic layout.

1 – Connect the RS-485 converter to an available serial port (RS-232) on the PC.

2 – Run the cable from the PC to the Concentrator(s). First, install the wire between the PC and the

Concentrators. Cable sample:

Shielded Twisted Pair, 2-Pair.

Sample:

Page 18: Daumar40r English

18

The wire must be laid as far as possible from any source of electrical noises (RF Interference). This

type of network connection requires that the transmission line have impedance of 60 ohm.

Consequently, it is necessary to place terminators at both ends of the line. Two resistors of 120 ohm

must be installed at the end connected to the RS-485 converter, and two more resistors of 120 ohm at

the line’s end. It is necessary that each node or union coincide with the connector of each

Concentrator, in other words, the Concentrators are connected in parallel, not in series.

The line coming from the RS-485 converter must go to the first Concentrator, and from this unit’s

connector the line must go to the next Concentrator, and so successively. Be careful not to mix the

polarity of the wires.

3 - Wire the Concentrator to the labelling machine(s), as can be seen in figure 2.

If replacing a Programming Unit for a Concentrator, the already existing line between EC-24’s and

Programming Unit can be used. Just pay attention not to change the polarity of the wires when

replacing the Programming Unit’s connector for the Concentrator’s numbered connecting rule.

If it is a new installation, proceed as in step 2, with the exception that the terminators are not

necessary.

4 – Configure the Concentrator(s). Each Concentrator can handle 16 labelling machines, and we can

install up to 6 Concentrators. It is logically required that each Concentrator has a single ID number

that distinguishes it from the others. When opening the Concentrator’s cover you can see that the small

circuit board (9049) has some sliding switches (see figure 3). These switches allow you to change the

number of each Concentrator. Here is the table

with the numbers allocation :

Concentrator 0: local station numbers 1 to16

Concentrator 1: local station number 17 to 32

Concentrator 2: local station number 33 to 48

Concentrator 3: local station number 49 to 64

Concentrator 4: local station number 65 to 80

Concentrator 5: local station number 81 to 96

5 – Configure the local stations (Labelling Machines). The circuit board that controls each local

station (CI-7033) has 4 sliding switches, that allow 16 different values (see figure 4). Make sure the

first local station is 01, the second is 02, the third 03, etc..

Page 19: Daumar40r English

19

EC-40 CONTROL BOX

The EC-40 control box is an autonomous electronic device that can handle high definition printing

machines (Gircod-Plus,etc.) It does not need a Concentrator and can be connected to an RS-485

network (see figure 6). Up to 32 high resolution labelling machines can be connected to the same PC.

Each time a printing order is given, the labeller prints a label. There are two connectors at the back of

the machine, X1 and X2. X1 receives the start order as per the instructions in figure 5. This contact

does not obtain any internal power from the machine, it must be connected to the power source of the

bagging machine where the labelling machine is fitted. X2 is the communications connector that must

be connected according to the wiring connections instructions.

CONFIGURATION

There are two sliding switches inside the control box that allow to set-up the different operating

modes.

SW1

OFF

EC-40 AUTONOMOUS CONTROL BOX

ON

INTEGRATED IN XARPA-31

SW2 SW3 SW4

Page 20: Daumar40r English

20

ON

ON

ON

EC-40 160 SIGN ON SCREEN E16

OFF

ON

ON

EC-40 120 SIGN ON SCREEN E12

ON

OFF

ON

GIRCOD 1 SIGN ON SCREEN E-1

OFF

OFF

ON

GIRCOD 2 SIGN ON SCREEN E-2

ON

ON

OFF

GIRCOD 3 SIGN ON SCREEN E-3

SW5 AVAILABLE

SW6 AVAILABLE

CONFIGURATION OF THE LABELLING MACHINE NUMBER

Each labelling machine must have a unique number in the range of 1 to 96.

Here is the process to select a number:

- Launch the control box while pressing the “request label” button.

- You will see �000" on screen, and then “opt”

- With the arrows select the number �003" and press the “request label” button.

- Enter the control box number (1 to 96), then press the “request label” button and the value

will be stored in memory.

REQUEST LABEL

With the keys of hundreds, tens, and units, select the label number that you wish and press the “request

label” button.

