DRAWING TITLE
PROJECT DETAILS
DWG NO REVISION
SCALE PAPER SIZE
REVISION HISTORYREV DATE DESCRIPTION DSG CHKDRW
PROJECT NODRAWING
DESIGN
CHECKJ. CUBONG
AS NOTED A1
BISSUE FOR REVIEW
PROPOSED UNITEDSERVICE STATIONWANNEROO ROAD, NEERABU,
WESTERN AUSTRALIA
TBC
J. ABADINAS
J. ABADINAS
A 09-DEC-2019 ISSUE FOR REVIEW JA JCJAB 14-FEB-2020 ISSUE FOR REVIEW JA JCJA
STORMWATER DRAINAGE PLANSCALE 1:200
SITE DATA:
SITE CLASSIFICATION = TO BE CONFIRMEDGROUND WATER TABLE = OVER 2.5m BELOW EXISTING GROUND LEVELSOIL PERMEABILITY = 2 m/day (TO BE CONFIRMED)
GENERAL NOTES:1. DATUM IS LOCAL AND TO BE VERIFIED ON SITE.2. CHECK ALL DIMENSIONS ON SITE. READ ALL ENGINEERING DRAWINGS IN
CONJUNCTION WITH ARCHITECTURAL & SURVEY DRAWINGS. ANY DISCREPANCIESBETWEEN ENGINEERING DRAWINGS AND ARCHITECTURAL DRAWINGS SHALL BECONFIRMED PRIOR TO COMMENCING CONSTRUCTION. DO NOT SCALE FROM THESEDRAWINGS.
3. ALL WORK TO BE IN ACCORDANCE WITH "AS3500-2003 PLUMBING & DRAINAGE", THE"BUILDING CODE OF AUSTRALIA" AND THE LOCAL AUTHORITY'S STANDARDSPECIFICATIONS.
4. LOT CONNECTION PIT (WHEN APPLICABLE) TO LOCAL AUTHORITY SPECIFICATIONS.5. WHERE MANHOLES ARE LOCATED IN THE AREAS SUBJECT TO VEHICULAR LOADING,
STANDARD TRAFFICABLE LIDS ARE TO BE INSTALLED & BASED TO BUILDER'S DETAIL.6. ALL DRAINAGE PIPEWORK SHALL BE PVC CLASS HD STORMWATER, UNLESS WHERE
LOCATED UNDERNEATH ANY STRUCTURES PIPEWORK SHALL BE PVC SEWER CLASS SN8.7. ALIGNMENT OF PIPES SHALL BE AS SHOWN ON THE PLAN & SHALL BE TO THE PIPE OR
MANHOLE CENTRELINE.8. BEFORE CONSTRUCTION COMMENCES, THE CONTRACTOR SHALL:
A. CHECK ON SITE THE LOCATION OF THE EXISTING SERVICES WITH THEAPPROPRIATE AUTHORITY. ENSURE PROPOSED STORMWATER PIPE DOES NOTCLASH WITH ANY EXISTING SERVICES.
B. ARRANGE FOR THE LOCATION AND THE LEVEL OF THE CONNECTION POINT TOEXISTING STORMWATER MANHOLE TO BE VERIFIED BY A SURVEYOR.
C. CONFIRM THAT BOUNDARY PEGS OR OTHER SURVEY REFERENCE POINTS TO BEUSED IN SETTING OUT OF THE PROJECT ARE LOCATED IN THE CORRECTPOSITIONS.
D. ENSURE A PERMIT & REINSTATEMENT SPECIFICATIONS ARE OBTAINED FROM THELOCAL AUTHORITY IF EXCAVATION WILL BE IN A ROAD RESERVE OR RIGHT OFWAY.
E. ENSURE ALL DETAILS HAVE BEEN CHECKED AND THAT NO DISCREPANCIES EXIST.ALL QUERIES AND DISCREPANCIES ARE TO BE RESOLVED PRIOR TOCOMMENCING WORKS.
11. ALL EXCAVATIONS SHALL BE SECURED & MADE SAFE IN ACCORDANCE WITHREQUIREMENTS OF THE OCCUPATIONAL SAFETY & HEALTH ACT OF 1984, THEOCCUPATIONAL SAFETY & HEALTH REGULATION 1996 & OF ANY RELEVANTREGULATORY BODY.
12. PROPERTIES WHICH HAVE BEEN EXCAVATED SHALL BE RETURNED TO AT LEAST ASIMILAR CONDITION TO THAT WHICH EXISTED PRIOR TO CONSTRUCTION.
13. TRENCH BACKFILL SHALL BE CLEAN GRANULAR MATERIAL, COMPACTED TO A LEVELNOT LESS THAN THAT OF THE SURROUNDING UNDISTURBED GROUND, FOR THE FULLDEPTH OF EXCAVATION. BACKFILL UNDER ROADS SHALL BE COMPACTED TO THEREQUIREMENTS OF THE LOCAL AUTHORITY.
