    Wide selection with

    the inverter series

    Economy and comfort are essential to

    store and office air conditioning.Our varied lineup meets customer needs when itcomes to functions and indoor unit types.

    Enhanced Comfort with

    Daikin InverterComfortable air conditioning is achieved through variable output control made possible by the inverter, which continuallymaintains the set temperature while detecting load, which varies with time of day and number of room occupants.

    P r o d u c t L i n e u p

    FBQ71BV1A

    RXS71FVMA

    ROUND FLOWOUN FLOWROUND FLOW

    Outdoor unit

    Indoor unit

    Outdoor unit

    Indoor unit

    CEILING SUSPENDED TYPE

    CEILING MOUNTED

    CASSETTE TYPE

    COMPACT MULTI FLOW

    CEILING MOUNTEDCASSETTE TYPE

    Outdoor unit

    Indoor unit

    Outdoor unit

    Indoor unit

    CEILING MOUNTED

    BUILT-IN TYPE

    DUCT CONNECTION

    MIDDLE/HIGH STATIC

    PRESSURE TYPE

    Outdoor unit

    Indoor unit

    FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B

    RKS35AVMG RKS50AVMG RKS60AVMG

    RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG

    FFQ35BV1BFFQ25BV1B FFQ50BV1B FFQ60BV1B

    RXS50FAVMA RXS60FVMA

    FBQ50BV1A FBQ60BV1A

    Round Flow

    RXS71FVMA

    1

    25 35 50 60 71

    RKS25AVMG RKS35AVMG RKS50AVMG

    RXS50FAVMA

    RKS50AVMG RKS60AVMG

    RKS60AVMG

    RXS60FVMA

    Series

  • 8/9/2019 Daikin Skyair

    3/40

    Energy savings withhigh-efficiency inverterThe outdoor unit is equipped with a reluctance DC scroll compressor that utilizes the latest technology. It bringsout the full energy-saving potential of the inverter, which controls power used in accordance with load variation.

    New, compactoutdoor unitThe outdoor unit is easy to install in storesand offices where space is limited.

    Page 5

    Page 9

    Page 11

    Page 13

    Page 15

    Page 17

    FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B

    RZR71KUV1 RZR100KUV1 RZR125HUY1

    FHQ125BVV1B

    RZR125KUV1

    FHQ100BVV1B

    RZR100HUY1

    FCQ71KVEA

    71

    FCQ100KVEA FCQ125KVEA FCQ140KVEA

    100 125 140

    RZR125HUY1

    FCQ125KVEA

    RZR125KUV1

    FCQ100KVEA

    RZR100HUY1RZR100KUV1RZR71KUV1 RZR140HUY1

    FCQ140KVEA

    RZR140KUV1

    FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1

    RZR125HUY1

    FBQ125DV1

    RZR125KUV1

    FBQ100DV1

    RZR100HUY1RZR100KUV1RZR71KUV1 RZR140HUY1

    FBQ140DV1

    RZR140KUV1

    RZR71KUV1 RZR100HUY1RZR100KUV1 RZR125HUY1 RZR140HUY1

    2

    O U T D O O R U N I T

    RZR140KUV1RZR125KUV1

    NEW

    NEW NEW NEW NEW NEW NEW NEW

    NEW

  • 8/9/2019 Daikin Skyair

    4/40

    Non-inverter

    Inverter Time

    Runningcurrent

    Starting current

    Time

    Running current

    Current

    Current

    At startup, inverter raises frequency smoothly,

    eliminating the starting current spike.

    Soft starter is

    unnecessary, making

    electrical installation

    work much simpler.

    At startup, full power is used to achieve the set temperaturequickly. Then, the capacity is adjusted according to the outdoortemperature changes and subtle indoor load changes toachieve fine capacity control resulting in a more stable room

    temperature.

    Inverter performs variable control of frequency,which determines air conditioners powerperformance.

    360airflow with improvedtemperature distribution.

    Enhanced comfort with Inverter

    Small temp.differenceCools a room

    in less time

    Cooling operation

    Inverter power control

    Non-inverter type air conditioner

    Time

    Temp

    Set temp

    Non-inverter type air conditioners must be switched onand off repeatedly, causing large fluctuationsof the room temperature.

    Comfortable airflow

    Comfortableomfortable

    Round Flow cassetteound Flow cassette

    Comfortable

    Round Flow cassette

    360 airflow

    realises uniform

    airflow distribution.4-way flow leaves areas

    that cannot be covered.

    Greater comfortImproved energy saving

    Round Flow typeConventional

    4-way flow type

    ROUND FLOWOUN FLOWROUND FLOW

    3

  • 8/9/2019 Daikin Skyair

    5/40

    Models have received Singapore's 4 Tick Energy Label, which is the

    highest energy-efficiency rating for inverter type air conditioner.

    The mandatory labelling scheme was introduced by Singapore

    National Envirionment Agency.

    48

    49

    RZR71KU

    Sound level*(dB(A))

    RZR100KU/100HU

    50RZR125KU/125HU

    50

    47

    49

    45

    46RZR140KU/140HU

    Rated Night Quiet Mode

    Energy savingnergy savingEnergy saving4 Tick Energy Label

    Optimised Efficiency with R-410A

    COP is equal to capacity (kW) divided by power

    consumption (kW), and the larger the COP value, the higher

    the energy efficiency, enabling cooling and heating with less

    electricity and increasing the energy saving performance.

    Note :Rated cooling capacities are based on the following conditions: Indoortemp., 27CDB, 19.0CWB; outdoor temp. 35CDB Equiv. refrigerationpiping, 7.5 m (horizontal).

    What is COP(Coefficient of Performance)

    COP

    1

    2

    3

    4

    FCQ100KVEA FCQ125KVEA FCQ140KVEARZR100KUV1 RZR125KUV1 RZR140KUV1

    RZR100KUV1

    Quiet operationuiet operationQuiet operationNight quiet

    operation function

    Navigation Remote Controlleravigation Remote ontrollerNavigation Remote ControllerClear display, Simple operation,

    "Navigation Remote Controller"!

    3.40

    Cooling*

    FCQ71KVEARZR71KUV1

    3.32

    Cooling*

    2.83

    Cooling*

    3.57

    Cooling*

    RKS25AVMG RZR71KUV1 RZR100KUV1

    4

    Note :

    Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhathigher owing to ambient conditions.

    Dot matrix display

    Backlight display

    Large buttons and arrow keys

    Guide on display

    Weekly schedule timer Multilingual display

    Clear Display

    Other Features

    Simple operation

    Wired Remote ControllerBRC1E61(Optional)

  • 8/9/2019 Daikin Skyair

    6/40

    *1 Cooling only

    MouldpreventionComfort Work & Servicing Control features OthersOptionsFeature

    Features

    Model

    Accessory required for indoor unit

    Option

    *1Applicable when wired remote controller is used

    CEILING MOUNTED CASSETTE TYPE

    FCQ71K/100K/125K/140K

    Swingp

    atternselection

    Switcha

    blefanspeed

    Autosw

    ing

    Program

    me"Dry"

    Highce

    ilingapplication

    Year-roundcooling

    applicable

    Timerselector

    Drainp

    umpmechanism

    Precha

    rgedfor

    upto30m

    Long-li

    fefilter

    Mould-resistanttreatment

    forfilter

    Filtersign

    Ceiling

    soilingprevention

    Lowgaspressure

    detection

    Emerge

    ncyoperation

    Self-d

    ia

    gnosisfunction

    Ultralong-l

    ifefilter

    High-ef

    ficiencyfilter

    Freshairintakekit

    Controlby2remote

    controllers

    Auto-re

    start

    Controlby1remote

    controller

    Externa

    lcommand

    control

    Central

    remotecontrol

    Interloc

    kcontrol

    PEfin

    Twoselectable

    temper

    ature-sensors

    Round Flow

    ROUND FLOWOUN FLOWROUND FLOW

    Uniform 360 airflow cassette air conditioneris setting tomorrow's standards.Uniform 360 airflow cassette air conditioneris setting tomorrow's standards.

    GOODDESIGN

    AWARD 2004

    IN JAPAN

    5

    Note: Remote controller cable not included. Cables must be procured locally.

    BRC1E61

    Navigation RemoteController(Wired Remote Controller)

    BRC7F632F

    A signal receiver must be added to the indoor unit.

    Wireless remote controller and signal

    receiver unit are sold as a set.

    Wireless LCD remote controller

    Signal receiver unit(Installed type)

    Note: Remote controller cable not

    included. Cables must be

    procured locally.

    Wired LCD remote controller

    Wired LCD remotecontroller with weeklyschedule timer

    BRC1C61

    BRC1D61

  • 8/9/2019 Daikin Skyair

    7/40

    Airflow

    distribution

    Creates uniform

    comfort throughout

    the space

    Comfort enhanced by Round Flow!

    With uniform temperaturedistribution Enhanced Comfort

    Greater comfortImproved energy saving

    Condition after exposure

    to the smoke of 600

    cigarettes in 1 m3

    enclosed space.

    Treatedsurface

    Untreatedsurface

    Grimysurface

    Resistssoiling

    External panels are treated with a coating that

    repels dirt.

    Anti bacterial treatment, that includessilver ions is used which may assist in

    preventing the growth of microorganisms

    that cause smells and clogging.

    Avoids ununiform temperature and uncomfort caused by drafts.

    To prevent dirt sticking to the

    external panels, they have

    been coated with a surface

    treatment.

    Because air flows out from corner outlets, comfort spreads more widely.

    360 airflow Air movement is gentle with Round Flow

    Dew does not easily form on and dirtdoes not cling to non-flocking louvres.

    It is easy to clean.

