DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1...

25
DAB Product Brochure RELIABLE, QUALITY, SERVICEABLE, ITALIAN OWNED & DESIGNED

Transcript of DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1...

Page 1: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

DAB Product BrochureRELIABLE, QUALITY, SERVICEABLE, ITALIAN OWNED & DESIGNED

Page 2: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

DAB PumpsWhite International - “Selling DAB in Australia for over 20 years”

Household Domestic Pumps and Pressure Systems Cast Iron Self Priming Jet Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Stainless Steel Self Priming Jet Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Euroinox Stainless Steel Self Priming Horizontal Multistage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Electronic Household Pressure Systems Peripheral Turbine Electronic Pressure System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Self Priming Technopolymer Jet Electronic Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Euroinox Stainless Steel Self Priming Horizontal Multistage Electronic Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cast Iron Self Priming Electronic Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Stainless Steel Self Priming Electronic Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Submersible Household Electronic Pressure System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ACTIVE Variable Frequency Drive Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Variable Speed Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Surface Mounted Pumps Self-Priming Jet/Spear Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Self-Priming Horizontal Multistage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Shallow Well Heavy Duty Self Priming Jet/Spear Point Pumps and Pressure System Pumps Cast Iron Jet Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Twin Stage Jet Assisted Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Cast Iron Jet Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Single Stage Jet Assisted Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Shallow Well Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Deep Well/Borehole Heavy Duty Cast Iron Farm and Irrigation Pressure Systems Deep Well Cast Iron Pressure Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Injector Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Deep Well Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Domestic Centrifugal Pumps KP Peripheral Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Heavy Duty Centrifugal Irrigation and Water Transfer Pumps Small Flow K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Medium Flow K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Twin Stage K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Bore Hole Submersible Pumps4” Bore Hole Submersible Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 S4A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 S4B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 S4C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 S4D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 S4E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 S4F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4” Bore Hole Submersible Pumps Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Circulators for Heating and Air-Conditioning Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Submersible Drainage Pump Solutions NOVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 NOVA SALT MA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 VERTY NOVA 400M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 FEKA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 FEKA BVP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 FEKA Submersible Stainless Steel Vortex Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Submersible Stainless Steel Drainage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Under Hand Basin Pump Station NOVABOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Pressurised Water Storage Tanks PressureWave Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 High Pressure PressureWave 16 Bar Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Challenger Pressure Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 C2B Fibreglass Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 SuperFlow Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 SolarWave Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Useful Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Pipe Friction Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Contents

A FOREVER GROWING COMPANYIn the pump business a brand name has for over 25 years been the hallmark of technology, quality and reliability . The name is DAB . We were founded in 1975 as a pump designer and manufacturer with the specific aim of meeting increasingly higher market requirements, by not only offering products compliant with the highest quality control levels, but also an efficient and versatile service . Starting from our first manufacturing plant, now our head office, we have since grown to employ over 500 people and occupy an area exceeding 60,000m2, with industrial sites housing our R&D and production sections that can keep pace with the world-wide market . Our evolution is proven by our four European subsidiaries that form a network to provide our partners and clients with local support . This organisational endeavour has led us to sell over 1000 different listed models and thousands of satisfied customers who can fully verify DAB’s quality .

EXTENSIVE ORGANISATIONManaging a company of our size is a challenge that we face enthusiastically at DAB as we set forever more ambitious goals . We know we can rely on our immense resources in this field . Our highly qualified staff work in R&D, production, logistics, sales, administrative and customer support departments . All these departments, organised in a rational and thus highly efficient structure, are connected to a Europe-wide computer network . It is directly linked to DAB’s management, responsible for coordinating and supervising this fully integrated system thanks to everyone’s tireless commitment . This is because a great organisation is always founded on the responsibility of its human resources .

CUTTING EDGE TECHNOLOGYOrganisations and technology form the basis of our ongoing endeavour to consolidate our market strength . In times of globalisation, focusing on research and flawless production has become the only feasible way to stay ahead as a benchmark for companies and consumers alike . All departments not only have high tech resources and equipment, but also high quality raw materials, numeric control work centres, latest generation lab instruments fluid-dynamics software and 3-D CAD systems . All systems are efficiently operated by highly skilled workers, our first real resource . This is why technological advancement means “looking ahead” .

Company Overview

A history of business developmentWhite International was founded in 1952 and aquired by the Lonsyd Group of companies in 1976 . The Lonsyd Group is an Australian owned company .

From humble beginnings importing hand tools and distributing direct to end users, White International has rapidly grown into a national importation and distribution company servicing multiple markets utilising quality product from around the globe .

Our focus on premium quality products and customer service have assisted greatly in achieving our current status of being a key supplier to the markets we service .

Our objective is to differentiate against alternate suppliers to industry and to build strategic relationships by continually exceeding our customer’s expectations in everything we do .

White International is committed to providing consistency for our customers with full, on time supply of our products, profitable margins for our customers, and a memorable experience with each transaction . To live with this vision we have invested significantly in people and infrastructure .

We strive to ensure our team and culture possess a “CAN DO” attitiude .

Our head office is based in Sydney with distribution centres in Sydney, Australia and Auckland, New Zealand .

Customer ServiceWe have a dedicated Customer Service team to ensure all your enquiries are handled appropriately .

Sales Engineers/Pump SpecialistsWhite International has a team of qualified sales engineers and pump specialists to provide technical assistance and recommendations for specific applications . Our staff receive ongoing training to ensure that we continue to provide a high level of service to our customers .

Workshop FacilitiesWe have fully qualified and experienced staff on site to repair pumps and tool products under warranty .

After Sales Service & SupportWe have for many years provided our customers with an After Sales Service hotline for comsumers and/or customers to assist them with warranty issues .

Page 3: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

1 2DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-62MP 0 .72 0 .44 4 26 179 45 594 40 528 32 422 28 370 26 179 44 303 60 411

DAB-82MP 0 .85 0 .6 6 29 200 60 792 49 647 39 515 34 449 29 200 58 400 67 460

DAB-102MP 1 .13 0 .75 6 29 200 60 792 49 647 40 528 35 462 29 200 58 400 76 527

DAB-132MP 1 .49 1 .0 8 29 200 82 1083 74 977 63 832 55 726 29 200 58 400 68 470

Household DomesticPressure SystemsCast Iron Self Priming Jet Pumps

DO

MESTIC & HOUSEHO

LD

1 DAB Product Brochure 2013

Cast Iron Self Priming Jet Pumps

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

• Cast iron• Hygienic, no maintenance Pressure Wave tanks• Reliable• Low running cost• Ideal for evaporative air conditioners• Save power • Maintenance free GWS Pressure Tank with stainless steel connection

and FDA approved food grade butyl diaphragm• Durability and strength in extreme conditions• Suitable for dams and creeks with TEFC air gap motors• Dry run resistance• Includes fully adjustable pressure switches and pressure gauge

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

• 2 Year Pump Parts & Labour Warranty• 5 Year Tank Replacement Guarantee

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Reduces pump starts• Protects against heat expansion • Stops water wastage from hot water

ATS 5200.485-2006 License No: 60044 Watermark Level 1 CertificationWater mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres.

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

DAB-102MP/20H

DAB-62MP/8V0

0 0

200 20

100 10

300

0

40

100

20

80

60

120

30

400 40

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JET 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JET 82

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

PkPa

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JET 132

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65 4 3 2

JET 102

0

40

100

20

80

60

120

140

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

Note: Tanks pictured sold separately

Page 4: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

3 4DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Stainless Steel Self Priming Jet Pumps• Fully adjustable pressure switch to reduce pressure fluctuations• Self priming jet pump able to lift water up to 9 metres • Stainless steel pump body for bacteria and corrosion resistance• Brass non-return valve and fittings for strength and durability• Pressure gauge to aid pressure switch adjustments• Replaceable TEFC motor with air gap to stop seal failure water entry• Maintenance free GWS Pressure Tank with stainless steel connection and FDA approved food grade butyl diaphragm

• 2 Year Pump Parts & Labour Warranty • 5 Year Tank Replacement Guarantee• AS/NZS 4020 Approved for Drinking Water

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heaters

DAB-JINOX62MP

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Max. PumpPressure

0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-JINOX62MP 0 .72 0 .44 4 26 179 45 594 40 528 32 422 28 370 26 179 44 303 60 411

DAB-JINOX82MP 0 .85 0 .6 6 29 200 60 792 49 647 39 515 34 449 29 200 58 400 67 460

DAB-JINOX102MP 1 .13 0 .75 6 29 200 60 792 49 647 40 528 35 462 29 200 58 400 76 527

DAB-JINOX112MP 1 .4 1 .0 6 44 303 58 766 48 634 40 528 35 462 44 303 73 503 87 597

DAB-JINOX132MP 1 .49 1 .0 8 29 200 82 1083 74 977 63 832 55 726 29 200 58 400 68 470

Stainless Steel Self Priming Jet Pumps

00

20

10

0

40

100

20

80

60

120

30

40

0

200

100

300

400

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JINOX 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JINOX 82

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm 0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

76

5 4 3 2

JINOX 102

0

40

100

20

80

60

120

140

00 0

200 20

100 10

300

0

40

100

20

80

60

120

140

40

50

60

30

400

500

600

PkPa

Hm

Hft

1 .5 210 .5 2 .5 3 3 .5 4 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

Hs 98

76

5 4 3 2

JINOX 112

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JINOX 132

ATS 5200.485-2006 License No: 60044 Watermark Level 1 Certification Water mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres.

• Handles difficult suction environments• Will tolerate aerated water

Why choose a Jet Pump?0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 5: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

5 6DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Euroinox Stainless Steel Self Priming Horizontal Multistage Pumps

Euroinox Stainless Steel Self Priming Horizontal Multistage Pumps

DAB-EUROINOX30/50MP

• Fully adjustable pressure switch to reduce pressure fluctuations• Stainless steel pump body for bacteria and corrosion resistance• Brass non-return valve and fittings for strength and durability• Pressure gauge to aid pressure switch adjustments• Replaceable TEFC motor with air gap to stop seal failure water entry• Maintenance free GWS Pressure Tank with stainless steel connection and FDA approved food grade butyl diaphragm

• 2 Year Pump Parts & Labour Warranty • 5 Year Tank Replacement Guarantee • AS/NZS 4020 Approved for Drinking Water

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heaters

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Max. PumpPressure

0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-EUROINOX30/30MP 0 .72 0 .44 5 26 179 55 726 52 686 50 660 48 634 29 210 58 400 65 450

DAB-EUROINOX30/50MP 0 .88 0 .55 8 29 200 80 1056 74 977 71 937 68 898 29 200 58 400 60 413

DAB-EUROINOX40/50MP 1 .2 0 .75 8 29 200 80 1056 74 977 71 937 68 898 44 303 73 503 82 565

DAB-EUROINOX40/80MP 1 .48 1 .0 12 44 303 120 1584 96 1267 88 1162 84 1109 44 303 73 503 84 576

DAB-EUROINOX50/50MP* 1 .48 1 .0 8 44 303 80 1056 74 977 71 937 68 898 44 303 73 503 103 706

0

100

200

300

400

500

180

160

140

120

100

80

60

40

20

0

0

4

8

ft

0

00

110

220

330

0

0

0 .5

0 .5

2 .5

2 .5

1 .5

1 .5

3 .5

0 2

2

4

4

6

6

8

8

10

10

12

12

14

0

3 .5

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

1

1

3

3

2

2

15

40

5

30

20

45

10

35

25

50

55

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 0 .2 0 .4 0 .6 0 .8 1

0 10 20 30 40 50 60

Q l/s

Q l/min

EUROINOX 30/30

0

100

200

300

400

500

600

700

200

240

160

120

80

40

0

0

4

8

ft

0

110

220

330

440

0

0

0 2

2

4

4

6

6

8

8

10

10

12

12 14 16

14 16 18 20

0

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

1

1

3 4 5

3 4 5

2

2

40

30

20

10

50

60

70

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 1 2 3 4

0 10 20 30 40 6050 8070

Q l/s

Q l/min

EUROINOX 40/50

EUROINOX 30/50

0

100

200

300

400

500

180

160

140

120

100

80

60

40

20

0

8

12

16ft

0

220

330

440

550

0

0

1

1

5

5

3

3

7

0 4

4

8

8

12

12

16

16

20

20

24

24

28

0

7

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

2

2

6

6

4

4

15

40

5

30

20

45

10

35

25

50

55

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 0 .4 0 .8 1 .2 1 .6 2

0 20 40 60 80 100 120

Q l/s

Q l/min

EUROINOX 40/80

• Quiet Operation• Energy Efficient Motors• High Flow Applications

Why Choose a Multistage Pump?

