Customer Programming Software RG-1000e (CPS RG-1000e) January 2019 R3.0 User Guide

Transcript of Customer Programming Software RG-1000e (CPS RG-1000e) User...

Page 1: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

Customer Programming Software RG-1000e(CPS RG-1000e)

January 2019R3.0

User Guide

Page 2: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

Table of Contents

CPS RG-1000e User Guide

Table of Contents

Foreword 3

Revision history 4

Introduction 5

Cables compatability chart 6

1. RG-1000e Customer Programming Software (RG-1000e CPS) 7

81.1 Software installation

91.2 Connecting the RG-1000e to PC

111.3 CPS interface and main features

111.3.1 CPS control panels

121.3.2 Operation with configuration files

131.3.3 Gateway panel

1.3.3.1 Network section 14

1.3.3.2 Radio 1&2 section 21

1.3.3.3 Other 39

1.3.3.4 Statistics section 43

1.3.3.5 Monitor section 53

1.3.3.6 Info section 54

2. Radio settings 55

552.1 MOTOTRBO settings

602.2 non-Mototrbo settings

602.2.1 CDM\PRO

622.2.2 XPR8300\XPR8400\XIRR8200

632.2.3 MTM5***

3. SmartPTT Radioserver settings 71

713.1 Interaction with Mototrbo remote control stations in direct communication modeor with the use of single repeater (IP Site Connect network)

773.2 Interaction with Mototrbo remote control stations in the Capacity Plus Legacymode

783.3 Interaction with Mototrbo remote control stations in the NAI Capacity Plus andNAI Linked Capacity Plus hybrid modes

Page 3: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

Table of Contents

CPS RG-1000e User Guide

813.4 Interaction with non-Mototrbo remote control stations (remote I\O controlstaition), for SmartPTT 9.3 and above

843.5 Interaction with non-Mototrbo remote control stations (using SmartPTT CallEmulation), for SmartPTT 9.2 and earlier

4. Radio 1(2) port configuration samples 90

914.1 Mototrbo, Radio 1(2) port settings

954.2 APX\XTL, Radio 1(2) port setting, SmartPTT 9.3 and above

1004.3 APX\XTL, Radio 1(2) port settings, SmartPTT 9.2 and earlier

1054.4 MTM, Radio 1(2) port settings, SmartPTT 9.3 or later

1094.5 MTM, Radio 1(2) port settings, SmartPTT 9.2 or earlier

1134.6 SLR5500\XPR8300\XPR8400\XIRR8200, Radio 1(2) port settings, SmartPTT9.3 or later

1174.7 SLR5500\XPR8300\XPR8400\XIRR8200, Radio 1(2) port settings, SmartPTT9.2 or earlier

Appendix I RG-1000e driver installation 121

Page 4: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

3Foreword

CPS RG-1000e User Guide

Foreword

Disclaimer

The information in this document is carefully examined, and is believed to be entirely reliable. However, no

responsibility is assumed for inaccuracies.

Furthermore, Elcomplus reserves the right to make changes to any products herein to improve readability,

function, or design.

Elcomplus does not assume any liability arising out of the applications or use of any product; nor does it cover

any license under its patent rights nor the rights of others.

Trademarks

MOTOROLA SOLUTIONS, the Stylized M logo, MOTOTRBO are registered in the US Patent & Trademark Office.

SmartPTT and RG-1000e are the property of Elcomplus. All other product or service names are the property of

their respective owners.

Page 5: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

4Revision history

CPS RG-1000e User Guide

Revision history

This table describes the changes to the RG-1000e Customer Programming Software (RG-1000e CPS) user guide.

Date Version Remarks

May, 2017 CPS RG-1000e, R1.0 Initial release.

July, 2017 CPS RG-1000e, R1.1 Updated GUI.

October, 2017 CPS RG-1000e, R2.0 Updated GUI. New features are added.

March, 2018 CPS RG-1000e, R2.2.1 Updated GUI. New features are added.

January, 2019 CPS RG-1000e, R3.0Updated GUI. New features IP remoteprogramming and firmware updating are added.MTM5*** sample setting screenshots are added.

Page 6: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

5Introduction

CPS RG-1000e User Guide

Introduction

This guide describes the following features:

· how to install RG-1000e CPS,

· how to connect the RG-1000e GATEWAY to the computer's USB port,

· RG-1000e CPS interface and main features,

· MOTOTRBO radio parameters to work with a RG-1000e GATEWAY,

· SmartPTT Radioserver settings to work with a RG-1000e GATEWAY.

Page 7: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

6Cables compatability chart

CPS RG-1000e User Guide

Cables compatability chart

SmartPTT 9.3 and

earlier

SmartPTT 9.4

C-DM4 ver 0 (RG-1000e s\n <=250) + +

C-DM4 ver 1 (RG-1000e s\n =>251) + +

C-MTM ver 0-0 (RG-1000e s\n <=250) + -

C-MTM ver 0-1 (RG-1000e s\n <=250) + +

C-MTM ver 1-0 (RG-1000e s\n =>251) + -

C-MTM ver 1-1 (RG-1000e s\n =>251) + +

C-APX ver 0-0 (RG-1000e s\n <=250) + -

C-APX ver 0-1 (RG-1000e s\n <=250) + +

C-APX ver 1-0 (RG-1000e s\n =>251) + -

C-APX ver 1-1 (RG-1000e s\n =>251) + +

C-GM ver 0-0 (RG-1000e s\n <=250) + -

C-GM ver 0-1 (RG-1000e s\n <=250) + +

C-GM ver 1-0 (RG-1000e s\n =>251) + -

C-GM ver 1-1 (RG-1000e s\n =>251) + +

C-Generic I-O ver 0-0 (RG-1000e s\n <=250) + -

C-Generic I-O ver 0-1 (RG-1000e s\n <=250) + +

C-Generic I-O ver 1-0 (RG-1000e s\n =>251) + -

C-Generic I-O ver 1-1 (RG-1000e s\n =>251) + +

Page 8: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

71. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1. RG-1000e Customer Programming Software(RG-1000e CPS)RG-1000e CPS is intended for the specialist engineers who perform the RG-1000e GATEWAY configuration for

remote management of the control radio station.

When reading the RG-1000e GATEWAY configuration, RG-1000e CPS defines the gateway type automatically.

RG-1000e CPS enables you to perform the following basic features:

· To gain access to the RG-1000e GATEWAY's configuration (download, read, write) and its modification.

· To update and recover the RG-1000e GATEWAY's processor program.

· To control the remote radio stations over the IP network.

RG-1000e CPS is designed for operation in Windows XP, Windows 7, Windows 8/8.1, Windows 10.

Note: RG-1000e CPS R3.0 can be used only for the RG-1000e GATEWAYs with firmware version R3.0.

Page 9: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

81. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.1 Software installation

To install RG-1000e CPS, copy the Program folder from the unpacked distribution kit to your local disk and run

the RG-1000e-XVXX.exe file.

When copying the folder with the program, the program does not change the settings of the computer's operation

system, except for the installation of the gateway driver for the USB port.

Page 10: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

91. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.2 Connecting the RG-1000e to PC

RG-1000e may be connected to PC via USB port and via Ethernet port.

USB connection

Before connecting the gateway make sure that the computer and gateway have a common ground or one of them

is disconnected from the ground.

If the RG-1000e GATEWAY and computer are connected to different grounding mats, damage to the USB ports

may occur.