    Non-flocking horizontal louvresBactericidal treatment for

    drain panPrevents mould and microorganismsgrowing out of the dust and moisture

    that adheres to the filters.

    Filter has anti-mould andbactericidal treatment

    Grime prevention and bactericidal coating: Make cleaning easier.

    Adapts easily to the installation space.

    Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to

    close each unused outlet.

    3-way flow L-shaped2-way flow

    Opposite2-way flow

    (E.g., installed ina corner)

    (E.g., installed ina long room)

    (E.g., installednear a wall)

    (E.g., installed inmiddle of ceiling)

    4-way flow also possible.

    All-round flow

    360airflow canmaintain comforteven if airdischarge speed islower.

    Typical flow patterns There are a total of 23 flow patterns.

    If you raise the set temperature by 1 to 1.5C,and velocity is decreased by 25%,You still obtain the same feeling temperature and comfort.

    6

    Operation sound increases when using 2-way or 3-way flow.

  • 8/9/2019 Daikin Skyair

    8/40

    CEILING MOUNTED CASSETTE TYPE Round Flow

    Quick and easy to installJust 256 mm high. Installable in tight

    ceiling spaces (71K)

    7

    Fine square panels Compact body and quiet operation

    *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.

    **Wireless remote controller does not have a temperature-sensor.

    Note : Anechoic chamberconversion value, measuredaccording to JIS parametersand criteria. Duringoperation these values are

    somewhat higher owing toambient conditions.

    Note: Air direction is set to the standard position when the unit is shipped from the factory.The position can be changed from the remote controller.

    Panel size is same for all models, FCQ71-140K.It is easy to maintain a neat appearance whenmultiple units are installed.

    Optimal comfort and convenienceassured by air discharge modes

    Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, tofurther improve comfort level, closer to the target area at the wired remotecontrol. This feature must be set during commissioning by the technicians.

    Two selectable temperature-sensors

    Even in spaces with high ceilings, a comfortable airflow is carried down to

    the floor level.

    Suitable for high ceilings

    Operation starts when the preset time of the ON timer elapses and stops

    when the preset time of the OFF timer elapses.

    Timer selector

    Indoor unit High Low

    125K 44 34

    140K 44 36

    100K 43 32

    71K 35 28

    dB(A)

    Same for

    all models

    Air direction

    Auto air

    direction control

    Settable to 5 different

    levels between 15and 60

    Settable to 5 different

    levels between 25and 60

    Auto-swing between15and 60

    Auto-swing between25and 60

    Recommended for shops withlight coloured ceilings that

    must be kept spotless.

    Standard position to

    prevent draft.

    Standard setting Setting to prevent soiling of ceiling*

    The air direction is set automatically to thememorised position of the previous air direction.

    Desired

    situation

    Auto-swing

    5-levelsair directionsetting

    *Closing of the corner discharge outlets is recommended.

    Number of air discharge outlets used

    71K4-wayflow

    3-wayflow

    2-wayflow

    4-wayflow

    3-wayflow

    2-wayflow

    100K140K

    3.1 m

    3.4 m

    4.0 m

    All round

    flow

    2.7 m

    3.0 m

    3.5 m

    3.0 m

    3.3 m

    3.5 m

    3.5 m

    3.8 m

    -

    3.4 m

    3.9 m

    4.5 m

    All round

    flow

    3.2 m

    3.6 m

    4.2 m

    3.6 m

    4.0 m

    4.2 m

    4.2 m

    4.2 m

    -

    StandardCeilingheight

    High ceiling

    High ceiling

    Criteria for ceiling height and number of air discharge outlets

    950m

    m 950mm

    Note: Factory settings are for standard ceiling height and all-round flow.

    High ceiling settings (1) and (2) are set with the remote controller.

    256 mm *1 265 mm *2

    *1 298 mm high with 100K140K

    *2 303 mm high with 100K140K

    All models can be installed without

    using lifter because of the light weight.

    Easier connection with the centralisedcontrol system

    Low gas pressure detection

    Drain pump is equipped as standard

    accessory with 850 mm lift.

    Transparent drain socket

    Each corner of the unit has an Adjuster Pocket that

    lets you easily adjust the unit's suspended height.

    Since the orientation of

    the intake grill can be

    adjusted after installing,

    the direction of the intakegrill lines can be unified

    when multiple units

    are installed.

    Note: If the wireless remote control option is installed, a light receptor

    unit is housed in one of the adjuster pockets.

    Easy height adjustment

    Installable inany direction

    Because the drain socket istransparent, after the drain piping

    has been installed, it is easy to

    check if the drain come out

    through the socket.High setting provides maximum reach while low

    setting minimises drafts.

    Switchable fan speed: High/Low

    175 mm

    850mm

  • 8/9/2019 Daikin Skyair

    9/408

    Options required for specific operating environments

    High-efficiency filterAvailable in two types: 65% and 90% colorimetry.

    Using this kit, a

    duct can be fitted

    to increase the

    intake of outdoorair.

    *Connecting ducts, insect nets, fire dampers, air filters, and other

    parts should, as required, be procured locally.

    **Outside Air fan interlocked with air conditioning unit is necessary.

    Optional PCB(KRP1C63)is required for interlocking.

    ***It is recommended that the volume of outdoor air introduced

    through the kit is limited to 10% of the maximum airflow rate of the

    indoor unit. Introducing higher quantities will increase the

    operating sound and may also influence temperature sending.

    Fresh air intake kit

    Even in smoky environments wherethe air conditioning is on most of

    the time, the ultra long-life filter only

    has to be changed once a year.

    Ultra-long-life filter Panel spacerUse when only minimal space is available between drop

    ceilings and ceiling slabs.

    Sealing member of air discharge outletSealing members block air discharge openings not used in 2-way or 3-way blow.

    Branch duct(direct-connection round duct)

    Outside

    Note: Use of options will increase operating sound.

    The units can be installed in the following different ways.

    Note: Some ceiling constructions may hinder installation.

    Contact your Daikin Dealer before installing your unit.

    Direct installation type

    Flexible duct

    T-joint pipe

    Intake duct(procured locally)(duct length: 4 m max.)

    Intake duct(procured locally)(duct length: 4 m max.)

    Connectionchamber

    Suctionchamber

    Duct flange(with insulation material)

    Intake duct(procured locally)

    Chamber type

    (with T-joint pipe and without fan)

    Flexible duct(procured locally)

    T-joint pipe(procured locally)

    Chamber type

    (without T-joint pipe and fan)

    KDDP55X160KDDP55K160KKDDP55K160

    Easier to maintain

    With ultra-long-life filters (option ), maintenance is not required in normal shops or offices

    for up to four years.

    The condition of the drain pan anddrain water can be checked by

    removing the drain plug and

    intake grille.

    Drain plug

    Justope

    nthe

    intakegri

    lle!

    40mm

    Panel spacer

    A round duct can be attached without the need for a chamber.

    A flanged port for direct connection of a round duct is

    provided. An existing branch duct chamber can also be fitted

    (square slit hole).

    Connectionchamber

    Suctionchamber

    Smoky atmosphere: annual filter change

    Ordinary store or office: filter change every 4 years

    *For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.)1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year

    *For dust concentration of 0.15 mg/m3

    4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years

    Note:

  • 8/9/2019 Daikin Skyair

    10/409

    Cooling only

    MouldpreventionComfort Work & Servicing Control features OthersOptionFeature

    Features

    Model

    *1Applicable when wired remote controller is used*2Applicable to RKS25/35/50/60AVMG outdoor units

    COMPACT MULTI FLOWCEILING MOUNTEDCASSETTE TYPE

    Quiet, decor-blending form and easyinstallation in new or old buildings.Quiet, decor-blending form and easyinstallation in new or old buildings.

    Swingp

    atternselection

    Switcha

    blefanspeed

    Autosw

    ing

    Program

    me"Dry"

    Year-roundcooling

    applicable

    Timerselector

    Drainpumpmechanism

    Prechargedfor

    upto10m

    Long-lif

    efilter

    Mould-resistanttreatment

    forfilter

    Filtersign

    Emerge

    ncyoperation

    Self-diagnosisfunction

    Freshairintakekit

    Control

    by2remote

    controllers

    Auto-re

    start

    Control

    by1remote

    controller

    Externa

    lcommand

    control

    Central

    remotecontrol

    Interloc

    kcontrol

    PEfin

    Twoselectable

    temperature-sensors

    FFQ25B/35B/50B/60B

    *1 *2

    Accessory required for indoor unit

    Option

    BRC7E531W

    A signal receiver must be added to the indoor unit.

    Wireless remote controller and signalreceiver unit are sold as a set.

    Wireless LCD remote controller

    Signal receiver unit

    (Installed type)

    Note: Remote controller cable not included. Cables must be procured locally.

    BRC1E61

    Navigation RemoteController(Wired Remote Controller)

    Note: Remote controller cable not

    included. Cables must be

    procured locally.

    Wired LCD remote controller

    Wired LCD remotecontroller with weeklyschedule timer

    BRC1C61

    BRC1D61

  • 8/9/2019 Daikin Skyair

    11/40

    25B 29.5 24.5

    35B 32 25

    10

    CompactSized to fit inside 600mm wide

    ceiling grids

    Two selectable temperature-sensors

    *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.

    **Wireless remote controller does not have a temperature-sensor.

    Designed for low draft

    performance

    Consistent comfort throughout

    Quiet operation has been achieved even with a

    compact body and developed spiral hub cover that

    reduces the static pressure inside the indoor unit.

    Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, to furtherimprove comfort level, closer to the target area at the wired remote control.This feature must be set during commissioning by the technicians.

    High setting provides maximum reach while low setting minimises drafts.

    Switchable fan speed: High/Low

    Drain pump is equippedas standard accessory

    with 750 mm lift.