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

ATS 5200.485-2006 License No: 60044 Watermark Level 1 Certification Water mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres.

EUROINOX 50/50

*Model sold in New Zealand only

Page 6: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

8DAB Product Brochure 2013

DO

MESTIC & HOUSEHO

LD

• Self Priming to 9 metres at sea level• Designed specifically for rainwater

tanks, shallow well, spear and bore holes to a maximum depth of 9 metres

• Ideal for drip irrigation and garden watering

• Designed for domestic and urban household pressure systems

• Electronic pump control with dry run protection and automatic restartWear Rings: Stainless Steel

Mechanical Seal: Carbon / CeramicSeal Disc: Stainless SteelMotor Support: Die-Cast AluminiumMotorshaft: 304 Stainless SteelImpeller: TechnopolymerDiffuser: TechnopolymerJet/Venturi: Technopolymer• 2 Year DAB Pump Warranty• DAB Pumps Designed In Italy• AS/NZS 4020 Approved for Drinking Water

• Peripheral turbine pumps are ideal for small drinking water applications: water tanks, caravans, weekenders, garden hose or 1 and 2 tap applications

• Cast iron pump body with special anti corrosion treatment - Cataphoresis is an electrochemical coating process for metallic surfaces widely used in the

automotive industry owing to its penetration and longlasting life, either as priming coat or finished painting . Cataphoresis treatment is proper where a high protection against weather conditions, alkali and diluted acids is requested• Stainless steel motor shaft• Electronic pump control with dry run protection and automatic restart• Carbon / Ceramic mechanical seal• DAB Pumps Designed In Italy• 2 Year DAB Pump Warranty

ELECTRONIC HouseholdPressure SystemsPeripheral Turbine Electronic Pressure System

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-KPF30-16MPCX 0 .53 0 .37 2 22 150 27 356 23 304 20 264 19 251 22 150 Flow Flow 46 317

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-JETCOM62MPCX 0 .72 0 .44 4 22 150 45 594 40 528 32 422 28 370 22 150 Flow Flow 60 411

DAB-JETCOM82MPCX 0 .85 0 .6 6 22 150 60 792 49 647 39 515 34 449 22 150 Flow Flow 67 460

DAB-JETCOM102MPCX 1 .13 0 .75 6 22 150 60 792 49 647 40 528 35 462 22 150 Flow Flow 76 527

DAB-JETCOM132MPCX* 1 .49 1 .0 8 22 150 82 1083 74 977 63 832 55 726 22 150 Flow Flow 68 470

Self Priming Technopolymer Jet Electronic Pressure Systems

7 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

00

20

10

0

40

20

80

60

10030

0

200

100

300

400

PkPa

Hm

Hft

1 21 .50 .5 Q m3/h

0

0 0 .40 .2 0 .6

2010 30

Q l/s

Q l/min

0 62 4

0 842 6 Q US gpm

Q IMP gpm

KPF 30/16

00

20

10

0

40

100

20

80

60

120

30

40

0

200

100

300

400

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JETCOM 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JETCOM 82

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

76

5 4 3 2

JETCOM 102

0

40

100

20

80

60

120

140

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JETCOM 132

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

*Model sold in New Zealand only

Page 7: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

9 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

10DAB Product Brochure 2013

Euroinox Stainless Steel Self Priming Horizontal Multistage Electronic Pressure Systems• Stainless steel hygenic pumps• Resist naturally occurring water borne bacteria• Unique self priming design makes these pumps

ideal for long suctions and large homes • Electronic pump control with dry run protection and

auto restart• Emit less noise, making them ideal for all

high density urban applications • 2 year Pump Parts & Labour Warranty• DAB Pumps Made in Italy• AS/NZS 4020 Approved for Drinking

Water

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-EUROINOX30/30MPCX 0 .67 0 .49 5 22 150 55 726 52 686 50 660 48 634 22 150 Flow Flow 60 414

DAB-EUROINOX30/50MPCX 0 .88 0 .55 8 22 150 80 1056 74 977 71 937 68 898 22 150 Flow Flow 60 414

DAB-EUROINOX40/50MPCX 1 .2 0 .75 8 22 150 80 1056 74 977 71 937 68 898 22 150 Flow Flow 84 579

DAB-EUROINOX40/80MPCX 1 .48 1 .0 12 22 150 120 1584 96 1267 88 1162 84 1109 22 150 Flow Flow 84 579

DAB-EUROINOX50/50MPCX* 1 .48 1 .0 8 44 303 80 1056 74 977 71 937 68 898 22 150 Flow Flow 103 706

Euroinox Stainless Steel Self Priming Horizontal Multistage Electronic Pressure Systems

COVER YOUR PUMP!Protect your pump from the elements!To extend the working life of your pump, cover your pump from the elements . Refer to DAB Pump warranty terms and conditions which relate to DAB Pumps only . Pump covers are sold separately and available from most water tank manufacturers .

0

100

200

300

400

500

180

160

140

120

100

80

60

40

20

0

0

4

8

ft

0

00

110

220

330

0

0

0 .5

0 .5

2 .5

2 .5

1 .5

1 .5

3 .5

0 2

2

4

4

6

6

8

8

10

10

12

12

14

0

3 .5

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

1

1

3

3

2

2

15

40

5

30

20

45

10

35

25

50

55

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 0 .2 0 .4 0 .6 0 .8 1

0 10 20 30 40 50 60

Q l/s

Q l/min

EUROINOX 30/30

0

100

200

300

400

500

600

700

200

240

160

120

80

40

0

0

4

8

ft

0

110

220

330

440

0

0

0 2

2

4

4

6

6

8

8

10

10

12

12 14 16

14 16 18 20

0

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

1

1

3 4 5

3 4 5

2

2

40

30

20

10

50

60

70

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 0 .4 0 .8 1 .2

0 10 20 30 40 6050 8070

Q l/s

Q l/min

EUROINOX 40/50

EUROINOX 30/50

0

100

200

300

400

500

180

160

140

120

100

80

60

40

20

0

8

12

16ft

0

220

330

440

550

0

0

1

1

5

5

3

3

7

0 4

4

8

8

12

12

16

16

20

20

24

24

28

0

7

Q m3/h

Q US gpm

Q IMP gpm

Q m3/h

2

2

6

6

4

4

15

40

5

30

20

45

10

35

25

50

55

Hm

Hft

m

PkPa

kPaNPSH NPSH

0 0 .4 0 .8 1 .2 1 .6 2

0 20 40 60 80 100 120

Q l/s

Q l/min

EUROINOX 40/80

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

EUROINOX 50/50

*Model sold in New Zealand only

Page 8: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

11 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

12

Cast Iron Self Priming ElectronicPressure Systems

Stainless Steel Self Priming Elecrtonic Pressure Systems

• Quiet running, heavy duty, cast iron corrosion and frost resistant pump body . Self primes for longer suction with TEFC air gap motors

•Suitable for water supply applications with suction wells, water supply and boosting of domestic systems• Electronic pump control with dry run protection and auto restart• 2 Year Pump Parts & Labour Warranty

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-62MPCX 0 .72 0 .44 4 22 150 45 594 40 528 32 422 28 370 22 150 Flow Flow 60 411

DAB-82MPCX 0 .85 0 .6 6 22 150 60 792 49 647 39 515 34 449 22 150 Flow Flow 67 460

DAB-102MPCX 1 .13 0 .75 6 22 150 60 792 49 647 40 528 35 462 22 150 Flow Flow 76 527

DAB-132MPCX 1 .49 1 .0 8 22 150 82 1083 74 977 63 832 55 726 22 150 Flow Flow 68 470

• Stainless steel hygienic jet pumps • High performance • Corrosion resistant • Self priming for long and difficult suction applications• Electronic pump control with dry run protection and

auto restart • Suitable for tanks, dams and creeks

• 2 Year Pump Parts & Labour Warranty• AS/NZS 4020 Approved for Drinking Water

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-JINOX62MPCX 0 .72 0 .44 4 22 150 45 594 40 528 32 422 28 370 22 150 Flow Flow 60 411

DAB-JINOX82MPCX 0 .85 0 .6 6 22 150 60 792 49 647 39 515 34 449 22 150 Flow Flow 67 460

DAB-JINOX102MPCX 1 .13 0 .75 6 22 150 60 792 49 647 40 528 35 462 22 150 Flow Flow 76 527

DAB-JINOX112MPCX 1 .4 1 .0 6 22 150 58 766 48 634 40 528 35 462 22 150 Flow Flow 87 597

DAB-JINOX132MPCX 1 .49 1 .0 8 22 150 82 1083 74 977 63 832 55 726 22 150 Flow Flow 68 470

DAB PUMPSAUSTRALIA &

NEW ZEALAND’S NO.1 PUMP

DAB Product Brochure 2013

00 0

200 20

100 10

300

0

40

100

20

80

60

120

30

400 40

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JET 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JET 82

00 0

20020

100 10

300

0

40

100

20

80

60

120

14040

30

400

PkPa

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JET 132

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65 4 3 2

JET 102

0

40

100

20

80

60

120

140

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 9: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

13 14DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

00

20

10

0

40

100

20

80

60

120

30

40

0

200

100

300

400

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JINOX 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JINOX 82

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

76

5 4 3 2

JINOX 102

0

40

100

20

80

60

120

140

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

00 0

200 20

100 10

300

0

40

100

20

80

60

120

140

40

50

60

30

400

500

600

PkPa

Hm

Hft

1 .5 210 .5 2 .5 3 3 .5 4 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

Hs 98

76

5 4 3 2

JINOX 112

Stainless Steel Self PrimingElectronic Pressure Systems

Submersible Household Pressure System• Ideal pump for rainwater tank installations• Incorporates an electronic automatic restart pump control with dry run protection• Stainless Steel filter to protect pump• Corrosion resistant pump components• Fully automatic operation• Supplied wired and ready to install• Shaft seal with sand protection boot• In-built non-return valve and flow sensor• Built in sand filter to protect pressure switch• 240V single phase motor with in-built auto reset thermal overload• 15m power cable• 2 Year DAB Warranty • DAB Pumps Designed in Italy• AS/NZS4020 Approved for Drinking Water

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft Start Stop

kW kW psi kpa l/m gph psi kpa psi kpa psi kpa

DAB-DIVERTRON1200 1 .2 0 .75 9 33 225 90 1188 33 225 Flow Flow 67 464

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

140

40

30

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

DIVERTRON 1200

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80 90

• Quiet operation• Simple installation• Ideal for dense urban areas• Does not require external pump control

Submersible Pressure Systems

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JINOX 132

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

500

Page 10: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

15 16DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

The Active Driver device is an innovative variable speed pump control, capable of maintaining constant pressure automatically by sensing varying flows . Pressure settings programme at the touch of a button . Some Active controls can interface with one or more Active controls to meet high demands . Active Driver incorporates:• An inverter• A pressure sensor• A flow sensorSome advantages in using Active Driver :• Greater comfort• Substantial energy savings• Greater noise reduction• Reduced dimensions• Eliminates overpressures

• Increased lifespan of the electric pump• Easy installation• Capable of controlling many different

types of electric pumpsActive Driver is equipped with a malfunctions protection system .In the event that a malfunction is verified, it is displayed, depending on the type of error, the electric pump can turn off .• Protection against dry running • Auto Restart Function• Amperometric protection (except MM 1 .1)• Protects against high and low voltage

phase drop protection in 415V models• 2 Year DAB Pump Warranty• Made in Italy

Model / Part No. Description

DAB-ACTIVEDRIVERM/M1 .1PP 240V 1PH in, 240V 1PH out 1 .1 kW1

DAB-ACTIVEDRIVERM/M1 .5PP 240V 1PH in, 240V 1PH out 1 .5 kW1

DAB-ACTIVEDRIVERM/T1 .0 240V 1PH in, 240V 3PH out 1 .0 kW

DAB-ACTIVEDRIVERM/T2 .2 240V 1PH in, 240V 3PH out 2 .2 kW

DAB-ACTIVEDRIVERT/T3 .0 415V 3 PH in, 415V 3PH out 3 .0 kW

DAB-ACTIVEDRIVERT/T5 .5 415V 3 PH in, 415V 3PH out 5 .5 kW

Test performed with a 1 .1 kW pump with pressure set to 3 bar .

