CYBACK_EN

download CYBACK_EN

of 25

description

cybelec

Transcript of CYBACK_EN

  • CYBACK User Guide

    CYBELEC SA Tel. ++ 41 24 447 02 00 RUE DES UTTINS 27 Fax ++ 41 24 447 02 01 CH - 1400 YVERDON-LES-BAINS E-Mail: [email protected] SWITZERLAND V-DOC-CYBACK-EN

  • Information in this document is subject to change without notice, and does not represent a commitment on the part of CYBELEC SA. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of the agreement. It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement.

    Copyright CYBELEC SA. 1991

    All rights reserved.

    Important:

    This notice explains normal and standard programming operations for the numerical control. In view of the fact that numerical controls can be equipped with configurable functions by the press manufacturer for his own specific purposes, please refer to the manufacturer-supplied complementary instructions regarding the programming of these functions.

    Autocad is a registered trade mark of Autodesk Inc..

    CYBELEC is a registred trademark of CYBELEC SA.

    Ethernet is a registered trade mark of Xerox Corporation.

    IBM , PC/AT , PC Network , Token Ring Network are registered trade marks of the International Business Machines Corporation.

    MS-DOS is a registered trade mark of Microsoft Corporation.

    MS-Windows is a registered trade mark of Microsoft Corporation.

    Novell Netware is a registered trade mark of Novell, Incorporated.

    Windows NT is a registered trade mark of Microsoft Corporation.

  • SAFETY AND MAINTENANCE INSTRUCTIONS

    y The operator must be trained for working with the machine on which the numerical control is installed.

    y Improper use of the numerical control can cause heavy damage on equipment and/or injuries to people.

    y Modification of machine parameters can cause important material damage or lead to irregular product quality.

    y The rear panel may only be removed by a qualified technician (danger of electrocution).

    y Do not expose the numerical control to excessive humidity so as to avoid any risk of electrocution and any deterioration of the equipment.

    y Make sure the numerical control is disconnected from the mains power before carrying out any cleaning. Do not use liquids based on alcohol or ammoniac.

    y In case of malfunction of the numerical control, call a technician.

    y Do not expose the numerical control to direct sun rays or any other heat source.

    y Do not place the numerical control in the neighbourhood of magnetic equipment such as transformers, motors or devices which generate interference (welding machines, etc.)

    y Replace fan filters at regular intervals so as to avoid overheating.

    SAFETY AND MAINTENANCE INSTRUCTIONS PAGE I

  • This page has been left blank intentionally.

  • LICENSE AGREEMENT FOR CYBELEC SOFTWARE

    GENERAL COPYRIGHT

    The CYBELEC software is protected by Copyright, and all the copying rights are reserved.

    The CYBELEC software may only be installed and used in authorized equipments (PC or DNC).

    The user manuals are also covered by copyright, and all rights to use and to copy are reserved.

    This document may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced without prior consent, in writing, from CYBELEC.

    SPECIAL DISKETTE COPYRIGHT

    The legal users of this software product are authorized only to copy the contents of the diskette into the memory of the computer to run the program, and to make one backup copy of the original diskette for safety purposes in case of loss of the original program.

    Unauthorized copying, duplicating, selling or otherwise distributing this product is a violation of the law.

    SPECIAL EPROM COPYRIGHT

    The CYBELEC DNC and CNC units in which the original software made by CYBELEC has been replaced by a copy not made by CYBELEC, and without written authorization of CYBELEC, will immediately lose their warranty.

    WARRANTY

    CYBELEC does not warrant that its software products will function properly in every computer and programming environment.

    The limitations of use of a software product and its technical specifications are decided by CYBELEC only; CYBELEC solely is entitled to decide upon conformity and performance of a given software.

    The CYBELEC software does not compensate for incompatibilities in operating system revisions or versions.

    Running the CYBELEC software under various revisions or versions, or switching between different versions or revisions may result in loss or alteration of data.

    LICENSE AGREEMENT PAGE III

  • SOFTWARE UPDATE SERVICE

    Purchase of the CYBELEC software entitles the user, during one year, to delivery of software updates of the "correction" type.

    During the use of a revised or corrected version of the software it may occur that data (program, parameters, etc.) is lost, or that the equipment or its connections need to be modified; these effects are not always foreseeable and do not engage CYBELEC's responsibility.

    TERMINATION

    This agreement shall automatically terminate upon any act of bankruptcy by or against licensee, upon any assignment for the benefit of creditors of the licensee, upon any attachment execution of judgement or process against licensee or its assets that substantially inhibits its ability to do business, or upon dissolution of licensee.