    Comfortable

    QuietQuiet, small-diameter fan

    Multi-Flow System Air direction can be

    selected according to

    installation.1 pattern

    4-way flow

    4 patterns

    3-way flow

    1 pattern

    2-way flow

    " " denotes piping direction. Drain piping

    " " denotes sealing member for air discharge

    outlet (option) .

    Note: For 3-way or 2-way flow installation, the sealing

    member for air discharge outlet (option) mustbe used to close off the unused outlet(s).

    Note: Operation sound increases

    when using 2-way or 3-way flow.

    Spiral hub cover

    750 mm

    Settable to 5 different levels

    between 0and 35

    Settable to 5 different levels

    between 0and 60

    Settable to 5 different levels

    between 25and 60

    Auto-swingbetween 0and 35

    Auto-swingbetween 0and 60

    Auto-swingbetween 25and 60

    Draftpreventionsetting(Set on site)

    (Set on site)

    Standardsetting

    Setting topreventsoiling ofceiling

    Auto-swing operationdistributes conditioned airmore evenly.

    Airfow angle can be adjustedin accordance with roomconditions.

    Auto-swing

    0 0

    0

    25

    60 60

    0

    35

    25

    60

    35

    60

    5-levels air direction setting

    Horizontal flow0 0

    Less draftcan be felt

    575 mm

    575 mm

    700 mm

    700 mm

    286mm

    50B 36 27

    High Low

    60B 41 32

    Fits without theneed to cut T-bargrid

    T bar

    600 mm 600mm

    Decoration

    panelisalso

    compact.

    Note: This angle above is provided as a guide. It may differ depending on the installation site.

    Ceiling panel

    Indoor unit

    The switch box is built in to the

    unit, so maintenance is possible

    by simply removing the grill. An

    inspection opening is notrequired even for modules other

    than 600 x 600.

    Note : Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhat higher

    owing to ambient conditions.

    dB(A)

  • 8/9/2019 Daikin Skyair

    12/4011

    Cooling only

    MouldpreventionComfort Work & Servicing Control features OthersFeature

    Features

    Model

    *3 *3*2 *1Installable on max. 3.5 m high ceiling*2Applicable when wired remote controller is used*3Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units

    Prechargedfor

    upto30m

    Long-lif

    efilter

    Mould-resistanttreatment

    forfilter

    Filtersign

    Lowgaspressure

    detectio

    n

    Emerge

    ncyoperation

    Self-d

    iagnosisfunction

    Control

    by2remote

    controllers

    Auto-re

    start

    Control

    by1remote

    controller

    Externa

    lcommand

    control

    Central

    remotecontrol

    PEfin

    Interloc

    kcontrol

    Drainpumpmechanism

    Switcha

    blefanspeed

    Autosw

    ing

    Program

    me"Dry"

    Highce

    iling

    application*1

    Year-roundcooling

    applicable

    Timerselector

    Twoselectable

    temper

    ature-sensors

    CEILING SUSPENDED TYPE

    Upgrade to a quiet andcompact system.Upgrade to a quiet andcompact system.

    FHQ35BV/50BV/ 60BV/71BV 100BV/125BV

    A signal receiver must be added to the indoor unit.

    Wireless remote controller and signal

    receiver unit are sold as a set.

    Wireless LCD remote controller

    Signal receiver unit (Installed type)

    Note: Remote controller cable not included. Cables must be procured locally.

    BRC1E61

    Navigation RemoteController(Wired Remote Controller)

    Note: Remote controller cable not

    included. Cables must be

    procured locally.

    Wired LCD remote controller

    Wired LCD remotecontroller with weeklyschedule timer

    BRC1C61

    BRC7EA66

    BRC1D61

    Accessory required for indoor unit

    Option

  • 8/9/2019 Daikin Skyair

    13/4012

    * For dust concentration of 0.15 mg/m3

    50

    (mm)

    Uses quiet stream fan and other quiettechnologies.

    Turbulent flowis produced

    Non-dew flap

    Straighteningvane

    Quietstream fan

    60BV 39 3350BV 38 33

    Indoor unit High Low

    35BV 37 32

    71BV 39 35

    100BV 42 37

    125BV 44 39

    195

    100BV 125BV

    960 1,160 1,400 1,590

    680

    Drain pump kit(built inside main unit)

    Height

    Indoor unit

    Width

    Depth

    35BV/50BV 60BV/71BV

    600 mm

    Quiet operation

    Easier to maintain

    Sound operation has been reduced on the exposedceiling suspended type unit.

    Two selectable temperature-sensors

    *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.

    **Wireless remote controller does not have a temperature-sensor.

    Absence of bristles minimises

    clinging dirt and simplifiescleaning.

    Oil resistant grille

    Oil-resistant plastic is used for the air dischargegrille. This satisfies durability in restaurants and

    other similar environments.

    Note: Intended for use in salons, dining rooms, and ordinary sales

    floors, this specification is not suitable for kitchens or other

    harsh environments.

    For all maintenance tasks, access is

    from bottom surface.

    Two time settings (2500 hrs and 1250 hrs) are available to match the

    installation environment. Maintenance time warning is displayed on

    the remote controller (filter sign).

    It is easy to wipe dirt off the flat side and lower

    surfaces of the unit.

    Easy-clean, flat surfaces

    Non-dew flap without bristles

    Long-life filter lasts about half

    year * maintenance not required

    Diffuses comfortable airthroughout the room

    Auto-swing (up&down) brings comfort to the room.

    Installation flexibility forfreedom of design

    Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, tofurther improve comfort level, closer to the target area at the wired remotecontrol. This feature must be set during commissioning by the technicians.

    Dehumidification is microprocessor controlled to prevent abrupt and

    uncomfortable changes in air temperature.

    Programme "Dry"

    Wide air discharge

    openings produce aspreading 100 airflow

    Air is blown up to 50 in

    the downward direction.

    Switchable fan speed: High/Middle/Low

    Installable on

    ceilings 3.5 m high

    100

    Flexible installation

    *Water used in the test-run can now be drained from theair discharge opening rather than from the side as wasformerly the case.

    The unit fits more snugly into tightspaces.

    Drain pump kit (option)

    can be easily incorporated

    Drain pipe connection can be doneinside the unit. refrigerant and drain

    pipe outlets are at the same

    opening.

    Uniform height and

    depth. Compact

    design for small-

    capacity models to

    meet tighterdimensional

    1,160 mm30 mm or more

    30 mm or more

    For 71BV indoor unit

    Note : Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhat higherowing to ambient conditions.

    dB(A)

    Pipes more easily rigged, tooPlastic panels are used to conceal piping holes. Holes can be easily

    punched out without requiring special tools.

    Low gas pressure detection

    All wiring and internal servicing can be done from under the unit

    (Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units)

  • 8/9/2019 Daikin Skyair

    14/40

    Control featuresWork & ServicingComfort OthersOption

    CEILING MOUNTED BUILT-IN TYPE

    Clever and compact mini ducted unitprovides comfort and flexibility.Clever and compact mini ducted unitprovides comfort and flexibility.

    Features

    Feature

    Model

    Cooling only

    FBQ50B/60B/71B

    *1Applicable when wired remote controller is used

    FBQ50BV1A

    BRC4C62

    A signal receiver must be added to the indoor unit.

    Wireless remote controller and signal

    receiver unit are sold as a set.

    Wireless LCD remote controller

    Signal receiver unit

    (Separate type)

    13

    *1 Switchablefans

    peed

    Programme"Dry"

    Year-roundcooling

    applicable

    Timerselector

    Prechargedfor

    upto10m

    Filtersign

    Self-d

    iagnosisfu

    nction

    Lowg

    aspressure

    detection

    PEfin

    Highefficiencyfilteroption

    Controlby2rem

    ote

    controllers

    Auto-restart

    Controlby1rem

    ote

    controller

    Externalcomma

    nd

    control

    Centralremote

    control

    Interlockcontrol

    Twoselectable

    temperature-sensors

    Note: Remote controller cable not included. Cables must be procured locally.

    BRC1E61

    Navigation RemoteController(Wired Remote Controller)

    Note: Remote controller cable not

    included. Cables must be

    procured locally.

    Wired LCD remote controller

    Wired LCD remotecontroller with weeklyschedule timer

    BRC1C61

    BRC1D61

    Accessory required for indoor unit

    Option

  • 8/9/2019 Daikin Skyair

    15/40

    CompactCompact design of built-in type helps blend

    with interior decor.

    Work & Servicing

    Comfortable

    Height reduced to allow installation in confined spaces.

    Flexibly adapts to shop interiors

    L-shaped space U-shaped space Long space

    To cope with the challenges of L-shaped or U-shaped spaces, itis possible to install the air discharge unit away from the main unit.At the same time, different types of architectural space can be

    kept comfortable.

    The height of the unit is a mere 300* mm. It can be

    installed in a narrow ceiling space.(when access panel is used.)

    Provided with condensate drain pump, waking drainpiping easier in awkward spaces.

    External static pressure can be set depending onduct length, presence of high-efficiency filter, andother installation conditions.

    Access panel

    250mm

    Access panel

    300

    mmm

    300mm

    Two selectable temperature-sensors

    *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from

    another room. **Wireless remote controller does not have a temperature-sensor.

    Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61))

    contain temperature-sensors. Temperature sensing can be set atthe unit or, to further improve comfort level, closer to the target areaat the wired remote control.This feature must be set during commissioning by the technicians.

    (mm)

    71B 34 30

    60B 34 30

    Indoor unit High Low

    50B 33 29

    30060B/71B

    1,000

    800

    HeightIndoor unit

    Width

    Depth

    700

    50B

    Quiet operation

    Dehumidification is microprocessor controlled to prevent abrupt

    and uncomfortable changes in air temperature.

