DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator...

7
AMPERE RATING(A) RATED CURRENT (max) [I n ](A) JIS ,IEC, EN, AS NEMA, ANSI Marine NEUTRAL POLE AMPERES FRAME (A) NUMBER OF POLES RATED PRIMARY CURRENT OF OVER–CURRENT RELEASE [I CT ](A) • for general feeder circuit use RATED CURRENT OF OVER–CURRENT RELEASE(A) • for generator protection use [I n ] is generator rated current. AC RATED INSULATION VOLTAGE [U i ](V. 50/60Hz) RATED OPERATIONAL VOLTAGE [U e ](V. 50/60Hz) AC RATED BREAKING CAP [kA sym rms) MAKING CAPACITY [kA peak] AC 690V [I cs = I cu V 0 4 4 ] V 5 3 6 C A A M E N V 8 0 5 I S N A 254V DC 600V 250V NK AC 690V 450V LR, AB, AC 690V V 0 5 4 V B , L G RATED IMPULSE WITHSTAND VOLTAGE [ U imp](kV) RATED SHORT TIME WITHSTAND 1s CURRENT[I cw s 3 ] s m r A k [ ] LATCHING CURRENT (kA) TOTAL BREAKING TIME (s) CLOSING OPERATION TIME SPRING CHARGING TIME (s) max. CLOSE TIME (s) max. No. of operating cycles Mechanical life with maintenance without maintenance Electrical life without maintenance AC460V AC690V Draw-Out Body (kg) Draw-Out Chassis (kg) Total Draw-Out Weight (kg) Fixed (kg) OUTLINE DIMENSION (mm) a E P Y T D E X I F b c d a T U O - W A R D TYPE b c d 2500 Types: AR325S, AR332S, Electrical Characteristics to IEC 609847-1, IEC 60947-2 Series 2500 2500 2500 2500 3 4 2500 1250 I n 2500 1000 690 65/143 85/187 50/115 65/149.5 85/195.5 40/40 40/40 65/153 85/201 65/153 85/201 12 85 65 85 0.03 10 0.08 20000 10000 7000 5000 56 68 49 57 105 125 80 92 466 586 460 290 75 460 580 460 345 40 Standard 3200 AR332S 3200 3200 3200 3200 3 4 3200 1000 690 65/143 85/187 50/115 65/149.5 85/195.5 40/40 40/40 65/153 85/201 65/153 85/201 12 85 65 85 0.03 10 0.08 20000 10000 7000 5000 56 68 49 57 105 125 80 92 466 586 460 290 75 460 580 460 345 40 : Values in open air at 40°C (45°C for marine applications). : Values of AR208S, AR212S, AR216S for draw-out type with horizontal ter- minals, Values of the other ACBs for draw-out type with vertical terminals. : For 2 pole ACBs use outside poles of 3 pole ACB. : 4poles ACBs without Neutral phases protection can not apply IT earthing system. : Contact TERASAKI for the details. : For 500V AC. : ARG OCRs can not be used for DC. Please contact TERASAKI for DC application. : A special version of the ACB is required above 250V DC. Contact Terasaki for details. Applicable to only 3 pole ACBs. For vertical terminals or horizontal terminals. These weights are based on normal specifications with the OCR and standard accessories Comply with JIS C 8201-2-1 Ann.1 Ann.2 Being or will be applied. Values for ACBs with INST. 100/220kA for ACBs with MCR. # : Contact TERASAKI for the ratings. Note: When the INST trip function is set to NON, the MCR function should be enabled, otherwise, the rated breaking capacity is reduced to the rated latching current. a c d b a c d b 1 2 3 4 5 6 7 8 1 2 11 12 14 13 9 10 6 6 6 6 6 6 5 7 8 3 4 9 9 11 11 11 11 12 12 = < : : : : : : Page 1 of 7 DATA SHEET: TEMPOWER2 ACB Type AR325S Standard < = < = 1600 I n 3200 < = JIS IEC, EN, AS 10

Transcript of DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator...