    CYBELEC has the right to terminate this agreement immediately, should the licensee violate the aforementioned conditions.

    Within 30 days of termination of this agreement for any reason, licensee shall at his option, either:

    y return to CYBELEC or authorized dealer all existent copies of such software and related materials, or y furnish to CYBELEC evidence satisfactory that the original and all copies of the software, in whole

    and in any form, have been destroyed.

    LIMITATION OF LIABILITY

    The foregoing warranty is instead of all other warranties, expressed or implied.

    Licensee further agrees that CYBELEC shall not be liable for any lost profits, lost savings, loss of use, or other incidental or consequential damages arising from the use or inability to use the software, or for any claim or demand against licensee by any other party.

    In no event shall CYBELEC be liable for consequential damages, even if CYBELEC has been advised of the possibility of such damages.

    CYBELEC does not warrant that the functions contained in the software will meet the licensee's requirement or that the operation of the software will be totally error free.

    Should the software prove defective, the licensee (and not CYBELEC or an authorized dealer or representative) will assume the entire cost of all necessary service, repair or correction.

    CYBELEC warrants the diskettes, EPROMS or other magnetic support or cassettes on which the programs are supplied to be free of defects in material and workmanship under normal use for a period of 90 days from the date of shipment to the licensee as evidenced by a copy of the packing slip.

    PAGE IV LICENSE AGREEMENT

  • LIMITATION OF REMEDIES

    CYBELEC's entire liability and the licensee's exclusive remedy shall be as follows:

    The replacement of any diskettes or EPROMS or magnetic support media or cassettes not meeting CYBELEC's limited warranty and which materials are returned to CYBELEC or an authorized CYBELEC representative with a copy of the packing slip, or

    If CYBELEC or its representative is unable to deliver replacement diskettes, magnetic support media, EPROM or cassettes which are free of defects in materials or workmanship, the licensee may terminate this agreement under the terms and conditions herein mentioned, and the purchaser's money will be refunded.

    GENERAL

    The licensee acknowledges that he has read this agreement, understands it and agrees to be bound by its terms and conditions.

    The licensee agrees to hold CYBELEC harmless on all liability associated with licensee's breach of this agreement including, but not limited to, all reasonable attorney's fees and court costs, if any.

    This license agreement shall be governed by Swiss law; place of jurisdiction is Lausanne, Switzerland.

    MAINTENANCE

    CYBELEC will provide one year of software maintenance.The extent of maintenance, and response time for furnishing same, shall be at the sole discretion of CYBELEC.Maintenance shall normally include correction of errors in code, correction of errors in supporting documentation, update versions of the covered software which may be released by CYBELEC during the maintenance period.

    In no event shall CYBELEC be obliged to provide technical support in attempting to resolve problems or difficulties resulting from licensee's modification of the licensed software; any such modification by licensee is entirely at licensee's own risk.

    LICENSE AGREEMENT PAGE V

  • This page has been left blank intentionally.

    PAGE VI LICENSE AGREEMENT

  • 14.09.2004 V. 4.0

    CONTENTS

    SAFETY AND MAINTENANCE INSTRUCTIONS............................................................................I

    LICENSE AGREEMENT FOR CYBELEC SOFTWARE ..................................................................III

    INTRODUCTION..............................................................................................................................3

    GETTING STARTED .......................................................................................................................5 Establishing the physical link ...............................................................................................5

    USING CYBACK ..............................................................................................................................7 Creating a link......................................................................................................................7 Data transmission................................................................................................................9

    Backing Up data 9 Restore data 10

    PASSIVE MODE AND WAIT STATE...............................................................................................11 Transfer from the DNC........................................................................................................12

    OPERATOR INTERVENTION DURING DATA TRANSFER...........................................................13 How to abort from the PC keyboard ....................................................................................13 How to abort from the DNC front panel ...............................................................................13

    ANNEXES ........................................................................................................................................15 Connections.........................................................................................................................15

    Loopback connector 15 Connection for RS 232 cable 16 Connection MPL PC 17

    CYBACK_EN.DOC CONTENTS PAGE 1

  • This page has been left blank intentionally.

    PAGE 2 CONTENTS

  • INTRODUCTION

    CYBACK is an ancillary software package running on IBM (or clone) PC.

    It enables you as the user to both BACKUP and RESTORE operational data held on any individual DNC 60, DNC 600, DNC 7000, DNC 70, DNC 30, DNC 50, DNC 20 or DNC 10 in your work environment using RS232/422 cables and connectors.