Page 21: Daumar40r English

21 Figure 1

CONCENTRATORS

NETWORK

CONNECTION

Connector to concentrator

Connector to concentrator

To labeler’s

Control box

To labeler’s

Control box

To labeler’s

Control box

Terminator

Unit n

Unit n

Connector to concentrator

Unit n

Twisted pair

shielded wire

Connector to Concentrator Twisted pair shielded

wire (4 wires)

Connector to Concentrator

To labeler’s

Control box

Terminator

Unit 2

To labeler’s

Control box

To labeler’s

Control box

Connector to Concentrator

Terminator

Unit 2

CONCENTRATORS

NETWORK

CONNECTION

Unit 2

Connector to PC serial port

Page 22: Daumar40r English

22 Figure 2

COMPARISON

PROGRAMMING UNIT - CONCENTRATOR

Connection

between

labellers and a

Progrmming

unit Unit 1

Labeller’s

connector

Unit 2

Labeller’s

connector

Unit 3

Labeller’s

connector

Unit n

Labeller’s

connector

Connection

between

labellers and

a concentrator Unit 1

Labeller’s

connector

Unit 2

Labeller’s

connector

Unit 3

Labeller’s

connector

Unit n

Labeller’s

connector

Programming

Unit connector

Concentrator

connector

Page 23: Daumar40r English

23 Figure 3

Concentrator 6

Labellers

From 81 to 96

TABLE

OF

CONCENTRATORS

Concentrator 4

Labellers

From 49 to 64

Concentrator 2

Labellers

From 17 to 32

Concentrator 3

Labellers

From 33 to 48

Concentrator 1

Labellers

From 1 to 16

Concentrator 5

Labellers

From 65 to 80

Page 24: Daumar40r English

24 Figure 4

CONFIGURATION OF

LABELLERS ATTACHED

TO A CONCENTRATOR

Symbol equivalence

Concentrator 1

Labellers

From 1 to 16

Concentrator 2

Labellers

From 17 to 32

Concentrator 3

Labellers

From 33 to 48

Concentrator 4

Labellers

From 49 to 64

Concentrator 5

Labellers

From 65 to 80

Concentrator 6

Labellers

From 81 to 96

01

02

17

18

33

34

49

50

65

66

81

82

03 19 35 51 67 83

04 20 36 52 68 84

05

06

07

08

21

22

23

24

37

38

39

40

53

54

55

56

69

70

71

72

85

86

87

88

11

09

10

27

25

26 42

43

41

58

59

57

74

75

73

90

91

89

12

13

14

28

29

30

44

45

46

60

61

62

76

77

78

92

93

94

15

16

31

32

47 63 79

48 64 80

95

96

Page 25: Daumar40r English

25 Figure 5

EC-40

CONNECTION

Page 26: Daumar40r English

26

EC-40 NETWORK CONNECTIONS

Maximum number

of EC-40 is 32

units.

A terminator must

be placed at the

begining and the

end of the line.

The installation

cable must be

twisted pair

shielded 4 wires.

EC-40 connector

Unit nº 32

EC-40 connector

Unit nº 2

EC-40 connector

Unit nº 1

Terminator

Connector to PC

serial port

Figure 6

Page 27: Daumar40r English

27

Unit 2

Figure 7

NETWORK

CONNECTIONS FROM

XARPA-31 TO EC-40

Twisted

wire

Unit 1

Unit 32

Maximum of 32 units.

A terminator is required at

each end of the line.

Shielded twisted pair wire

must be used.

The first twisted pair will

be 1 & 2.

The second twisted pair

will be 3 & 4.

Serial port PC connection

Terminator

Page 28: Daumar40r English

28

XARPA 31 WITH INTEGRATED CONTROL OF

LABELLING MACHINE EC-40

Once the installation has been carried out as previously described, connect to the control box of the

XARPA-31, which in this case is a circular connector with four contacts (see figure 7).

CONFIGURATION

The number of the labelling machine allocated to the XARPA must be defined and in order to do

this the configuration of the Xarpa must be set. This process is carried out using the screen of the

Xarpa

First of all select option “0”, LABEL, from the main screen of the Xarpa.

The screen referring to the labelling machine will appear and, on the second line, which reads

number of label, press the key sequence 3 8 7 C, and a service menu will appear. Choose option 3

“LOCATION NUMBER”, and the following will appear “N. OF LABELLING M.(01 TO

96):” introduce the desired number and press “M”. Then exit by pressing “C” until the main menu

appears.

NOTE: If you wish to consult the selected location number, on pressing “0” from the main menu,

the first line shows: the location number, the type of labelling machine and the label which has

been memorised.

Concentrator display/EC-40 display.

The display is a device that permits us to check what is going on in the working process.

We have different steps or phases (so the display will show what the situation is):

Page 29: Daumar40r English

29

1.

The display is not showing anything. The display is completely off.

Check if the concentrator/local 40 is correctly connected to the main power.

Check if the primary of the concentrator transformer is receiving 220 V.

Check if there is any fuse blown.

Check if the secondary of the concentrator transformer is giving 11V and 12V,

2.