When you connect the RG-1000e GATEWAY to a USB port for the first time, the computer's operation system

will define the connection of the new device.

Now you should install the new device driver. Appendix 1 contains USB driver step-by-step installation procedure.

For set up USB connection between CPS RG-1000e and RG-1000e device you should:

- run CPS RG-1000e

- on the top line Menu line select Tasks -> Connect to gateway

- in pop-up window select Connection type to the gateway - USB and press Enter button

- if RG-1000e is connected properly in Reports window you see message Gateway RG-1000e connected to the

USB bus.

Page 11: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

101. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Ethernet connection

CPS RG-1000e R3.0 and firmware R3.0 allow IP remote access to RG-1000e for configuration, monitoring and

firmware updating.

For set up Ethernet connection between CPS RG-1000e and RG-1000e device you should:

- run CPS RG-1000e;

- on the top line Menu line select Tasks -> Connect to gateway;

- in pop-up window select Connection type to the gateway - Network, select proper Network interface address of

PC ethernet adapter, specify The network address of the gateway, specify TCP gateway port;

- press Enter button.

if RG-1000e is connected properly in Reports window you see message like The gateway is connected

192.168.200.1[51130] <=> 192.168.100.1[30010]

Note! For remote IP access to RG-1000e it needs to configure one IP channel for remote access

purposes, and link this particular IP channel with Radio 1 or Radio 2 ports regardless real these ports

using. See Sample IP settings for remote IP access to RG-1000e. Setting may be done using USB

connection with RG-1000e.

Attention! When you reboot RG-1000e, that should be done every time when the device is programmed

with new settings, IP connection between CPS RG-1000e and the gateway will be closed.

It is normal equipment behavior. To continue perform operations under RG-1000e remotely via IP link it

needs to reestablish IP connection manually.

Page 12: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

111. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3 CPS interface and main features

1.3.1 CPS control panels

RG-1000e CPS has the following panels:

· The RG-1000e (Gateway) panel for operation with the RG-1000e GATEWAY configuration.

· The Report panel for program messages output.

· The File panel allows you to create, open and save the configuration files by clicking the Create , Open

, and Save or Save as buttons correspondingly.

You can also perform these actions via the File menu in the main menu of the program.

· The Tasks panel allows you to connect to the gateway, read and write the gateway configuration, and reboot by

clicking corresponding button

Connect to gateway Read , Write Reboot

You can also perform these actions via the Tasks menu in the main menu of the program or via the Tasks menu

on the RG-1000e (Gateway) panel.

To open the required panel, click Panels in the main menu of the program or right click in the area of the main

menu and click the corresponding panel name.

When downloading the RG-1000e GATEWAY configuration, the corresponding panel is opened automatically.

To hide the panel, click its Cross button or click Panels or right click in the area of the main menu and click the

required panel name.

Page 13: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

121. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.2 Operation with configuration files

RG-1000e CPS enables you to work with a gateway configuration file in MCD format which contains the settings

defining the RG-1000e GATEWAY operation via the RG-1000e (Gateway) panel.

You can perform the following actions with the configuration files:

· create configuration file with the default settings,

· open configuration file,

· save configuration file,

· read configuration from the RG-1000e GATEWAY, and

· write configuration to the RG-1000e GATEWAY.

To create a configuration file:

1. Click File > Create, or click Create in the File panel, or press Ctrl+N together. At that, the Save As window

will open.

2. In case of gateway configuration file creation, click Yes in the window that opened.

To open the configuration file:

1. Click File > Open, or click Open in the File panel, or press Ctrl+O together. At that, the Open window will

open.

2. Select the required file and click Open.

To save the configuration file:

1. Click File > Save, or click Save in the File panel, or press Ctrl+S together. At that, the Save As window will

open.

2. Specify the file name in the corresponding field and click Save. You can also save the configuration file by

clicking File > Save as, or clicking Save as in the File panel.

To read the configuration from the RG-1000e GATEWAY, click Tasks > Read, or click Read in the Tasks panel.

To write the configuration to the RG-1000e GATEWAY, click Tasks > Write, or click Write in the Tasks panel.

Attention! Do not forget to reboot RG-1000e every time when the device is programmed with new

settings:

- turn-off power for 7-10 sec and then turn-on (using Power button on RG-1000e front panel)

- or press Reboot button on CPS RG-1000e GUI console and confirm action.

Otherwise new settings will not be applied properly.

Attention! When you reboot RG-1000e IP connection between CPS RG-1000e and the gateway will be

closed. It is normal equipment behavior. To continue perform operations under RG-1000e remotely via

IP link it needs to reestablish IP connection manually.

Page 14: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

131. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3 Gateway panel

The RG-1000e panel has the tree structure, which is created when creating

the RG-1000e GATEWAY configuration file or reading the configuration from

the RG-1000e GATEWAY. This tree structure combines the sections of

gateway devices with various RG-1000e GATEWAY configuration operations.

The RG-1000e panel helps to perform the following RG-1000e GATEWAY

configuration operation:

· reading / writing configuration files and updating the RG-1000e GATEWAY

firmware,

· modifying the settings, and

· getting statistic reports on the operation of gateway modules.

To perform these operations, double-click the corresponding section in the panel tree:

· the Tasks section contains the operations listed in the Tasks panel description,

· the Network section,

· the Radio1&2 section,

· the Other section,

· the Statistics section,

· the Monitor section,

· the Info section.

Page 15: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

141. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.1 Network section

The Network section contains the following gateway network parameters:

· eight IP channels,

· IP channel connection to the RG-1000e GATEWAY interfaces in the Mux subsection, and

· Ethernet port operation mode in the Driver subsection.

Page 16: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

151. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

IP channel

The IP channel window contains the network parameters of the corresponding IP channel.

Note: When the RG-1000e GATEWAY uses several IP channels, the TCP and UDP port number values must not

coincide.

To open the IP Channel window, double-click the required IP Channel on the RG-1000e panel.

The RG-1000e GATEWAYs have the following parameters:

· Mode/connection protocol, has the following values

o Server mode, the mode is for operation with SmartPTT Radioserver.

o TCP / RTP, the protocol is for operation with SmartPTT Radioserver.

o Client mode, the mode is not used with SmartPTT Radioserver.

o M-270/LCP, the protocol is not used with SmartPTT Radioserver.

· Getaway settings:

o IP address, Subnet mask, Gateway: The network parameters.

o XCMP protocol port, 1025..65535: UDP / TCP control command ports in accordance with the connection

protocol.

Page 17: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

161. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

o RTP thread ports:

- Audio: The port of audio signal transmission from radio station to radioserver and backwards over the RTP

streams. This port is used for operation with the TCP / RTP connection protocol.

- ARS: The transmission port of data on registration of MOTOTRBO subscribers in the network. This port is

used for operation with the TCP / RTP connection protocol.

- TMS: The transmission port of text messages between the MOTOTRBO subscribers and readioserver. This

port is used for operation with the TCP / RTP connection protocol.

- Location: The transmission port of requests and messages about the location of MOTOTRBO subscribers

(GPS). This port is used for operation with the TCP / RTP connection protocol.

- Telemetry: The transmission port of requests and messages about the state of MOTOTRBO radio stations

telemetry contacts (GPS). This port is used for operation with the TCP / RTP connection protocol.