    Programme "Dry"

    Switchable fan speed: High/Low

    dB(A)

    Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.During operation these values are somewhat higher owing to ambient conditions.

    *350mm high with 100B8-125B8.

    High Standard

    88

    Indoor unit

    External static pressure pattern

    50B71B 49 20

    Low

    External static pressure is set to standard when the unit is shipped from the factory.

    (Pa)

    14

  • 8/9/2019 Daikin Skyair

    16/40

    Control featuresWork & ServicingComfort OthersOption

    DUCT CONNECTION MIDDLE HIGH STATIC PRESSURE TYPE

    Flexible use of space is made possible usingducts to create a room filled with comfort.Flexible use of space is made possible usingducts to create a room filled with comfort.

    Features

    Feature

    Model

    Cooling only

    *1Applicable when wired remote controller is used*2Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units

    15

    *1 *2 *2 *2Switchablefans

    peed

    Programme"Dry"

    Year-roundcooling

    applicable

    Timerselector

    Prechargedfor

    upto30m

    Filtersign

    Self-diagnosisfu

    nction

    Lowg

    aspressure

    detection

    PEfin

    Highefficiencyfilteroption

    Controlby2rem

    ote

    controllers

    Auto-restart

    Controlby1rem

    ote

    controller

    Externalcomma

    nd

    control

    Centralremote

    control

    Interlockcontrol

    Twoselectable

    temperature-sensors

    FBQ71D/100D/125D/140D

    NEW

    BRC4C62A signal receiver must be added to the indoor unit.

    Wireless remote controller and signal

    receiver unit are sold as a set.

    Wireless LCD remote controller

    Signal receiver unit

    (Separate type)

    Note: Remote controller cable not included. Cables must be procured locally.

    BRC1E61

    Navigation RemoteController(Wired Remote Controller)

    Note: Remote controller cable not

    included. Cables must be

    procured locally.

    Wired LCD remote controller

    Wired LCD remotecontroller with weeklyschedule timer

    BRC1C61

    BRC1D61

    Accessory required for indoor unit

    Option

  • 8/9/2019 Daikin Skyair

    17/40

    Increased freedom of designthanks to variable controlover external static pressure

    Comfort airflow achieved in accordance withconditions such as duct length.

    Using a DC fan motor, the external static pressure can becontrolled within a range of 50 Pa to 200 Pa.

    Thin, lightweight indoorunit makes delivery andinstallation easy.

    With a height of only 300 mm, installation is

    possible even in buildings with narrow ceiling

    spaces.

    Drain pump is equipped as standard accessory

    with 700 mm lift.

    300

    100D 125D 140D

    1,000

    36

    1,400

    700

    Height

    Indoor unit

    Width

    Depth

    46Machine Weidth

    71D

    16

    Freely control external static pressure

    50 Pa 200 Pa

    Set to high static pressure for

    advanced needs such as when

    using dampers and long ducts.

    Set to low static

    pressure when ducts

    are short.

    Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)

    Ventilation grille

    Door-installedventilation grille

    Ventilation grille

    Wall-installedventilation grille

    Under-door cutout

    Under-door cutoutWhen air conditioning two roomssimultaneously, the air discharged into eachroom must be circulated back to the air

    conditioner. To achieve this, a ventilationduct should be installed for each room or oneof the indicated ventilation grilles should beinstalled on the partitioning wall or under thedoor between the rooms.

    Ventilates air through

    the partitioning wall.

    (See right)

    Partitioning wall

    Note: The under-door cutout method should be used only when there is a small volume of airflow.

    (mm)

    (mm)

    (mm)

    (kg)

    Quiet operation

    When testing standard integrated ceiling units that employ ductwork, much time used to be required to adjust airflow to the rightlevel. Thanks to the ability provided by Daikin to automatically

    perform this troublesome adjustment using a remote controller,this step is now quick and easy. (Adjust by H tap .)

    1. Adjust to approximately 10% of the rated H tap airflow.2. Once actual operation has begun, adjustment of the rated airflow is not possible.

    Reduced installation time

    Use remote controller to adjust airflow

    Anti bacterial treatment, that includes silver ions is used which

    may assist in preventing the growth of microorganisms that cause

    smells and clogging.

    Bactericidal treatment for drain pan

    Maintenance is easy because the drain pan can be removed.

    Easy maintenance

    Clean

    Both indoor unit and wired remote controller (option) containtemperature- sensors. Temperature sensing can be set at the unitor, to further improve comfort level, closer to the target area at thewired remote control.This feature must be set during commissioning by the technicians.

    *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from anotherroom.

    **Wireless remote controller does not have a temperature-sensor.

    Two selectable temperature-sensors

    Comfortable

    dB(A)

    300

    100D 125D 140D

    High

    Low

    71D

    38 40 4037

    33 36 3632

    700 mm

    300mm

  • 8/9/2019 Daikin Skyair

    18/40

    OUTDOOR UNIT

    The final word ininverter technology

    RZR100KUV1

    RZR125KUV1RZR140KUV1

    RZR71KUV1

    Easy installation and maintenance

    Pre charged for up to 30 metres

    4-direction piping offers greaterlayout freedom

    50 mpiping length

    Easy centralised installation with

    the module oriented design

    Separationavailable

    -10

    0

    10

    20

    30

    40

    50

    46CDB

    Cooling

    -5CDB

    Outdoor temp(CDB)

    Depth of 71KU, 100-140KU, 100-140HU,are standardised as 320 mm. Horizontalcontinuous mounting is available.

    If refrigerant piping length does not exceed30 m, there is no need for on-site gascharging.

    A pump-down switch is provided to make iteasier to collect refrigerant if the unit is tobe moved or layout modified.

    Facilitates pump down(Refrigerant recovery function)

    Effective gas monitoring reduces the laborrequired for operation, maintenance, andrepairs.

    Low gas pressure detection

    function

    Operation range

    Reduced installation work thanks to light,compact outdoor unit.

    Space saving

    Compact design with reduced height

    The maximum capacity is maintained

    within a set level of power consumption,

    which makes it possible to keep comfort

    and effective demand control.

    The outer panel for the piping connectionpart of the front, right side and backsidecan be removed and is easier for post-installation piping work.

    17

    Fittings can be mounted on the fourlocations, right/ left on front and back sideof the outdoor unit.

    Reinforcing wire fittings

    (option) are available

    Safety

    As the bottom frame is

    subject to corrosion,

    corrosion-proof galvarium

    steel plate is adopted toenhance the durability.

    Heat exchange fins provided

    with anti-corrosion treatment

    Durability

    Construction

    Non-treated fin

    PE fin

    Aluminium

    AluminiumCorrosion resistantacrylic resin

    Hydrophilic film

    Allowed refrigerant piping length

    and level difference

    Max. lengthMax. level

    difference

    Pre charged1

    30 m30 m71KU

    30 m100HU

    50 m(Equivalent length 70m)

    30 m125HU

    50 m(Equivalent length 70m)

    50 m(Equivalent length 70m)

    50 m(Equivalent length 70m)

    30 m30 m

    30 m

    30 m

    30 m125KU

    30 m140KU

    50 m(Equivalent length 70m)

    50 m(Equivalent length 70m)

    30 m

    30 m

    100KU

    30 m140HU

    Note :1Additional refrigerant charging is required if the

    refrigerant pipe is longer than the length.

    30 m 50 m(Equivalent length 70m)

    8:00 12:00 16:00 20:00

    Power

    consumption

    Time

    Limitation

    Demand Control Function

    * Required for KRP58M51 (Option)

    (Applicable to RZR100140KU, 100140HU outdoor units)

    (Compared to RZQ100-160PV4A)

    RZR100HUY1

    RZR125HUY1RZR140HUY1

    RZR71KUV1 RZR100KUV1

    71KU

    900 mm

    320 mm

    Suction

    Discharge

    900 mm

    100KU100HU

    125KU125HU

    900 mm 900 mm

    140KU140HU

  • 8/9/2019 Daikin Skyair

    19/40

  • 8/9/2019 Daikin Skyair

    20/40

    Clear Display

    LCD REMOTE CONTROLLER

    Easy-to-read LCD remote controller allows vario

    can control multiple indoor units.Remote controller options are shown on the page introducing each indoor unit model.

    Necessary optional accessory

    19

    Navigation Remote Controller(Wired Remote Controller BRC1E61)

    Clear display,

    Simple operation,

    "Navigation

    Remote Controller"!This simple, modern designed remote

    controller with fresh white colour matches

    your interior design. Operation is much easier

    and smoother, just follow the indications on

    the navigation remote controller.

    A combination of fine dots enables various iconsand texts to be displayed smoothly. Large text

    display improves readability.

    Equipped

    backlight helps

    operating in dark rooms.

    The schedule timer for each

    day of the week can be setup easily.

    Display is available in 10

    languages.(English, German, French, Spanish,

    Italian, Portuguese, Greek, Dutch,

    Russian and Turkish).

    Dot matrix display

    Backlight display

    Other Features

    Weekly schedule timer Multilingual display

    Large buttons and arrows keysfor easy operation. Basic

    settings such as fan speed and

    temperature can be intuitively

    operated. For other settings

    just select the function from the

    menu list.

    The display gives an

    explanation of each setting

    for easy operation.

    Simple operation

    Large buttons and arrow keys

    Guide on display

  • 8/9/2019 Daikin Skyair

    21/4020

    s system control configurations and

    Enables temperature sensing closer to targetarea for improved comfort. (When using remotecontrol from another room, temperature-sensor inindoor unit's air inlet must be selected.)

