Cutler-HammerJanuary 2001Vol. 1,Ref. No. 10487]
Molded Case Circuit Breakers10-225 Amperes 12-21
F-Frame
Product SelectionTable 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed
MaximumContinuousAmpereRating@40°C
100125150175200225
240V AC Maximum, 125V DC (Includes Terminals on Load End Only)
65 kAIC @ 240V AC
Type ED
2-Pole
CatalogNumber
ED2100ED2125ED2150ED2175ED2200ED2225
PriceU.S.S
357.357.357.357.357.357.
3-Pole
CatalogNumber
ED3100ED3125ED3150ED3175ED3200ED3225
PriceU.S.S
885.885.885.885.885.885.
1 00 kAIC @ 240V AC
Type EDH
2-Pole
CatalogNumber
EDH2100EDH2125EDH2150EDH2175EDH2200EDH2225
PriceU.S.S
850.850.850.850.850.850.
3-Pole
CatalogNumber
EDH3100EDH3125EDH3150EDH3175EDH3200EDH3225
PriceU.S.S
1,280.1,280.1,280.1,280.1,280.1,280.
200 kAIC @ 240V AC
Type EDC Current Limiting
2-Pole
CatalogNumber
EDC2100EDC2125EDC2150EDC2175EDC2200EDC2225
PriceU.S.S
1,200.1,200.1,200.1,200.1,200.1,200.
3-Pole
CatalogNumber
EDC3100EDC3125EDC3150EDC3175EDC3200EDC3225
PriceU.S.S
1,655.1,655.1,655.1,655.1,655.1,655.
Note: Instruction Leaflet/FRED Number 29C101
Table 12-34. Type END Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
MaximumContinuous
@40°C
10®152025303540455060708090
100
277V AC Maximum, 125V DC
14 kAIC @ 277V AC
480V AC Maximum, 250V DC
14 kAIC @ 480V AC
Type EHD (Includes Terminals on Load End Only)
1-Pole
CatalogNumber
EHD1010EHD1015®EHD1020®EHD1025EHD1030EHD1035EHD1040EHD1045EHD1050EHD1060EHD1070EHD1080EHD1090EHD1100
PriceU.S.S
123.123.123.123.123.123.123.123.123.123.238.239.238.238.
2-Pole
CatalogNumber
EHD2010EHD2015EHD2020EHD2025EHD2030EHD2035EHD2040EHD2045EHD2050EHD2060EHD2070EHD2080EHD2090EHD2100
PriceU.S.S
387.387.387.387.387.387.387.387.387.387.505.505.505.505.
3-Pole
CatalogNumber
EHD3010EHD3015EHD3020EHD3025EHD3030EHD3035EHD3040EHD3045EHD3050EHD3060EHD3070EHD3080EHD3090EHD3100
PriceU.S.S
498.498.498.498.498.498.498.498.498.498.600.600.600.600.
® Not UL listed. 5 kAIC interrupting rating.® UL listed for SWD applications, see NEC Article 240-83 (d).
Note: Instruction Leaflet/FRED Number 29C101
Discount Symbol CB-2
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog EiT«
Molded Case Circuit BreakersProduct Line Overview
Cutler-HammerJanuary 2001
Vol. 1, Ref. No. [0468]
Product Line DescriptionCutler-Hammer Molded Case CircuitBreakers are designed to provide circuitprotection for low voltage distributionsystems. They are described by NEMAas, "... a device for closing and inter-rupting a circuit between separablecontacts under both normal andabnormal conditions," and furthermoreas, "... a breaker assembled as anintegral unit in a supporting andenclosing housing of insulatingmaterial." The NEC describes them as,"A device designed to open and closea circuit by non-automatic means, andto open the circuit automatically on apredetermined overload of current,without injury to itself when properlyapplied within its rating."
So designed, Cutler-Hammer circuitbreakers protect conductors againstoverloads and conductors and con-nected apparatus, such as motors andmotor starters, against short circuits.