Attention! Do not use port 30010 for regular SmartPTT operations. The only port 30010 provides remote

Audio Monitor feature (in the Monitor section of CPS RG-1000e). It is strongly recommended to use port

30010 as the designated port for IP remote access to RG-1000e.

Note! The same port, for instance port 30020, may be used for XCMP, Audio, ARS, TMS, Location and

Telemetry services within one selected IP channel.

Attention! The same port or ports can not be shared between two or more IP channels. For each IP

channel unique port or ports must be assigned.

· Remote getaway settings. It is not used with SmartPTT Radioserver operations.

- IP address, the address of remote RG-1000e GETAWAY

- XCMP port protocol, the port of remote remote RG-1000e GETAWAY.

These settings are used when Radio Interface Mode is defined as Repeater. See chapter 1.3.3.2 Radio section /

Settings. See an additional document how to configure RG-1000e GATEWAYs to use Radio ports in Repeater

mode.

Page 18: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

171. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Mux

The Mux window serves for the IP channel distribution between the RG-1000e GATEWAY interfaces. The IP

channels, not connected to any interface, are considered to be disabled and are not used by the RG-1000e

GATEWAY.

The IP channels that are not used by the RG-1000e GATEWAY must be disabled.

To open the Mux window, double-click Mux on the RG-1000e panel.

In the given example of the Mux window you can see that:

· Radio 1 interface is connected to IP channel 1.

· Radio 2 interface is connected to IP channel 2.

You may assign several IP Channels for Radio 1 and Radio 2. For instance, two SmartPTT radioservers may

communicate with Radio 1 via IP Channel 1 and IP Channel 3.

For this case you should check boxes IP Channel 1 and IP Channel 3 for Radio 1 in the Mux window.

Page 19: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

181. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Driver

The Driver window serves for the management of the following LAN RG-1000e GATEWAY operation modes:

· MDI/MDIX: The type of the connecting Ethernet cable, straight-through or crossed cable.

· Auto-Negotiation: Auto-negotiation of data transmission speed and mode.

· Fixed values of data transmission speed and mode.

To open the Driver window, double-click Driver on the RG-1000e panel.

When the Ethernet interface operates, side emission from the local network cable can penetrate into the radio

station receiver antenna. On some frequencies it can lead to radio station receiving of interference from the RG-

1000e GATEWAY Ethernet interface. To reduce side emissions, the RG-1000e GATEWAY enables the user to

control the Ethernet interface transmitter power. Power reduction decreases the emission level from the Ethernet

cable. But it also can lead to the error increase in the Ethernet packets reception depending on the connected

network equipment. You must check experimentally the compatibility and operational reliability of network

equipment in partial operation mode. You can set the transmitter power for operation with 5 meter cable only in

exceptional cases, and you must control the processes of reception and transmission of the Ethernet packets.

Page 20: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

191. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Sample IP settings for remote IP access toRG-1000e

Pictures below show IP settings sample for IP remote access to RG-1000e.

It is recommended to use IP channel 8 for IP remote access, since usually no more than two IP channels are

used for SmartPTT operations and IP channel 8 typically is free.

Port 30010 is used for IP remote access and can not be reused for regular SmartPTT operations. Technically,

different ports may be used for IP remote access, but only port 30010 provides remote Audio Monitor feature (in

the Monitor section of CPS RG-1000e). This why we recommend to use port 30010 only for IP remote access.

In MUX tab settings IP channel 8 is linked with Radio 2 port, regardless real using Radio 1&2 ports.

There are no ways to get remote IP access to RG-1000e if IP channel that configured for IP remote access is not

linked with Radio 1 or Radio 2 ports.

Page 21: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

201. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

For this particular sample in Connection to the gateway pop-up window setting gaps should be filled as shown on

the picture below.

Page 22: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

211. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.2 Radio 1&2 section

The Radio section contains the interface parameters for the radio station connection to the RG-1000e

GATEWAY.

The parameter control is performed via the following subsections:

· Radio 1: It serves for operation mode control of digital lines and analog inputs/outputs of the RG-1000e

GATEWAY RADIO 1 port.

· Radio 2: It serves for operation mode control of digital lines and analog inputs/outputs of the RG-1000e

GATEWAY RADIO 2 port

Both the Radio 1 and Radio 2 subsections have the Settings, Audio RX, Audio encoder RX, Audio TX,

Audio TxH and Audio encoder TX settings panels, which are described below.

Page 23: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

221. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Settings

The Settings window defines operation modes of the RG-1000e GATEWAY interface lines depending on the type

of connecting control panel or radio station model. RG-1000e GATEWAY general settings include the following

components:

To open the Settings window, double-click Settings on the RG-1000e panel in the Radio section.

RG-1000e may operate in several modes. It allows to use RG-1000e as the part of SmartPTT dispatching system

and as the independent device (without integration with SmartPTT).

Available Radio 1(2) Interface modes:

o Disabled: The RG-1000e GATEWAY does not use the interface.

o Motorola DM: The RG-1000e GATEWAY lines are set to operate with MOTOTRBO mobile radios

o Radio I\O: The RG-1000e GATEWAY lines are set to operate with non-MOTOTRBO mobile radios using

GPIO lines for connection with radios.

o Bridge:This mode allows for several RG-1000e GATEWAYs communicate directly to each other and create

simplest distributed radio networks. The RG-1000e GATEWAY lines are set to operate with various donor

radios using GPIO lines for connection with radios.

o Transit audio:This mode allows for several RG-1000e GATEWAYs communicate directly to each other and

create simplest distributed networks for audio streaming.

Page 24: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

231. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Note: Motorola GM mode is not supported.

This User Guide describes how to configure Radio 1(2) interface for operation in Motorola DM and Radio I\Omodes.

Page 25: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

241. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Motorola DM mode

· Interface mode:set Mototrbo DM, select DM4000 for High Tier Mototrbo donor radio or DM2600 for Middle Tier

Mototrbo donor radio.

· Power from connected device: This option allows to get power for the RG-1000e via Radio 1 (or Radio 2)

socket, pin 25. It is recommended turn-On this box for Mototrbo DM mode

Attention! For detailed information about available power options and proper hardware installation you

must read "RG-1000e Gateway User Guide" chapter 4.

· On\Off control to connected device: This option allows to change Radio 1 (or Radio 2) socket pin 13 status.

If IP connection between SmartPTT radioserver and the RG-1000e gateway is active - pin 13 status is High

(12VDC). If no IP connection between SmartPTT radioserver and the RG-1000e gateway - pin 13 status is Low

(0VDC) It allows to use pin 13 for On-Off control purposes.

Attention! Do not turn-On simultaneously both boxes Power form connected device and On\Off control to

connected device. Once IP link between SmartPTT radioserver and the RG-1000e is down there are no

ways to turn-On the connected radio again.

· Sync IP channels: This mode enables to synchronize command transmission when operating with several

radioservers. The commands are transmitted serially, after receiving the command reception confirmation from

all remote radio stations. If the confirmation is not received from at least one radio station, the other command

transmission will be blocked for The synchronization timer IP channels time.

· The synchronization timer IP channels: This mode sets the hold time of the command reception

confirmation from all remote radio stations. Recommended value is 1500 ms.

Page 26: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

251. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

· Loop-back TX microphone audio on IP channels: This option allows to share Radio 1 (or Radio 2) voice

traffic between multiple IP channels. For correct voice sharing operations you should also configure Encoder

audio L-b section.

