It’s a drum, it’s a barrel, it’s a 1A2. No! It’s a Packaging!

Presented to DGIS II28 November 2007 ByW. Dean RickerSkolnik Industries, Inc.

Page 2: Dangerous Goods Symposium 11 28-07

2006 Steel Drum Statistics

28 Million new steel drums produced

32 Million steel drums reconditioned

Page 3: Dangerous Goods Symposium 11 28-07

2006 Steel Drum Market Share

72.5% Steel Drums

14.8% Plastic Drums

12.8% IBC’s

Page 4: Dangerous Goods Symposium 11 28-07

Type A Package: CFR 173.403

“…means a packaging that, together with its radioactive contents…”

Page 5: Dangerous Goods Symposium 11 28-07

Type A: CFR 173.465

TESTS:Drop Penetration Water Spray Stacking

Page 6: Dangerous Goods Symposium 11 28-07

Nitric Acid: CFR 173.158

1A1 Stainless Steel Drum

0.9 mm Minimum Thickness

Type 304 or Equivalent

Heat Treated Steel What doesn’t the CFR

tell us?

Page 7: Dangerous Goods Symposium 11 28-07

“I’ve got a slew of Methyl Ethyl Death…”

Drum School 101

CFR 101

Page 8: Dangerous Goods Symposium 11 28-07

The Macho Mark, 1A2/X2.5/500 vs a Smart Mark:

Page 9: Dangerous Goods Symposium 11 28-07

Closure Instructions

Page 10: Dangerous Goods Symposium 11 28-07

Salvage Drums: CFR 173.3 ( c )

Must be compatible with lading

UN 1A2, 1H2, 1B2 etc.

PG III or higher Leakproofness test of

20 kPa What doesn’t the CFR

tell us?

Page 11: Dangerous Goods Symposium 11 28-07

Salvage Drum Re-use: CFR 173.28

No reduction in integrity

48 kPa leakproofness test for PG I

20 kPa leakproofness test for PG II and III

Marked with “L”, name, address or symbol and year.

Page 12: Dangerous Goods Symposium 11 28-07

Use of Identical Replacement Parts

Covers Bolt Rings Leverlock Rings Gaskets Plugs

Page 13: Dangerous Goods Symposium 11 28-07

The thinning epidemic!

Page 14: Dangerous Goods Symposium 11 28-07

What are the consequences?

Fewer drums do not meet CFR 173.28 & are not able to be re-used or reconditioned

More susceptible to damage

Greater risk of failure

Page 15: Dangerous Goods Symposium 11 28-07

Thank you…

T: 773.362.1910