In low voltage distribution systems,there are many varied applicationsof molded case circuit breakers.Cutler-Hammer offers the mostcomprehensive family of moldedcase circuit breakers in the industry.
This family of circuit breakers includes:
Thermal Magnetic Trip BreakersElectronic rms Trip BreakersMolded Case SwitchesMotor Circuit ProtectorsCurrent Limiting BreakersSpecial Application BreakersWorld Breakers
Special CalibrationSpecial non-UL-listed calibrationsare available for certain ambienttemperatures other than 40°C and forfrequencies other than 50/60 Hz or DC.Reduced interrupting ratings will applyfor 400 Hz applications. Maximumthermal calibration is limited to 135Aat 400 Hz.
Suffix H01 400 Hz 20% Adder
50°C Calibration
Add suffix V to Catalog Number forcomplete breaker, listed above, whenordering listed ampere ratings forbreakers to be used in 50°C ambients.
Moisture-Fungus TreatmentAll circuit breaker cases are moldedfrom glass-polyester which does notsupport the growth of fungus. Anyparts which are susceptible to thegrowth of fungus will require specialtreatment.
Suffix J01 Fungus Treated $325. + 20% Adder
Freeze-Tested Circuit BreakersThe circuit breakers may be orderedwith freeze testing. This option usesspecial lubrication and mechanicaloperation is verified at -40°C.
Suffix F01 Freeze Tested 20% Adder
Marine ApplicationsF-Frame circuit breakers can be sup-plied to meet the following marinespecifications:
H U.S. Coast Guard CFR 46 ABS —American Bureau of ShippingIEEE 45
These specifications generally requiremolded case circuit breakers to besupplied with 50°C ambient calibration,special nameplating, and plug-inadapter kits. When plug-in adapter kitsare used, no terminals need be supplied.
Circuit breakers can also be suppliedto meet UL489 Supplement SA(Marine Use) and UL489 SupplementSB (Naval Use).
UL489 Supplement SA applies to vesselsover 65 feet in length. Requirementsinclude 40°C ambient calibration, spe-cial labeling, and no use of aluminumconductors or terminals.
| Suffix H08 "Marine" [ 10% Adder j
UL 489 Supplement SB requires 50°Cambient calibration, vibration testings,special nameplating and no use ofaluminum conductors or terminals.
Suffix H09 "Naval" 10% Adder
Standards and CertificationsMolded case circuit breakers aredesigned to conform with the follow-ing standards:
• Underwriters Laboratories, Inc.,Standard UL489, Molded CaseCircuit Breakers and Circuit BreakerEnclosures
• National Electrical ManufacturersAssociation Standards PublicationNo. AB1-1993, Molded Case CircuitBreakers
• Australian Standard AS 2184,Molded Case Circuit Breakers
• British Standards Institution StandardBS 4752: Part 1, Switchgear andControl Gear Part 1: Circuit Breakers
• Canadian Standards AssociationStandard C22.2 No. 5, ServiceEntrance and Branch Circuit Breakers
• International ElectrotechnicalCommission RecommendationsIEC 157-1, Circuit Breakers
• Japanese T-Mark Standard MoldedCase Circuit Breakers
• South African Bureau of Standards,Standard SABS 156, StandardSpecification for Molded Case CircuitBreakers
• Swiss Electro-Technical AssociationStandard SEV 157-1, Safety Regula-tions for Circuit Breakers
• Union Technique de I'ElectriciteStandard NF C 63-120, Low VoltageSwitchgear and Control Gear CircuitBreaker Requirements
• Verband Deutscher Elektrotechniker(Association of German ElectricalEngineers) Standard VDE 0660, LowVoltage Switchgear and ControlGear, Circuit Breakers
Conformance with these standardssatisfies most local and internationalcodes, assuming user acceptabilityand simplified application.
Molded case circuit breakers equal orexceed Federal Specification Classifi-cation W-C-375b requirements for theparticular class associated with the cir-cuit breaker frame being considered.
Note: For further information, see CircuitBreaker, CD-ROM SA.74A.01.T.E.