The Settings tab defines the additional gateway interface settings accordance with the selected operation mode.

Example below shows setting for Mototrbo DM mode.

Control mode PTT : The selection of control mode between the discrete line or XCMP command transmission via

USB. It is recommended to use the USB interface.

Control mode CSQ: It is recommended to use the USB interface.

Keep USB/IP link if Ethernet/IP link is down: RG-1000e with firmware 1.0&1.1 automatically closes USB\IP

link (connection to a controlled radio) if Ethernet/IP link is down. Since firmware 2.0 RG-1000e may be configured

to keep USB/IP connection to a controlled radio regardless Ethernet/IP status. It is recommended to set it

Enable.

Ports network service radio: The radio station UDP port numbers, used for data transmission of corresponding

services. These port numbers must coincide with ports of services which are written in the MOTOTRBO Customer

Programming Software (CPS) and radioserver settings for the given connection (see step 4 in the MOTOTRBO

radio settings section).

Page 27: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

261. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Radio I\O mode (for SmartPTT 9.3 and above)

· Interface mode:set Radio I\O.

· The type of connected device: select Not defined.

· Audio TX Out rated level: select 80 mV.

· Power from connected device: Disable this option for I\O mode if it is not necessary to deliver power to RG-

1000e form an external\connected device\radio.

· On\Off control to connected device: Disable this option for I\O mode.

· Sync IP channels: This mode enables to synchronize command transmission when operating with several

radioservers. The commands are transmitted serially, after receiving the command reception confirmation from

all remote radio stations. If the confirmation is not received from at least one radio station, the other command

transmission will be blocked for The synchronization timer IP channels time.

· The synchronization timer IP channels: This mode sets the hold time of the command reception

confirmation from all remote radio stations. Recommended value is 1500 ms.

· Loop-back TX microphone audio on IP channels: This option allows to share Radio 1 (or Radio 2) voice

traffic between multiple IP channels. For correct voice sharing operations you should also configure Encoder

audio L-b section. For regular I-O mode operations this setting is not required.

Page 28: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

271. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

The Settings tab defines the additional gateway interface settings accordance with the selected operation mode.

· Audio& PTT/CSQ lines mode:use Simplex.

· "CH Activity" sign source RX: This option defines how RG-1000e will be notified about qualified incoming

activity on RX path.

o OFF: disable.

o CSQ: based on CSQ discrete signal from a connected donor radio.

o VOX: based on internal VOX status.

o CSQIVOX: based on CSQ discrete signal from a connected donor radio or based on internal VOX status.

o CSQ&VOX: both CSQ and VOX conditions should be fulfilled simultaneously.

· Emulation call SMART PTT: Disable.

Page 29: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

281. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

The Pins tab defines Radio 1(2) port pings settings.

Recommended pins settings are:

- pin 3: Output control PTT.

- pin 17&16: Input carrier detect (CSQ \COR\PL detect\TG detect).

- pin 12 for RG-1000e ith S/N =>*****251 (pin 25 for RG-1000e ith S/N <=*****250): for SmartPTT_9.4 set 9.5 V, for

SmartPTT_9.3 set 0V.

Optionally pins 4, 5, 6, 18 may be used for Channel Select on a connected donor radio (if a connected donor radio

has Channel Select GPIO lines on acc. connector).

Page 30: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

291. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Radio I\O mode (for SmartPTT 9.2 and earlier)

· Interface mode:set Radio I\O.

· The type of connected device: select Not defined.

· Audio TX Out rated level: select 80 mV.

· Power from connected device: Disable this option for I\O mode if it is not necessary to deliver power to RG-

1000e form an external\connected device\radio.

· On\Off control to connected device: Disable this option for I\O mode.

· Sync IP channels: This mode enables to synchronize command transmission when operating with several

radioservers. The commands are transmitted serially, after receiving the command reception confirmation from

all remote radio stations. If the confirmation is not received from at least one radio station, the other command

transmission will be blocked for The synchronization timer IP channels time.

· The synchronization timer IP channels: This mode sets the hold time of the command reception

confirmation from all remote radio stations. Recommended value is 1500 ms.

· Loop-back TX microphone audio on IP channels: This option allows to share Radio 1 (or Radio 2) voice

traffic between multiple IP channels. For correct voice sharing operations you should also configure Encoder

audio L-b section.For regular I-O mode operations this setting is not required

Page 31: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

301. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

The Settings tab defines the additional gateway interface settings accordance with the selected operation mode

.

· The mode of operation of the radio:use Simplex.

· "CH Activity" sign source: This option defines how RG-1000e will be notified about qualified incoming activity

on RX path.

o OFF: disable.

o CSQ: based on CSQ discrete signal from connected donor radio.

o VOX: based on internal VOX status.

o CSQIVOX: based on CSQ discrete signal from connected donor radio or based on internal VOX status.

o CSQ&VOX: both CSQ and VOX conditions should be fulfilled simultaneously.

Page 32: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

311. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

SmartPTT 9.2 and earlier versions don't support native RG-1000e Radio I\O mode. For using SmartPTT 9.2 and

earlier versionswith non-Mototrbo donor radios it needs to turn-On and configure SmartPTT Emulation Call feature

in RG-1000e settings

· Emulation call SMART PTT: set Group.

· Donor Radio ID: specify desirable ID. Attention! Donor Radio ID must match corresponding Remote

control Station Radio ID (in SmartPTT Radioserver settings).

· Subscriber Radio ID: specify desirable ID that will be used for incoming calls as Caller ID.

· Group ID: specify desirable ID. Attention! Group ID must match corresponding Group ID (in SmartPTT

Radioserver settings).

Note! PTT button, assigned for this Talkgroup ID on SmartPTT Dispatcher console, should be used for

outgoing calls.

Page 33: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

321. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Call Hangtime: set 1 sec.

The Pins tab defines Radio 1(2) port pings settings.

Recommended pins settings are:

- pin 3: Output control PTT.

- pin 17&16: Input carrier detect (CSQ \COR\PL detect\TG detect)

- pin 12 for RG-1000e ith S/N =>*****251 (pin 25 for RG-1000e ith S/N <=*****250): for SmartPTT_9.3 & 9_2 set

0V.

Page 34: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

331. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Audio RX

The Audio RX window defines settings of the RG-1000e GATEWAY analog inputs.

To open the Audio RX window, double-click Audio RX on the RG-1000e panel in the Radio section.

· Inputs:

o 1: It is a line balanced\unbalanced input that is connected to the radio station Rx Audio

output.Recommended attenuation setting is 0 dB and Differential input is On.

o 2: It is a unbalanced input with external attenuator and additional amplifier for receiver signal input from non

typical audio sources

· Amplifier: If it is required, it can provide the input signal gain.

Rated input signal level without gain is 330 mV (unbalanced mode).

Recommended gain value is 8 dB.

Input overload control is performed on the base of input signal meter in the Monitor > Audio input section of the

corresponding interface.

Page 35: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

341. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Audio coder RX

The Audio coder RX windows define the settings of the input audio signal coding (for Radio 1 and Radio 2

independently).

To open the Audio coder RX window, double-click Audio coder RX on the RG-1000e panel in the Radio 1 or

Radio 2 section.

· Control:

o Disable (CSQ and VOX both boxes are unchecked): RG-1000e continuously streams audio to IP network.

o CSQ: RG-1000e streams audio to IP network only if a connected donor radio sends CSQ signal to RG-1000e.