Flow (l/min.) Statistic Flow Operation

Direct Connection Consumption

Consumption with Active Driver 1

Power Difference Energy Saved in a Year (8760 hours)

5 20% 1 .295 kW 0 .185 kW 1 .110 1 .945 kW

10 40% 1 .388 kW 0 .555 kW 0 .833 2 .917 kW

20 20% 1 .480 kW 0 .740 kW 0 .740 1 .296 kW

40 9% 1 .573 kW 1 .110 kW 0 .463 365 kW

70 6% 1 .794 kW 1 .570 kW 0 .224 118 kW

100 5% 1 .850 kW 1 .850 kW 0 .000 0

Total Annual Saving kW 6.641 kW

The following protections:ACTIVE DRIVER features a malfunction protection system . Any faults are displayed and, depending on the type of error, the pump may switch off .1 . Dry running protection 2 . Overcurrent protection (except MM 1 .1 which uses motor inbuilt overload)3 . High water temperature protection 4 . Surge / brownout protection

Energy Saving

ACTIVE Variable Frequency Drive Controllers

QUALITYINNOVATIVE

TECHNOLOGY1Fitted with 3 pin plug and female only plug and play lead .

• Suitable for use on small to large homes, irrigation systems, caravan parks, schools, amenity blocks and small unit blocks• Innovative, modern design• Easy and rapid maintenance• All components in contact with drinkable water are completely stainless steel or technopolymer• AS/NZS4020 Approved for Drinking Water• 2 Year DAB Warranty • DAB Pumps Made in Italy

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-JETCOM62MAD 0 .72 0 .44 4 22 150 45 594 40 528 32 422 28 370 22 150 Flow Flow 61 421

DAB-JETCOM82MAD 0 .85 0 .6 6 22 150 60 792 49 647 39 515 34 449 22 150 Flow Flow 67 462

DAB-JETCOM102MAD 1 .13 0 .75 6 22 150 60 792 49 647 40 528 35 462 22 150 Flow Flow 77 531

DAB-EUROINOX40/50MAD 1 .2 0 .75 8 22 150 80 1056 74 977 71 937 68 898 22 150 Flow Flow 84 579

DAB-EUROINOX40/80MAD 1 .48 1 .0 12 22 150 120 1584 96 1267 88 1162 84 1109 22 150 Flow Flow 84 579

Variable Speed Pressure Systems

200

300

400

500

180

160

140

120

100

80

60

0 1 53 7

0 4

4

8

8

12

12

16

16

20

20

24

24

28

0

Q m3/h

Q US gpm

Q IMP gpm

2 64

40

30

20

45

35

25

50

55

Hm

Hft

PkPa

EUROINOX 40/50

00

20

10

0

40

100

20

80

60

120

30

40

0

200

100

300

400

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JETCOM 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2JETCOM 82

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

76

5 4 3 2

JETCOM 102

0

40

100

20

80

60

120

140

EUROINOX 40/80

DAB-ACTIVEDRIVERM/T2 .2

DAB-EUROINOX40/50MAD

*Refer to Page 10 for NPSH Suction Chart

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

0 0 .4 0 .8 1 .2 1 .6 2

0 20 40 60 80 100 120

Q l/s

Q l/min

Page 11: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

17 18DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

17 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Surface Mounted PumpsSelf Priming

DO

MESTIC & HOUSEHO

LD

DAB Jet pumps are renowned for their unique self priming and extraordinary deep suction capability: up to 9 metres at sea level . Available in Cast iron, technopolymer and stainless steel, they are designed to handle abrasive and corrosive water which makes them ideally suited for spear point applications .

• 2 Year Pump Parts & Labour Warranty

Model Material Description

DAB-JINOX62M* Stainless Steel 0 .44 kW, 0 .6 hp, 240V

DAB-JINOX82M* Stainless Steel 0 .6 kW, 0 .8 hp, 240V

DAB-JINOX102M* Stainless Steel 0 .75 kW, 1 .0 hp, 240V

DAB-JINOX112M* Stainless Steel 1 .0 kW, 1 .36 hp, 240V

DAB-JINOX132M* Stainless Steel 1 .0 kW, 1 .36 hp, 240V

DAB-62M Cast iron 0 .44 kW, 0 .6 hp, 240V

DAB-82M Cast iron 0 .6 kW, 0 .8 hp, 240V

DAB-102M Cast iron 0 .75 kW, 1 .0 hp, 240V

DAB-132M Cast iron 1 .0 kW, 1 .36 hp, 240V

DAB-JETCOM62MPP* Technopolymer 0 .44 kW, 0 .6 hp, 240V

DAB-JETCOM82MPP* Technopolymer 0 .60 kW, 0 .8 hp, 240V

DAB-JETCOM102MPP* Technopolymer 0 .75 kW, 1 .0 hp, 240V

DAB-JETCOM132M1 Technopolymer 1 .0 kW, 1 .36 hp, 240V

Note: Jetcom MPP Pumps are fitted with “plug and play” leads (AUS only) .*AS/NZS4020 Approved for Drinking Water1Model available in New Zealand only

DAB-JINOX62M

DAB-62M

DAB-JETCOM62MPP

Model Material Description

DAB-EUROINOX30/30M* Stainless Steel 0 .44 kW, 0 .6 hp, 240V

DAB-EUROINOX30/50M* Stainless Steel 0 .55 kW, 0 .75 hp, 240V

DAB-EUROINOX40/50M* Stainless Steel 0 .8 kW, 1 .1 hp, 240V

DAB-EUROINOX40/80M* Stainless Steel 1 .0 kW, 1 .36 hp, 240V

DAB-EUROINOX50/50M*1 Stainless Steel 1 .0kW, 1 .36 hp, 240V

*AS/NZS4020 Approved for Drinking Water1Model available in New Zealand only

Jet/Spear Point

Ideal for domestic use for water supply and pressurisation, irrigation of gardens and moving of water in general .

• 2 Year Pump Parts & Labour Warranty

Horizontal Multistage

DAB-EUROINOX

Surface Mounted PumpsSelf Priming

100

200

300

400

500

180

160

140

120

100

80

60

40

20

0 1 53 7

0 4

4

8

8

12

12

16

16

20

20

24

24

28

0

Q m3/h

Q US gpm

Q IMP gpm

2 64

15

40

5

30

20

45

10

35

25

50

55

Hm

Hft

PkPa

EUROINOX 40/80EUROINOX 40/50EUROINOX 30/50EUROINOX 30/30

JINOX/JET/JETCOM 82

JINOX/JET/JETCOM 102

JINOX/JET 132

00

20

10

0

40

100

20

80

60

120

30

40

0

200

100

300

400

PkPa

Hm

Hft

21 30 .5 2 .51 .5 Q m3/h

0

0 0 .4 0 .80 .2 0 .6

20 4010 30 50

Q l/s

Q l/min

0 62 84 10

0 84 122 106 Q US gpm

Q IMP gpm

Hs 98

7 6 54

3 2JINOX/JET/JETCOM 62

00 0

200 20

100 10

300

0

40

100

20

80

60

120

14040

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

7 65

43 2

00 0

200 20

100 10

300

40

30

400

50

PkPa

Hm

Hft

21 3 3 .5 40 .5 2 .51 .5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm 0 62 104 8 12 14

0 10 14 1642 6 8 12 Q US gpm

Q IMP gpm

Hs 98

76

5 4 3 2

0

40

100

20

80

60

120

140

00 0

200 20

100 10

300

0

40

100

20

80

60

120

140

40

50

60

30

400

500

600

PkPa

Hm

Hft

1 .5 210 .5 2 .5 3 3 .5 4 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

Hs 98

76

5 4 3 2

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 98

76

54

32

JINOX/JET/JETCOM 82

JINOX/JET/JETCOM 102 JINOX/JET/JETCOM 112

JINOX/JET/JETCOM 132

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

*Refer to Page 10 for NPSH Suction Chart

0 0 .4 0 .8 1 .2 1 .6 2

0 20 40 60 80 100 120

Q l/s

Q l/min

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

1 .2 1 .4

70 80

Page 12: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

19 20DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

19 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

FARM & IRRIGATION

Shallow Well Heavy Duty Self Priming Jet/Spear Point Pumps

DAB pumps offer a large range of pumps suitable for pressure boosting, irrigation, wash down applications . Designed for pumping from tanks, rivers and dams . These pumps are very reliable in the toughest of environments .

• 2 year DAB pumps warranty & 5 year tank guarantee• Fully adjustable Industrial quality IP56 pressure switch and gauge

ATS 5200.485-2006 License No: 60044 Watermark Level 1 CertificationWater mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres. Watermark applies to models FLE-PWSA3, FLE-PWB2V, FLE-PWB8V, FLE-PWB18V, FLE-PWS20H, FLE-PWB35V, FLE-PWB60V, FLE-PWS60H, FLE-PWB80V, FLE-PWB100V.

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

Cast Iron Jet Pumps

Twin Stage Jet Assisted Pumps• Suitable for suction depths up to 8 metres• 2 year DAB warranty

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Maximum Pump

Pressure0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-151M/MP 1 .6 1 .1 8 45 310 79 1043 73 964 59 779 55 726 45 310 70 483 87 597

DAB-251M/MP 2 .2 1 .85 12 46 317 120 1584 107 1413 90 1188 79 1043 46 317 78 538 88 607

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts • Protects against heat expansion • Stops water wastage from

hot water heaters

DAB Pumps offer a large range of pumps suitable for pressure boosting, irrigation, wash down applications . Designed for pumping from tanks, rivers and dams . These pumps are very reliable in the toughest of environments . • 2 year DAB pumps warranty & 5 year tank guarantee• Fully adjustable Industrial quality IP56 pressure switch and gauge

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts • Protects against heat expansion • Stops water wastage from hot water heaters

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

Cast Iron Jet Pumps

• Suitable for suction depths up to 8 metres• 2 year DAB warranty

DAB-300MP/80VNRV not supplied.

DAB-300MP/C130VNRV not supplied.

Model Input Out-put

Taps NominalPressure

Total Suction Head Settings Max. PumpPressure

0 m 0 ft 3 m 10 ft 5 m 16 ft 6 m 20 ft Start Stop

kW kW psi kpa l/m gph l/m gph l/m gph l/m gph psi kpa psi kpa psi kpa

DAB-200M/MP 2 .0 1 .5 18 25 172 185 2422 170 2244 142 1875 125 1650 25 172 43 296 58 401

DAB-300M/MP 2 .7 2 .2 19 28 193 190 2508 170 2244 138 1822 120 1584 28 193 57 393 72 499

0

10

20

30

40400

500

300

200

100

0

50

PkPa

0

0

0

3

30 35 40 45 50

2 .5

25

2

20

1 .5

15

1

10

0 .5

5

0

0

20

5

40

10

60

15

80

20

100

25

120

30

140

35

160

40

180 200

1 32 4 5 6 7 8 109 11 12

Hm

Hft

Q m3/h

Q l/s

Q US gpm

Q l/min

Q IMP gpm

200M

Hs 8 76 5

43

2 1

0

10

20

30

40

400

500

300

200

100

0

50

PkPa

0

0

0

3

30 35 40 45 50

2 .5

25

2

20

1 .5

15

1

10

0 .5

5

0

0

20

5

40

10

60

15

80

20

100

25

120

30

140

35

160

40

180 200

1 32 4 5 6 7 8 109 11 12

Hm

Hft

Q m3/h

Q l/s

Q US gpm

Q l/min

Q IMP gpm

300MHs 8 7 6 5 4 3 2 1

Single Stage Jet Assisted Pumps

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0

0 0 .4 10 .2 0 .80 .6

20 4010 30 50 60

Q l/s

Q l/min

0 62 104 8 12 14 16 18 20

0 10 20 22 2442 6 8 12 14 16 18 Q US gpm

Q IMP gpm

Hs 87 6

5 43 2

1

151M

50

60

500

600

160

180

200

1 .2 1 .4

70 80 90

0

200

100

300

400

PkPa

00

20

10

0

40

100

20

80

60

120

14040

30

Hm

Hft

21 3 4 5 Q m3/h

0 1 2 .50 .5 21 .5

80

Q l/s

Q l/min

0 155 2510 20 30

0 25105 15 20 30 35 40 Q US gpm

Q IMP gpm

Hs 8

76

54 3

21

251M

50

60

500

600

160

180

200

6 7 8 9

6040200 140120100

DAB-151MP

FLE-PWS60H

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

*Tanks pictured sold separately

*Tanks pictured sold separately

Page 13: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

21 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

22DAB Product Brochure 2013

Deep Well / Borehole Heavy Duty Cast Iron Farm and Irrigation Pressure Systems

FARM & IRRIGATION

Deep Well Cast Iron Pressure Systems

Injector Kits

Designed for deep well, offset and boreholes 100mm or larger to depths up to 27 metres . Automatic or manual control . Features include TEFC air gap motors and a selection of injector kits to suit your needs . For our range of pressure tanks refer to page 38-41.

