The Quality Connection
High Speed Cables
or Enterprise Data Solutions
Business Unit Telecom
-
7/28/2019 data cables with drawings and charts
2/16
Enterprise Data Solutions (EDS)
The escalating Internet data trac has stimulated anunprecedented growth in the communication data center
inrastructure. Higher bandwidth networking protocols
such as Ethernet and InniBand are evolving rapidly to
support data rates o 40/100 Gb/s and 120 Gb/s respec-
tively. Signicant changes in storage area networking
(SAN) and high perormance computing (HPC) are trans-
orming the cabling technology requirements or data
centers and computer rooms.
The cabling interconnect technology, materials and
construction, plays an increasingly larger role in the
achievable interconnect distances and cable manage-
ment aspects or these high speed-high density data cen-
ters, computer rooms, and equipment rooms. Network
designers are struggling with critical path design choices.
LEONIs EDS makes the right design choices possible.
LEONI high speed parallel pair cables with LEONIsespecially ormulated dielectric enables a smaller cable
diameter; reducing cable density and improving air fow
and heat dissipation within servers and storage enclos-
ures. LEONIZELL dielectrics oer signicantly lower loss
and reduced time delay skew and amplitude skew over
alternative materials.
Due to their combined mechanical and electrical
perormance, high speed cables rom LEONI are also
deployed in mobile networks serving as high speed inter-
connections between racks inside base stations.
LEONIs ParaLinkcable product line is designed and
oered to optimise the bandwidth cost ratio or a variety
o high speed copper applications. ParaLinkhas esta-
blished the benchmark or size, perormance, and cost
over current data center product oerings.
Due to its almost unique value added chain, LEONI is able
to oer ber optic and data cables or EDS next to the
Telecom business units ParaLinksolutions.
Fast Cables. Quick Solutions.
www.leoni-telecom.com
-
7/28/2019 data cables with drawings and charts
3/16
Issue 11/2008
All ParaLinkproducts are permanently enhanced
or our customers. Thereore this brochure is subject
to change and error. You will nd the updated status
in our datasheets at www.leoni-telecom.com
Features & Benefts 4
10 GHz Operations 8
5 GHz Operations 9
3 GHz Operations 10
3 GHz Fibre Channel 11
5 GHz PCI Express 12
10 GHz PCI Express 13
Measuring Laborator y 14
The Quality Connection Worldwide 15
Contents
LEONI is a member
o the ollowing organisations:
LEONI 3
-
7/28/2019 data cables with drawings and charts
4/16
ParaLinkFeatures and Benets
Outside diameter < 15 %
increased cooling/airfow
Mode conversion excellent
reduces common mode propagations
Insertion loss 15 20% improvementequals longer distance
Skew
-
7/28/2019 data cables with drawings and charts
5/16
Dielectric Technologies
LEONIZELL unique gas injection skin-oam-skin dielectric technology
has been specically developed or the ParaLinkhigh speed dieren-
tial pair product line. The LEONIZELL structure oers a very rugged
and stable mechanical structure with the ollowing advantages and
benets compared to legacy industry structures:
Maximum adhesion to the inner conductor
limits pistoning eects with cable fexure
minimises shrink back eects
o the dielectric during termination (soldering / welding)
eliminates air voids close to the center conductor
prevents instable electrical perormance
Resilience to mechanical deormations
minimises perormance degradation during and ater installation
eliminates insertion loss suck-outs caused by bending and fexure
ensures predictable perormance even ater severe abuse
Colour coding
enables an easy termination
enables orientation o the conductors within the pair
elimination o perormance degradation due to pigmentation
within dielectric technologies
Cabling Technologies
The unique cabling technology used in the ParaLinkmanuacturing
process oers signicant space savings and a reduction o the outer
cable diameter, in most cases up to 15 % and even as much as 20 %
compared to conventional cabling technologies. The ParaLinkunilay
cable lay-up prevents mechanical deormation o the dierential pair
at the same time as reducing the eect o compression on dierential
pairs. Thereore it minimises negative infuences on the transmission
line and
improves the transmission lines signal integrity.
reduces the cables outer diameter
(i.e. 4XAWG26 diameter is equal to that o many
competitors 4XAWG28).
simplies routing and cable management.enables smaller and tighter bending radii.
increases cable densities.
reduces weight.
reduces pistoning eects.