CSQ is recommended setting and used to reduce IP traffic. For proper CSQ signal processing you should:

- for Radio 1(2) port Mototrbo DM mode: select Control Mode CSQ - USB interface (see Radio 1(2)

settings - Settings tab)

- for Radio 1(2) port I\O mode: set one pin as Input Carrier Detect (see Radio 1(2) settings - Pins tab) and

connect this pin to a corresponded pin on connected control station acc. connector.

o VOX: RG-1000e streams audio to IP network if RG-1000e internal VOX trigger has Active status.

· The encoding mode:

o Mu-Law / A-Law 64 kbps: The audio processing by G.711 standard. SmartPTT recommend setting is u-Law 64

kbps.

· Duration audio package: The total duration of audio data in the generated packet, recommended setting is

20 ms.

Page 36: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

351. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

RG-1000e internal VOX may be used if RG-1000e is pre-programmed to interact with non-Mototrbo contral station

that doesn't have on acc. connector such signals as CSQ\PL Detect\TG Detect.

Note! RG-1000e internal VOX can not be used if incoming audio signal sourced directly from FM

demodulator. RG-1000e internal VOX may work properly if incoming audio signal is qualified as

"squelched".

Also RG-1000e internal VOX may operate with audio signal sourced from donor radio speaker <+> and

<-> signal lines. In this case a donor radio speaker volume should be fixed using suitable programming

software.

· Detector of signal level, VOX: On-Off internal VOX .

· VOX status for signal detector: Allows to use internal VOX status as pseudo CSQ signal status (see

corresponding settings for I\O mode: Radio 1(2) settings - Setting, CH Activity signal source)

· Signal level ON: Threshold On audio level, mV.

· Detect time: Threshold On time duration, ms. If incoming audio level is more than threshold On audio level for

the period of time more than Threshold On time duration: internal VOX trigger gets Active status.

· Signal level OFF: Threshold Off audio level, mV.

· Release time: Threshold Off time duration, ms. If incoming audio level is lower than threshold On audio level for

the period of time more than Threshold Off time duration: internal VOX trigger gets Inactive status.

Note! Recommended correlation Signal level ON \ Signal level OFF is 3:1.

Note! Recommended minimum Release time is 500 ms.

Figure below shows recommend Audio encoder RX settings for MTM5**** donor radios.

Page 37: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

361. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Audio TX

The Audio TX window defines the analog output parameters.

Audio TX enables the connection of signals from different audio channels to the output.

To open the Audio TX window, double click Audio TX on the RG-1000e panel in the Radio section.

Recommended settings for control stations are 0 dB for Radio 1 TX output and 7 dB of gain value for Amplifier.

Page 38: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

371. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Audio TxH

The Audio TxH window defines the analog parameters for audio outputs with high output impedance.

Selector signals enables the connection of signals from different audio channels to the output.

To open the Audio TxH window, double click Audio TxH on the RG-1000e panel in the Radio section.

For regular Mototrbo\SmartPTT operations keep all boxes unchecked.

Page 39: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

381. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Encoder audio L-b

The Encoder audio L-b windows define the settings of loop-back audio stream using for voice traffic sharing

between multiple SmartPTT radioservers (for Radio 1 and Radio 2 independently).

Usually this feature in nor used for regular SmartPTT operations. Just keep settings as it shown on the figure

below.

Page 40: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

391. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.3 Other

The Other section contains the following parameters:

· Audio decoders TX: It serves for operation mode control of the audio decoder of the corresponding IP channel.

· Recorder: It serves for operation mode control of the recorder of the corresponding IP channel.

Page 41: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

401. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Audio decoder TX

The Audio decoders TX windows define buffer sizes of audio decoders for jitter compensation of received audio

data packets (for each IP Channel independently).

To open the desirable IP Channel Decoder microphone window, double-click Audio decoders TX on the RG-

1000e panel in the Other section, and next double-click required Channel for setting.

In case of big packet jitter in the IP network, it is recommended to change the audio decoder parameters of

working IP channels:

· Managing the duration of the buffer: Select Fixed .

· The duration of the buffer: Select 180 ms.

Page 42: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

411. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Recorder

The Recorder section combines the control parameters and regulators of audio signals transmitted to output for

communications recorder connection.

Note: Attention! The given settings do not influence on the interaction of RG-1000e GATEWAY and radioserver,

they are necessary only for third-party devices connection to the RG-1000e GATEWAY.

To open the Recorder window, double-click Recorder on the RG-1000e panel.

The Control tab provides a choice of digital signals for audio signal enabling/disabling.

It is recommended to select all check boxes in the Radio 1, the control signals and Radio 2, the control

signals sections of the Control tab.

The Signals tab contains the selector of audio signals incoming to the recorder and variable output amplifier with

control interval from 0 to 9 Db. The selector channels have variable attenuators with control interval from -78,3 to 0

Db.

Page 43: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

421. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

To forward to Recorder port audio only from Radio Port, select the Receiver 1 and Microphone 1 check boxes

only.

To record audio from Accessory Connector, select the Receiver 2 and Microphone 2 check boxes only.

You may keep signal levels settings with 0 dB of gain value, as it is shown on the picture above.

Page 44: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

431. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.4 Statistics section

This section provides useful technical information which helps to

perform RG-1000e GETAWAY implementation.

The Statistics section combines statistic reports on the operation

of the following components:

· controller,

· interfaces for connection of radio station or control terminal,

· network interface, and

· IP channels.

To start/stop reporting from the RG-1000e GATEWAY, click the

Start or Stop button in the window of corresponding report. The statistic data is updated periodically at 1 second

intervals.

Statistic counters are of 32 bits, if the counter is overflowed, the counter will be reset and it will continue to count.

To reset the counter to "0", click Reset in the report window.

Page 45: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

441. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Common

The Common window contains the reports on the loading status of the RG-1000e GATEWAY processors and on

network interface status.

To open the Common window, double-click Common on the RG-1000e panel in the Statistics section.

Click Start to see real-time Common information. Click Stop to terminate monitoring process.

Page 46: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

451. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Page 47: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

461. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Radio

The Radio window contains the reports on the interface operation mode, connected IP channels and other data on

operation.

To open the Radio window, double-click the required Radio on the RG-1000e panel in the Statistics section.

Click Start to see real-time information about the selected Radio. Click Stop to terminate monitoring process.

Figure above shows:

- Radio 1 port operates in Mototrbo DM mode,

- Radio 1 post has active connection with a remote node via IP channel 1,

- Radio 1 port has active connection with the connected radio,

- Radio 1 port has active connection with a remote application,

- Radio 1 is detecting incoming call activity from connected Mototrbo radio.

Page 48: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

471. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Network

The Network window contains the information on:

· the operation of network interface driver,

· the operation of network protocols, and

· received and transmitted data for the Radio interfaces.

To open the Network window, double-click Network on the RG-1000e panel in the Statistics section.

Click Start to see real-time information about the Network. Click Stop to terminate monitoring process.

Page 49: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

481. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Page 50: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

491. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Page 51: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

501. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

IP channel

The IP Channel window contains the report on the operation of data transmission protocol and audio decoder of

the corresponding IP channel.

To open the IP Channel window, double-click the required IP Channel on the RG-1000e panel in the Statistics

section.