Injector kits also available . E20, E25 & E30 KITS - Include:• Injector body (including nozzle & Venturi)• Foot valve

• Polypropylene tailpipes & pipe fittings• Galvanised pump fittings• Control valve• Blanking plug• Nipple

For our wide range of FDA approved pressure tanks to suit most needs, refer to page 38-41.

Model Description

DAB-DP151M/MP 1 .1 kW, 1 .5 hp, 240V

DAB-DP151MP/60V 1 .1 kW, 1 .5 hp, 240V, 20 Litre tank draw off

DAB-DP151MP/80V 1 .1 kW, 1 .5 hp, 240V, 29 Litre tank draw off

DAB-DP251M/MP 1 .85 kW, 2 .5 hp, 240V

DAB-DP251MP/60V 1 .85 kW, 2 .5 hp, 240V, 20 Litre tank draw off

DAB-DP251MP/80V 1 .85 kW, 2 .5 hp, 240V, 29 Litre tank draw off

DAB-DP151MP/80VInjectors sold seperately

DAB-DP151MP/C100VInjectors sold seperately

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts • Protects against heat expansion • Stops water wastage from hot water heaters

PRE-CHARGEFor PRESSURE SWITCH CONTROLLED PUMPS with a 140kPa (20 psi) differential, the tank pre-charge is set to 20 kPa (3 psi) BELOW the cut in pressure . For pumps controlled by VARIABLE SPEED CONTROLS, pressure controls or pressure switches with a GREATER than 140 kPa (20 psi) differential, the tank pre-charge should be set to 65% of the maximum system pressure .

ATS 5200.485-2006 License No: 60044 Watermark Level 1 CertificationWater mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres. Watermark applies to models FLE-PWSA3, FLE-PWB2V, FLE-PWB8V, FLE-PWB18V, FLE-PWS20H, FLE-PWB35V, FLE-PWB60V, FLE-PWS60H, FLE-PWB80V, FLE-PWB100V.

SHALLOW WELL SELECTION CHART

Model kW

hp

Total Suction Head

m/ft

Delivery Head (metres/feet)

20 66 25 82 30 98 35 115 40 131 45 148 50 164 55 180

Delivery Head (kPa/psi)

196 28 245 36 294 43 343 50 392 57 441 64 489 71 538 78

Flow (litres/min, gallons/min)

JET62JETCOM62JETINOX62

0.440.6

02468

07

132026

4541352820

109864

3226211713

76543

18151296

43321

1075

221

JET82JETCOM82JETINOX82

0.60.8

02468

07

132026

6055433427

1312976

4438332822

108765

3025201613

18151296

76443

43321

107

22

JET102JETCOM102JETINOX102

0.751.0

02468

07

132026

5054433526

1312986

4641363126

109876

3328242017

76544

221815128

54332

13107

322

JETINOX112 1.01.36

02468

07

132026

5852443527

13111086

5047403426

1110976

3732272320

87654

2521181512

65433

1613107

4322

96

21

JET132JETINOX132JETCOM132

1.01.36

02468

07

132026

8279685538

181715128

7161534638

161312108

5143352720

119864

3023169

7542

135

31

JET151 1.11.5

02468

07

132026

6863565045

1514121110

5448433830

1211987

4033272011

97642

2516

64

JET251 1.852.5

02468

07

132026

9686786962

2119171514

7566585043

171513119

5447403021

1210975

342313

753

JET200 1.52.0

02468

07

132026

1411231158869

3127251915

9648604426

211113106

5236

118

JET300 2.23.0

02468

07

132026

169157143128113

3735312825

1351211089072

3027242016

10081644733

221814107

543924

1295

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 14: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

23 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Domestic Centrifugal Pumps

Depths over 27 metres use 1.1/2” x 1.1/4”

Single stage pumps for domestic, civil, industrial and agricultural applications . Ideal for rivers, tanks and dams and water transfer applications . Constructed from high quality Cast Iron for corrosion resistance .

• 2 Year DAB Pump Parts and Labour Warranty

KP Peripheral Pumps

Note: Thick lines on performance curves indicate the maximum and minimum flows. Contact your DAB pump specialist to check suction limitations.

Model Description

DAB-KPF30-16MPP 0 .37 kW, 0 .5 hp, 240V

DAB-KP60-6M 0 .37 kW, 0 .5 hp, 240V

DAB-KP60-6T 0 .37 kW, 0 .5 hp, 415V

DAB-KP60-12M 0 .75 kW, 1 .0 hp, 240V

DAB-KP60-12T 0 .75 kW, 1 .0 hp, 415V

DAB Product Brochure 2013

DO

MESTIC & HOUSEHO

LD

0 .0

20 .0

10 .0

40 .0

30 .0

Flow I/m

0 .0 5 .0 10 .0 15 .0 20 .0 25 .0 30 .0 35 .0 40 .0

50 .0

60 .0

70 .0

80 .0

90 .0

100 .0

Hea

d m

KP60-12

KP60-6

KPF30-16110 .0

DEEP WELL SELECTION CHART

Model kWhp

Injector Kit

Minimum Outlet Pressure

Depth to water (metres/feet)

bar kPa psi 9 30 12 39 15 49 18 59 21 69 24 79 27 89

Flow (litres/min, gallons/min)

DP151 1.11.5

E20 3.03.54.04.55.0

300350400450500

4451586573

5848372513

12.81068.15.52.9

524231185

11.49.26.84.01.1

45352311

9.97.75.12.4

392816

8.66.23.5

DP151 1.11.5

E25 3.03.54.04.55.05.5

300350400450500550

445158657380

47393123159

10.38.66.85.13.32.0

42342618118

9.27.55.74.02.41.1

383022148

8.46.64.83.11.8

DP151 1.11.5

E30 3.03.54.04.55.05.56.0

300350400450500550600

44515865738087

3028241916129

6.66.25.34.23.52.62.0

2825211713107

6.25.54.63.72.92.21.5

262319151186

5.75.14.23.32.41.81.3

DP251 1.852.5

E20 3.03.54.04.55.05.5

300350400450500550

445158657380

726048362311

15.813.210.67.95.12.4

6352422816

13.911.49.26.23.5

4634228

10.17.54.81.8

392714

8.65.93.1

DP251 1.852.5

E25 3.54.04.55.05.56.0

350400450500550600

515865738087

494032231610

10.88.87.05.13.52.2

43352719126

9.57.75.94.22.61.3

393123159

8.66.85.13.32.0

342618115

7.55.74.02.41.1

DP251 1.852.5

E30 4.04.55.05.56.06.57.0

400450500550600650700

586573808794102

2925201613107

6.45.54.43.52.92.21.5

262218141186

5.74.84.03.12.41.81.3

24201613974

5.34.43.52.92.01.50.9

DAB-KP Range

DAB-KPF30-16MPP

24

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 15: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

26DAB Product Brochure 201325 DAB Product Brochure 2011 - 2012

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Twin Stage K SeriesTwin stage pumps for high head applications . Ideal for rivers, tanks and dams . Ideal for irrigation and lawn watering applications . Constructed from high quality Cast iron for corrosion resistance .

• 2 Year DAB Pump Parts and Labour Warranty

Note: Thick lines on performance curves indicate the maximum and minimum flows. Contact your DAB pump specialist to check suction limitations.

Model/Part No Description

DAB-K35-40M 0 .75 kW, 1 .0 hp, 240V, 2 pole

DAB-K45-50M 1 .1 kW, 1 .5 hp, 240V, 2 pole

DAB-K45-50T 1 .1 kW, 1 .5 hp, 415V, 2 pole

DAB-K55-50M 1 .85kW, 2 .5hp, 240V, 2 pole

DAB-K55-50T 1 .85 kW, 2 .5 hp, 415V, 2 pole

DAB-K66-100T 3 .0 kW, 4 .0 hp, 415V, 2 pole

DAB-K90-100T 4 .0 kW, 5 .5 hp, 415V, 2 pole

DAB-K80-300T 7 .5 kW, 10 .0 hp, 415V, 2 pole

0 .0

20 .0

10 .0

40 .0

30 .0

Flow I/m

0 .0 50 .0 100 .0 150 .0 200 .0 250 .0 300 .0 350 .0 400 .0 450 .0

50 .0

60 .0

70 .0

80 .0

90 .0

100 .0

Hea

d m

K35-40

K45-50

K55-50

K66-100

K90-100

K80-300

Heavy Duty Centrifugal Irrigation and Water Transfer Pumps

Single stage pumps for domestic, civil, industrial and agricultural applications . Ideal for rivers, tanks and dams and water transfer applications . Constructed from high quality Cast iron for corrosion resistance .

• 2 Year DAB Pump Parts and Labour Warranty

Small Flow K Series

Note: Thick lines on performance curves indicate the maximum and minimum flows. Contact your DAB pump specialist to check suction limitations.

Model Description

DAB-K20-41M 0 .37 kW, 0 .5 hp, 240V, 2 pole

DAB-K30-70M 0 .75 kW, 1 .0 hp, 240V, 2 pole

DAB-K30-100M 1 .1 kW, 1 .5 hp, 240V, 2 pole

DAB-K36-100M 1 .85 kW, 2 .5 hp, 240V, 2 pole

DAB-K36-200T* 2 .2 kW, 3 hp, 415V, 2 pole

DAB-K12-200M 0 .75 kW, 1 .0 hp, 240V, 2 pole

DAB-K12-200T 0 .75 kW, 1 .0 hp, 415V, 2 pole

DAB-K55-200T 4 .0 kW, 5 .5 hp, 415V, 2 pole

0 .0

20 .0

10 .0

30 .0

Flow I/m

0 .0 50 .0 100 .0 150 .0 200 .0 250 .0 300 .0 350 .0

50 .0

60 .0

Hea

d m

K20-41

K12-200

K30-70

K30-100

K36-100

K55-200

FARM & IRRIGATION

Medium Flow K Series

Model Description

DAB-K14-400M 1 .85 kW, 2 .5 hp, 240V, 2 pole

DAB-K14-400T 1 .85 kW, 2 .5 hp, 415V, 2 pole

DAB-K28-500T 4 .0 kW, 5 .5 hp, 415V, 2 pole

DAB-K50-400T* 7 .5 kW, 10 hp, 415V, 2 pole

DAB-K50-800T* 11 kW, 15 hp, 415V, 2 pole

Single stage pumps for domestic, civil, industrial and agricultural applications . Ideal for rivers, tanks and dams and water transfer applications . Constructed from high quality Cast iron for corrosion resistance .

• 2 Year DAB Pump Parts and Labour Warranty

25 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

*Models available in New Zealand only

*Models available in New Zealand only

K36-200

0 .0

20 .0

10 .0

40 .0

30 .0

Flow I/m

0 .0 200 .0 400 .0 600 .0 800 .0 1000 .0 1200 .0 1400 .0

50 .0

60 .0

70 .0

80 .0

Hea

d m K14-400

K28-500

K14-400

K28-500

Page 16: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

28DAB Product Brochure 201327 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

4” Bore Hole Submersible PumpsDAB Borehole submersible pumps incorporate the latest technology in hydraulic design and materials to reduce running costs, extend pump life and increase serviceability .

