Datasheet Filters for C2000 Family Version2...
Transcript of Datasheet Filters for C2000 Family Version2...
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC. 1 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Datasheet Filters for C2000 Family Version2 Feb2015.docx
Built-in filter overview for C/CP2000 The built-in filters of C/CP2000 have been modified.
This modification went in production in 2015 WK01.
Now these drives also comply with Class C2 with shielded motor cables, both Conducted Emission and Radiated
Emission.
External option filters for C/CP2000 • The input and output zero phase reactors are mandatory to comply with the radiated emission levels, as is the use of
a shielded motor cable.
• Connection example:
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 2 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
External option filter overview for C2000
For Class C1 Radiated Emission the drive needs to be installed in a shielded cabinet
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 3 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
External option filter overview for CP2000
** For Class C1 Radiated Emission the drive needs to be installed in a shielded cabinet
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 4 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Common data KMF/MIF filterss
Mains voltage VAC KMF: 500VAC +10% max MIF: 480VAC +10% max
Mains frequency Hz 50 ~ 60Hz ±1%
Operating temperature °C KMF: -25 ~ +100°C MIF: -25 ~ +90°C
Atmospheric pressure kPa 86 ~ 106kPa
Relative humidity % ≤90% (non condensing)
Vibration KMF: 10~200Hz: 1.8G MIF: 10~150Hz: 10m/s
2
Degree of protection KMF: IP20 Approvals CE, UL, RoHS
Common data EMF filterss Mains voltage VAC tbd Mains frequency Hz 50 ~ 60Hz Operating temperature °C tbd Atmospheric pressure kPa 86 ~ 106kPa
Relative humidity % ≤90% (non condensing) Vibration tbd Degree of protection tbd Approvals tbd: CE, UL, RoHS
Common data B84143 filterss
Mains voltage VAC R127: 520/300VAC S020: 530/310VAC
Mains frequency Hz 50 ~ 60Hz Operating temperature °C -25 ~ +100°C
Relative humidity % ≤90% (non condensing) Degree of protection R127: IP20 Approvals CE, UL, RoHS
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 5 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Sizes and dimensions in mm
EMF021A23A EMF014A43A
Weight 1.6kg Power
dissipation tbd
Terminal wire section
tbd
Dimensions LxWxH in mm
270x87x70
Mounting 4x M5
EMF018A43A Weight 1.8kg Power
dissipation tbd
Terminal wire section
tbd
Dimensions LxWxH in mm
275x109x70
Mounting 4x M5
EMF056A23A EMF039A43A
Weight 4kg Power
dissipation tbd
Terminal wire section
tbd
Dimensions LxWxH in mm
390x155x80
Mounting 4x M5
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 6 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
KMF370A KMF3100A
Weight 4.1kg Power
dissipation 19W (KMF370) 18W (KMF3100)
Terminal wire section
50mm2
Dimensions LxWxH in mm
312x94x190
Mounting 4x M6 Earth studs M8
MIF3400B Weight 22kg Power
dissipation 43W
Terminals M12 Dimensions
LxWxH in mm 873x420x110
Mounting 4x M6 Earth studs M10
MIF3800 Weight 30kg Power
dissipation 15W
Terminals M12 Dimensions
LxWxH in mm 625x420x220
Mounting 4x M6 Earth studs M10
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 7 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
B84143D0150R127 Weight 17kg
Protection IP20 Terminals 95mm
2
Dimensions LxWxH in mm
479x125x226
Mounting 4x M6 Earth studs M10
B84143D0200R127 Weight 18.5kg
Protection IP20 Terminals 95mm
2
Dimensions LxWxH in mm
542x195x259
Mounting 4x M6 Earth studs M10
B84143B0250S020 Weight 15kg
Terminals M10 (11mmØ) Dimensions
LxWxH in mm 390x190x115
Mounting 6x M12 Earth studs M10
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 8 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
B84143B0400S020 Weight 21kg
Terminals M10 (11mmØ) Dimensions
LxWxH in mm 390x260x116
Mounting 6x M12 Earth studs M10
RF008X00A RF004X00A A 98 A 110 B 73 B 87.5 C 36.5 C 43.5 D 29 D 36 E 56.5 E 53 F 86 F 96
GØ 5.5 GØ 5.5
RF002X00A A 200 B 172.5 C 90 D 78 E 55.5 F 184
GØ 5.5 H 22
RF300X00A A 241 B 217 C 114 D 155 E 42 F 220
GØ 6.5 H 7 I 20
AD
CB
E
G
F
D
BC
E
F
H
G
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 9 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Standards To comply with the European EMC Directive 89/336/EEC, Power Drive Systems (PDS) have to fulfil the requirements of the product standard EN61800-3 2004 Adjustable speed electrical power drive systems, Part 3: EMC Products Standard Including Specific Test Methods. These requirements are necessary and sufficient; no additional EMC tests are required. Environments In standard EN61800-3 two environments are defined: 1
st Environment: Household or Domestic. It includes domestic premises and establishments
directly connected without intermediate transformers to a low-voltage power supply network, which supplies buildings used for domestic purposes. In the 1
st Environment difference is made between restricted and unrestricted
distribution. Restricted distribution means that products are sold to EMC competent users. Unrestricted distribution means that products are sold to non-EMC competent users (e.g. consumers). AC Motor Drives never fall in the unrestricted distribution class!