    Facilitates maintenance and repair

    All initial settings can be set from the remotecontroller. After interior construction is complete,

    ceiling mounted cassette type can be remotelyset without having to use stepladder access formanual setting.Setting contents: High ceiling use, air direction, filter type, address

    for centralised control (group control address is set automatically).

    Remote controller is equipped with model nameand failure display functions. This facilitatesservice in the unlikely event of a malfunction.

    SkyAir shares common control withHRV (heat reclaim ventilation) and

    the other Daikin air-conditioningunits, thus simplifying interlockingoperations.

    Easily adaptable to large-scale, high-function,centralised remote control systems.Installing and connecting control wiring betweenSkyAir and other Daikin air-conditioningequipment is easy.

    LCD panel shows operating status in letters, numbers, and motion.

    Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.

    Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).

    Programming time displayOperation start and stop time can be set for individual timers up to 72 hours. The LCD also shows

    when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.

    Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

    Indoor units applicable for the remote controllerSignal receiver unit is contained inside decoration panel or indoor unit

    CEILING MOUNTED CASSETTE TYPE

    COMPACT MULTI FLOW TYPE

    CEILING MOUNTED BUILT-IN TYPE

    CEILING SUSPENDED TYPE

    BRC7E531W

    BRC7F632F

    BRC4C62

    DUCT CONNECTION MIDDLE HIGH STATIC PRESSURE TYPE BRC4C62

    BRC7EA66

    LCD wireless remote controller

    Note: The signal receiver unit shown in the

    photograph is for mounting inside

    the decoration panel of the ceiling

    mounted cassette type.Wireless remotecontroller

    Light receptor mounted type

    BRC7F632F

    The wireless remote controller is

    supplied in a set with a signal

    receiver.

    Shape of signal receiver unit

    differs according to the indoor

    unit.Signal receiver unit(For ceiling mountedcassette type)

    Easier to read because LCD screen is larger.

    Wired LCD remote controller

    BRC1C61

    For easier operation, louver switches, which

    are frequently used, have been made larger.

    Oil-resistant plastic casing.

    Only 17 mm thick. Can be installed either

    recessed or exposed.

    Remote control is equipped with weekly timer function.

    Wired LCD remote controller with weekly schedule timer

    BRC1D61

    24-hour clock function.

    Programming function for each day of week.

    Scheduling possible of start/stop and

    temperature limit (5 settings/day).

    Wired remote controller hasbuilt-in temperature-sensor(Applies to wired remote controllers (BRC1D61,BRC1E61))

    (Applies to wired remote controller (BRC1E61))

  • 8/9/2019 Daikin Skyair

    22/40

    LCD REMOTE CONTROLLER

    Central remote controller

    Interface adaptor for SkyAir series

    Easily adaptable to large-scale, high-function, centralised remote control system.

    Centralised control, with setting assimple as it is with a standard

    remote controller, of up to 64 groups(1,024 indoor units) is possible.

    DCS302CA61(Option)

    DTA112BA51(Option)

    With its high functionality, the fullcolour all-in-one graphic controller

    facilitates management of SkyAirSystem in a variety of ways.

    DCS601C51(Option)

    Unified on/off controller

    Centralised control of on/off bygroup or all at once for up to 256

    indoor units.

    DCS301BA61(Option)

    Schedule timer

    Unified control of weekly schedulefor up to 1,024 indoor units.

    DST301BA61(Option)

    Schedule timer sets on/off time in 1 minute unitsto be executed twice a day for a week at a time.

    *Please refer to the page 29 for the details.

    Simple system provides a diverse assortment of control modes.

    Control by 1remote controller

    Control pattern Wired remote controller Wireless remote controller

    Control by 2remote controllers

    Group control

    Control byexternal command

    Centralised remotecontrol

    Interlock controlwith HRV

    (Basic system)

    Link by remotecontroller group control.

    Zone link control bycentralised control.

    For control from 2locations such as inroom and control room,exits, etc.

    For simultaneouscontrol of up to 16indoor units.

    Centralised control ofup to 64 indoor groupsfrom remote locationup to 1 kilometer away.

    Control by 1 wireless remotecontroller and 1 wired remotecontroller (See note 1)

    Signal receiver unit installedon indoor unit

    Signal receiver unit installedon indoor unit

    HRV for indoor units within a zone are operated by interlockingCan also be operated independently by remote controller.

    Central remote controller (option)

    HRV

    Can be operated simultaneouslyor independently by remote controller(set by ventilation mode)

    HRV

    Central remote controller (option)

    Non-polar, double-core(max. wiring length 500 m)

    Connects 2 wiredremote controllers

    Automatic address setting function Automatic address setting function

    Signal receiver unit installedon 1 indoor unit

    Optional wiring adaptor for

    electrical appendices is necessary

    Central remote controller (option)

    Can be operated simultaneouslyby remote controller(set by ventilation mode)

    HRV

    HRV for indoor units within a zone are operatedby interlocking

    Central remote controller (option)

    HRV

    Operation andsurveillance is carried out

    using the contact signalfrom the operation controlbox in the buildingsurveillance (security)room.

    Optional wiring adaptor for

    electrical appendices is necessary

    Optional SkyAir series interfaceadaptor required. 1

    Optional SkyAir series interfaceadaptor required. 1

    Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.1

    The ceiling mounted cassette type come standard with an interface adaptor for SkyAir series (DTA112BA51).

    Enables centralised control via connectionto a high-speed, DIII-NET communicationsystem, adopted for the Daikin VRV system.Necessary for interface adaptor for SkyAir series with the

    central remote control units shown at above.

    The interface adaptor for the Skyair series isoptional except for the ceiling mounted cassettetype.

    21

  • 8/9/2019 Daikin Skyair

    23/4022

    Use the temperature-sensor in theindoor unit when controlling airconditioning from another room.

    Temperature-sensors are included in the indoor unit andoptional wired remote controller. Temperature sensingcloser to target area is possibleto further increase the comfortlevel.

    Note: Wireless remote controllers have notemperature-sensor.

    To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acrylpretreatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.

    Abundance of functions that provide comfortable

    air-conditioning in stores and offices.Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

    PE fin

    O t h e r s

    Air discharge direction angle canbe set (fixed setting)

    Dehumidification is microprocessor controlled to preventabrupt and uncomfortable changes in air temperature. Usefulfor reducing uncomfortable humidity without uncomfortablecooling of the room.

    Sanitary filter has mould-resistant treatment. Mould-proofing maintains hygiene by preventing growth inhighly humid conditions.

    Delivers comfortable air-conditioning to all areas,near to and far from the air-conditioner.

    High setting provides maximum reach while low settingminimises drafts.

    Auto-swing

    Programme "Dry" with a humidity sensor

    Mould-resistant treatment for filter Mould-proofing drain pan

    Switchable fan speed

    (1) Air direction instandard position

    (2) Air direction in ceilingsoiling preventionposition

    (standard, ceiling soiling prevention) Note:When units are installed on high ceilings, depending on the model, various restrictions

    concerning maximum height, air discharge direction, and choice of options may apply.You can freely set 2 air discharge positions by remote controller.

    Swing pattern selection

    Delivers air-conditioning comfort all the way down to the floorin air-conditioning zones with high ceilings.

    High-ceiling application

    Efficient cooling even in winter when indoor temperatures arehigher than those outside, such as in underground publicspaces or offices with many computers.

    The year-round cooling kit is required as option.

    Year-round cooling applicable

    Operation starts when the preset time of the ON timer elapsesand stops when the preset time of the OFF timer elapses.

    Timer selector

    Two selectable temperature-sensors

    C o m f o r t

    Mould prevention

    *available on all models.

    *available on all models.

    *available on all models.

  • 8/9/2019 Daikin Skyair

    24/40

    If there is a malfunction elsewhere in the system, the fan orcompressor can still be operated.

    Insufficient gas charging is normally hard to detect. Duringpost-installation trials and regular inspection procedures, therefrigerant level is monitored by microprocessor to maintainproper gas pressure. Reliability is assured and maintenanceand inspection can be carried out more quickly.

    You can turn up to 16 indoor units on/off with a single remotecontroller. (When using connected indoor units, the settingsmust all be the same and on/off will be simultaneous.)

    Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

    Emergency operation

    Low gas pressure detection

    Control by 1 remote controller

    Operation and surveillance is carried out using the contact

    signal from the operation control box in the buildingsurveillance (security) room.

    External command control

    Optional central remote controller enables centralised controlof up to 1024 indoor units (64 groups) from up to 1 kilometeraway.

    Central remote control

    Enables interlocking control with external equipment such asheat reclaim ventilation (HRV).

    Interlock control

    The operating parameters of indoor and outdoor units, andsensor data at critical locations throughout the system, areconstantly monitored using a microcomputer. To facilitatequick response in the event of a malfunction, a messageappears on the LCD of the remote controller and an LED onthe unit illuminates.

    Self diagnosis function

    Two types are available: 65% and 90% colorimetry.

    High-efficiency filter unit

    You can provide air-conditioning with fresh air from outside.Convenient for places where a ventilation fan cannot beinstalled.

    Fresh-air intake kit

    Work and Servicing

    Control features

    Options

    Steeper gradient realises moreefficient condensate drainage.High-lift is especially useful forlong lengths of drain piping.

    Maintenance is not required for one year (two years when aceiling mounted cassette type is used).

    If refrigerant piping length does not exceed 30 m, there is noneed for on-site gas charging.

    The filter sign warns you when it is time to clean the filter.

    *When using a wired remote controller the sign is displayed in the LCD. When using a

    wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

    Drain pump mechanism

    Long-life filter

    Pre charged for up to 30 metres

    Filter sign

    Daikin's innovative air discharge mechanism keeps airflowaway from the ceiling. Ceiling cleaning is less frequentlyrequired.