Page 1: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

AMPERE RATING(A)

RATED CURRENT (max) [In](A) JIS ,IEC, EN, AS NEMA, ANSI

MarineNEUTRAL POLE AMPERES FRAME (A)NUMBER OF POLESRATED PRIMARY CURRENT OF OVER–CURRENTRELEASE [ICT](A)• for general feeder circuit use

RATED CURRENT OF OVER–CURRENT RELEASE(A)• for generator protection use[In] is generator rated current.

AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz)RATED OPERATIONAL VOLTAGE [Ue](V. 50/60Hz)AC RATED BREAKING CAP [kA sym rms) MAKING CAPACITY [kA peak]

AC 690V [Ics= Icu V044]

V536CAAMENV805ISNA

254VDC 600V

250VNK AC 690V

450VLR, AB, AC 690V

V054VB ,LG

RATED IMPULSE WITHSTAND VOLTAGE [Uimp](kV)RATED SHORT TIME WITHSTAND 1sCURRENT[Icw s3]smr Ak[]LATCHING CURRENT (kA)TOTAL BREAKING TIME (s)CLOSING OPERATION TIMESPRING CHARGING TIME (s) max.CLOSE TIME (s) max.No. of operating cycles Mechanical life with maintenance

without maintenance Electrical life without maintenance AC460V

AC690VDraw-Out Body (kg)Draw-Out Chassis (kg)Total Draw-Out Weight (kg)Fixed (kg)OUTLINE DIMENSION (mm)

aEPYT DEXIFbcdaTUO-WARD

TYPE bcd

2500

Types: AR325S, AR332S,

Electrical Characteristics to IEC 609847-1, IEC 60947-2

Series

25002500250025003 42500

1250 In 2500

1000690

65/14385/187 50/11565/149.585/195.540/4040/4065/15385/201 65/15385/201

128565850.03

100.08

20000100007000500056 6849 57105 12580 92

466 58646029075460 58046034540

Standard3200

AR332S

32003200320032003 43200

1000690

65/14385/187 50/11565/149.585/195.540/4040/4065/15385/201 65/15385/201

128565850.03

100.08

20000100007000500056 6849 57105 12580 92

466 58646029075460 58046034540

: Values in open air at 40°C (45°C for marine applications).: Values of AR208S, AR212S, AR216S for draw-out type with horizontal ter-minals, Values of the other ACBs for draw-out type with vertical terminals.

: For 2 pole ACBs use outside poles of 3 pole ACB.: 4poles ACBs without Neutral phases protection can not apply IT earthingsystem.

: Contact TERASAKI for the details.: For 500V AC.: ARG OCRs can not be used for DC. Please contact TERASAKI for DCapplication.

: A special version of the ACB is required above 250V DC. ContactTerasaki for details.

Applicable to only 3 pole ACBs.For vertical terminals or horizontal terminals.

These weights are based on normal specifications with the OCR and standard accessories

Comply with JIS C 8201-2-1 Ann.1 Ann.2 Being or will be applied.Values for ACBs with INST. 100/220kA for ACBs with MCR.

# : Contact TERASAKI for the ratings.Note: When the INST trip function is set to NON, the MCR function should be

enabled, otherwise, the rated breaking capacity is reduced to the ratedlatching current.

a c d

b

a c d

b

1 2

3

4

5

6

7

8

1

2 11

12

14

13

9

10

6 6

6 6

6 6

5

7 8

3 4

9

9

11

11

11 11

12

12

=<

:::

:::

Page 1 of 7

DATA SHEET: TEMPOWER2 ACB

Type AR325SStandard

<= <=1600 In 3200<=

JIS IEC, EN, AS

10

Page 2: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

Adjustable long time-delay trip characteristics

Pick-up current [IR] (A)

Time-delay [tR] (s)Time-delay setting tolerance (%)