2
nd Environment: Industrial. All other establishments.
(Between 1st and 2nd Environment there is always at least one mains power transformer) In the 2
nd Environment difference is made for conducted emission for AC Motor
Drives with mains current >100A and ≤100A. Classes With the latest version of the standard EN61800-3 2004, classes for PDS are defined. 1
st Environment unrestricted: Class C1 (seldom used for AC Motor Drives)
1
st Environment restricted: Class C2
2nd
Environment ≤100A: Class C3 >100A: Class C3 The following classes are defined but outside the scope of the filters and this datasheet.
2nd
Environment: Class C4 (special for PDS with rated voltage ≥1000V, rated current ≥400A or special circumstances.
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 10 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Below you’ll find a table and a plot of the conducted emission levels for the defined classes. Although the levels in EN61800-3 2004 are equal to those in EN55011 and EN55022, these latter are only used for reference for measuring methods, etc.
Conducted Emission (QP)
Industrial Domestic
EN61800-3 2004 C4 Special >400A C3 2nd Env. >100A C3 2nd Env. <100A C2 1st Env. Restr. C1 1st Env. Unrestr.
EN61800-3/A11 - 2nd Env. >100A 2nd Env. <100A 1st Env. Restricted 1st Env. Unrestricted
EN55011 - Class A Gr.2 >100A Class A Gr.2 <100A Class A Gr.1 Class B
EN55022 - - - Class A Class B
MHz dBµV (QP)
Series 9 1 2 3 4
0.15 79 130 100 79 66
0.5 79 130 100 79 56
0.5 73 125 86 73 56
5 73 125 86 73 56
5 73 115 90 73 60
30 73 115 70 73 60
(AV: -13dBµV) (AV: -10dBµV) (AV: -10dBµV) (AV: -13dBµV) (AV: -10dBµV)
0
20
40
60
80
100
120
140
0.1 1 10 100
dB
uV
MHz
Conducted emission QP
Series1
Series2
Series3
Series4
Series 9
Datasheet Filters for C2000 Family
DELTA ELECTRONICS, INC 11 Delta reserves the right to make
ALL RIGHTS RESERVED changes without prior notice
Radiated Emission (QP)
Industrial Domestic
EN61800-3 2004 C4 Special >400A C3 2nd Env. >100A C3 2nd Env. <100A C2 1st Env. Restr. C1 1st Env. Unrestr.
EN61800-3/A11 - 2nd Env. >100A 2nd Env. <100A 1st Env. Restricted 1st Env. Unrestricted
EN55011 - Class A Gr.2 >100A Class A Gr.2 <100A Class A Gr.1 Class B
EN55022 - - - Class A Class B
MHz dBµV (QP)
Series 10 5 6 7 8
30 30 50 50 40 30
230 30 50 50 40 30
230 37 60 60 47 37
1000 37 60 60 47 37
@30m @10m @10m @10m @10m
or +10dBµV @3m
www.delta-emea.com
0
10
20
30
40
50
60
10 100 1000
dB
uV
MHz
Radiated emission QP
Series 5
Series 6
Series 7
Series 8
Series 10