    Thus you are at liberty to economize on cabling requirements through the use of a central T-bar type switch to change from one destination DNC to another with minimum effort.

    CONNEXIONS RS232

    PC +DOS

    COM port 2

    COM port 1

    RESEAU RS232

    Commutateurcentral

    DNC .... (1)

    DNC ....

    DNC ....

    DNC .... (2)

    At the moment, up to 10 such links are permitted.

    Note that CYBACK can BACKUP & RESTORE data for any version of DNC software. It is not necessary to know precisely what software is installed on a given machine before backing up its data. However, it is absolutely imperative that data backed up for a given DNC is always restored (when the occasion arises) to the very same machine from which it originated, or, alternatively, a machine running exactly the same version of software.

    INTRODUCTION PAGE 3

  • CYBACK facilitates this habitual good practice by identifying links by name strings. But its effective use depends equally upon the operator correctly assigning a link at backup/restore time, either using separate cables, or using the T-bar switch.

    Remember that the software cannot check for the right physical connection, nor identify the transmitting DNC.

    The PC is always the "master", whatever the nature of the link configuration is. The DNC is always the "slave".

    In other words, it is the operator of the PC who commands a transfer from its keyboard. The operator of the DNC is not able to carry out this manipulation, except for the "Wait state" where the transfer can be ordered from the DNC. It is nevertheless possible to cancel a current transfer, either on the PC or on the DNC (see paragraph Passive mode and wait state, page 11).

    PAGE 4 CYBACK USER GUIDE

  • GETTING STARTED

    Copy the CYBACK_WIN.EXE file to the location you wish to have it on your hard disk.

    Eventually make a shortcut, which you will place on your "desk" in order to facilitate the starting of the program.

    ESTABLISHING THE PHYSICAL LINK

    Any RS232 cable for use with CYBACK must be fitted at both ends with SUB D connectors. Male-to-female and female-to-male adaptors are recommended when connections are found to be awkward.

    See annexes for physical connections, page 15.

    One essential item of equipment in your physical link is an invertor. This swaps the "SEND" and "RECEIVE" channels.

    A very frequent cause of communications failure in an RS232 link is the absence of send/receive inversion.

    Please make sure that you include an invertor (visible or otherwise) in your transmission circuit.

    GETTING STARTED PAGE 5

  • This page has been left blank intentionally.

    PAGE 6 CYBACK USER GUIDE

  • USING CYBACK

    CREATING A LINK

    y Click on "Tab" Setup.

    Give a clear and unequivocal name to each link if you have defined several of them.

    If it concerns a fixed installation with several machines, you surely will opt for a switch with several positions on the RS 232 line.

    So you can define a switch position for each machine.

    Also select in which directory the data will be stored.

    The default values on your PC correspond exactly to the same default parameters of your DNC.

    Com port Specifies the communication port of the PC for the link. Default value: 1.

    Baud rate Transmission speed in bits/second. 110, 150, 300, 600, 2400, 4800 or 9600. Default value: 4800.

    USING CYBACK PAGE 7

  • Parity Transmission parity. 0 = None, no parity 1 = odd 2 = even Default value: NONE

    Protocol Allows the selection of different transmission protocols. 0 = DNC Xon (alike DNC). 1 = DNC Xor (alike DNC). 2 = BIP box,

    to transfer via a BIP box (32k bytes memory card) directly connected to the PC RS232 port. The data are compatible with the DNC in BIP mode. Box configuration: refer to the BIP manual.

    3 = Puncher alike the DNC with 2 or 3

    Default value: 0 Xon.

    Selector pos. If several links are in use via a central switch, then they can be labelled. Whole numbers between 0 and 10 permitted. Default value: 1.

    It is very important to change the position of the switch whenever a change from one link to another occurs. Otherwise there is a danger that a restore might be made to a certain DNC which is in fact intended for another one, the destination DNC's data being destroyed in the process.

    Data bits Number of data bits per character transmitted. 7 or 8. Default value: 8.

    Stop bits Number of stop bits per character transmitted. 0 or 1. Default value: 1.

    DNC Nr Optional. DNC number to which the link is physically connected. This can be a serial number or a position number.

    This could be useful if, for example, you have to define several DNCs on the same physical link, and need to distinguish between them, reconnecting the cable from one to another. However, sharing a link in this way is not recommended, since the risk of erroneous RESTORES is increased.

    Make sure that the DNC(s) is(are) programmed with the same configuration.