• Technopolymer impellers and diffusers for resistance to wear and corrosion• Special unit abrasion wear ring reduces wear due to sand• Cast stainless steel support and valve body for high strength• Single phase motors feature remote control box with manual reset overload• Large range to suit most applications• Floating impeller stack for easier starts in abrasive conditions• Posidrive pump shaft improves impeller life in adverse conditions• Maximum quantity of sand = 120 gm / m3

• 2 Year Pump Parts and Labour Warranty

N. PARTS* MATERIALS

3 Support Precision cast AISI 304 Steel

4 Impeller Technopolymer A with steel shim stainless steel AISI 304 X5CrNi1810 - UNI 6900/71

6 Diffuser Technopolymer A

7 Shaft with Coupling Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

18 Impeller Lock Nut Stainless Steel

39 Cable Sheath Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

42 Filter Stainless Steel

49 Valve Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

54 Motor Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

55 Spacer Technopolymer A

57 Support Technopolymer A

58 Intermediate Bushing Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

69 Pump Lining Stainless Steel AISI 304 X5CrNi1810 - UNI 6900/71

98 Diffuser Body Technopolymer A

117 Upper Head Precision cast AISI 304 Steel

191 Front Adjusting Ring Abrasion-Proof Synthetic Material

192 Rear Adjusting Ring Abrasion-Proof Synthetic Material

270 Upper Shaft Guide Bushing Rubber

271 Intermediate Shaft Guide Bushing

Abrasion-Proof Synthetic Material

* In contact with the liquid

Bore Hole Submersible Pumps

4” Borehole Submersible Pumps

4” B

oreh

ole Su

bm

ersible P

um

ps

Note: Pum

ps should

be op

erated

as close a

s possib

le to the mid

dle of

the perform

ance curve a

nd not outsid

e max

imum

and

minim

um fl

ows.

00 10 20 30

00 20 30 40 200

400

600

800

1000

0

400

800

1200

1600

2000

2400

2600

40 80

120

160

200

240

260

320

00

0 .2

0 .2

0 .4

0 .4

0 .6

0 .6

0 .8

0 .8

11

1 .2

1 .2

1 .4

1 .4

1 .6

1 .6

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4A

15

lpm

00

15

2

10

3

15

4

20

5

25

00

1

0 .1

2

0 .2

3

0 .3

4

0 .4

56

7

S4A-50

S4A-36

S4A-25

S4A-18

S4A-12

S4A-8

P2 stage

ŋ pump

010 20 30 40

010 20 30 40 200

300

100

400

500

600

700

800

900

0

400

800

1200

1600

2000

2400

40 80

120

160

200

240

280

00

0 .4

0 .4

0 .8

0 .8

1 .2

1 .2

1 .6

1 .6

22

2 .4

2 .4

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4B 2

5 lp

m

00

15

21015

3

20

4

3030

56

78

4035

00

1

0 .1

2

0 .2

3

0 .30 .4

0 .5

4

0 .6

56

78

109

S4B-48

S4B-40

S4B-32

S4B-24

S4B-16

S4B-12

S4B-8

S4B-5

P2 stage

ŋ pump

SUBM

ERSIBLE & DRAINAGE 2

DAB PUMPS2 YE

AR

PARTS & LABOUR WA

RR

AN

TY

Page 17: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

29 30DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

4” Borehole Submersible Pumps

4” B

oreh

ole Su

bm

ersible P

um

ps

Note: Pum

ps should

be op

erated

as close a

s possib

le to the mid

dle of

the perform

ance curve a

nd not outsid

e max

imum

and

minim

um fl

ows.

020 30 40 50

020 30 40 50 200

300

100

400

500

600

700

800

1000

900

0

400

800

1200

1600

2000

2400

40 80

120

160

200

240

280

00

0 .8

0 .8

1 .6

1 .6

2 .4

2 .4

3 .2

3 .2

44

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4C 5

0 lp

m

0010

2

2030

4

40

6

6050

810

1214

00

2

0 .2

4

0 .4

6

0 .60 .8

1

8

1 .2

1012

1416

18

S4C-51

S4C-45

S4C-39

S4C-32

S4C-25

S4C-19

S4C-13

S4C-9

S4C-6

P2 stage

ŋ pump

040 50 60 8070

030 40 50 60 70 200

300

100

400

500

600

700

800

900

0

400

800

1200

1600

2000

2400

2800

40 80

120

160

200

240

280

00

11

22

33

44

55

66

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4D

70 lp

m

0010

2030

4

4060

50

812

1620

7080

90100

00

48

0 .4

120 .81 .2

1 .6

1620

24

S4D-45

S4D-38

S4D-34

S4D-29

S4D-25

S4D-21

S4D-17

S4D-13

S4D-8

S4D-6

S4D-4

P2 stage

ŋ pump

4” B

oreh

ole Su

bm

ersible P

um

ps

Note: P

um

ps sh

ould

be o

pera

ted a

s close a

s possib

le to th

e mid

dle o

f th

e perfo

rmance cu

rve and n

ot o

utsid

e max

imum

and m

inim

um

flow

s.

4” Borehole Submersible Pumps

090

100

110

130

120

020 30 40 50 60 200

300

100

400

500

600

700

800

900

0

400

800

1200

1600

2000

2400

2800

40 80

120

160

200

240

280

00

22

44

66

88

1010

1212

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4E 1

35

lpm

0020

4060

8

80120

100

1624

3240

140160

180200

00

816

0 .8

241 .62 .4

3 .2

3240

48

S4E-42

S4E-36

S4E-31

S4E-27

S4E-23

S4E-20

S4E-17

S4E-12

S4E-8

S4E-6

P2 stage

ŋ pump

0

230

250

290

270

020 30 40 50 100

150

50 200

250

300

350

400

450

0

200

400

600

800

1000

1200

1400

20 40 60 80

100

120

140

00

44

88

1212

1616

2020

2424

Q m

3/h

Q m

3/h

Q l/s

Q l/m

in

Q IM

P gpm

Q U

S gpm

HmPWŋ% Hft

PkPa

S4F 2

80 lp

m

0040

80120

16

160240

200

3248

6480

280320

360400

00

1632

1 .6

483 .24 .8

6 .4

6480

96

S4F-18

S4F-13

S4F-10

S4F-7

P2 stage

ŋ pump

Page 18: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

31 32DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

4” BOREHOLE SUBMERSIBLE PUMPS SELECTION CHART

Model P2 Nominal m3/h 0 0.6 1.2 1.5 1.8 2.14 3 4.2 4.8 6 9 11.4 18 24 27

Single Three-phase kW hp l/

min 0 10 20 25 30 40 50 70 80 100 150 190 300 400 500

S4A-8M 0 .25 0 .33

H(m)

44 .4 26 .8 13 .7S4A-12M S4A-12T 0 .37 0 .50 66 .6 40 .2 20 .5S4A-18M S4A-18T 0 .55 0 .75 99 .8 60 .3 30 .8S4A-25M S4A-25T 0 .75 1 .00 138 .7 83 .7 42 .7S4A-36M S4A-36T 1 .10 1 .50 200 .0 120 .6 61 .6S4A-50M S4A-50T 1 .50 2 .00 277 .4 167 .5 85 .5S4B-5M 0 .25 0 .33 30 .0 26 .0 22 .6 19 .0 10 .0S4B-8M S4B-8T 0 .37 0 .50 47 .8 41 .5 36 .2 30 .6 16 .0S4B-12M S4B-12T 0 .55 0 .75 71 .8 62 .3 54 .4 45 .8 24 .0S4B-16M S4B-16T 0 .75 1 .00 95 .7 83 .0 72 .5 61 .0 32 .0S4B-24M S4B-24T 1 .10 1 .50 143 .5 124 .6 108 .7 91 .7 48 .0S4B-32M S4B-32T 1 .50 2 .00 191 .4 166 .0 144 .9 122 .2 64 .0S4B-40M S4B-40T 2 .20 3 .00 239 .2 207 .6 181 .2 152 .8 80 .0S4B-48M S4B-48T 2 .20 3 .00 287 .1 249 .2 217 .4 183 .4 96 .0S4C-6M S4C-6T 0 .37 0 .50 31 .8 30 .7 29 .4 26 .4 22 .7 13 .2S4C-9M S4C-9T 0 .55 0 .75 47 .7 46 .0 44 .0 39 .6 34 .0 19 .8S4C-13M S4C-13T 0 .75 1 .00 68 .9 66 .4 63 .7 57 .2 49 .2 28 .6S4C-19M S4C-19T 1 .10 1 .50 100 .7 97 .0 93 .0 83 .6 71 .8 41 .8S4C-25M S4C-25T 1 .50 2 .00 132 .5 128 .0 122 .5 110 .0 94 .5 55 .0S4C-32M S4C-32T 2 .20 3 .00 169 .6 163 .0 156 .8 140 .8 120 .9 70 .4S4C-39M S4C-39T 2 .20 3 .00 206 .7 200 .0 191 .1 171 .6 147 .4 85 .8

S4C-45T 3 .00 4 .00 238 .5 229 .0 220 .5 198 .0 170 .1 99 .0S4C-51T 3 .00 4 .00 270 .3 261 .0 250 .0 224 .4 192 .8 112 .2

S4D-4M S4D-4T 0 .37 0 .50 23 .0 22 .0 21 .8 18 .0 16 .2 11 .2S4D-6M S4D-6T 0 .55 0 .75 34 .5 33 .0 31 .5 27 .0 24 .3 16 .8S4D-8M S4D-8T 0 .75 1 .00 46 .0 44 .0 42 .0 36 .0 32 .5 22 .4S4D-13M S4D-13T 1 .10 1 .50 47 .7 71 .5 68 .3 59 .0 52 .6 36 .4S4D-17M S4D-17T 1 .50 2 .00 98 .0 93 .5 89 .5 77 .5 6 .88 47 .6S4D-21M S4D-21T 2 .20 3 .00 121 .0 115 .5 110 .0 96 .0 85 .0 8 .5S4D-25M S4D-25T 2 .20 3 .00 144 .0 137 .5 132 .0 114 .5 101 .2 70 .0

S4D-29T 3 .00 4 .00 166 .0 159 .5 152 .0 132 .0 117 .4 81 .2S4D-34T 3 .00 4 .00 196 .0 187 .0 179 .5 155 .0 137 .7 95 .2S4D-38T 4 .00 5 .50 219 .0 209 .0 200 .0 173 .0 153 .9 106 .4S4D-45T 4 .00 5 .50 259 .0 247 .5 237 .0 205 .0 182 .2 127 .0

S4E-6M S4E-6T 0 .75 1 .00 31 .5 30 .0 27 .0 17 .6 7 .7S4E-8M S4E-8T 1 .10 1 .50 42 .0 40 .0 37 .0 23 .4 10 .3S4E-12M S4E-12T 1 .50 2 .00 63 .0 60 .0 55 .0 35 .2 15 .5S4E-17M S4E-17T 2 .20 3 .00 89 .5 86 .0 78 .0 49 .8 21 .9

S4E-20T 3 .00 4 .00 105 .0 101 .5 91 .0 58 .6 25 .7S4E-23T 3 .00 4 .00 120 .5 117 .0 104 .5 67 .4 29 .6S4E-27T 4 .00 5 .50 141 .5 137 .0 122 .5 79 .2 34 .8S4E-31T 4 .00 5 .50 162 .0 156 .0 140 .0 90 .9 39 .9S4E-36T 5 .50 7 .50 188 .0 180 .0 162 .0 105 .5 46 .5S4E-42T 5 .50 7 .50 220 .0 211 .0 189 .0 123 .2 54 .0

S4F-7M S4F-7T 2 .20 3 .00 36 .0 33 .0 24 .0 15 .0 11 .0S4F-10T 3 .00 4 .00 50 .8 47 .0 34 .0 22 .0 16 .0S4F-13T 4 .00 5 .50 66 .0 62 .0 44 .7 28 .0 20 .0S4F-18T 5 .50 7 .50 91 .0 84 .0 61 .2 39 .0 28 .0

Note: Pumps should be operated as close as possible to the middle of the performance curve and not outside maximum and minimum flows.

