The Cutting Extinguisher
coldcut™ cobra concept
Safer FirefightingEfficient & Effective FirefightingSaving Environment & Minimizing Collateral Damages
Unique concept
Cuts through virtually any material Suppresses, cools and extinguishes fires from safe position outside of fire roomMobile, high pressure water mist with minimal use of waterThe only method with combined capabilities (penetrating, extinguishing, mobile, minimum of water)
Evolution of the Cutting Extinguisher Concept
Non, unusedor misused
Specialist tool
CuttingExtinguisher
Foam pump introduced
CuttingExtinguisher
Positive Pressure Ventilation (PPV)
IR Camera
First response
Northampton entry
Multiple CuttingExtinguishers
PPV
IR Camera
Industrial Fires
EU Fire FIght II
20092000 20102006 2012
Key performance factors
oxygen heat
fuel
method technology
trained personnel
fireSafe
& efficientintervention
Absence of one, suppresses the result
Key performance - Method
The Cutting Extinguishing Method combines flexible ultra high pressure water mist and structure penetration with use of Thermal Camera, PPV and BA-attackMinimizes the risk for crewBuys time when time is crucialReduces water use and collateral damages to a minimum
Key performance - Technology
Typical Cobra Performance
0
100
200
300
400
500
600
700
800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Tem
pera
ture
CUsing ultra high pressure on
4 MW fire in 20 foot container, penetration at t=12 min
Temperature
Time (min)
Key performance – Trained personnel
Technique is the practical knowledge of the method, tactics is how the technique is used. Thus, training in technique and tactics are essential for crew to achieve top performance
To accomplish the full effect of the cutting extinguishing method, timing is of essence. Thus, all links in chain of decisions must know, and consider, the possibilities of the method, tactics and technique, to make the right decisions at right time
1: Officer evaluates (RISK ASSESSMENT) the situation while the cobra attack initiates…
3: PPV is prepared together with the hose for the oncoming BA attack…
2: The BA team leader leads the cobra attack and evaluate the situation regularly (Thermal Camera-SCAN)…
4: After a total of 3 minutes COBRA ATTACK the BA attack initiates together with PPV into a cool, smokeless and safe environment…
5: The fully evolved villa fire was extinguished 8 minutes later with a total of 180 liters water (no water damage).
Cutting Extinguisher Method Procedures described in a real house fire, SE 2011
1: The Officer in charge at the
incident scene is also
responsible of the work
conditions for the personnel. He
initiates a COBRA ATTACK
almost immediately on arrival at
the scene.
This in line with buying time
through rapidly cooling the fire
gases, break the fire
development and get in control
of the fire
1. Officer Assessment – Cobra Attack
2: The BA team leader evaluates
the situation with THERMAL
CAMERA together with fire
behavior basics. Now he’s in
charge of the COBRA ATTACK,
supported by his two BA crew…
The BA team leader constantly
evaluate the situation to judge
when and how to change the
tactics.
Workflow from a real life villa fire, Sweden 2011
2. Thermal Camera Scan
3: During the ongoing
COBRA ATTACK, the PPV
fan and the hose/s for the
BA attack are prepared.
The incident manager
gets in control of the fire
and may assess
conditions regarding BA
attack or other actions…
3. Preparation PPV and BA-attack
4: After assessing temperature with
Thermal Camera, the BA-group can
initiate a BA-attack after only 3
minutes of COBRA ATTACK. The
temperature is now approx. 100 C,
thus a safer situation regarding
temperature, risk of back draught,
visibility, etc.
At the same time the BA-group
enters, the outside crew break the
windows and turn on the PPV fan to
evacuate the smoke/steam.
4. BA-attack supported by PPV
5: Using the Cutting Extinguisher Concept; Cobra, PPV, Thermal Camera and BA-attack, approx. 8 minutes from arrival, the fully evolved compartment and construction fire is put out in a safe way. Only 180 liters of water was used and no water damage was found.
5. Rest value evaluation
Performance in essence
Combining the technology with trained personnel makes excellent results as the method is fully used
technology method
trained personnel
Safe& efficient
intervention
Critical success factors of Northampton FRS case
Search for alternative methods initiated by unacceptably high number of fatalities in the UKStrong senior level supportAdd technology and method rather than replace leads to acceptance among crewHighly dedicated implementation plan – 6 units first year (rather than buy one for evaluation)High focus on training and methodsCost cutting pressure but rational investmentsNow forefront of UK modern firefighting and Center of Excellence in trainingCobra fitted on 19 out of 23 appliances
www.coldcutsystems.com