Adjustable short time-delay trip characteristics

Pick-up current [Isd] (A)Current setting tolerance (%)Time-delay [tsd] (ms) Relay time

Resettable time (ms)Max. total clearing time (ms)

Adjustable instantaneous trip characteristics or (For AGR-11B, INST only)

Pick-up current [I i] (A)Current setting tolerance (%)

Adjustable pre-trip alarm characteristics

Pick-up current [IP1] (A)Current setting tolerance (%)Time-delay [tP1] (s)Time-delay setting tolerance (%)

Adjustable ground fault trip characteristics

Pick-up current [Ig] (A)Current setting tolerance (%)Time-delay [tg] (ms) Relay time

Resettable time (ms)Max. total clearing time (ms)

Ground fault trip characteristics on line side(AGR-21B, 31B only)

Pick-up current [IREF] (A)current setting tolerance (%)Time-delay (s)

N-phase protection characteristics

Pick-up current [IN] (A)

Time-delay [tN] (s)Time-delay setting tolerance (%)

Phase rotation protection characteristics(AGR-21B, 31B only)

Pick-up current [INS] (A)current setting tolerance (%)Time-delay [tNS] (s)Time-delay setting tolerance (%)

Adjustable earth leakage trip characteristics(AGR-31B only)

Pick-up current [IΔR] (A)Current setting toleranceTime-delay [tΔR] (ms) Relay time

Resettable time (ms)Max. total clearing time (ms)

Undervoltage alarm characteristics(AGR-31B only)

Recovery setting voltage (V)Recovery voltage setting tolerance (%)Setting voltage (V)Voltage setting tolerance (%)Time-delay (s)Time-delay setting tolerance (%)

Control power

Types: AR325S, AR332S

L-characteristic for general feeder circuits (Type AGR-11BL, 21BL, 31BL)

Protection functions

Setting range of protection functionsSetting range

LT

ST

INST MCR

PTA

GF

NP

ELT

[In]~(0.8 – 0.85 – 0.9 – 0.95 – 1.0 – NON) ; 6 graduations• Non tripping when load current Ö ([IR]~1.05). • Tripping when ([IR]~1.05) É load current Ö ([IR]~1.2)(0.5 – 1.25 – 2.5 – 5 – 10 – 15 – 20 – 25 – 30) at 600% of [IR]; 9 graduations±15% +150ms – 0ms

[In]~(1 – 1.5 – 2 – 2.5 – 3 – 4 – 6 – 8 – 10 – NON) ; 10 graduations±15%

50 100 200 400 600 800 ; 6 graduations25 75 175 375 575 775

120 170 270 470 670 870

[In]~(2 – 4 – 6 – 8 – 10 – 12 – 14 – 16 – NON) ; 9 graduations±20%

[In]~(0.75 – 0.8 – 0.85 – 0.9 – 0.95 – 1.0) ; 6 graduations±7.5%(5 – 10 – 15 – 20 – 40 – 60 – 80 – 120 – 160 – 200) at [IP1] or more; 10 graduations±15% +100ms – 0ms

Note: Set [Ig] to 1200A or less.[ICT]~(0.1 – 0.2 – 0.3 – 0.4 – 0.6 – 0.8 – 1.0 – NON) ; 8 graduations±20%100 200 300 500 1000 2000 ; 6 graduations75 175 275 475 975 1975

170 270 370 570 1070 2070

[ICT]~(0.1 – 0.2 – 0.3 – 0.4 – 0.6 – 0.8 – 1.0 – NON) ; 8 graduations±20%Inst

[ICT]~(0.4 – 0.5 – 0.63 – 0.8 – 1.0) ; Factory set to a user-specified value for AGR-11BL.• Non tripping when load current Ö ([IN]~1.05). • Tripping when ([IN]~1.05) É load current Ö ([IN]~1.2)Tripping at 600% of [IN] with LT time-delay [tR]±15% +150ms – 0ms