100 %
Par aL i n k r educes pi sto n in g eects co m par ed to r equen t h i gh speed cabl es .
Comparison LEONIZELL and requent dielectric. ParaLink diameter compared to requently used high speed cable diameter.
LEONIZELL commonly used
dielectric technology
LEONI 5
-
7/28/2019 data cables with drawings and charts
6/16
0 2000 4000 6000 8000 10000 12000 14000 16000 180000.00
1.00
2.00
3.00
4.00
5.00
6.00
Insertion Loss Deviation
SDD21/dB
/MHz 0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109
0
10
20
30
40
50
60
/MHz
Mode Conversion IL with Mode Conversion IL ideal
Sxy21/dB
Infuence o mode conversion on the insertion loss
min.
max.
ParaLinkUnique Perormance
The variation o insertion loss (ILV) measures the dierences o inser-
tion loss between channels or pairs. Certain actor, or example return
loss, mode conversion, impedance, dimensions o cable, insulation
materials have an infuence on the pair insertion loss (IL). I the IL
between all pairs o a cable varies in a small range (typ. less than
5 % with ParaLink) the quality o the cable is high and the channel
perormance is predictable.
Mode Conversion (SCDxy) describes the relationship between trans-
mitted dierential mode signal energy at one end o the cable to the
received common mode energy at the other end. It is measured in the
requency domain. The eect o mode conversion (MC) is additional
insertion loss and it occurs mostly due to asymmetry between both
signal wires o a pair. In time domain this eect is well known as intra
pair skew, a time delay between both signal parts at 50 % o the sig-
nal step. Measuring the mode conversion o a cable has the advantageagainst skew measurements, that the losses o the dierential signal
or dierent data rates (= dierent requency bandwidths) will be
visible.
Examples or Mode Conversion:
Insertion Loss Variation (ILV) Mode Conversion
Ideal cable: A symmetric dierential signal is transmitted into a cable
without loss. Tx+(t) = Tx-(t)
At the receiving end the dierential mode signal has twice the height
o the signal parts Tx+ and Tx-. In this case a common mode signal
does not exist.
Tx+
Tx
Tx Rx
Rx di = Rx+ - Rx
Rx comm = Rx+ + Rx
Transmission o an ideal cable
6 LEONI
-
7/28/2019 data cables with drawings and charts
7/16
0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109
0
10
20
30
40
50
60
/MHz
Mode Conversion IL with Mode Conversion IL ideal
Sxy21/dB
Sxy21/dB
0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109
0
10
20
30
40
50
60
/MHz
Mode Conversion IL with Mode Conversion IL ideal
Bad CableParaLink
I the cable is almost absolutely symmetric, both transmitted signal
parts arrive simultaneously with the same (opposite) amplitude atten-
uated at the receiving end o the cable. Because Rx+(t) signal is close
to Rx-(t) signal, the common mode signal is still very low.
Due to dierent lengths o the wires within the shielded pair, the posi-
tive signal part o the dierential signal arrives at the receiving end o
the cable at a dierent time compared to the negative part. The Rx+(t)
signal is not equal to -Rx-(t) any more. A common mode signal arises.
At the same time the dierential mode signal energy decreases.
Rx+
Rx
Tx Rx
Rx di = Rx+ - Rx
Rx comm = Rx+ + Rx
Tx+
Tx
Tx+
Tx
Tx Rx
Rx di = Rx+ - Rx
Rx comm = Rx+ + Rx
Rx+
Rx
Skew
Common Mode Energie
Jitt er: T he mom ent
at which the signal
changes are getting
indeterminate.
LEONI 7
-
7/28/2019 data cables with drawings and charts
8/16
100 900 1700 2500 3300 4100 4900 5700 6500 7300 8100 890 0 9700 10000
0
1
2
3
4
5
6
7
8
MHz
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
32 AWG
* InfniBand is a registered t rademark o the InfniBand Trade Association.
