www.atriumdata.com
54 Avenue Hoche - 75008 Paris Contact
Thierry DUFLOS Cel : +33 6 50 37 98 46
IMPROVING DATACENTERS PERFORMANCES ATRIUM DATA’S SOLUTIONS
Main activities :
Consulting : Audits :Datacenter Strategy, Technical surveyBusiness Models, Continuity of ServiceBusiness plan, and Audits Risk AnalysisContract assistance Energy efficiency… - …
R&D programs :
Datacenter performances,Energy Efficiency, Costs saving
11/04/2023
11/04/2023 3
Research & Development Programs
Existing Datacenters’ Energy Efficiency & Reliability improvement, New Datacenters’ Performances, Energy Efficiency and Reliability improvement
AuditsConsulting missionsOwn experience
AssessmentsCustomer’s expectations
Goals R&D Programs
1 2 3 4
Solutions
5
Our approach
YESTERDAY TODAY
ACHIEVEMENTS TO DATEWhere we are
11/04/2023 5
Performances we are able to propose
PUE below 1.1, Calculated using meteorological data from 2003,
PUE Effective day one PUE is totally independent of the datacenter load,
Very High Density Up to 30/35 kW IT per rack (12 kW IT / sqm),
Building design to meet maximum Air flow cooling capacity,
11/04/2023 6
Performances we are able to propose
Multi Tiering Architecture for power distribution,Tiering level can be different rack per rack accordingly to real needs?
Solution independent from technology and/or manufacturers,
Significant costs reduction,Investments by 20 % (Based on our first tender won)Running cost (Due to PUE performance and characteristic – effective day one)
11/04/2023 7
Achievement to date
Two Patents with international coverage With others ongoing R&D programs
Industrial partnership agreement To be able to propose key turn contract to main organizations To accelerate our development in France To develop International,
Our First project had been elected to “ Investissements d’Avenir” French government program for IT innovation
First contract signed Signed in June for 400 m² Datacenter with performance commitment on PUE
Option Tier IIITGHQ-A1N1
TGHQ Tier IV A1S
160 kW Utiles
INVTD-servitudes
- DI – - Intrusion - - Eclairage -
- Détection eau -
(dont UPS éclairage secours – 6 kW)
TGHQ-A1S1
480 kW (S)
TR A1 N(1250 kVA)
TGBT A1N TGBT A1S
480 kW
TDHQ A1-N1-1
TDHQ A1-N1-2
TDHQ A1-N1-3
TDHQ A1-S1-1
TDHQ A1-S1-2
TDHQ A1-S1-3
TDHQ A1-S1-4
TGHQ-Tier IV A1N
160 kW Utiles
TR A1S(1250 kVA)
UPS 3 x160 kW
TD Tier III A1N (A) TD Tier III A1S (A)
(Tier III) (Tier III)
(Tier III) (Tier III)
(Tier III+) (Tier III+)
(Tier IV) (Tier IV)
Charge IT 120 kW
Charge IT 120 KW
Charge IT 120 kW
Charge IT 120 kW
Telco AVoie A1
Telco BVoie A1
Telco AVoie B1
Telco BVoie B1
Charge IT 120 kW Charge IT 120 kW
Charge IT 64 kW
Charge IT 64 kW
60 kW 60 kW
60 kW 60 kW
60 kW 60 kW
(maximum 970 kW soit 1210 KVA)
24 départs 32 A TETRA non équipés
TD A1N - Tier IV
6 départs 32 A mono (4 kW / Pt)
UPS160 kW
UPS160 kW
INVLocal Pompes
- Pompes -Adoucisseur d’eau
EclairageDivers climatisation
Local techniqueGalerie Voie A
Local techniqueGalerie Voie B
GF DAIKIN N° 01EWAD510DXR
GF DAIKIN N° 02EWAD510DXR
Charge IT 120 kW
(maximum 970 kW soit 1210 KVA)
Phase
II
120 kW
120 kW
120 kW
120 kW
20 kW
20 kW20 kW
20 kW
120 kW
120 kW
120 kW
120 kW
120 kW
120 kW120 kW
GEArmoire de couplage Tier III
800 kVA
TD Tier III A1N (B) TD Tier III A1S (B)120 kW120 kW
120 kW
120 kW120 kW
120 kW
12 départs 32 A mono (4 kW / Pt)
Telco BVoie A2
Telco AVoie A2
Telco BVoie B2
Telco BVoie B2
6 départs 32 A mono (4 kW / Pt)
12 départs 32 A mono (4 kW / Pt)
44 kW
44 kW
44 kW
44 kW
Phase
II
Phase
IIPhas
e II
Phase
II
Phase
II
Phase
II
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
24 départs 32 A TETRA non équipés
34 départs 32 A triphasés non équipés
160 kW 160 kW
Phase
II
Phase
II
24 départs 32 A TETRA non équipés 24 départs 32 A TETRA non équipés
34 départs 32 A triphasés non équipés34 départs 32 A triphasés non équipés
GEGEGE
800 kVA 800 kVA800 kVAPhas
e II
Phase
II
CDSTGA1-NTGA2-N
CDS CDS CDS
TGHQ A1-N1TGHQ A2-N1 TG
HQ
A1
S T
ier IV
Armoire de couplage(Tier III)
TG
HQ
A2
N T
ier IV
TR
A
2 N TR
A
1 N TR
A
1 S TR
A
2 S
UP
S
A2N
UP
S
A2
N
Batt. A
2N
Batt A
2N
Cp
lU
PS
A
2N
UP
S
A2N
Batt. A
2N
Batt A
2N
UP
S
A1
N
UP
S
A1N
Bat
t. A
1N
Bat
t A
1N
UP
S
A1N
UP
S
A1N
Bat
t. A
1N
Bat
t A
1N
Cp
l
TGA2-STGA1-S
TGHQ A2-S1TGHQ A1-S1 TG
HQ
A2
S T
ier IV
TG
HQ
A1
S T
ier IV
UP
S
A2S
UP
S
A2S
Batt. A
2S
Batt A
2SC
pl
UP
S
A2S
UP
S
A2
S
Batt. A
2S
Batt A
2S
UP
S
A1S
UP
S
A1S
Bat
t. A
1S
Bat
t A
1S
UP
S
A1
S
UP
S
A1S
Bat
t. A
1S
Bat
t A
1S
Cp
l
UP
S
TIE
R
IVA
1S
Batt A
1S
UP
S
TIE
R
IV A1N
Bat
t A
1S
UP
S
TIE
R
IVA
2S
Batt A
2S
UP
S
TIE
R
IV A2N
Bat
t A
2N
TG
BT
GE
80
0 k
VA
TD
Se
rvitud
es
14 14 14 14
10106
14 14
10
12 12
14 10
11/04/2023 8
Our program elected to “Investissements d’Avenir”
11/04/2023 9
Thanks for your attention.Let’s discuss later on if you want to learn more about us…