[In]~(0.2 – 0.3 – 0.4 – 0.5 – 0.6 – 0.7 – 0.8 – 0.9 – 1.0) ; 9 graduations±10%(0.4 – 0.8 – 1.2 – 1.6 – 2 – 2.4 – 2.8 – 3.2 – 3.6 – 4) at 150% of [INS] ; 10 graduations±20% +150ms – 0ms

0.2 – 0.3 – 0.5 (Medium sensitivity) or 1 – 2 – 3 – 5 – 10 (Low sensitivity)Non operate below 70% of [IΔR], Operate between 70% and 100% of [IΔR].100 150 300 500 800 1500 3000 ; 7 graduations50 100 250 450 750 1450 2950

250 300 450 650 950 1650 3150

[Vn]~(0.8 – 0.85 – 0.9 – 0.95) ; 4 graduations±5%[Vn]~(0.4 – 0.6 – 0.8) ; 3 graduations±5%0.1 – 0.5 – 1 – 2 – 5 – 10 – 15 – 20 – 30 – 36 ; 10 graduations±15% +100ms–0msAC100 – 120V

CommonDC100 – 125V

CommonDC24V

CommonAC200 – 240V DC200 – 250V DC48VPower consumption: 5 VA

⎞⎠

⎞⎠

⎞⎠

__ : Default setting

REF

NS

UV

Specifications

Page 2 of 7

DATA SHEET: TEMPOWER2 ACB

Page 3: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

Values of [ICT] and [In]Type Applicable Rated current [In](A)

[ICT] [ICT] [ICT] [ICT] [ICT](A) ~0.5 ~0.63 ~0.8 ~1.0

AR325S 2500

1600 2000 2500 3200AR332S 3200

Ope

rati

ng t

ime

seco

nd

min

ute

ho

ur

0 . 0 0 6

0 . 0 1

0 . 0 2

0 . 0 4

0 . 0 6

0 . 1

0 . 2

0 . 4

0 . 6

1

2

4

6

1 0

2 0

4 0

1

2

4

6

1 0

2 0

4 0

1

2

3

87 9 10 15 20 30 40 50 60 70 80 90 100

150

200

% of OCR rated primary current [ ]ICT

N-phase protection current setting range

GF current setting range

80 907060 100

150

125

250

200

300

400

500

600

700

800

900

1000

1500

2000

3000

2500

INST current setting range

Max

400ms

100ms

800ms

Min. The ST trip characteristic shown in the figure applies when the ramp characteristicselect switch is in the OFF position.

% o f r a t e d c u r r e n t [ ]In

LT current setting range

PTA current setting range

ST current setting range

PROTECTION CHARACTERISTICS

Page 3 of 7

Types: AR325S, AR332S

L-characteristic for general feeder circuits (Type AGR-11BL, 21BL, 31BL)

Specifications

DATA SHEET: TEMPOWER2 ACB

1250 1600 2000 2500

Page 4: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

405

20

335

¶2

30

216

PC

PC

216(3P)336(4P)

230 230(3P)

329

460

490

33

350(4P)

293 293(3P)413(4P)

60

50

172.5 172.5(3P)

141

94

4-ø14

292.5(4P)

238

500

257 257(3P)

N

377(4P)

250

R116

211.5(3P)331.5(4P)

211.5rear panel cut

front panel cut

panel cutout

Mounting holes

Maintenancespace

For fitted withbreaker fixing bolts

draw-out handle

Maintenancespace

Maintenancespace

CP: ACB Front cover center line

¶1: Conductors including connecting bolts should beseparated min. 7mm from Draw-out arm.

¶2: Panel cut should be 339 mm not 335 mm when the doorflange is used. Refer to page 41.

• N represents the neutral pole of 4-pole ACBs.The neutral pole is positioned to the right as standard whenviewed from the front of the ACB. However, the neutral polecan be customized so that it is positioned to the left.

• For type AR-H high fault series, vertical terminals arestandard, horizontal terminals are optional and frontconnections are not available.