Click Start to see real-time information about the IP Channel. Click Stop to terminate monitoring process.

Page 52: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

511. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Page 53: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

521. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

Page 54: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

531. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.5 Monitor section

The Monitor section combines the windows of input and output

oscillograms of the RG-1000e GATEWAY interface audio signals.

The oscillograms are output in real time at sampling frequency of

8 kHz.

To open the oscillogram window, click the required Audio input

or Audio output on the RG-1000e panel in the Monitor section.

You can see the example of the oscillogram for Audio input 1 below.

Page 55: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

541. RG-1000e Customer Programming Software (RG-1000e CPS)

CPS RG-1000e User Guide

1.3.3.6 Info section

The RG-1000e - Info window contains the RG-1000e GATEWAY model description, serial number and numbers of

processor software versions.

To open the RG-1000e - Info window, double-click Info on the RG-1000e panel.

Page 56: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

552. Radio settings

CPS RG-1000e User Guide

2. Radio settings

This section describes the radio settings that are directly related to the interaction with a RG-1000e GATEWAY

and does not cover all other radio settings.

2.1 MOTOTRBO settings

Firmware version of the MOTOTRBO radio connected to a RG-1000e GATEWAY can't be older than R02.40.10.

Before connecting the MOTOTRBO radio to the RG-1000e GATEWAY in the MOTOROLA DM mode, it is required

to configure the following radio parameters in MOTOTRBO CPS:

1. Set up the accessory connector modes. Click the Accessories tab in the radio settings and in the Top

section specify the following values:

· Select Filtered Squelch in the RX Audio Type field, and

· Select Rear PC & Audio in the Cable Type field.

2. In the Top section of the Accessory tab specify the following values for Pin #17:

Page 57: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

562. Radio settings

CPS RG-1000e User Guide

· Select Ext Mic PTT in the Feature column, and

· Select Low in the Active Level column.

3. Click the Network tab in the radio settings. In the Radio Network section, select Via USB in the Forward to

PC field.

Page 58: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

572. Radio settings

CPS RG-1000e User Guide

4. In the Network tab, ensure that the UDP ports values of the Telemetry, ARS, TMS and Location services

match the corresponding values, configured in the gateway (see the Settings tab of the Settings subsection in

the Radio section of the Controller panel). Check the values in the following fields:

· the Telemetry UDP Port field in the Radio Network section,

· the ARS UDP Port field in the Services section,

· the TMS UDP Port field in the Services section, and

Page 59: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

582. Radio settings

CPS RG-1000e User Guide

· the Location Server UDP Port field in the Control Station section.

Page 60: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

592. Radio settings

CPS RG-1000e User Guide

Page 61: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

602. Radio settings

CPS RG-1000e User Guide

2.2 non-Mototrbo settings

2.2.1 CDM\PRO

CDM\PRO mobile radios

1. Radio configuration menu, Accessory Configuration tab, · Select Flat Audio in the Rx Audio Type,

· Select Ext Mic Audio in the External PTT Audio Source,

· Set 100 msec in the Accessory Debounce Duration.

2. Radio configuration menu, Accessory Pins tab,

· Set pin 3 - External Mic PTT, active level low,

· Set pin 4 - PL and CSQ Detect\Talkgroup Detect, active level low,

Optionally pins 6, 8, 12, 14 may be used for channel switching

Page 62: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

612. Radio settings

CPS RG-1000e User Guide

· Set pin 6 - Channel Select 1, active level low,

· Set pin 8 - Channel Select 2, active level low,

· Set pin 12 - Channel Select 3, active level low,

· Set pin 14 - Channel Select 4, active level low.

Page 63: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

622. Radio settings

CPS RG-1000e User Guide

2.2.2 XPR8300\XPR8400\XIRR8200

XPR 8300\XPR8400\XIRR8200 repeaters (valid only for analog mode)

Accessory menu

· Select Filtered Squelch in the Audio Type,

· Select External PTT in the Audio Priority,

· Set 100 msec in the Debounce Duration,

· Set pin 17 - External Mic PTT, active level low,

· Set pin 19 - PL\Talkgroup Detect, active level low.

Optionally pins 20, 21, 22 may be used for channel switching.

Page 64: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

632. Radio settings

CPS RG-1000e User Guide

2.2.3 MTM5***

Screen-shots below show settings that are important for proper communication between МТМ5*** и RG-1000e.

Disable all tones, except Group Call Recieved Tone.

Page 65: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

642. Radio settings

CPS RG-1000e User Guide

Set Active Accessory Selection = Transceiver Accessory.

Page 66: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

652. Radio settings

CPS RG-1000e User Guide

Set Rx Audio Line Output Type = 0dBr.

Page 67: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

662. Radio settings

CPS RG-1000e User Guide

Set Line In Rear Accy = Line-In.

Page 68: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

672. Radio settings

CPS RG-1000e User Guide

Check settings below, it should be as presented.

Page 69: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

682. Radio settings

CPS RG-1000e User Guide

Check General Notification - Group Call Received settings, Scale Factor should be -20 and Total level should be -26.

Page 70: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

692. Radio settings

CPS RG-1000e User Guide

Check General Notification Field Value should be -6.

Page 71: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

702. Radio settings

CPS RG-1000e User Guide

Disabled Call Recorder Output.

Page 72: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

713. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3. SmartPTT Radioserver settings

The SmartPTT Radioserver can be configured in different ways to work with the RG-1000e GATEWAY. It depends

on the topology of the MOTOTRBO network to which the radioserver is connected.

3.1 Interaction with Mototrbo remote control stations indirect communication mode or with the use of singlerepeater (IP Site Connect network)

Radio network topologies and examples of SmartPTT dispatching systems for this radioserver configuration are

described in details in the "RG-1000e Remote Gateway" user guide. See the following sections in the guide:

· "Direct Mode communication between the radio stations (Talkaround) in digital or analog mode", and

· "System topology with the use of a single repeater or the IP Site Connect network".

For connection to each of the pre-configured IP channels on the RG-1000e GATEWAY, a separate connection on

the radioserver (remote MOTOTRBO control station) should be created.

To create the connection to the RG-1000e GATEWAY in the Direct Mode communication between the radio

stations or for working with the repeater, configure the following settings in SmartPTT Radioserver Configurator:

1. Right click Control Stations in the setting tree of SmartPTT Radioserver Configurator.

2. Click Add > Remote MOTOTRBO control station.

Page 73: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

723. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3. In the window that opens specify the parameters of the connection to the remote control station.

Active: Activates the connection to the remote control station. To disable the remote control station from the

connection list, clear the Active check box.

Name: Remote control station arbitrary name.

Page 74: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

733. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Remote gateway IP address: Gateway network IP address. The IP address in this field must match the value

specified in the settings of the gateway IP channel for this remote control station. See in RG-1000e CPS, the

corresponding IP channel window in the Network section.

XCMP port: The gateway port. The XCMP port in this field must match the value specified in the corresponding

field in RG-1000e CPS. See the Port XCMP protocol field in the IP channel window of the Network section.

Local interface: The local interface used for connection to the RG-1000e GATEWAY.

Radio ID: Unique identifier of the remote control station. Radio ID is to be set in the range from 1 to 16776415.

CAI Network: CAI network identifier. To be set in the range from 1 to 126. Use the default value of 12.

CAI Network for Groups: Group CAI network identifier. To be set in the range from 225 to 239. Use the default

value of 225.