    Ceiling soiling prevention function

    If there is a power outage while the equipment is operating,

    operations will restart in the same mode as before the powercut when electricity is restored.

    Ultra long-life filter

    Auto-restart

    Using 2 remote controllers you can operate the equipmentlocally or from a remote location.

    Note: When a wireless remote controller is used, remote control by two remote controllers is

    not possible.

    Control by 2 remote controllers

    RXS50FA/60F/71F, RKS25A/35A/50A/60A : 10 m

    *Applicable to RZR71-140KU, RZR100-140HU.

    Requires no maintenance for about 4 years* (10,000h) instores and offices.

    *For dust concentration of 0.15 mg/m3

    *Required for KRP58M51 (Option)

    *available on all models.

    *available on all models.

    *Connecting ducts, insect nets, fire dampers, air filters, and other partsshould, as required, be procured locally.

    **Outside Air fan interlocked with air conditioning unit is necessary. OptionalPCB(KRP1C63)is required for interlocking.

    ***It is recommended that the volume of outdoor air introduced through the kit

    is limited to 10% of the maximum airflow rate of the indoor unit. Introducinghigher quantities will increase the operating noise and may also influencetemperature sending.

    Note:

    23

  • 8/9/2019 Daikin Skyair

    25/40

  • 8/9/2019 Daikin Skyair

    26/40

    CEILING SUSPENDED TYPE

    Note :1Rated cooling capacities are based on the following conditions: Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB Equiv. refrigeration piping, 7.5 m (horizontal).

    2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

    35 50 60

    1 Phase, 220240 V, 50 Hz 1 Phase, 200240 V, 50 Hz

    37/32

    195X960X680

    24

    38/33

    195X960X680

    25

    39/33

    195X1,160X680

    27

    5.0(1.7-5.6)

    5.7(1.7-6.0)

    1.72 2.00

    3.4(1.2-3.7)

    1.05

    White

    14 to 28

    1.1 1.1

    1.5 (Charged for 10 m)

    VP20 (I.Do/20XO.Do/26) VP20 (External dia.26,internal dia.20)

    47 49

    735X825X300 735X825X300

    47

    10 to 46

    47

    o/6.4

    o/12.7

    30 30

    o/6.4

    o/12.7

    20

    47

    550X765X285

    34

    1.0 (Charged for 10 m)

    0.6

    Ivory white

    20

    15

    Hermetically sealed swing type

    o/6.4

    o/9.5

    o/18.0 (Hole) o/18.0 (Hole) o/18.0 (Hole)

    CWB

    kW

    kWPower consumption

    CDBCertified operation range

    Certified operation range

    Motor output

    Compressor

    Model

    Name

    Indoor unit

    Outdoor unit

    Dimensions (HXWXD)

    Colour

    mm

    dB(A)

    kW

    Refrigerant charge (R-410A) kg

    dB(A)Sound level2

    Dimensions (HXWXD) mm

    Machine weight kg

    Piping

    connections

    mmLiquid (Flare)

    mmGas (Flare)

    mmDrain Indoor unit

    Outdoor unit

    Machine weight kg

    Airflow rate (H) m3/min 13/10 17/1313/10458/353 600/458458/353

    Outdoor

    unit

    Colour

    mm

    Heat insulation

    Max. interunit piping length m

    mMax. installation level difference

    Power supply

    Type

    Sound level (H/L)2

    Indoorunit

    FHQ35BVV1B FHQ50BVV1B

    RKS35AVMG RKS50AVMG

    FHQ60BVV1B

    RKS60AVMG

    Both liquid and gas piping

    Cooling capacity1

    Rated (Min. - Max.)

    cfm

    71 100 125

    FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B

    RZR71KUV1 RZR100KUV1 RZR125KUV1

    39/35 42/37 44/39

    195X1,160X680 195X1,400X680 195X1,590X680

    o/9.5

    o/15.9

    770X900X320

    61

    o/9.5 o/9.5

    o/15.9 o/15.9

    1,170X900X320 1,170X900X320

    92 97

    32

    -5 to 46

    14 to 28

    35

    Hermetically sealed scroll type

    27

    30

    48 49 50

    50 (Equivalent length 70)o/26.0 (Hole)

    1.7

    1.75 (Charged for 30 m)

    17/14 24/20 30/25600/494 847/706 1,059/883

    10.0(5.0-11.2)

    12.5(5.7-14.0)

    o/26.0 (Hole) o/26.0 (Hole)

    2.1 2.6

    2.4 (Charged for 30 m) 3.7 (Charged for 30 m)

    3.51 4.552.50

    7.1(3.2-8.0)

    CEILING SUSPENDED TYPE

    3 Phase, 380415 V, 50 Hz

    VP20 (External dia.26,internal dia.20)

    Ivory white

    CWB

    kW

    kWPower consumption

    CDBCertified operation range

    Certified operation range

    Motor output

    Compressor

    Model

    Name

    Indoor unit

    Outdoor unit

    Dimensions (HXWXD)

    Colour

    mm

    dB(A)

    kW

    Refrigerant charge (R-410A) kg

    dB(A)Sound level2

    Dimensions (HXWXD) mm

    Machine weight kg

    Pipingconnections

    mmLiquid (Flare)mmGas (Flare)

    mmDrain Indoor unit

    Outdoor unit

    Machine weight kg

    Airflow rate (H/L) m3/min

    Outdoor

    unit

    Colour

    mm

    Heat insulation

    Max. interunit piping length m

    mMax. installation level difference

    Power supply

    Type

    Sound level (H/L)2

    Indoor

    unit

    Both liquid and gas piping

    Cooling capacity1

    Rated (Min. - Max.)

    cfm

    100 125

    FHQ100BVV1B FHQ125BVV1B

    RZR100HUY1 RZR125HUY1

    42/37 44/39

    195X1,400X680 195X1,590X680

    o/9.5 o/9.5o/15.9 o/15.9

    1,345X900X320 1,345X900X320

    94 104

    32 35

    Hermetically sealed scroll type

    30

    49 50

    50 (Equivalent length 70)

    24/20 30/25

    847/706 1,059/883

    10.0

    (5.0-11.2)

    12.5

    (5.7-14.0)

    o/26.0 (Hole) o/26.0 (Hole)

    2.1 2.6

    3.9 (Charged for 30 m) 4.3 (Charged for 30 m)

    White

    3.51 4.55

    14 to 28

    -5 to 46

    25

    SPECIFICATIONS

  • 8/9/2019 Daikin Skyair

    27/4026

    1 Phase, 220240 V, 50 HzPower supply

    6050 71

    CEILING MOUNTED BUILT-IN TYPE

    Model

    Name

    Indoor unit

    Outdoor unit

    kW

    FBQ50BV1A

    RXS50FAVMA

    FBQ60BV1A

    RXS60FVMA

    FBQ71BV1A

    RXS71FVMA

    5.0(1.7-5.6)

    CDBCooling

    CWBCooling

    Cooling

    Cooling

    Certified Operation range

    Certified Operation range

    Motor outputCompressor

    Indoor

    unit

    Dimensions (HXWXD)

    Colour

    mm

    dB(A)

    kWRefrigerant charge (R-410A)

    Sound level3

    Cooling (H/L)Sound level3

    dB(A)

    Dimensions (HXWXD) mmMachine weight kg

    Pipingconnections

    mmLiquidmmGasmmDrain Indoor unit

    Machine weight kg

    kg

    Airflow rate(H/L)

    Fan

    Outdoorunit

    Colour

    Heat insulation

    Max. interunit piping length mmMax. installation level difference

    Type

    300X700X800

    34

    33/29

    47

    735X825X300 735X825X300 770X900X320

    48

    ----------

    o/6.4

    o/12.7

    o/6.4

    o/12.7

    o/6.4

    o/15.9

    o/18.0 o/18.0

    10 to 46

    3020

    Both liquid and gas piping

    VP25 (I.Do/25XO.Do/32)

    mmOutdoor unit

    Ivory white

    Hermetically sealed swing type

    1.1

    1.5 (Charged for 10 m)

    kWCoolingPower consumption 1.98

    5.7(1.7-7.0)

    300X1000X800

    Pa 88-49-20 88-49-20

    41

    14 to 28

    34/30

    49

    48

    1.1

    1.5 (Charged for 10 m)

    2.23

    6.7(2.3-8.0)

    300X1000X800

    88-49-20

    41

    34/30

    cfm 459/318 636/459 636/459

    52

    Night quiet mode dB(A) ---------- ---------- ----------

    71

    1.92

    2.3 (Charged for 10 m)

    2.57

    External static pressure2

    (High-Standard-Low)

    o/18.0

    Cooling capacity1

    Rated (Min. - Max.)

    m3/min 13/9 18/13 18/13

    1 Phase, 220240 V, 50 Hz 3 Phase, 380415 V, 50 HzPower supply

    10071 125

    DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE

    Note :1(FBQ50B-71B) :Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal) (FBQ100B-125B):Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 5 m (horizontal) (FBQ71D-140D) :Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal)2Initial setting is standard.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.4In case of drain piping for outdoor unit, drain piping kit (option) is needed.