PC / L-- --.

The display is showing PC or L -– and after a few seconds PC again.

It means that there is no communication between the computer and the concentrator.

-Check if in the computer the Daumar 40 is running.

-Check if the concentrator sliding switches are setup in correct position. (See pag.18 figure 4 to

configure labelers attached to a concentrator).

-Check if the settings of the communication and the allocation are correct. (Make sure that the

number of labeler you configure with the sliding switches in the Circuit board 7033 “local unit”,

is the same as you configure in the allocation option inside the Daumar 40 software.

If you connect more than one labeler, see also page 18 in the Daumar 40 book.

-Check if the converter transformer is correctly connected to the “220V” power supply and

check if the output is 9VDC.Also check if it is connected to the serial port, if necessary we also

send to you an adapter in case you have a 9 pins Com.

-Check if the wires are connected as they should be.

-Check if the “KEY” is correctly connected (must be connected to the parallel port of the

computer).

If you still have the same information on the display screen; you may have some problems in

the computer COM.

To check if there is any problem in the COM, you can use the HYPER TERMINAL.

Page 30: Daumar40r English

30

3.Step 1.

L01,L02,L03...L16 / L17,L18,L19...L32.

The display is showing L 01, after L 02...

Lets say, that when we configure 16 labelers attached to the first concentrator we will see on the

display that the number 01 will be continuously changing until it arrives to number 16 and after

the number 16 the number 01 will reappear and so on.

When this happens, it means that the computer is communicating with the concentrator.

In case of local 40 you see the number of label in memory and when is requesting a label you

see the number changing.

Step 2. REQUESTING LABEL.E 01

The display is showing E 01 when you request one label from the local unit and depending on

the labeller number you will see ”E “and then the number of the labeller.

This means that the concentrator is receiving the request for one label from the Local Unit

(7033).

Step 3.PC IS PREPARING THE LABEL TO BE SENT.R-01.

The display will show “ r 01”.

At this moment you will see that the computer screen is going to change it’s format, showing the

label, but inverted, lets say that now the computer is preparing the label to be sent to the

concentrator.

Sometimes this step is very fast, because the computer did this sometime before, if you request this

label for the first time it takes a little more time.

4. PC IS SENDING THE LABEL. + R01

The display will show you “+ r 01”.

At this moment the computer is sending the label to the concentrator.

The number is the number of labelling machine.

5.CONCENTRATOR IS SENDING THE LABEL TO THE

LOCAL UNIT ( 3PPM). T-01.

The display will show you “ t – 01”.

At this moment the concentrator is sending the label to the local unit “board 7033”.

Only in case concentrator.

Page 31: Daumar40r English

31

Step 1.

The display will show you again the same information as step 3. “L-01...L-02...L-01”

Now the label has been sent OK. And the system is waiting for another label request.

ALARMS:

These steps can be interrupted by an alarm at the end of the process or during it.

The display can show different alarms as follows:

- A01.

PC is not sending labels.

- A02.

Label does not exist.

Will appear at the end of the step 4.

- A03.

Repeat 10 times the same data. It means that the machine has sent the information of the label

10 times but this information has not been completely received from the concentrator.

- A04.

The type of label that the computer sent is not the same as the label machine type.

This means for example that we ask for one label 120 mm/3ppm and the labelling machine is in

an EC-24 160mm/3ppm format.

-A05.

Over-temperature thermal head alarm.

- A00.

The thermal head temperature alarm disappears. (Only in X-31).

- A06.

Communication alarm.

Page 32: Daumar40r English

32

Note:

If for any reason the computer will not communicate with the concentrator, we suggest to

turning off the concentrator, turn off the power for the converter RS485, close the

communications, and after close the allocation: then exit from Daumar 40, restart the computer

and open Daumar 40 again.

In the communication window to close the communication place your mouse on the colon after

“checking labelling” and click the left button.

In the allocation window to close the allocation place the mouse on the colon

after “labeller number” and click the left button.

Page 33: Daumar40r English

33

LOCAL 40 TEST

Options Menu.

Here is the process to select a number:

- Launch the control box while pressing the “request label” button.

- You will see �000" on screen, and then “opt”

- With the keys of hundreds, tens, and units, select the label numbers that you wish and

press the “request label” button.

001= See number of labels.

With key of hundreds select the digits; in units check the value.

1-0, 2-0,3-0, 4-0, 5-0, 6-0, 7-3, 8-7, 9-6.

Number of labels: 000000376

Request label button to exit.

002 = Delete label counter.

003 = Program number of labeller (priority from the hardware).

Enter value with units and tens. (01 - 96).

Request label button to exit.

004 = RAM test.

Tens (-) = Exit from test.