ParaLink11
Guarantees swept perormance up to 10 GHz
Form Factor 1X 4X 10X 12X
32 AWG L45468-J11-C245 (PVC)
L45468-J11-C246 (LSZH)
L45468-J411-C215 (PVC)
L45468-J411-C216 (LSZH)
L45468-J1211-C55 (PVC)
L45468-J1211-C56 (LSZH)
30 AWG L45468-J12-C245 (PVC)
L45468-J12-C246 (LSZH)
L45468-J412-C215 (PVC)
L45468-J412-C216 (LSZH)
L45468-J1012-C55 (PVC)
L45468-J1012-C56 (LSZH)
L45468-J1212-C55 (PVC)
L45468-J1212-C56 (LSZH)
28 AWG L45468-J13-C245 (PVC)
L45468-J13-C246 (LSZH)
L45468-J413-C215 (PVC)
L45468-J413-C216 (LSZH)
L45468-J1013-C55 (PVC)
L45468-J1013-C56 (LSZH)
L45468-J1213-C55 (PVC)
L45468-J1213-C56 (LSZH)
26 AWG L45468-J14-C245 (PVC)
L45468-J14-C246 (LSZH)
L45468-J414-C215 (PVC)
L45468-J414-C216 (LSZH)
L45468-J1014-C55 (PVC)
L45468-J1014-C56 (LSZH)
L45468-J1214-C55 (PVC)
L45468-J1214-C56 (LSZH)
24 AWG L45468-J15-C245 (PVC)
L45468-J15-C246 (LSZH)
L45468-J415-C215 (PVC)
L45468-J415-C216 (LSZH)
L45468-J1015-C55 (PVC)
L45468-J1015-C56 (LSZH)
L45468-J1215-C55 (PVC)
L45468-J1215-C56 (LSZH)
Application
ParaLink11 is designed or dierential I/O interconnections in servers,
routers, switches, storage systems and any application with theoretical
data transmission speeds o up to 20 Gb/s per channel.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
withstand multiple fexure over a small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL
1685 and IEC 60332-3-24.
Electrical properties
Impedance 100 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
100 ps/10 m (3 ps/t)
Pair to pair
400 ps/10 m (12 ps/t)
ILV max. +/ 5%
*HSSG = High Speed Study Group
EA QSFP MGInfniBand*
HSSG*(IEEE)
SFP+
8 LEONI
-
7/28/2019 data cables with drawings and charts
9/16
100 900 1700 2500 3300 4100 4900 5000
0
1
2
3
4
MHz
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
ParaLink5
Guarantees swept perormance up to 5 GHz
Form Factor 1X 4X 12X
30 AWG L45468-J12-C25 (PVC)
L45468-J12-C26 (LSZH)
L45468-J412-C15 (PVC)
L45468-J412-C16 (LSZH)
L45468-J1212-C5 (PVC)
L45468-J1212-C6 (LSZH)
28 AWG L45468-J13-C25 (PVC)
L45468-J13-C26 (LSZH)
L45468-J413-C15 (PVC)
L45468-J413-C16 (LSZH)
L45468-J1213-C15 (PVC)
L45468-J1213-C16 (LSZH)
26 AWG L45468-J14-C75 (PVC)
L45468-J14-C76 (LSZH)
L45468-J414-C115 (PVC)
L45468-J414-C116 (LSZH)
L45468-J1214-C85 (PVC)
L45468-J1214-C86 (LSZH)
24 AWG L45468-J15-C45 (PVC)
L45468-J15-C46 (LSZH)
L45468-J415-C25 (PVC)
L45468-J415-C26 (LSZH)
L45468-J1215-C25 (PVC)
L45468-J1215-C26 (LSZH)
Application
ParaLink5 is designed or dierential I/O interconnections in servers,
routers, switches, storage systems and any application with theoreti-
cal data transmission speeds o up to 8 Gb/s per channel.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
withstand multiple fexure over a small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL
1685 and IEC 60332-3-24.