Circulator for Heating& Air-Conditioning SystemsApplications

Construction Characteristics

Pump for circulating hot water in closed and pressurised or open tank centralised home heating systems . Also suitable for solar systems .

• Single body comprising cast iron (bronze for VS) hydraulic unit and wet rotor motor .• Die-cast aluminium motor casing .• Technopolymer impeller . • Tempered stainless steel driving shaft mounted on graphite brushings lubricated by

the pumped liquid .• Stainless steel protective rotor sleeve, stator sleeve and closing flange .• Ceramic thrust bearing, E .P .D .M . O-rings and brass air outlet cap .• Two-pole asynchronous motor with squirrel cage rotor designed to work at three

speeds, by means of a special selector located on the terminal board, in order to adapt the operation of the circulator to the characteristics of the system (VA Series) .

• Motor self-protected against resistance . No overload protection required .

• 2 Year DAB Pump Parts and Labour Warranty

CAST IRON DOMESTIC CIRCULATOR - for hot water circulation in hot water domestic systems . Also suitable for solar power systems .

Model Max Flow (l/m)

Max Head (m)

Centre Distance P1 Max (W)

Outlet

DAB-VA35-130 50 4 .3 130 mm 56 1 ½” G

DAB-VA55-130 60 5 .4 130 mm 70 1 ½” G

DAB-VA65-130 60 6 .0 130 mm 78 1 ½” G

DAB-VSA65-130-1* 60 6 .0 130 mm 78 1 ½” G

*Model available in New Zealand only

BRONZE DOMESTIC CIRCULATOR - With air separator for heating and air conditioning systems

Model Max Flow (l/m)

Max Head (m)

Centre Distance P1 Max (W)

Outlet

DAB-VS65-150 60 6 150 77 1 ½” G

CIRCULATOR ACCESSORIES

Model Centre Distance

DAB-UNION3/4 Cast Iron (pair) 3/4”

DAB-UNION1 Cast Iron (pair) 1”

DAB-UNION3/4B Brass (pair) 3/4”

DAB-UNION1B Brass (pair) 1”

DO

MESTIC & HOUSEHO

LD

DAB-VS65-150

DAB-VA35-130

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 19: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

34DAB Product Brochure 201333 DAB Product Brochure 2013

SUBM

ERSIBLE & DRAINAGE

Drainage Pumps

Submersible Drainage Pump Solutions

• Reinforced inert plastic body: non-corrosive for long life• Built-in rigid float activated automatic, switch factory set for

reliable operation, eliminates float cable failure• Stainless steel shaft and screws: motor body corrosion

resistant for longer life• Repairable: longer service life• Ball bearings for longer life and quiet operation• Pressure equalised bearing chamber to prevent water entry

to motor via the seal area• Ground rotor shaft, triple lip seals in oil chamber: longer

seal and pump life• 2 Year DAB Pump Parts and Labour Warranty

Model Description

DAB-NOVA180A 0 .20kW, 0 .28hp, 240V, AUTOMATIC, max hd 4 .8m, max flow 80L/m

DAB-NOVA300A 0 .22kW, 0 .3hp, 240V, AUTOMATIC, max hd 6 .8m, max flow 217L/m

DAB-NOVA600A 0 .55kW, 0 .75hp, 240V, AUTOMATIC, max hd 10 .2m, max flow 270L/m

NOVA SALT MA

VERTY NOVA 400M

Model Description

DAB-NOVASALTMA 0 .2kW, 0 .28hp, 240V, AUTOMATIC, max hd 6m, max flow 120L/m

• Specifically designed for use in salt water• Anti-corrosive and rust-proof materials• Motor casing, shaft, screws and nuts made of stainless steel

AISI 316• Excellent cooling of the motor enables it to operate even

when partially submerged• 2 Year DAB Pump Parts and Labour Warranty

Model Description

DAB-VERTYNOVA400M 0 .4kW, 0 .55hp, 240V, AUTOMATIC/MANUAL, max hd 8 .8m, max flow 180L/m

• Specifically designed for use in narrow pits with dimensions down to 20cm x 20cm

• Suitable to pump clear water containing particles up to 5mm diameter

• Anti-corrosive and rust-proof materials• Knob for manual or automatic operation• Excellent cooling of the motor that enables the pump to operate

even when it is partially submerged .• 2 Year DAB Pump Parts and Labour Warranty

DAB-NOVASALTMA

DAB-VERTYNOVA400M

• Reinforced inert plastic body: non-corrosive for long life• Built-in rigid float activated automatic, switch factory set for

reliable operation, eliminates float cable failure• Stainless steel shaft and screws: motor body corrosion resistant

for longer life• Repairable: longer service life• Ball bearings for longer life and quiet operation• Pressure equalised bearing chamber to prevent water entry to

motor via the seal area• Ground rotor shaft, triple lip seals in oil chamber: longer seal

and pump life• 2 Year DAB Pump Parts and Labour Warranty

Vortex Pumps

Submersible Drainage Pump Solutions

Model Description

DAB-FEKA300A 0 .22kW, 0 .3hp, 240V, AUTOMATIC, max hd 5m, max flow 140L/m

Multi-purpose submersible pump for drainage, emptying, pumping water between containers and small irrigation . Suitable to pump dirty water containing soft solids with maximum diameter up to 30 mm .• Anti-corrosive and rust-proof materials • Motor with thermic overload protection• Wear resistant shaft and impeller • Excellent cooling of the motor that enables the pump to operate even when it is partially submerged • Automatic version with start/stop float switch • Supplied with power cable with plug and self-sealing fitting • Double Lip Seals• 2 Year DAB Pump Parts and Labour Warranty

FEKA 300A

• Designed for pumping foul water containing soft solid particles up to 38mm• Anti-corrosion and anti-oxidation materials• Motor with thermal protection against overheating• Wear resistant motor shaft and impeller• Excellent motor cooling to allow pump to run even when only partially

submerged .• Equipped with float switch for automatic starting and stopping of the pump• Equipped with power cable and plug, 3-level union, without check valve• 2 Year DAB Pump Parts and Labour Warranty

FEKA BVP

FEKA 600A

Model Description

DAB-FEKA600A 0 .55kW, 0 .75hp, 240V, AUTOMATIC, max hd 7 .45m, max flow 265L/m

Model Description

DAB-BVP750MA 0 .75kW, 1hp, 240V, AUTOMATIC, max hd 11 .4m, max flow 400L/m

FEKA 300A

0

40

20

60

80

100

PkPa

00

4

2

0

10

30

20

8

10

6

Hm

Hft

84 12 16 20 Q m3/h

0

0 21 3 4 5 6

200100 300

Q l/s

Q l/min

0 20 40 60 80

0 20 40 60 80 Q US gpm

Q IMP gpm

FEKA 600A FEKA BVP

DAB-BVP750MA

DAB-FEKA600A

DAB-FEKA300A

NOVA 300 NOVA 600

NOVASALT VERTYNOVA

0

40

20

60

80

100

PkPa

00

4

2

0

20

10

30

8

10

6

Hm

Hft

42 6 108 12 14 16 Q m3/h

0

0 21 3 4

100 20050 150 250

Q l/s

Q l/min

0 20 40

0 20 40 60 Q US gpm

Q IMP gpm

NOVA 180

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 20: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

35 36DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

• Continuously rated• Designed to pump soft, non-abrasive

solids to 50 mm• Cable Length: 10 metres• Double mechanical seal with

interposed oil chamber (non-toxic oil) • 2 Year DAB Pump Parts and Labour Warranty• Italian Made

STAINLESS STEEL

Model / Part No. Description

DAB-FEKAVS550MA 0 .55 kW, 0 .75 hp, 240V, max head, 7 .4m, max flow 330L/m

DAB-FEKAVS750MA 0 .75 kW, 1 .0 hp, 240V, max head 9 .6m, max flow 400L/m

DAB-FEKAVS1000MA 1 .0 kW, 1 .36 hp, 240V, max head 11 .8m, max flow 450L/m

DAB-FEKAVS1200MA 1 .2 kW, 1 .6 hp, 240V, max head 14m, max flow 533L/m

0

40

20

60

80

100

140

120

PkPa

00

4

2

0

10

30

20

40

8

10

14

12

6

Hm

Hft

84 12 16 20 24 28 32 Q m3/h

0

0 21 3 4 5 6 7 8 9

200 400100 300 500

Q l/s

Q l/min

0 20 40 60 80 100

0 20 40 60 80 100 120 140 Q US gpm

Q IMP gpm

FEKAVS1200

0

40

20

60

80

100

140

120

PkPa

00

4

2

0

10

30

20

40

8

10

14

12

6

Hm

Hft

84 12 16 20 24 28 32 Q m3/h

0

0 21 3 4 5 6 7 8 9

200 400100 300 500

Q l/s

Q l/min

0 20 40 60 80 100

0 20 40 60 80 100 120 140 Q US gpm

Q IMP gpm

FEKAVS1100

0

40

20

60

80

100

140

120

PkPa

00

4

2

0

10

30

20

40

8

10

14

12

6

Hm

Hft

84 12 16 20 24 28 32 Q m3/h

0

0 21 3 4 5 6 7 8 9

200 400100 300 500

Q l/s

Q l/min

0 20 40 60 80 100

0 20 40 60 80 100 120 140 Q US gpm

Q IMP gpm

FEKAVS750

0

40

20

60

80

100

140

120

PkPa

00

4

2

0

10

30

20

40

8

10

14

12

6

Hm

Hft

84 12 16 20 24 28 32 Q m3/h

0

0 21 3 4 5 6 7 8 9

200 400100 300 500

Q l/s

Q l/min

0 20 40 60 80 100

0 20 40 60 80 100 120 140 Q US gpm

Q IMP gpm

FEKAVS550

FEKA Submersible Stainless Steel Vortex Pumps

• Pump completely in stainless steel AISI 304 with thrust ring type impeller for draining clear waste water containing solids of max 10 mm diameter

• AISI 316 stainless steel motor shaft .• Double mechanical heavy duty seal with interposed oil chamber (non-toxic oil)• Excellent cooling of pump motor that enables pump to operate even when it is

partially submerged• Cable Length: 10 metres• Easy and rapid maintenance

• 2 Year DAB Pump Parts and Labour Warranty

STAINLESS STEEL

Model / Part No. Description

DAB-DRENAG1000MA 1 .0 kW, 1 .36 hp, 240V, Flows to 392 l/min, heads to 15 .3 m

DAB-DRENAG1200MA 1 .2 kW, 1 .6 hp, 240V, Flows to 465 l/min, heads to 17 m

0

60

40

20

80

100

PkPa

00

8

6

4

2

0

20

50

10

40

30

12

10

Hm

Hft

4 8 12 16 Q m3/h

0 1 2 3 4 5 6 7

300

Q l/s

Q l/min

0

0 80

80

90

90

40

40

30

30

20

20

10

10

50

50

70

70

60

60

100 110 Q US gpm

Q IMP gpm

DRENAG 1000

14

18

16160

140

120

180

20 24 28

200 25015050 1000 450400350

Submersible Stainless Steel Drainage Pumps

0

60

40

20

80

100

PkPa

00

8

6

4

2

0

20

50

10

40

30

12

10

Hm

Hft

4 8 12 16 Q m3/h

0 1 2 3 4 5 6 7

300

Q l/s

Q l/min

0

0 80

80

90

90

40

40

30

30

20

20

10

10

50

50

70

70

60

60

100 110 Q US gpm

Q IMP gpm

DRENAG 1200

14

18

16160

140

120

180

20 24 28

200 25015050 1000 450400350

DAB PUMPSQUALITY

Uniquely designedSelf-sufficient

CompactEfficient

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

Page 21: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

37 DAB Product Brochure 2013 38DAB Product Brochure 2013

Pressurised Water Storage Tanks

DO

MESTIC & HOUSEHO

LD

High Pressure PressureWave 16 & 24 Bar Tanks• Suitable for many high pressure ap-plications• Super thick steel construction• Patented water connection• Virgin polypropylene liner• Two part polyurethane, epoxy primed paint finish• Leak free O-ring sealed air valve cap• Comprehensive testing• No maintenance