005 = Label Ram test (outside). (Electronic department).

Request label button to exit.

006 = Input test.

See by binary mode all the inputs.

Request label button to exit.

007 = Input test. (Labeller selector or options).

See by binary mode all the inputs.

Request label button to exit.

Page 34: Daumar40r English

34

008 = Output test.

Output selection with hundreds.

Units (+) = to connect.

Units (-) = to disconnect,

Request label button to exit.

009 = See Thermal head temperature.

Request label button to exit.

010 = Com 1Test: (Electronic Department).

Request label button to exit.

011 = Com 2Test:

Request label button to exit.

012 = Thermal head printer lines Test.

Request label button to exit.

013 = Thermal head voltage test ON/OFF.

Request label button to exit.

014 = (T1). Delay start cutting.

Request label button to exit.

015 = (T2). Cutting time.

Request label button to exit.

016 = (T3). Finger turning Time.

Request label button to exit.

017 = (T4). Delay starts the translation.

Request label button to exit.

018 = (T5). Translation time.

Request label button to exit.

019 = (T6). Delay between stop the motor and reverse the direction.

Request label button to exit.

020 = (T7). Reversing time motor. (Stopping).

Request label button to exit.

Page 35: Daumar40r English

35

EC-40 Times.

Xarpa- 31

C-387 + label

EC-40 (160 mm.). EC_40 (120 mm.) EC-24 (160-120)

T-1: 0 0 0

T-2: cutting.

70 90 250

T-3: finger

movement.

250 400 0

T-4: delay translation.

150 150 0

T-5: translation time. 150 300 0

T-6: delay between

the stopping of the

motor and the

reversion

050 050 0

T-7: 036-reversion

time of the motor

036 036 0

LEA 80

T-1: label pusher time 300

T-2: vacuum time 250

T-3: delay vacuum 300

T-4: delay start label 0

T-5 delay label movement 0

Page 36: Daumar40r English

36

CEA 44.

CS-28 CB-34

T-1: label pusher time 500 300

T-2: vacuum time 500 500

T-3: delay start label pusher 300 0

T-4: delay begins to print 20 40

T-5 delay start vacuum 200 200

LOCAL 40 TEST

Options Menu.

Here is the process to select a number:

- Launch the control box while pressing the “request label” button.

- You will see �000" on screen, and then “opt”

- With the keys of hundreds, tens, and units, select the label numbers that you

wish and press the “request label” button.

001= See number of labels.

With key of hundreds select the digits; in units check the value.

1-0, 2-0,3-0, 4-0, 5-0, 6-0, 7-3, 8-7, 9-6.

Number of labels: 000000376

Request label button to exit.

002 = Delete label counter.

003 = Program number of labeler (priority from the hardware).

Enter value with units and tens. (01 - 96).

Request label button to exit.

004 = RAM test.

Tens (-) = Exit from test.

Page 37: Daumar40r English

37

005 = Label Ram test (outside). (Electronic department).

Request label button to exit.

006 = Input test.

See by binary mode all the inputs.

Request label button to exit.

007 = Input test. (Labeller selector or options).

See by binary mode all the inputs.

Request label button to exit.

008 = Output test.

Output selection with hundreds

Units (+) = to connect.

Units (-) = to disconnect,

Output n-2 vacuum.

Output n-3 pusher.

Output n-4 motor.

Request label button to exit.

009 = See Thermal head temperature.

Request label button to exit.

010 = Com 1Test: (Electronic Department).

Request label button to exit.

011 = Com 2Test:

Request label button to exit.

012 = Thermal head printer lines Test.

Request label button to exit.

013 = Thermal head voltage test ON/OFF.

Request label button to exit.

014 = (T1). T-1: label pusher time

Request label button to exit.

015 = (T2). T-2: vacuum time

Request label button to exit.

016 = (T3). T-3: delay start label pusher

Request label button to exit.

Page 38: Daumar40r English

38

017 = (T4). T-4: delay begins to print.

Request label button to exit.

018 = (T5). T-5 delay starts the vacuum.

Request label button to exit.

019 = (T6). Free

Request label button to exit.

020 = (T7). Free.

Request label button to exit.

Page 39: Daumar40r English

39

Gircod labels

A

B

Gircod 1 :

3 ppm : A= 40 mm. B=50.6 mm.

8 ppm : A= 43.25 mm. B=54.75 mm.

Gircod 2 :

3 ppm : A= 40 mm. B=53.3 mm.

8 ppm : A= 43.25 mm. B=56 mm.

Gircod 3 :

3 ppm : A= 64 mm. B=53.3 mm.

8 ppm : A=69.12 mm. B=56 mm.