    Model

    Name

    Indoor unit

    Outdoor unit

    kW

    FBQ71DV1

    RZR71KUV1

    FBQ100DV1

    RZR100KUV1

    FBQ125DV1

    RZR125KUV1

    7.1

    (3.2-8.0)

    CDBCooling

    CWBCooling

    Cooling

    Cooling

    Certified Operation range

    Certified Operation range

    Motor output

    Compressor

    Indoorunit

    Dimensions (HXWXD)

    Colour

    mm

    dB(A)

    kWRefrigerant charge (R-410A)

    Sound level3

    Cooling (H/L)Sound level3

    dB(A)

    Dimensions (HXWXD) mm

    Machine weight kg

    Pipingconnections

    mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

    Machine weight kg

    kg

    Airflow rate(H/L)

    Fan

    Outdoorunit

    Colour

    Heat insulation

    Max. interunit piping length m

    mMax. installation level difference

    Type

    300X1,000X700

    36

    770X900X320 1,170X900X320 1,170X900X320

    61

    ----------

    o/9.5

    o/15.9

    o/9.5

    o/15.9

    o/9.5

    o/15.9

    o/26 (Hole) o/26 (Hole)

    50 (Equivalent length 70)

    Both liquid and gas piping

    I.Do/25XO.Do/32

    mmOutdoor unit4

    Ivory white

    Hermetically sealedswing type

    1.5

    1.75 (Charged for30 m)

    kWCoolingPower consumption

    10.0

    (5.0-11.2)

    300X1,400X700

    Pa

    46

    92

    1.8

    2.4 (Charged for 30 m)

    12.5

    (5.7-14.0)

    300X1,400X700

    46

    cfm 635/530 1,130/812 1,377/988

    Night quiet mode dB(A)

    97

    2.4

    3.7 (Charged for 10 m)

    External static pressure2

    (High-Standard-Low)

    o/26 (Hole)

    Cooling capacity1

    Rated (Min. - Max.)

    100 125

    FBQ100DV1

    RZR100HUY1

    FBQ125DV1

    RZR125HUY1

    140

    FBQ140DV1

    RZR140HUY1

    10.0

    (5.0-11.2)

    46

    1,130/812

    12.5

    (5.7-14.0)

    1,170X900X320

    o/9.5

    o/15.9

    o/9.5

    o/15.9

    o/9.5

    o/15.9

    30

    Hermetically sealed scroll type

    300X1,400X700 300X1,400X700

    46

    300X1,400X700

    97

    -5 to 46

    1,345X900X320

    94

    2.9 1.6

    3.7 (Charged for 30 m) 3.9 (Charged for 30 m)

    1,345X900X320

    104

    2.3

    4.3 (Charged for 30 m)

    140

    FBQ140DV1

    RZR140KUV1

    14.0

    (6.25-15.4)

    46

    14 to 28

    1,377/988

    m3/min 18/15 32/23 39/28 32/23

    1,377/988

    39/2839/28

    o/26 (Hole) o/26 (Hole) o/26 (Hole)

    14.0

    (6.25-15.4)2.22 3.13 3.97 3.13 3.974.75 4.75

    o/9.5

    o/15.9

    46

    37/32 38/33 40/36 38/33 40/3640/36 40/36

    300X1,400X700

    1,345X900X320

    104

    2.8

    4.3 (Charged for 30 m)

    48 49 50 49 5050

    46

    50

    1,377/988

    39/28

    o/26 (Hole)

    NA

    47 49 45 49 45 46

  • 8/9/2019 Daikin Skyair

    28/40

    Indoor unit

    Touch Controller4 DCS601C51

    Note: 1Refer to page 8 for the details.2Required for installing high-efficiency filter or ultra long-life filter.3Wiring for wired remote controller to be procured locally.

    CEILING MOUNTED CASSETTE TYPEKit name

    DCS302CA61

    BRC1E61

    DCS301BA61

    DST301BA61

    KRP1C63

    KDDFP55H160

    KDBH55K160F

    KDBP55H160FA

    KKSJ55K160

    KDDP55K160

    KDDP55K160K

    KDDP55X160

    KRP4AA53

    KAFP551K160

    KAFP556H80

    KAFP557H80

    KAFP552H80

    KDTP55K80

    KDJP55H160KDJP55H80

    BRC7F632F

    BRC1D61

    KAFP553H80

    KDTP55K160

    KAFP556H160

    KAFP557H160

    KAFP552H160

    KAFP553H160

    BYCP125K-W1

    KRP1H98

    KAFP55H160

    KAFP55H160H

    FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEAName of option Remark

    Chambertype

    Decoration panel

    Fresh airintake kit1

    Central remote controller4

    Unified ON/OFF controller4

    Schedule timer4

    Adaptor for wiring5

    Without the T-joint pipe and fan

    With the T-joint pipe, without fan

    Direct installation type

    Sealing member of air discharge outlet

    Panel spacer

    Chamber connection kit2

    Insulation kit for high humidity

    Group control adaptor5

    Installation box for adaptor PCB

    High-efficiency filter

    Filter chamber

    Long-life filter

    Ultra long-life filter

    Replacement ultra long-life filter

    (Colorimetric method 65%)

    (Colorimetric method 90%)

    Replacementhigh-efficiency filter

    (Colorimetric method 65%)

    (Colorimetric method 90%)

    Remote controller

    Navigation Remote Controller

    Wireless type

    Wired type3

    Branch duct chamber

    Wired LCD remote controller with weekly schedule timer

    For each flow pattern all round, 4-way, 3-way, 2-way, branch duct connection the compatibility of each independently installed option(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.

    Round flow type: List of optional parts required to achieve different flow patterns

    4The indoor unit is equipped standardly with the interface for SkyAir series and an option is unnecessary.5Installation box for adaptor PCB (KRP1H98) is necessary.

    1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to checkwhether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.

    2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation.

    4

    It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.

    Panel/grille related

    Independently installable optional parts

    Operation control related

    Auxillary function related

    Filter related

    Optional accessory parts

    Independently installable optional partsOptional accessory parts

    Independently installable optional partsOptional accessory parts

    Panel spacer1

    Panel spacer1 o o ox o

    Wireless remote controller o o oo o

    Fresh air intake kit (direct mount) o o oo o

    x o o

    x

    x

    High-efficiency filter2

    Filter related Ultra-long-life filter2

    o o o

    x

    x

    Ultra-long-life filter2 o o o xx

    High-humidity operation kit

    Panel/grille related

    Operation control related

    Auxillary function related

    Panel spacer1

    Wireless remote controller

    Fresh air intake kit (direct mount)

    High-humidity operation kit

    All round flow 4-way flow

    o3 o3 xx o3

    o3 o

    x

    x

    xo o

    o3 o x

    x

    o o

    x o o x

    o3 o o xx

    3-way flow 2-way flow

    1-way branch / unit 3-way flowBranch duct1

    (Chamber type)

    (Round duct type)

    o o o4 xx o

    2-way branch / unit 2-way flow

    1-way branch / unit 2-way flow

    x o o4 xx o

    x o o4 xx o

    Branch duct connection

    Wirelessremote controller

    Fresh air intake kit(direct mount)

    High-efficiencyfilter2

    High-humidityoperation kit

    Ultra-long-lifefilter2

    Panel spacer1Wireless

    remote controllerFresh air intake kit

    (direct mount)High-efficiency

    filter2

    High-humidity

    operation kit

    Ultra-long-life

    filter2

    Panel spacer1Wireless

    remote controllerFresh air intake kit

    (direct mount)

    Fresh air intake kit (Chamber type)1,2 o o ox o

    Fresh air intake kit (Chamber type)1,2 o3 o xx o

    o

    o

    x

    o

    o

    o3

    o

    x

    x

    x

    o

    o

    o

    o

    Fresh air intake kit(Chamber type)1,2

    Fresh air intake kit(Chamber type)1,2

    Fresh air intake kit(Chamber type)1,2

    High-efficiencyfilter2

    High-humidityoperation kit

    Ultra-long-lifefilter2

    Remote sensor (for indoor temperature) KRCS01-4B

    OPTIONS

    27

  • 8/9/2019 Daikin Skyair

    29/40

    28

    ----------

    ----------

    ----------

    Touch Controller2

    Indoor unit

    Kit nameName of option

    FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B

    BRC7E531W

    BRC7EA66

    DCS302CA61

    DCS301BA61

    DST301BA61

    KRP1BA54

    KHFP5MA63KHFP5MA35

    KAF501DA80KAF501DA56

    KDU50N60VE

    Remark

    Kit nameName of option Remark

    Touch Controller3

    DCS601C51

    Note:

    Replacement long-life filter

    L-type piping kit (for upward direction)

    Drain-up kit

    Remote controller

    Resin net

    Wireless type

    Central remote controller2

    Unified ON/OFF controller2

    Schedule timer2

    Adaptor for wiring

    Wiring adaptor for electrical appendices3

    Interface adaptor for SkyAir series

    Installation box for adaptor PCB

    FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B

    Decoration panel

    Fresh air intake kit

    Central remote controller3

    Unified ON/OFF controller3

    Schedule timer3

    Adaptor for wiring2

    Direct installation type

    Wiring adaptor for electrical appendices2

    Sealing member for air discharge outlet

    Panel spacer

    Interface adaptor for SkyAir series

    Installation box for adaptor PCB

    Replacement long-life filter

    Remote sensor (for indoor temperature)

    DCS302CA61

    DCS301BA61

    DCS601C51

    DST301BA61

    KRP1BA57KRP4AA53

    KRCS01-1B

    BYFQ60B8W1

    Wired LCD remote controller with weekly schedule timer BRC1D61

    Wired LCD remote controller with weekly schedule timer BRC1D61

    Wired LCD remote controller with weekly schedule timer BRC1D61

    KDBHQ44B60

    KDBQ44B60

    KDDQ44X60

    DTA112BA51

    KRP1BA101

    KAFQ441B60

    Note: 1Wiring for wired remote controller to be procured locally. 2Installation box for adaptor PCB (KRP1BA101) is necessary. 3This optional accessory requires DTA112BA51.

    COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

    CEILING SUSPENDED TYPE

    1Wiring for wired remote controller to be procured locally.2This optional accessory requires DTA112BA51.3Installation box for adaptor PCB (KRP1CA93) is necessary.