EiT« For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
Cutler-HammerJanuary 2001Vol. 1, Ref. No. [0485]
Molded Case Circuit Breakers10 -225 AmperesF-Frame
12-19
ContentsDescription
Product DescriptionTechnical Data
and SpecificationsDimension/WeightsProduct Selection . .
Page
12-19
12-19
12-2012-20
F-Frame Product Descriptionm All F-Frame Circuit Breakers are
HACR rated.B All circuit breakers 10 through
50 amperes are suitable for HID(high intensity discharge) use.
a All F-Frame circuit breakers aresuitable for reverse feed use.
Typical F-Frame Breaker
Technical Data and SpecificationsTable 12-28. UL489 Interrupting Capacity Ratings
CircuitBreakerType
EDEDHEDC
EHD
FOB
FD
HFD
FDC
Numberof Poles
2,32,32,3
12,3
2,3,4
12,3,4
12,3,4
2,3,4
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts AC (50/60 Hz!
240
65100200
18
18
65
100
200
277
—
14
—
25
65
—
480
—
14
14
25
65
100
600
—
—
14
18
25
35
Volts DC ®
125
101010
10
—10
10
—
250 @®
—
10
10
10
22
22
© DC ratings apply to substantially non-inductive circuits.© 2-pole circuit breaker, or two poles of 3-pole circuit breaker.© Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
Table 12-29. IEC157-1 (PI) Interrupting Capacity Ratings (PI)
CircuitBreakerType
EDEDHEDC
FOB
FD
HFD
FDC
Number ofPoles
2,32,32,3
2,3,4
12,3,4
12,3,4
2,3,4
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts AC (50/60 Hz)
220, 240
65100200
18
2565
65100
200
380,415 j 440
—
14
35
65
100
—
14
35
65
100
500
—
14
18
25
35
Volts DC ®
125 | 250®®
101010
—10
10
—
—
10
10
22
22
® DC ratings apply to substantially non-inductive circuits.® 2-pole circuit breaker, or two poles of 3-pole circuit breaker.© Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F;T*N
12-20 Molded Case Circuit Breakers10 -225 Amperes
F-Frame
Cutler-HammerJanuary 2001
Vol. 1,Ref. No. [0486]
Dimensions/WeightsTable 12-30. Dimensions in Inches (mm)Numberof Poles
12
34
Width
1.375(35)2.75 (70)
4.125(105)5.5(140)
Height
6(152)6(152)
6(152)6(152)
Depth
3.375 (86)3.375 (86)
3.375 (86)3.375 (86)
Table 12-31. Approximate Shipping Weight, Lbs. (Kg)Breaker Type
ED, EDH, EDC
EHD, FOB, FD, HFD, FDC
Number of Poles
1
—
2 (.907)
2
3(1.361)
3(1.361)
3
4.5(2.041)
4.5(2.041)
4
—
6(2.721)
Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbersfor circuit breakers or trip units.
Table 12-32. Circuit Breaker Catalog Numbering System
FDC 3 100 L
Circuit BreakerType
EHDFDBFDHFDFDC
Numberof Poles
1 = 1 Pole2 = 2 Poles3 = 3 Poles4 = 4 Poles
Trip Ar
010015020025030035
T
040045050060070080090100110125150175 (FD, HFD, FDC, 2-,200 (FD, HFD, FDC, 2-,225 (FD, HFD, FDC, 2-,
3-, 4-Pole Only)3-, 4-Pole Only)3-, 4-Pole Only)
Suffix
E = 100% Protected (4-Pole only) Neutral PoleEH = 50% Protected (4-Pole only)K = High Magnetic Molded Case SwitchL = Line and Load TerminalsS = Stainless Steel TerminalsV = 50°C CalibrationW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (< 100 Amperes)
Circuit BreakerType
EDEDHEDC
r~Numberof Poles
2 = 2-Pole3 = 3-Pole
EDC 3 200
Suffix
L = Line and Load TerminalsW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (100 Amperes)
EiT»iy For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
12-170Molded Case Circuit BreakersInternal Accessories
Shunt Trip
Cutler-HammerJanuary 2001
Vol. 1, Ref. No. [0636]
Table 12-335. G-Frame Shunt Trip (LH 3-Pole only)
Electrical Ratings
Volts
120240122424
Frequency
50/60 Hz50/60 HzDCDC60 Hz
Amp
1.12.12.85.7-
CatalogNumber
1373D62G011373D62G021373D62G151373D62G161373D62G20
PriceU.S.S
489.489.489.489.489.