14. ALL CONNECTION INTO EXISTING LOCAL AUTHORITY STORMWATER ARE TO BECARRIED OUT BY THE CONTRACTOR TO LOCAL AUTHORITY SPECIFICATIONS.
15. THIS STORM WATER DESIGN IS TO BE READ IN CONJUNCTION WITH THE BUILDER'SARCHITECTURAL DRAWINGS (PARTIALLY REPRODUCED HERE).
16. CLIENT IS TO ENSURE LOCAL AUTHORITY HAVE APPROVED THESE DRAWINGS BEFOREBEING ISSUED FOR PRICING, TENDER & CONSTRUCTION.
LEGEND:
150Ø PIPE
100Ø PIPE FROM BUILDING DOWNSPOUT
TRAFFICABLE STORMWATER TANK WITH GRATE COVER
TRAFFICABLE STORMWATER TANK WITH CONCRETE COVER
NON-TRAFFICABLE STORMWATER TANK WITH CONCRETE COVER
TRAFFICABLE PRECAST SUMP PIT WITH GRATE COVER
FALL DIRECTION
IL+10.00 PIPE INVERT LEVEL
TT+10.00 TOP OF TANK LEVEL
RL+10.00 PAVEMENT LEVEL
HP+10.00 PAVEMENT HIGH POINT
LP+10.00 PAVEMENT LOW POINT
BK+10.00 BOTTOM OF KERB
TK+10.00 TOP OF KERB
EXISTING GROUND LEVEL
D1STORMWATER DRAINAGEPLAN AND DETAILS
EXISTING SLIP ROAD
SIT
E B
OU
ND
AR
Y 6
4.9
5M
SITE BOUNDARY 62.31M
SIT
E B
OU
ND
AR
Y 6
4.9
5M
SITE BOUNDARY 62.31M
4.5m x 1.755m AEROBIC
TREATMENT UNIT TO HYD. ENG'S
DETAILS WITH REQUIRED
CLEARANCES AS INDICATED.
PAINTED LINE
MARKINGS
RUBBER
WHEEL STOPS
TO CAR BAYS
ACROD BAY TO
COMPLY WITH
AS 2890.6
16mm RECESSED
MAT WELL TO
CIVIL DWGS & TO
AS 1428
10m PYLON SIGN AS PER
UNITED STD DWGS.
FOOTING TO ENG'S DWGS
(CONFIRM SAFE DISTANCE
FROM POWERLINES)
2.0M x 2.0m
POTABLE WATER
SYSTEM
2.5M DIA. FIRE
WATER TANK
14m x 0.66m LEACH
DRAIN TO HYD. ENG'S
DETAILS WITH
REQUIRED CLEARANCES
AS INDICATED.
14m x 0.66m LEACH
DRAIN TO HYD. ENG'S
DETAILS WITH REQUIRED
CLEARANCES AS
INDICATED.
SWA
LE 1
ABOVE GROUND STORAGE 1(AREA = 412sqm)
ABOVE GROUND STORAGE 2(AREA = 535sqm)
HEAVY DUTY GRATED DRAIN(DETAILS TO BE CONFIRMED)
ALL SURFACE RUN-OFF UNDER CAR AND TRUCKCANOPY AREAS WILL BE DIRECTED TO OIL AND WATER
SEPARATOR TO HYDRAULIC CONSULTANTS DESIGN
DRA
INW
ELL
2
DRAINWELL 1
DRA
INW
ELL
3
LP + 46.60
LP + 46.60LP + 46.60 LP + 46.60
RL + 46.70
RL + 46.70
RL + 46.70
RL+46.70
RL + 46.70
RL + 46.70
LP + 46.60
HP+46.70
HP+46.55
HP+46.40
HP+46.25
RL+46.40
HP+46.40
HP+46.25
RL+46.20
HP+46.70
RL+46.75RL+46.75
RL+45.75RL+45.75RL+45.75
RL+46.25RL+46.25
RL + 46.70
TYPICAL STORMWATER TANK DETAILSSCALE 1:20
INLET PIPE
PIPE INVERT LEVEL
DEP
TH A
S PE
RPL
AN
THI
S PA
GE
DIAMETER AS PER PLAN THIS PAGE
150
MORTAR FILLETAND BEDDING
TANK BASE TOBUILDER'S DETAILS
100
COMPACTED SUBGRADE TO 90% MDD
OUTLET PIPE
TANK LID TOBUILDER'S DETAILS
PRE-CASTCONCRETE TANKWRAPPED IN"BIDIM A14"GEOFABRIC ALLAROUND ASSHOWN
SOAKAGE HOLEFILLED WITH20-25mm SIZEDAGGREGATE
GROUND LEVEL
SEE
TAN
KSC
HED
ULE