• The vertical terminal for the main circuit with its lengthextended by 70 mm from the standard is specially availableon request.

• For the outline drawing for the version with earth leakagetripping, contact us.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

DATA SHEET: TEMPOWER2 ACB Types: AR325S, AR332S

Drawout Type Outline Dimensions

Page 4 of 7

Page 5: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

53-ø11 N 130 130 130

35 Front connections

83

11.5 25 25 21.5 28 25 25 10

25 10 28 21.5 11.5

318 25 25 25 25

88 83380

Control circuit terminal cover(optional)

CP

N 514 21

130 130 130199

15

1220 Vertical terminals 65

17 4-ø11

¶ 1

99494 141 110 33

345 40 20385 197.5(3P)

35 conductor overlap. max 317.5(4P)CP

15N 5

130 130 130

3-ø11

Horizontal terminals

Draw-out arm(comes out when breaker is drawn out)385

M8 screwearth terminal

2-ø20Lifting hole

35 conductor overlap. max

18

3015

1512

.512

.512

.512

.565

515

2525

2525

2525

2525

148

154

30

8010

016

512

010

0

cond

ucto

r ove

rlap.

max

cond

ucto

r ove

rlap.

max

3535

4015

15

2548

.5

88

265

PC

ON-OFF button cover

CONNECTED position

TEST position

ISOLATED position

DATA SHEET: TEMPOWER2 ACB Types: AR325S, AR332S

Drawout Type Outline Dimensions

Page 3 of 7Page 3 of 7

Page 5 of 7

Page 6: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

CP

N

261

CP228 228(3P)

348(4P)

N

238

261 (3P)381 (4P)

100

550

3332

930

5.5

27

490

460

550

(Arc

spa

ce)

233

353(4P)233(3P)

217.5 217.5(3P)

337.5(4P)

165

82

4-ø14

293413(4P)293(3P)

30250

335

¶2

PC

Front panel cut

Maintenance space

Panel cutout

Mounting holes¶2: Panel cut should be 339 mm not 335 mm when the doorflange is used. Refer to page 41.

• N represents the neutral pole of 4-pole ACBs.The neutral pole is positioned to the right as standard whenviewed from the front of the ACB. However, the neutral polecan be customized so that it is positioned to the left.

• For type AR-H high fault series, vertical terminals arestandard, horizontal terminals are optional and frontconnections are not available.

• For the outline drawing for the version with earth leakagetripping, contact us.

DATA SHEET: TEMPOWER2 ACB Types: AR325S, AR332S

Fixed Type Outline Dimensions

Page 6 of 7

Page 7: DATA SHEET: TEMPOWER2 ACB - Terasaki Data... · • for generator protection use [In] is generator rated current. AC RATED INSULATION VOLTAGE [Ui](V. 50/60Hz) RATED OPERATIONAL VOLTAGE

CP5

N 130 130 130 3-ø11

227 6

37 100 28 34 10 28 21.5 11.5Main terminal

82 165 58 25 10.5 25 25 11.5 21.5 25 25 28 10

305 88 25 25 83 25 2583 88

102 165241

199

35 CPN 5

15 130 130 130

hole

12Vertical terminals

17

9

26720

Panel 82 165 118 earth terminal365

35 Conductor overlap max.15

3-ø11CP

N 5

130 130 130

Horizontal terminals

82 165 118

365

Maintenance space

ON-OFFbutton cover 241 (3P)

361 (4P)

2-ø20Lifting

4-ø11

M8 screw

Control circuit terminal cover (optional)Conductor overlap max.

mounting hole ø14

Front connections

3332

9

18

35

148

154

3015

2525

1512

.512

.512

.512

.580

2525

2525

2525

6551

5

100

120

100

165

580

305.

5

15

35Co

nduc

tor o

verla

p m

ax.

DATA SHEET: TEMPOWER2 ACB Types: AR325S, AR332S

Fixed Type Outline Dimensions

Page 4 of 7Page 4 of 7

Page 7 of 7