SuffixNumber
S1S2S3S4S7
AdderU.S.S
489.489.489.489.489.
Note: G-Frame circuit breakers are factory sealed. UnderwritersLaboratories requires that internal accessories be installed atthe factory.
Internal accessories are UL listed for factory installationunderE7819.
Where local codes and standards permit and UL listing is notrequired, internal accessories can be fiejd installed. Accessoryinstallation should be done before the circuit breaker is mountedand connected.
Note: Instruction Leaflet/FRED Number 15550
Table 12-336. E125 Shunt Trip
Electrical Ratings
Volts
12-60110-240®380 - 600
Frequency Hz
50/60, DC50/60, DC50/60
CatalogNumber
SNT060CPKSNT120CPKSNT480CPK
PriceU.S.S
489.489.489.
® Suitable for use in ground fault applications.Note: Instruction Leaflet/FRED Number 29C152
Table 12-337. F-Frame Shunt Trip
Voltage Rating(AC Frequency = 50/60 Hz)
Factory Mounted
Connection Type and Location
18-Inch (457.2 mm) Pigtail Leads ®
Same Side
SuffixNumber
AdderU.S.S
Rear®
SuffixNumber
AdderU.S.S
Opposite Side
SuffixNumber
AdderU.S.S
Terminal Block
Same Side
SuffixNumber
AdderU.S.S
Field Mounted
Field Installation Kits @
Pigtail Leads
CatalogNumber
PriceU.S.S
Terminal Block
CatalogNumber
PriceU.S.S
Left-Pole Mounting AC/DC Ratings
12 -24V AC or DC48 - 127V AC or 48 - 60V DC ®208 - 380V AC or 1 10 - 127V DC41 5 - 600V AC or 220 - 250V DC
SOISOSSOSS13
489.489.489.489.
S02S06S10S14
489.489.489.489.
S03S07S11S15
489.489.489.489.
S04SOSS12S16
489.489.489.489.
SNT1LP03KSNT1LP08KSNT1LP12KSNT1LP18K
489.489.489.489.
SNT1LT03KSNT1LT08KSNT1LT12KSNT1LT18K
489.489.489.489.
Right- or Neutral-Pole Mounting AC/DC Ratings ©
12 -24V AC or DC48 - 127V AC or 48 - 60V DC ®208 - 380V AC or 1 10 - 127V DC41 5 - 600V AC or 220 - 250V DC
S17S21S25S29
489.489.489.489.
S18S22S26S30
489.489.489.489.
S19S23S27S31
489.489.489.489.
S20S24S28S32
489.489.489.489.
SNT1RP03KSNT1RP08KSNT1RP12KSNT1RP18K
489.489.489.489.
SNT1RT03K®SNT1RT08K®SNT1RT12K®SNT1RT18K®
489.489.489.489.
® Not listed with Underwriters Laboratories, for field installation.® Pigtail wire size: 18 AWG (0.82 mm2).® Standard pigtail lead exit location.® 120V AC marked suitable for ground fault protection devices.® Standard mounting location.® Not for use on 4-pole circuit breakers.Note: Instruction Leaflet/FRED Number 29C140
Table 12-338. J250 Shunt Trip
Electrical Ratings
Volts
12-60110-240®380-600
Frequency Hz
50/60, DC50/60, DC50/60
CatalogNumber
SNT060CPKSNT120CPKSNT480CPK
PriceU.S.S
489.489.489.
® Suitable for use in ground fault applications.Note: Instruction Leaflet/FRED Number 29C152
Discount Symbol CB-2
FiT« For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E