    Remote controller Wireless type Cooling only

    FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B

    KRP4AA52

    DTA112BA51

    KRP1CA93

    KHFP5MA160

    KAF501DA112 KAF501DA160

    KDU50N125VE

    KRCS01-1B

    KJB311AA

    KJB212AA

    Remote sensor (for indoor temperature)

    Electrical box with earth terminal (3 blocks)

    Electrical box with earth terminal (2 blocks)

    BRC1E61Navigation Remote Controller Wired type1

    BRC1E61Navigation Remote Controller Wired type1

    FBQ50BV1A

    KTBJ25K56W KTBJ25K80W

    KDAJ25K56A KDAJ25K71A

    FBQ60BV1A FBQ71BV1A

    CEILING MOUNTED BUILT-IN TYPE

    Service access panel

    Air discharge adaptor

    Adaptor for wiring (interlock for fresh air intake fan)

    Group control adapter

    Interface adaptor for SkyAir series

    Remote controller Wireless type

    Kit nameName of option Remark

    Central remote controller2

    Unified ON/OFF controller2

    Schedule timer2

    Note:1Wiring for wired remote controller to be procured locally.

    2This optional accessory requires DTA112BA51.

    Touch Controller2

    KRP4AA51

    KRP1BA54

    DTA112BA51

    BRC4C62

    DCS301BA61

    DCS302CA61

    DST301BA61

    DCS601C51

    BRC1E61Navigation Remote Controller Wired type1

  • 8/9/2019 Daikin Skyair

    30/40

  • 8/9/2019 Daikin Skyair

    31/40

    DIMENSIONS

    CEILING MOUNTED CASSETTE TYPE

    (Unit: mm)

    Liquid pipe connection

    Gas pipe connection

    Drain pipe connection

    Power-source wiring and a unit wiring connection

    Connection wiring / remote control wiring connection

    Air-outlet

    Suction grille

    Corner decoration cover

    Drain hose (accessory)

    1

    2

    3

    4

    5

    6

    7

    8

    9

    Notes:1Sticking location for manufacture's labelmanufacture's label for indoor unit:Suction grille inner side's electric components box's lid surface

    manufacture's label for decoration panel :Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controllerin detail.

    3When the temperature and humidity in the ceiling exceed 30 C and RH 80% or the fresh air is inducted into the ceiling or the unitcontinues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.

    4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or lessbetween the indoor unit and the ceiling opening so that

    the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

    30

    [FCQ71KVEA]

    [FCQ71KVEA]

    [FCQ100-140KVEA]

    [FCQ71KVEA] [FCQ71KVEA]

    [FCQ100-140KVEA]

    [FCQ71-140KVEA] [FCQ71-140KVEA]

    [FCQ100-140KVEA]

    [FCQ100-140KVEA]

  • 8/9/2019 Daikin Skyair

    32/40

  • 8/9/2019 Daikin Skyair

    33/4032

    CEILING MOUNTED BUILT-IN TYPE

    DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE

    856

    Liquid pipe connectionGas pipe connection

    Drain pipe connection

    Interunit wiring port

    Power wiring port

    Drain hole

    Discharge flange

    suction flange

    Switch box

    Inspection hole

    12

    3

    4

    Notes:1Location of unit's Name Plate: Fan hosing surface.2If the ceiling is not removable, a 300 mm service spacemust be kept between the unit and the ceiling.3Mount the air filter at the suction side.(Select its colorimethod (Gravity method) 50 % or more)

    5

    6

    7

    8

    9

    10

    A B C D G

    833 6X120=720 1000 785FBQ60BV1A/71BV1A

    556 533 4X120=480

    F

    5X150=750

    3X150=450

    H

    11X65=715

    6X65=390

    I

    12X65=780

    7X65=455700

    E

    760

    460 485

    J

    1050

    750FBQ50BV1A

    [FBQ50BV1A, FBQ60BV1A, FBQ71BV1A]

    [FBQ71DV1]

    According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.

    1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)

    Notes:1Location of MANUFACTURE'S LABEL: Contro box surface2Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.)3Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works

    Liquid pipe connection

    Gas pipe connection

    Drain pipe connection

    Ground terminal

    (Terminal in Control box)

    Control box(Inside)Remote control wiring

    connection

    Power-source wiring and

    a unit wiring connection

    Air discharge flange

    Air suction flange

    Hook

    1

    2

    3

    4

    56

    7

    8

    9

    10

  • 8/9/2019 Daikin Skyair

    34/4033

    DIMENSIONS (Unit: mm)

    DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE

    [FBQ100DV1, 125DV1, 140DV1]

    According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.

    1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)

    Notes:1Location of MANUFACTURE'S LABEL: Control box surface2Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more.3Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works

    Liquid pipe connection

    Gas pipe connection

    Drain pipe connection

    Ground terminal

    (Terminal in Control box)

    Control box(Inside)

    Remote control wiring

    connection

    Power-source wiring and

    a unit wiring connection

    Air discharge flange

    Air suction flange

    Hook

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/9/2019 Daikin Skyair

    35/4034

    OUTDOOR UNIT // RKS25AVMG, RKS35AVMG

    OUTDOOR UNIT // RKS50AVMG, RKS60AVMG, RXS50FAVMA, RXS60FVMA

  • 8/9/2019 Daikin Skyair

    36/40

  • 8/9/2019 Daikin Skyair

    37/40

  • 8/9/2019 Daikin Skyair

    38/4037

    DIMENSIONS (Unit: mm)

    REMOTE CONTROLLER

    CEILING MOUNTED CASSETTE TYPE

    CEILING SUSPENDED TYPE

    CEILING MOUNTED BUILT-IN TYPE

    COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

    BRC1E61

    BRC1D61 / BRC1C61

  • 8/9/2019 Daikin Skyair

    39/4038

    Installation service space for outdoor unit

    1000

    ormo

    re

    200(30

    0)

    ormore

    LH

    L H

    H

    L

    500

    ormo

    re

    50(100)

    ormore

    L H

    For RZR71-140KUV1, RZR100-140HUY1

    200(30

    0)or

    more

    1000ormore

    200ormore

    100o

    rmore

    100ormore100o

    rmore

    50(100)o

    rmore

    1000

    ormore

    500o

    rmore

    When there is an obstruction on the inlet side

    When the obstruction on the outlet side is higher than

    the unit itself (There is no limit to the height of the

    obstruction on the outlet side.)

    When there are obstructions on both

    the inlet and outlet sides

    When there is an obstruction on the outlet side

    When there are obstructions

    on the inlet side and

    both lateral sides

    2. For series installation(more than two units)

    When there are

    obstructions on

    both sides

    When the overhead space is open

    1. For single unit installation

    When there is an

    obstruction only

    on the inlet side

    When there is an obstruction

    in the overhead space

    When the overhead space is open

    When there are obstructions

    on both sides

    When there is an obstructionin the overhead space

    When there is an

    obstruction on the

    inlet side

    When there are obstructions

    on the inlet side and

    both lateral sidesPattern 1

    2. For series installation (more than two units)

    1. For single unit installation

    1. For single unit installation

    When the overhead space is open

    2. For series installation(more than two units)

    1. For single unit installation

    2. For series installation (more than two units)

    1. For single unit installation

    2. For series installation (more than two units)

    100

    ormore

    500o

    rless

    1000ormore

    An obstructionin the overheadspace

    500o

    rless

    500o

    rmore

    1000ormore

    An obstructionin the overhead space

    500o

    rless

    1000

    ormore

    1000ormore

    An obstructionin the overhead space

    150

    ormore

    150ormore150ormore

    500o

    rless

    1000ormore

    An obstructionin the overheadspace

    200(30

    0)

    ormore

    1000ormore

    200ormore

    500o

    rless

    1000ormore

    An obstructionin the overheadspace

    (The unit values is mm. )

    The values represent the case for the RZR71-140KUV1 type. The values in ( ) are for RZR100 - RZR140HUY1 type.

  • 8/9/2019 Daikin Skyair

    40/40

    DealerHead Office:

    Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

    Kita-ku, Osaka, 530-8323 Japan

    Tokyo Office:

    JR Shinagawa East Bldg., 2-18-1, Konan,

    1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

    Cautions on product corrosion

    Warning Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the

    world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a

    particular country. Prior to purchase, please therefore confirm with your local authorised importer,

    distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for

    use, in the region where the product will be used. This statement does not purport to exclude, restrict

    or modify the application of any local legislation.

    Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.

    Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

    Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or

    contractor to install those parts and accessories. Use of unauthorised parts and accessories or

    improper installation of parts and accessories can result in water or refrigerant leakage, electrical

    shock, fire or explosion.

    Read the User's Manual carefully before using this product. The User's Manual provides important

    safety instructions and warnings. Be sure to follow these instructions and warnings.

    If you have any enquiries, please contact your local importer, distributor and/or retailer.

    JMI-0107 JQA-1452

    Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION

    Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OFCOMMERCIAL AIR CONDITIONING, HEATING, COOLING,REFRIGERATING EQUIPMENT, COMMERCIAL HEATINGEQUIPMENT, RESIDENTIAL AIR CONDITIONINGEQUIPMENT, HEAT RECLAIM VENTILATION, AIRCLEANING EQUIPMENT, MARINE TYPE CONTAINERREFRIGERATION UNITS, COMPRESSORS AND VALVES.

    Organization:DAIKIN INDUSTRIES(THAILAND) LTD.

    Scope of Registration:THE DESIGN/DEVELOPMENTAND MANUFACTURE OF AIRCONDITIONERS AND THECOMPONENTS INCLUDINGCOMPRESSORS USED FOR THEM

    All of the Daikin Groups businessfacilities and subsidiaries in Japanare certified under the ISO 14001international standard forenvironment management.