Transmit Data Only: If selected, the remote control station is used for data transmit only and is not displayed in

SmartPTT Dispatcher and is not available for voice calls.

Allow Telephone Interconnect: Allows you to enable voice calls to telephone subscribers.

GPS: Enables location service which provides coordinates of the subscribers, whose radios are equipped with a

built-in GPS receiver.

ARS: Enables registration service. When the radio powers up, the radio automatically registers with the server.

Port 4005 is used as default.

TMS: Enables the service for exchanging text messages between dispatchers and radio subscribers. Port 4007 is

used by default.

Telemetry Service: Enables the service responsible for transmitting and processing of telemetry signals between

SmartPTT Dispatcher and subscriber stations. Port 4008 is used by default.

Analog Call Hangtime: Virtual hangtime which is used for uniting analog calls into one. This was done to not

overload the event log with too many records of analog calls. During this hangtime the channel is not reserved,

anyone can start transmitting. The hangtime applies only if the remote control station is configured to operate in

analog mode.

GPS Transmission Mode: Allows you to select the way how to transmit location updates: as a data packet in

multiple bursts or as a single CSBK (Control Signaling Block). This time select Data.

Set local ports: Local ports that can be used for connection to the RG-1000e GATEWAY, if the default ports of

the corresponding services are already in use. By default the system occupies local ports automatically, but you

can define them manually.

4. Add or edit the channels of the remote control station in the Control Station Channels window. These

settings allows remote switching between the control station channels and must match with the radio settings

in the MOTOTRBO CPS.

Page 75: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

743. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Name: Channel alias visible to SmartPTT Dispatcher.

Zone: Serial number of a channel group. Information on the maximum possible number of zones and radio station

channels is shown in the following table.

ModelMaximum number of

zones

Maximum number of

channels per zone

Maximum total number of

channels

Mobile radio station

with display50 160 160

Mobile radio station

with seven-segment

display

2 32 32

Channel: Channel sequence number.

: Selected channel will be set at the control station, when you start the radioserver.

Copy: Copies added channels of the remote control station to the clipboard

Paste: Pastes copied channels of the remote control station from the clipboard.

Add: Adds a new channel.

Remove: Deletes the channel from the list.

To edit channel name, zone or channel number, place the cursor on the corresponding field and make changes.

Note: The maximum number of zones and channels of the MOTOTRBO control station depends on the model and

version of the parameter block.

5. In the Control Station Talkgroups window, add or edit the talkgroups, which the dispatcher(s) may use for

making a call via the remote control station.

Page 76: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

753. SmartPTT Radioserver settings

CPS RG-1000e User Guide

To add a talkgroup, click Add. To add All Call (is used in profiles), click All Calls. To change the order of groups

in the list, use the Up and Down arrows. The order defined in the window will be used in SmartPTT Dispatcher.

Name: Talkgroup alias displayed by the control station.

ID: Talkgroup unique identifier used during communications. To be set in the range from 1 to 16776415.

Copy: Copies added groups (their names and IDs) to the clipboard.

Paste: Pastes copied groups from the clipboard.

Remove: Deletes the selected talkgroup.

To edit talkgroup name or ID, set the cursor on the corresponding field and make changes.

6. To select audio devices and set up VoIP parameters, click Audio in the setting tree of SmartPTT Radioserver

Configurator. At that, the Audio Settings window will open.

The Active check box activates transmission and receiving of the audio signals for the remote control station.

Codec: Outgoing audio stream compression method. The recommended value is CCITT u-Law.

Page 77: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

763. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Format: Sampling frequency of an outgoing audio stream and the RTP packet size. The recommended value is

8000 Hz, 20 ms, 64 (86) kbps.

7. If you need to create more than one connection to the remote control stations, repeat steps 1 to 6 for each

new remote control station.

Page 78: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

773. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3.2 Interaction with Mototrbo remote control stations inthe Capacity Plus Legacy mode

Radio network topology and the example of SmartPTT dispatching system for this radioserver configuration are

described in details in the "RG-1000e — Remote Gateway" user guide. See the section "Example of system

topology in the Capacity Plus Legacy trunking network".

The parameters of the connection to the remote control stations in the Capacity Plus Legacy mode are configured

in the Capacity Plus Systems section of SmartPTT Radioserver Configurator. This guide does not cover the

common settings of the radio networks configuration. For more information about the Capacity Plus systems

configuration see the "SmartPTT Radioserver Configurator" software help file.

To add connection to the remote control stations in the Capacity Plus Legacy mode, configure the following

settings the TX Stations menu item of SmartPTT Radioserver Configurator:

1. Right click TX Stations, then click Add > Remote MOTOTRBO control station.

2. Specify the parameters of connection to the remote control station as it is described in the previous section.

3. If you need to create more than one connection to the remote control stations, repeat steps 1 to 2 for each

new remote control station.

Page 79: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

783. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3.3 Interaction with Mototrbo remote control stations inthe NAI Capacity Plus and NAI Linked Capacity Plushybrid modes

Radio network topologies and examples of SmartPTT dispatching systems for this radioserver configuration are

described in details in the "RG-1000e — Remote Gateway" user guide. See the following sections in the guide:

· "Example of system topology in the Capacity Plus trunking network with data transmission via the NAI protocol

(hybrid mode)", and

· "Example of system topology in the Linked Capacity Plus trunking network with data transmission via the NAI

protocol (hybrid mode)".

The parameters of the connection to the remote control stations in the NAI Capacity Plus and NAI Linked

Capacity Plus modes are configured in the corresponding sections in SmartPTT Radioserver Configurator. This

guide does not cover the common settings of the radio networks configuration. For more information about the

configuration of the NAI - Capacity Plus and NAI - Linked Capacity Plus systems see the "SmartPTT

Radioserver Configurator" software help file.

To add connection to the remote control stations in the NAI Capacity Plus and NAI Linked Capacity Plus modes,

configure the following settings in the NAI Systems section of SmartPTT Radioserver Configurator:

1. In the NAI - Capacity Plus or NAI - Linked Capacity Plus network general settings, select the Voice

transmission check box and select Control Stations in list (applicable to the SmartPTT PLUS systems). If

you use the SmartPTT Enterprise systems, skip this step.

Page 80: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

793. SmartPTT Radioserver settings

CPS RG-1000e User Guide

2. In the Slot menu item of the NAI - Capacity Plus or NAI - Linked Capacity Plus sections, right click

Control Stations, then click Add > Remote MOTOTRBO control station.

3. Specify the parameters of connection to the remote control station as it is described in the previous section.

Page 81: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

803. SmartPTT Radioserver settings

CPS RG-1000e User Guide

4. If you need to create more than one connection to the remote control stations, repeat steps 1 to 2 for each

new remote control station.

Page 82: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

813. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3.4 Interaction with non-Mototrbo remote controlstations (remote I\O control staition), for SmartPTT 9.3and above

To create the connection to the RG-1000e GATEWAY for interaction with non-Mototrbo control station (RG-1000e

I\O mode) you should configure the following settings in SmartPTT Radioserver Configurator:

1. Right click Control Stations in the setting tree of SmartPTT Radioserver Configurator.

2. Click Add > Remote I\O Control Station.

3. In the window that opens specify the parameters of the connection to the remote control station.

Page 83: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

823. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Active: Activates the connection to the remote control station. To disable the remote control station from the

connection list, clear the Active check box.

