Daikin Australia Pty. Limited Ducted Split Systems 2011.

39
Daikin Australia Pty. Daikin Australia Pty. Limited Limited Ducted Split Systems 2011 Ducted Split Systems 2011

Transcript of Daikin Australia Pty. Limited Ducted Split Systems 2011.

Daikin Australia Pty. LimitedDaikin Australia Pty. Limited

Ducted Split Systems 2011Ducted Split Systems 2011

ContentsContents

Model overviewModel overview Features and benefitsFeatures and benefits ControlsControls Option cardsOption cards The backing of DaikinThe backing of Daikin SummarySummary

Inverter Models Inverter Models

Inverter ModelsInverter Models

RXS50/60KVMARXS50/60KVMA

DC Fan motor

Auto & Manual ESP Adjustment

Compact 300mm highFAN COIL

360mmhigh

360mmhigh

Inverter Models – 3 PhaseInverter Models – 3 Phase

FAN COIL

FAN COIL

360mm high

Huge capacity18 – 25kw’s

Fixed Speed ModelsFixed Speed Models

FAN COIL

Hybrid models – 3 PhaseHybrid models – 3 Phase

FAN COIL

Inverter Technology

Hybrid Inverter Technology

Fixed Speed Technology

Standard on FDYQ50-160 RangeStandard on FDYQ50-160 Range Return air spigots standard Return air spigots standard

(easy installation)(easy installation) Anti corrosion treated coilsAnti corrosion treated coils Self diagnostic systemSelf diagnostic system Indoor units can be dismantled Indoor units can be dismantled

for easier installationfor easier installation High ESP capability High ESP capability High air flow High air flow Big range 2.5kw – 25kwBig range 2.5kw – 25kw Optional remote sensors Optional remote sensors Optional Infra red controllerOptional Infra red controller Optional zone & slave controllerOptional zone & slave controller Compact condensersCompact condensers FDYQ100-160 single & 3phaseFDYQ100-160 single & 3phase 30m long pipe runs with adding 30m long pipe runs with adding

gas on FDYQ100 & abovegas on FDYQ100 & above

FDYQ180 – 250Range

Operating rangeOperating rangeFDYQ100-160

Range

FDYQ180-250 Range

Nav Ease Controller Nav Ease Controller (Standard)(Standard)

• Backlit displayBacklit display• Adjustable off reminder Adjustable off reminder

timertimer• Large buttons and Large buttons and

arrow keys for simple arrow keys for simple operationoperation

• Guide on displayGuide on display• Weekly schedule timerWeekly schedule timer• Multilingual display Multilingual display

availableavailable

30 to 180 min adjustable run timer

Lock out Function

In English not symbols

Zone controllerZone controller• Ability to zone your Ability to zone your

homehome• Ability to program your Ability to program your

system to turn on/off system to turn on/off after a preset number of after a preset number of hourshours

• Up to two on & two off Up to two on & two off programs can be set for programs can be set for each dayeach day

• Ability to link modes & Ability to link modes & set temp’s to each set temp’s to each programprogram

• Alert for cleaning filterAlert for cleaning filter• Available in 4 or 8 zones• 240 volts or 24 volts • Slave controller available (BRCSZC)

Future EnhancementsFuture Enhancements

Ducted FCUDucted FCU

• DC Fan Motor to be introduced across range in September 2011.

• Other enhancements in area of controls, ventilation, filtration, intelligent airflow and efficiency planned.

DC Fan MotorStreamer Plasma Purifier

Option cardsOption cards

KRP4AA53

Remote start/stopInterlocking an outside fanOperation status display and malfunction displayOne adapter can control simultaneously the group of units(Max.16) connected to the remote control wiring line.

By installing this adapter card to the indoor unit, it enables you to have various remote controls.

Daikin wins ‘most satisfied Daikin wins ‘most satisfied customers’customers’

Energy efficiency

Overall satisfaction

After sale service

reliabilityEase of use

Functionality

Noise

Energy efficiency

Functionality

Noise

Energy efficiency

Functionality

Ease of use

Noise

Energy efficiency

Functionality

reliabilityEase of use

Noise

Energy efficiency

Functionality

After sale service

reliabilityEase of use

Noise

Energy efficiency

Functionality Overall satisfaction

After sale service

reliabilityEase of use

Noise

Energy efficiency

Functionality

SummarySummary

Daikin have comprehensive ducted range Daikin have comprehensive ducted range from 2.5kw to 25kwfrom 2.5kw to 25kw

Daikin provide more as standardDaikin provide more as standard Daikin have the infrastructure to provide the Daikin have the infrastructure to provide the

back up and supportback up and support Daikin has the trust of the nationDaikin has the trust of the nation Daikin make it easyDaikin make it easy

Brochures available

THANKYOU...THANKYOU...