Electrical properties
Impedance 100 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
200 ps/10 m (6 ps/t)
Pair to pair
500 ps/10 m (15 ps/t)
ILV max. +/ 5 %
QSFP MGHSSG(IEEE)
SFPInfniBand
SAS2
LEONI 9
-
7/28/2019 data cables with drawings and charts
10/16
100 900 1700 2500 3000
0
1
2
3
4
MHz
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
Form Factor 1X 4X 8X 12X
30 AWG L45468-J12-C15 (PVC)
L45468-J12-C16 (LSZH)
L45468-J412-C25 (PVC)
L45468-J412-C26 (LSZH)
L45468-J812-C15 (PVC)
L45468-J812-C16 (LSZH)
L45468-J1212-C25 (PVC)
L45468-J1212-C26 (LSZH)
28 AWG L45468-J13-C45 (PVC)
L45468-J13-C46 (LSZH)
L45468-J413-C25 (PVC)
L45468-J413-C26 (LSZH)
L45468-J813-C5 (PVC)
L45468-J813-C6 (LSZH)
L45468-J1213-C25 (PVC)
L45468-J1213-C26 (LSZH)
26 AWG L45468-J14-C65 (PVC)
L45468-J14-C66 (LSZH)
L45468-J414-C35 (PVC)
L45468-J414-C36 (LSZH)
L45468-J814-C5 (PVC)
L45468-J814-C6 (LSZH)
L45468-J1214-C25 (PVC)
L45468-J1214-C26 (LSZH)
24 AWG L45468-J15-C95 (PVC)
L45468-J15-C96 (LSZH)
L45468-J415-C65 (PVC)
L45468-J415-C66 (LSZH)
L45468-J815-C5 (PVC)
L45468-J815-C6 (LSZH)
L45468-J1215-C15 (PVC)
L45468-J1215-C16 (LSZH)
ParaLink3
Guarantees swept perormance up to 3 GHz
Application
ParaLink-3 is designed or dierential I/O interconnections in servers,
routers, switches, storage systems and any application with theoreti-
cal data transmission speeds o up to 5 Gb/s per channel.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
withstand multiple fexure over a small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL
1685 and IEC 60332-3-24.
Electrical properties
Impedance 100 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
200 ps/10 m (6 ps/t)
Pair to pair
500 ps/10 m (15 ps/t)
ILV max. +/ 5 %
eSATA SAS SFPEAInfniBand
FCIA HSSDCII MG
10 LEONI
-
7/28/2019 data cables with drawings and charts
11/16
100 900 1700 2500 3000
0
1
2
3
4
MHz
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
ParaLink3or Fibre Channel
Guarantees swept perormance up to 3 GHz
Application
ParaLinkor Fibre Channel is designed or dierential I/O interconnec-
tions in servers, routers, switches, storage systems and any application
with theoretical data transmission speeds o up to 8 Gb/s per channel
at 150 Ohm.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
bear up against extreme fexure and small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL
1685 and IEC 60332-3-24.
Electrical properties
Impedance 150 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
200 ps/10 m (3 ps/t)
Pair to pair
500 ps/10 m (12 ps/t)
ILV max. +/ 5 %
Form Factor 1X
28 AWG L45468-G12-C5 (PVC)
L45468-G12-C6 (LSZH)
26 AWG L45468-G14-C5 (PVC)
L45468-G14-C6 (LSZH)
24 AWG L45468-G15-C5 (PVC)
L45468-G15-C6 (LSZH)
22 AWG L45468-G16-C5 (PVC)
L45468-G16-C6 (LSZH)
HSSDCII MGFCIA
LEONI 11
-
7/28/2019 data cables with drawings and charts
12/16
ParaLink5or PCI Express
with sideband signalling
Guarantees swept perormance up to 5 GHz
Application
ParaLink or PCI express is designed or dierential I/O interconnec-
tions in servers, routers, switches, storage systems and any application
with theoretical data transmission speeds o up to 5 Gb/s per channel.
Side band and clock pair (28 AWG) are available with power con-
ductors.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
bear up against extreme fexure and small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL
1685 and IEC 60332-3-24.
Electrical properties
Impedance 100 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
200 ps/10 m (3 ps/t)
Pair to pair
500 ps/10 m (12 ps/t)
ILV max. +/ 5 %
Form Factor 4X
30 AWG L45468-J712-C45 (PVC)
L45468-J712-C46 (LSZH)
28 AWG L45468-J713-C45 (PVC)L45468-J713-C46 (LSZH)
26 AWG L45468-J714-C45 (PVC)
L45468-J714-C46 (LSZH)
24 AWG L45468-J715-C45 (PVC)
L45468-J715-C46 (LSZH)
IPass is a registered trademark o molex
IPASSGEN 2PCIExpress
e.g. L45468-J715-C45 & L45468-J715-C46
100 900 1700 2500 3300 4100 4900 5000
0
1
2
3
4
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
MHz
12 LEONI
-
7/28/2019 data cables with drawings and charts
13/16
IPASSGEN 3PCIExpress
ParaLink11or PCI Express
with sideband signalling
Guarantees swept perormance up to 10 GHz
Application
ParaLink11 or PCI express is designed or dierential I/O interconnec-
tions in servers, routers, switches, storage systems and any application
with theoretical data transmission speeds o up to 8 Gb/s per channel.