• Single diaphragm design• NSF Standard 61, CE/PED, WRAS approved• All connections are stainless steel un-less stated otherwise . • Tank precharge: 60psi/4 bar• Maximum working pressure: 235psi 16 bar / 362psi 24 bar• Maximum working temperature: 200° F/ 90° C

• Virgin polypropylene liner• Stainless steel water connection • Corrosion resistant for longer life• Controlled action diaphragm• Brass air stem with sealing cap

eliminates air leaks• Condensation reducing design

• Food grade approved high-grade butyl membrane

WSF, WRC, CE FDA/ACS• Max . working temperature: 90°C• Max . working pressure: 150psi/10bar• Tank pre charge: 28psi/1 .9bar

• 5 Year Tank Replacement Guarantee

Model Actual Capacity (litres)

Nominal Draw-off

(litres)

Recommended Max. Working

Pressure

Connection BSP (inches)

Dimensions(mm x mm)

FLE-PWB2V 2 0 .6 10 Bar 1 126 x 209

FLE-PWB8V* 8 3 10 Bar 1 202 x 313

FLE-PWB18V* 18 6 10 Bar 1 279 x 367

FLE-PWS20H* 20 8 10 Bar 1 294 x 447

FLE-PWB24V 24 8 10 Bar 1 290 x 447

FLE-PWB35V* 35 11 10 Bar 1 318 x 555

FLE-PWB60V* 60 22 10 Bar 1 389 x 620

FLE-PWS60H* 60 22 10 Bar 1 424 x 530

FLE-PWB80V 80 29 10 Bar 1 389 x 815

FLE-PWB100V 100 36 10 Bar 1 430 x 804

FLE-PWB150V 150 54 10 Bar 1 530 x 818

Model Actual Capacity (litres)

Nominal Draw-off

(litres)

Recommended Max. Working

Pressure

Connection BSP

(inches)

Dimensions(mm x mm)

FLE-PWB8V-16* 8 3 16 Bar 1 202 x 313

FLE-PWB18V-16* 18 6 16 Bar 1 279 x 367

FLE-PWB80V-16 80 29 16 Bar 1 390 x 815

FLE-PWB8V-25 8 3 24 Bar 1 203 x 313

FLE-PWB24V-25 24 9 24 Bar 1 293 x 447

PressureWave Tanks

ATS 5200.485-2006 License No: 60044 Watermark Level 1.

FLE-PWS20H

FLE-PWB18V

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heatersNO MAINTENANCE - NO WORRIES

* These tanks carry watermark approved to ATS 5200.485 - Lic. No. AGA60044

ATS 5200.485-2006 License No: 60044 Watermark Level 1Water mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres. Watermark applies to models FLE-PWSA3, FLE-PWB2V, FLE-PWB8V, FLE-PWB18V, FLE-PWS20H, FLE-PWB35V, FLE-PWB60V, FLE-PWS60H, FLE-PWB80V, FLE-PWB100V.

FLE-PWB60V

30 Litre Under Basin Automatic Collecting StationNOVABOX

• Automatic collecting and lifting station for domestic wastewater from baths, wash-hand basins, showers and washing machines• 30 litre technopolymer container• Fitted with 240 volt automatic DAB-NOVA300A drainage pump• 5 metre power lead• Discharge check valve• Flow rates from 16l/m to 120l/m, Heads up to 6 meters• Suitable for water temperature up to 50° C in normal operation and up to 90°C for 3 minutes• 2 Year DAB Pump Parts and Labour Warranty

Model Description

DAB-NOVABOX30-300M 30 LITRE NOVA300 PUMP FITTED0 .22kW, 0 .3hp, 240V Automatic

BUILDING SERVICES

0

40

20

60

80

100

PkPa

00

2

1

0

20

10

30

4

5

3

Hm

Hft

21 3 54 6 7 8 Q m3/h

0

0 1 2

50 10025 75 125

Q l/s

Q l/min

0 10 20

0 10 20 30 Q US gpm

Q IMP gpm

6120 40

NOVA BOX

DAB PUMPS• Italian Owned & Designed• Reliable• Quality• Serviceable

2DAB PUMPS2 Y

EA

R PARTS & LABOUR W

AR

RA

NTY

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

AMERICANOWNED &DESIGNED

Page 22: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

39 40DAB Product Brochure 2013 DAB Product Brochure 2013

Challenger Pressure Tanks

Model Actual Capacity (litres)

Nominal Draw-off

(litres)

Recommended Max. Working

Pressure

Connection BSP (inches)

Dimensions(mm x mm)

FLE-C200V 200 73 10 Bar 1-¼ 534 x 1041

FLE-C240V 240 86 10 Bar 1-¼ 534 x 1224

FLE-C310V 310 113 10 Bar 1-¼ 534 x 1511

FLE-C450V 450 165 10 Bar 1-¼ 660 x 1539

• Efficient and cost effective• Patented controlled action - CAD2

diaphragm technology• Threaded nut for easy installation of

pump stand• Welded stainless steel elbow• Appliance quality paint finish over

epoxy primer coat for durability and high luster

• Suitable for drinking water: bacteria resistant

• Condensation reducing design reduces corrosion and increases life

• Adjustable air charge• Diaphragm’s positive lock internal clench ring cannot slip• Stainless steel port diffuser directs water

flow upward and outward while locking the lower diaphragm in place

• Max . working temperature: 90˚C• Max . working pressure:

150psi/10bar• Tank precharge: 20psi/1 .4bar

• 5 Year Tank Warranty

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heaters

C2B Fibreglass Tanks

Model Actual Capacity Pressure

Nominal Draw Off (inches)

Recommended max. working

pressure

Connection BSP (inches)

Dimensions (mm x mm)

FLE-C2B80V 80 29 8 .6 Bar 1 852 x 418

FLE-C2B100V 100 36 8 .6 Bar 1 967 x 418

FLE-C2B130V 130 46 8 .6 Bar 1 1227 x 418

FLE-C2B200V 200 72 8 .6 Bar 1 - 1/4 1098 x 542

FLE-C2B250V 250 90 8 .6 Bar 1 - 1/4 1303 x 542

• Lightweight non-corroding scratch resistant construction• Precision injection moulded copolymer polypropylene domes• Reinforced with durable continuous strand fibreglass• Sealed with epoxy resin • Rugged injection moulded ABS base• Patented CAD-2 controlled action diaphragm, 100% potable quality butyl• Internal clench ring becomes even more positive at higher pressures • Reduces condensation due to ‘air buffer’ design• Pre charged air side 20psi/1 .4Bar • Maximum Temperature up to 50°C• Reinforced base mounted plastic flow-through connection to prevent solids build-up• Maximum working pressure 125psi/8 .6Bar

• 5 Year Tank Warranty

SolarWave Tanks• Ideal for closed loop solar and heating systems• High grade and high temperature butyl diaphragm• High expansion volume factor• Two part polyurethane, epoxy primed paint finish• Leak free o-ring sealed air valve cap• Patented stainless steel connection• Maximum system temperature 130oC• Maximum working pressure: 150psi/ 10 bar• Comprehensive testing•Tank Precharge: 28psi/ 1 .9 bar• 5 Year Tank Replacement Guarantee

• 100% EPDM Diaphragm• Maximum temperature up to 90oC• Maximum working pressure: 362psi/ 25 bar• Tank precharge: 58psi/ 4 bar• High quality polyurethane paint over rugged steel construction• Reinforced tripod legs for easy installation• High pressure durable interchangable tiered construction membrane• 1 Year Membrane Warranty• 2 Year Tank Warranty

Model Actual Capacity (litres)

Nominal Draw-off

(litres)

Recommended Max. Working

Pressure

Connection BSP (inches)

Dimensions(mm x mm)

FLE-SF6025V 60 22 25 Bar 1 810 x 380

FLE-SF10025V 100 36 25 Bar 1 990 x 460

Model Actual Capacity (litres)

Nominal Draw-off

(litres)

Recommended Max. Working

Pressure

Connection BSP

(inches)

Dimensions(mm x mm)

FLE-SWB8V 8 3 10 Bar 3/4” 310 x 202

FLE-SWB18V 18 6 10 Bar 1” 364 x 279

SuperFlow Tanks

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heaters

FLE-SWB8V

1 .Turn the power and water supply off .2 . Turn on a tap to drain the tank .3 . For a pressure switch controlled pump with a differential pres-sure set up to 140 kPa (20 psi), the tank pre-charge should be set to 20 kPa (3 psi) below the cut-in pressure .4 . For a pump controlled by a pressure switch with a higher differential, electronic control or variable speed control, the tank pre-charge should be set to 65% of the maximum system pres-sure .5 . For a pressure tank installed on mains pressure, pre-charge should be set at the mains pressure .6 . For hot water expansion, pre-charge should be set at the mains pressure .7 . Close the tap .8 . Turn the water supply and power on .

Tank Precharge Instructions

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

5GWS

5 YEAR

TANK REPLACEMENT

GUA

RA

NTE

E

ATS 5200.485-2006 License No: 60044 Watermark Level 1Water mark logo only applies to the GWS Energy Saver Tanks. The Watermark does not apply to pumps. Watermark applies to PressureWave Tank sizes 8, 18, 20, 35 & 60 Litres. Watermark applies to models FLE-PWSA3, FLE-PWB2V, FLE-PWB8V, FLE-PWB18V, FLE-PWS20H, FLE-PWB35V, FLE-PWB60V, FLE-PWS60H, FLE-PWB80V, FLE-PWB100V.

Page 23: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

42DAB Product Brochure 201341 DAB Product Brochure 2013

DO

MESTIC & HOUSEHO

LD

GWS Energy Savers

CHALLENGER 10 BAR - DIAPHRAGM TANK - STEEL/BUTYL

C200V 73.4 62.0 33.7 200 1-¼” 1.4 / 20 104.1 x 53.4 Vertical

C240V 86.7 72.7 63.2 240 1-¼” 1.4 / 20 122.4 x 53.4 Vertical

C310V 113.6 95 82.9 310 1-¼” 1.4 / 20 151.1 x 53.4 Vertical

C450V 165 139.3 121.5 450 1-¼” 1.4 / 20 153.9 x 66.0 Vertical

C2 CAD 8.6 BAR - DIAPHRAGM TANK - FIBREGLASS/BUTYL

C2B-80 28.8 23.5 20.4 80 1” 1.4 / 20 85.2 x 41.8 Vertical

C2B-100 36.3 30.7 26.5 100 1” 1.4 / 20 96.7 x 41.8 Vertical

C2B-130 46.6 39 34 130 1” 1.4 / 20 122.7 x 41.8 Vertical

C2B-200 69 59 51.6 200 1-¼” 1.4 / 20 109.8 x 54.2 Vertical

C2B-250 86.5 73.9 64.5 250 1-¼” 1.4 / 20 130.3 x 54.2 Vertical

Model Draw Down (PSI) Capacity (Litres)

Connection Size (BSP)

Precharge (Bar/PSI)

Length x Diameter (cm)

Style

20/40 30/50 40/60

PRESSUREWAVE 10 BAR - Diaphragm Tank - Steel/Butyl

PWB2V 0.73 0.63 0.54 2 1” 1.9 / 28 20.9 x 12.6 Free Mount

PWB8V 2.9 2.5 2.1 8 1” 1.9 / 28 31.7 x 20.2 Free Mount

PWB18V 6.6 5.6 4.8 18 1” 1.9 / 28 36.7 x 27.9 Free Mount

PWS20H 7.3 6.2 5.4 20 1” 1.9 / 28 44.7 x 29.4 Horizontal

PWB24V 8.8 7.4 6.4 24 1” 1.9 / 28 44.7 x 29.0 Vertical

PWB35V 12.8 10.8 9.4 35 1” 1.9 / 28 55.5 x 31.8 Vertical

PWB60V 22.0 18.6 16.1 60 1” 1.9 / 28 62.0 x 38.9 Vertical

PWS60H 22.0 18.6 16.1 60 1” 1.9 / 28 53.0 x 42.4 Horizontal

PWB80V 29.3 24.8 21.5 80 1” 1.9 / 28 81.5 x 38.9 Vertical

PWB100V 36.7 31.0 26.8 100 1” 1.9 / 28 80.4 x 43.0 Vertical

PWB150V 55.0 46.5 40.2 150 1” 1.9 / 28 81.8 x 53.0 Vertical

PRESSUREWAVE 16 BAR - DIAPHRAGM TANK - STEEL/BUTYL

PWB8V 2.9 2.5 3.1 8 1” 4 / 60 31.3 x 20.2 Free Mount

PWB18V 6.6 5.6 4.8 18 1” 4 / 60 36.7 x 27.9 Free Mount

PWB80V 29.3 24.8 20.8 80 1” 4 / 60 81.5 x 39.0 Vertical

Water Pressure Systems

Cottage 10 - 20 l/min Small House 20 - 30 l/minMedium House 30 - 50 l/min Large House 50 - 90 l/min