    PAGE 8 CYBACK USER GUIDE

  • DATA TRANSMISSION

    BACKING UP DATA

    y Click on "Tab" Backup DNC => PC.

    y Verify that the name of the connection (Data link) and the position of the possible selector really correspond to the connected machine.

    y Select what you wish to back up. y Press the "Ctrl" key + click to select several, non-adjacent products. y Press the "Shift" key + click to select several adjacent products. y Make sure that the DNC is in programming mode and that the stop is

    off.

    y Then start the transfer.

    Restore:

    The procedure is identical.

    USING CYBACK PAGE 9

  • RESTORE DATA

    Click on "Tab" Restore PC => DNC.

    The procedure is idential with backing up.

    PAGE 10 CYBACK USER GUIDE

  • PASSIVE MODE AND WAIT STATE

    CYBACK has two distinct modes: ACTIVE and PASSIVE.

    The default value is ACTIVE and automatically used for all the above described trials.

    This means that all data transfers in the form of backups and restores can only be started from the PC keyboard.

    There exists however an alternative PASSIVE mode which allows to command the transfer from the DNC, the PC remains nevertheless the "master".

    Select "Tab" Setup and click on "Wait for DNC ..".

    Wait state mode

    PASSIVE MODE AND WAIT STATE PAGE 11

  • TRANSFER FROM THE DNC

    To execute the transfer from the DNC, please refer to the DNC manual.

    When the transfer actually begins, the display shows RUN.

    There will be a delay of up to 30 seconds before the PC starts to process the request.

    PAGE 12 CYBACK USER GUIDE

  • OPERATOR INTERVENTION DURING DATA TRANSFER

    It is fully possible to abort a RESTORE or BACKUP data transfer, once initiated.

    This can be effected from either the DNC or the PC.

    If the abort is initiated from the PC keyboard, then it is normally necessary to

    press the button on the DNC front panel before restarting the transfer, since the DNC cannot automatically exit its current "transmission" state.

    On the other hand if the DNC initiates the abort when an operator presses the

    button, then the DNC will automatically be ready for another transmission attempt.

    HOW TO ABORT FROM THE PC KEYBOARD

    Press the key.

    You will then see a message in dark red at the foot of the screen confirming that the current BACKUP or RESTORE has been interrupted, and that the operation has not been completed.

    However, before making another attempt to BACKUP/RESTORE it is

    necessary to press on the relevant DNC.

    If this is not done, then the message DNC BUSY will appear soon after the start of the next attempt.

    HOW TO ABORT FROM THE DNC FRONT PANEL

    Press the button. The DNC PC indicator at the top of the DNC screen will disappear.

    Approximately 5 seconds later on the PC screen a message will appear in dark red at the foot of the screen to the effect that the DNC does not reply, that transmission has been interrupted and that the Backup/Restore has not been completed.

    ERROR CONDITIONS AND APPROPRIATE ACTION PAGE 13

  • This page has been left blank intentionally.

    PAGE 14 CYBACK USER GUIDE

  • ANNEXES

    CONNECTIONS

    LOOPBACK CONNECTOR

    25 p DSUB

    2

    3

    4

    5

    6

    20

    TD

    RD

    RTS

    CTS

    DSR

    DTR

    ANNEXES PAGE 15

  • CONNECTION FOR RS 232 CABLE

    DNC CABLE CABLE PC 25PF 25PM 25PF 25PM

    connexion sur capot mtalliqueAnschluss an Metallhlseconnection on the metallic hood

    connexion sur capot mtalliqueAnschluss an Metallhlseconnection on the metallic hood

    max 15 m

    max 15 m

    DNC CABLE CABLE PC 25PF 25PM 9PF 9PM

    PAGE 16 ANNEXES

  • CONNECTION MPL PC

    207

    654321

    76

    54

    32

    1

    20

    BOITIER MPL CABLE CABLE PC

    connexion sur capot mtalliqueAnschluss an Metallhlseconnection on the metallic hood

    max 15 m

    25PF 25PM 25PF 25PM

    ANNEXES PAGE 17

    CYBACK User GuideSafety and Maintenance InstructionsLicense Agreement for CYBELEC SoftwareCONTENTSIntroductionGetting StartedEstablishing the physical link

    Using CYBACKCreating a linkData transmissionBacking Up dataRestore data

    Passive mode and wait stateTransfer from the DNC

    Operator intervention during data transferHow to abort from the PC keyboardHow to abort from the DNC front panel

    ANNEXESConnectionsLoopback connectorConnection for RS 232 cableConnection MPL PC