Side band and clock pair (28 AWG) are available with power con-
ductors.
Mechancial properties
Bending radius Due to the extreme durability o the special materi-
als and the unique cable geometry the cables can
bear up against extreme fexure and small bending
radius.
Fire perormance Due to an outer jacket, which is available with halo-
gen and lead-ree propietary elastomer, the cable is
certied according to UL 13 CL2 in compliance with
CSA FT4 and thereore is tested according to UL1685 and IEC 60332-3-24.
Electrical properties
Impedance 100 Ohm
Insertion loss Up to 15 % lower than the industry average
Skew Conductor to conductor
200 ps/10 m (3 ps/t)
Pair to pair
500 ps/10 m (12 ps/t)
ILV max. +/ 5 %
Form Factor 4X
30 AWG L45468-J712-W215 (PVC)
L45468-J712-W216 (LSZH)
28 AWG L45468-J713-W215 (PVC)
L45468-J713-W216 (LSZH)
26 AWG L45468-J714-W215 (PVC)
L45468-J714-W216 (LSZH)
24 AWG L45468-J715-W215 (PVC)
L45468-J715-W216 (LSZH)
100 900 1700 2500 3300 4100 4900 5700 6500 7300 8100 890 0 9700 10000
0
1
2
3
4
5
6
7
8
MHz
a/(dB/m)
Insertion loss
24 AWG26 AWG
28 AWG
30 AWG
e.g. L45468-J714-W215 & L45468 -J714-W216
LEONI 13
-
7/28/2019 data cables with drawings and charts
14/16
LEONI Measuring Laboratory
The measuring laboratory o the LEONI Business Unit Telecom isintended to unction as a research and development lab. It will also
provide quality assurance or manuacturing high-speed cables or
high-bandwidth/requency applications.
A ully air-conditioned, antistatic environment and proper measu-
rement xture methods have been created and developed to ensure
the accuracy, calibration and repeatability o testing activities. The test
lab is equipped with state-o-the-art network analyzers rom Agilent
Technologies, enabling tests or dierential transmission lines in re-
quencies up to 50 GHz.
Two 4 port network analyzers (4x 50 Ohm or 2x 100 Ohm) equipped
with the newest PLTS (Physical Layer Test System) sotware avoid the
need or transormers, thus providing accurate measurements o the
transmission line.
Traditional measuring transormers must be used with an impe-
dance matching the impedance or the transmission line, usually about
100 Ohm or InniBand and 150 Ohm or Fibre Channel applications.
They are limited in the measurement o high requencies and cannot
measure mode conversion. This makes it virtually impossible to take
accurate measurements in the bandwidth o interest or the high-
perormance transmission line applications mentioned above.
The lab is also equipped with two Tektronix TDA or time domainmeasurements, such as time delay, skew, impedance and distance
to ault, which can also be determined in the requency domain
using network analyzers. However, using network analyzers requires
signicant margins o error in mathematical transormations rom
requency to time domain.
The LEONI signal integrity development laboratory has extensive
proprietary sotware at disposal to model, simulate and emulate all
perormance aspects o the signal integrity o a given dierential
transmission line, including SPICE and eField models. That, combinded
with 12,5 GB/s Advantest pulse pattern generators, provides LEONI
with a solid engineering base to aid and accelerate customer develop-
ment programs.
Foto: Agilent Technologies
Foto: D3186 rom Advantest
14 LEONI
-
7/28/2019 data cables with drawings and charts
15/16
LEONI quality managementA consistently high level o quality is vital or our products.
This means that the entire process at LEONI rom a products plan-
ning to its completion is constantly monitored. Our quality man-
agement system is certied in accordance with DIN/ISO 9001:2000
and is updated permanently.
Environment-riendly and sae
O course, halogen-ree versions o a great number o the cables in
our range are also available. This does reduce the strain in the envi-
ronment, it also means less smoke and corrosive emissions in case
o a re or your saety.
LEONI environmental management
For us, business success with ecological responsibility is not a con-
tradiction in terms. Because o this, environmental protection is an
intrinsic element o our corporate activities. Our environment man-
agement system is certied as complying with DIN EN ISO 14001,
conrming that our environment policy is eectively implemented.
The Quality ConnectionWorldwide
Please fnd your sales contact at www.leoni-telecom.com/sales