Requirements

Household Pressure Garden Sprinkler/s Wash Down Drainage Tank Filling Irrigation Sewage

If pumping from a Bore

Bore Diameter . . . . . . . . . . . . . . . . . . . . . Type of Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full Cased . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Is the Casing Slotted Yes No

Standing Water Level (SWL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Draw Down (at rated flow) DDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs

Aquifer Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs (Indicate depth of other) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs

Bore Test (six hours min) Yes No Rated Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l/m

Power Supply 240V 415V If powered by generator state KVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Required to Operate Manual Auto

Application (see diagram)

- Suction Pipe

A) Height from water to pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B) Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Diameter of Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mm Class of Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- Delivery Pipe

C) Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Diameter of Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mm Class of Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D) Height from Pump to Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs E) Demand Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .kpa

Total Output Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .l/m Number of outlets to be used at once: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Flow Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .l/m Delivery Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Total Delivery Head . . . . . . . . . . . . . . . . . . .mtrs

Demand Pressure . . . . . . . . . . . . . . . . . . . . . . . . . .kpa Friction Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Add Demand Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs (if required)

Suction Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mtrs Total Suction Head . . . . . . . . . . . . . . . . . . . . . . .mtrs

Appliances likely to operate at once*

Toilet 9 l/minShower 10 - 15 l/minWater Saving Shower Head 6 - 7 l/minHousehold Tap 10 - 15 l/minDishwasher 15 l/minWashing Machine 10 - 15 l/minGarden Hose 20 l/minLawn Sprinkler 10 - 15 l/min

*Add up the amount of water used by all appliances in your home that are likely to be operating at the same time, i .e . Suppose that you have 3 appliances used at once = Tap, Washing machine and a Shower . Adding up the amount of water used by these 3 is: Tap (10 - 15 l/min) + Washing Machine (10 -15 l/min) + Shower (10 -15 l/min) = TOTAL of 30 - 45 l/min .

Water Source

Dam Bore Spearpoint Tank

Aboveground Inground River Town Mains**

**If mains are different times of the day, require 3 seperate pressures .

How Many Litres A Minute Do You Need?

1. For a pressure switch controlled pump with a differential pressure set up to 140 kPa (20 psi), the tank precharge should be set to 20kPa (3 psi) below the cut-in pressure.2. For a pump controlled by a pressure switch with a higher differential, electronic control or variable speed control, the tank precharge should be set to 65% of the maximum system pressure.3. For a pressure tank installed on mains pressure, precharge should be set at the mains pressure.4. For hot water expansion, precharge should be set equal to the mains pressure

GWS PressureWave Tanks - Energy Saving Device• Extends pump life • Reduces noise • Stores energy • Eliminates pump starts• Protects against heat expansion • Stops water wastage from hot water heatersNO MAINTENANCE - NO WORRIES

AMERICANOWNED &DESIGNED

Page 24: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

43 44DAB Product Brochure 2013 DAB Product Brochure 2013

Note: All pumps must be protected from the elements – cover your pump. Taps calculated at 10 L/min.Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.

Useful InformationPipe Friction Charts

Friction Loss for Poly Pipe - 25mm to 50mm (m/100 metres of pipe)

Flow rate 25mm O.D. 32mm O.D. 40mm O.D. 50mm O.D.

litres/min m3/hour PN 6.3 PN 12.5 PN 6.3 PN 12.5 PN 6.3 PN 12.5 PN 6.3 PN 12.5

12 0 .72 2 .12 2 .97 0 .56 0 .9 .018 0 .32 0 .06

30 1 .8 10 .53 14 .83 2 .78 4 .45 0 .86 1 .58 0 .27 0 .55

48 2 .88 24 .24 34 .17 6 .37 10 .2 1 .97 3 .62 0 .61 1 .25

60 3 .6 9 .46 15 .17 2 .92 5 .38 0 .91 1 .85

72 4 .32 13 .09 21 4 .04 7 .43 1 .25 2 .55

96 5 .76 21 .88 6 .73 12 .41 2 .08 4 .25

120 7 .2 10 .02 18 .5 3 .10 6 .33

180 10 .8 6 .39 13 .07

240 14 .4 10 .70

Friction loss for Rubber Hose (m/100 metres of hose)

Flow rate Friction Loss (m/100 metres of hose)

litres/minute m3/hour 20mm 25mm 32mm 40mm 50mm

12 0 .72 4 .29 1 .14 0 .37 0 .15

30 1 .8 22 .81 5 .88 1 .9 0 .77 0 .2

60 3 .6 21 .11 6 .71 2 .67 0 .7

120 7 .2 24 .37 9 .56 2 .47

180 10 .8 20 .43 5 .21

240 14 .4 35 .22 8 .9

270 16 .2 11 .1

Friction Loss for PVC Pipe - 50mm to 150mm (m/100 metres of pipe)

Flow rate 50mm 80mm 100mm 150mm

litres/minute m3/hour PN 9 PN 12 PN 9 PN 12 PN 9 PN 12 PN 9 PN 12

60 3 .6 0 .42 0 .48

120 7 .2 1 .42 1 .65 0 .23 0 .26

180 10 .8 2 .97 3 .4 0 .46 0 .53

240 14 .4 4 .98 5 .68 0 .77 0 .89 0 .23 0 .26

300 18 7 .43 8 .49 1 .15 1 .32 0 .34 0 .39

360 21 .6 1 .6 1 .83 0 .48 0 .55

420 25 .2 2 .11 2 .42 0 .63 0 .72

480 28 .8 2 .68 3 .07 0 .8 0 .91

540 32 .4 3 .31 3 .8 0 .98 1 .13 0 .19 0 .22

600 36 4 4 .59 1 .19 1 .36 0 .23 0 .27

900 54 2 .47 2 .82 0 .48 0 .55

1200 72 4 .15 4 .75 0 .81 0 .93

1560 93 .6 1 .3 1 .5

2100 126 2 .23 2 .56

Friction Loss for Poly Pipe - 63mm to 110mm (m/100 metres of pipe)

Flow rate 63mm O.D. 75mm O.D. 90mm O.D. 110mm O.D.

litres/minute m3/hour PN 6.3 PN 12.5 PN 6.3 PN 12.5 PN 6.3 PN 12.5 PN 6.3 PN 12.5

60 3 .6 0 .33 0 .61 0 .14 0 .26

120 7 .2 1 .11 2 .07 0 .48 0 .89 0 .20 0 .37

180 10 .8 2 .29 4 .27 0 .99 1 .83 0 .42 0 .76 0 .16 0 .29

240 14 .4 3 .82 7 .15 1 .65 3 .05 0 .69 1 .27 0 .27 0 .49

300 18 5 .70 2 .46 4 .55 1 .03 1 .89 0 .40 0 .72

360 21 .6 7 .92 3 .42 6 .32 1 .43 2 .63 0 .55 1

420 25 .2 4 .51 1 .88 3 .46 0 .72 1 .32

540 32 .4 7 .09 2 .96 5 .45 1 .14 2 .07

600 36 3 .58 6 .59 1 .37 2 .5

900 54 2 .85 5 .2

1200 72 4 .8

Flowin

litres/ min

Friction Loss for Poly Pipe - 20mm to 63mm (m/100 metres of pipe)Medium Density Polythene Pipe

Rural Class B PipePE80/PN8 (mm) PE80/PN10 (mm) PE80/PN12.5 (mm) PE80/PN16 (mm)

3/4” 1” 11/4” 11/2” 2” 20 25 32 40 50 63 20 25 32 40 50 63 20 25 32 40 50 63 20 25 32 40 50 63

10 2 .7 0 .7 0 .2 0 .1 - 3 .9 1 .4 0 .3 0 .1 - - 4 .5 1 .4 0 .4 0 .1 - - 5 .3 1 .8 0 .5 0 .2 0 .1 - 6 .8 2 .2 0 .7 0 .2 0 .1 -

20 9 .8 2 .4 0 .8 0 .3 0 .1 14 .2 4 .0 1 .2 0 .4 0 .1 - 16 .4 5 .1 1 .5 0 .5 0 .2 0 .1 19 .0 6 .4 1 .8 0 .6 0 .2 0 .1 24 .4 8 .0 2 .4 0 .8 0 .3 0 .1

30 20 .8 5 .1 1 .7 0 .7 0 .2 8 .5 2 .6 0 .9 0 .3 0 .1 10 .7 3 .2 1 .0 0 .4 0 .1 13 .6 3 .8 1 .3 0 .4 0 .1 17 .0 5 .2 1 .7 0 .6 0 .2

40 8 .7 2 .9 1 .2 0 .3 4 .5 1 .5 0 .5 0 .2 5 .4 1 .7 0 .6 0 .2 6 .5 2 .2 0 .8 0 .2 8 .8 2 .9 1 .1 0 .3

50 13 .2 4 .5 1 .8 0 .5 6 .8 2 .3 0 .8 0 .3 8 .1 2 .6 0 .9 0 .3 9 .8 3 .4 1 .1 0 .4 13 .3 4 .4 1 .5 0 .5

60 18 .5 6 .2 2 .6 0 .6 9 .5 3 .2 1 .1 0 .4 11 .4 3 .7 1 .3 0 .4 13 .7 4 .8 1 .6 0 .5 18 .0 6 .2 2 .0 0 .7

80 30 .1 10 .6 4 .4 1 .1 5 .5 1 .8 0 .6 6 .3 2 .3 0 .7 8 .1 2 .7 0 .9 10 .5 3 .5 1 .2

100 16 .1 6 .6 1 .6 8 .3 2 .7 0 .9 9 .5 3 .4 1 .1 12 .2 4 .1 1 .3 15 .9 5 .3 1 .7

120 9 .3 2 .3 3 .8 1 .3 4 .8 1 .5 5 .8 1 .9 7 .4 2 .4

140 12 .3 3 .0 5 .1 1 .7 6 .4 2 .0 7 .7 2 .5 9 .8 3 .2

160 3 .9 6 .5 2 .2 8 .1 2 .6 9 .8 3 .2 12 .6 4 .2

180 4 .8 2 .7 3 .3 3 .9 5 .2

200 5 .9 3 .3 4 .0 4 .8 6 .3

220 7 .0 3 .9 4 .7 5 .7 7 .5

240 8 .2 4 .6 5 .6 6 .7 8 .8

250 8 .9 5 .0 6 .0 7 .2 9 .5

Pipe Friction Charts

Optional 6 Year DAB Pump Extended Warranty only applies to models specified, MP/Tank, Active, KPF/Tank, MPCX models. For additional information refer to our DAB website www.dabpumpsaustralia.com.au

Page 25: DAB Product Brochure - Dab Pumps Australiadabpumpsaustralia.com.au/site/dabpump/filesystem... · 1 DAB Product Brochure 2013 DAB Product Brochure 20132 Note: ... 50 P kPa H m H ft

WHITE INTERNATIONAL PTY LTD52-60 Ashford Ave Milperra NSW 2214 PO Box 304 Milperra LPO NSW 2214Phone 02 9783 6000 Fax 02 9783 6001Customer Service Hotline 1300 783 601Email Sales: sales@whiteint .com .auGeneral info: info@whiteint .com .auwww.whiteint.com.au

WHITE INTERNATIONAL NZ LTD15G Kerwyn Avenue,East Tamaki, Auckland 2013, New ZealandPhone 09 579 9777 Fax 09 579 7775Customer Service Hotline 0800 509 506Customer Service Faxline 0800 804 344Email Sales: sales@whiteint .co .nzGeneral info: info@whiteint .co .nzwww.whiteint.co.nz

Available from:

Disclaimer: Every effort has been made to publish the correct details in this brochure. No responsibility will be taken for errors, omissions or changes in product specifications.