Optional AccessoriesOptional Accessories

Hybrid Inverter Technology

Hybrid inverter driven compressors operate in much the same way as an inverter compressor however the software in the system is modified so that the maximum speed of the compressor is capped at the rated capacity.

For example the rated and maximum capacity of the FTYN60D + RYN60D is 6.0kW

When the unit is first switched on, the compressor gradually increases it's speed unit it gets to its rated speed and will operate at this speed, until the room temperature starts getting close to the set temperature. The compressor speed then slows down in order to maintain the room temperature at the desired level. In cooling, if the room temperature starts falling below the set temperature and the compressor is already at it’s lowest speed, the system will cycle the compressor off in order to avoid overcooling the room. The compressor will restart if and when the room temperature rises above the set temperature.

In heating, if the room temperature starts rising above the set temperature and the compressor is already at it’s lowest speed, the system will cycle the compressor off in order to avoid overheating the room. The compressor will restart if and when the room temperature falls below the set temperature

In some systems, the minimum speed of the compressor may also be higher than that of an equivalent inverter system.

A fixed speed system starts up like an inverter system, but operates and shuts down like a non inverter system.

When the system is first switched on, the compressor starts up like an inverter system, gradually increasing its speed until it gets to it’s rated capacity/speed and stays there. In cooling when the temperature in the room falls below the temperature set by the user, like a non inverter system the system cycles the compressor off. The compressors will restart only when the room temperature rises above the set temperature in cooling.

In heating when the temperature in the room rises above the temperature set by the user, like a non inverter system the system cycles the compressor off. The compressors will restart only when the room temperature falls below the set temperature.

Fixed Speed Technology

Inverter Technology

Inverter driven compressors vary their speed to suit the amount of cooling or heating that is required.

By nature they have a maximum and a minimum speed and are normally rated at a speed that typically is lower than the maximum speed. (For example, the FTXS60G + RXS60FB system has a minimum capacity of 1.7kW, a rated capacity of 5.9kW, a maximum capacity of 6.7kW).

When the unit is first switched on, the compressor gradually increases its speed and may operate at a higher than its rated speed in order to heat or cool the room quicker. Once the room temperature gets close to the set temperature, the compressor speed slows down in order to maintain the room temperature at the desired level. In cooling, if the room temperature starts falling below the set temperature and/or the compressor is already at it’s lowest speed, the system will cycle the compressor off in order to avoid overcooling the room. The compressor will restart if and when the room temperature rises above the set temperature.

In heating, if the room temperature starts rising above the set temperature and/or the compressor is already at it’s lowest speed, the system will cycle the compressor off in order to avoid overheating the room. The compressor will restart if and when the room temperature falls below the set temperature

How does it work?How does it work? A Daikin Ducted System provides air conditioned comfort to new and A Daikin Ducted System provides air conditioned comfort to new and

existing homes. existing homes.

The indoor unit is usually located in the ceiling or under the floor with The indoor unit is usually located in the ceiling or under the floor with flexible ductwork distributing conditioned air through vents located flexible ductwork distributing conditioned air through vents located throughout the house, where as, the compressor is installed outside throughout the house, where as, the compressor is installed outside the home. the home.

Daikin ducted systems can be designed to operate in two or more Daikin ducted systems can be designed to operate in two or more zones, which can be heated or cooled at different times.zones, which can be heated or cooled at different times.

This means you can operate your air conditioning system in the living This means you can operate your air conditioning system in the living area during the day and in the bedrooms at night saving you money on area during the day and in the bedrooms at night saving you money on energy costs. energy costs.

KRP4A51 / 53(6) LayoutKRP4A51 / 53(6) Layout

External inputs A & B

16vdc power from indoor unit X18A/X36A

P1/P2 connection X2A

W1/W2 operation display

W3/W4 Error display

Temperature input (resistance)

(RS1) – Control mode selector rotary dial

Temperature setting on/off switch (SS2)

Volt/Non-Volt selector switch (SS1)

Service monitor leds

Survey FindingsSurvey Findings8th of Feb 2010