Name: Remote control station arbitrary name. This name will be shown on SmartPTT Dispatcher console.

Remote gateway IP address: Gateway network IP address. The IP address in this field must match the value

specified in the settings of the gateway IP channel for this remote control station. See in RG-1000e CPS, the

corresponding IP channel window in the Network section.

XCMP port: The gateway port. The XCMP port in this field must match the value specified in the corresponding

field in RG-1000e CPS. See the Port XCMP protocol field in the IP channel window of the Network section.

Serial number: Radio serial number. Just for your reference, for instance 1234567890.

Local interface: The local Ethernet interface used for connection to the RG-1000e GATEWAY.

Talkgroup name: Put talkgroup name. Just for your reference, for instance All Call.

TX Criteria: Determines when the radio is allowed to be transmitted. Always:the radio will always. Channel Free:

the radio will check for an idle channel prior to allowing a transmission.

TX Time-Out Timer, s: Continuous radio transmission timeout. After this time the transmission is interrupted.

Call Hangtime, ms: Virtual hangtime which is used for uniting calls into one. This was done to not overload the

event log with too many records of calls. During this hangtime the channel is not reserved, anyone can start

transmitting.

Set local ports: Local ports that can be used for connection to the RG-1000e GATEWAY, if the default ports of

the corresponding services are already in use. By default the system occupies local ports automatically, but you

can define them manually.

4. Add or edit the channels of the remote control station in the Control Station Channels window. These

settings allows remote switching between the control station channels and must match with the radio settings

in the remote non-Mototrbo control station.

Name: Channel alias visible to SmartPTT Dispatcher.

Channel: Channel sequence number.

: Selected channel will be set at the control station, when you start the radioserver.

Page 84: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

833. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Copy: Copies added channels of the remote control station to the clipboard. Paste: Pastes copied channels of

the remote control station from the clipboard.

Add: Adds a new channel. Remove: Deletes the channel from the list.

To edit channel name place the cursor on the corresponding field and make changes.

5. To select audio devices and set up VoIP parameters, click Audio in the setting tree of SmartPTT Radioserver

Configurator. At that, the Audio Settings window will open.

The Active check box activates transmission and receiving of the audio signals for the remote control station.

Codec: Outgoing audio stream compression method. The recommended value is CCITT u-Law.

Format: Sampling frequency of an outgoing audio stream and the RTP packet size. The recommended value is

8000 Hz, 20 ms, 64 (86) kbps.

7. If you need to create more than one connection to the remote control stations, repeat steps 1 to 6 for each

new remote control station.

Page 85: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

843. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3.5 Interaction with non-Mototrbo remote controlstations (using SmartPTT Call Emulation), for SmartPTT9.2 and earlier

To create the connection to the RG-1000e GATEWAY, that is pre-programmed to interact with non-Mototrbo

control stations, using SmartPTT Call Emulation feature, configure the following settings in SmartPTT Radioserver

Configurator:

1. Right click Control Stations in the setting tree of SmartPTT Radioserver Configurator.

2. Click Add > Remote MOTOTRBO control station.

Page 86: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

853. SmartPTT Radioserver settings

CPS RG-1000e User Guide

3. In the window that opens specify the parameters of the connection to the remote control station.

Active: Activates the connection to the remote control station. To disable the remote control station from the

connection list, clear the Active check box.

Name: Remote control station arbitrary name. This name will be shown on SmartPTT Dispatcher console.

Page 87: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

863. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Remote gateway IP address: Gateway network IP address. The IP address in this field must match the value

specified in the settings of the gateway IP channel for this remote control station. See in RG-1000e CPS, the

corresponding IP channel window in the Network section.

XCMP port: The gateway port. The XCMP port in this field must match the value specified in the corresponding

field in RG-1000e CPS. See the Port XCMP protocol field in the IP channel window of the Network section.

Local interface: The local Ethernet interface is used for connection to the RG-1000e GATEWAY.

Radio ID: Unique identifier of the remote control station. In the case when RG-1000e GATEWAY interacts with

non-Mototrbo control stations, using for call processing SmartPTT Call Emulation feature, Radio ID must match

corresponding ID in RG-1000e settings.

CAI Network: CAI network identifier. Set 12.

CAI Network for Groups: Group CAI network identifier. Set 225.

Boxes Transmit Data Only, Allow Telephone Interconnect, GPS, ARS, TMS, Telemetry Service, Set local

ports should be unchecked.

Analog Call Hangtime: Set 1000 ms.

4. Add or edit the channels of the remote control station in the Control Station Channels window. These

settings allows remote switching between the control station channels and must match with the non-Mototrbo

radio settings.

Page 88: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

873. SmartPTT Radioserver settings

CPS RG-1000e User Guide

Name: Channel alias visible to SmartPTT Dispatcher.

Zone: Serial number of a channel group. Use Zone 1.

Channel: Channel sequence number.

: Selected channel will be set at the control station, when you start the radioserver.

Copy: Copies added channels of the remote control station to the clipboard. Paste: Pastes copied channels of

the remote control station from the clipboard.

Add: Adds a new channel. Remove: Deletes the channel from the list.

To edit channel name, or channel number, place the cursor on the corresponding field and make changes.

5. In the Control Station Talkgroups window, add just one talkgroup, which the dispatcher(s) may use for

making outgoing calls via the remote non-Mototrbo control station.

To add a talkgroup, click Add.

Remove: Deletes the selected talkgroup.

Name: Talkgroup alias displayed by the control station.To edit talkgroup name or ID, set the cursor on the

corresponding field and make changes.

Page 89: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

883. SmartPTT Radioserver settings

CPS RG-1000e User Guide

ID: Talkgroup unique identifier used during communications. In the case when RG-1000e GATEWAY interacts

with non-Mototrbo control stations, using for call processing SmartPTT Call Emulation feature, the talkgroup

identifier must match corresponding ID in RG-1000e settings.

6. To select audio devices and set up VoIP parameters, click Audio in the setting tree of SmartPTT Radioserver

Configurator. At that, the Audio Settings window will open.

Page 90: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

893. SmartPTT Radioserver settings

CPS RG-1000e User Guide

The Active check box activates transmission and receiving of the audio signals for the remote control station.

Codec: Outgoing audio stream compression method. The recommended value is CCITT u-Law.

Format: Sampling frequency of an outgoing audio stream and the RTP packet size. The recommended value is

8000 Hz, 20 ms, 64 (86) kbps.

7. If you need to create more than one connection to the remote control stations, repeat steps 1 to 6 for each

new remote control station.

Page 91: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

904. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4. Radio 1(2) port configuration samples

Figures below show Radio 1(2) port setting for interaction RG-1000e with different donor radios. Hope it makes

RG-1000e implementation process easier and faster. Shown Radio 1(2) port settings may be considered as

recommended. At the same time settings may vary depends on a project technical requirements.

Page 92: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

914. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.1 Mototrbo, Radio 1(2) port settings

Page 93: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

924. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 94: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

934. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 95: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

944. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 96: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

954. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.2 APX\XTL, Radio 1(2) port setting, SmartPTT 9.3 andabove

Page 97: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

964. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-APX ver 0-1 and C-APX ver1-1 should be used.

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-APX ver 0-1 and C-APX ver 1-1 should be used.

Page 98: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

974. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 99: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

984. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 100: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

994. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 101: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1004. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.3 APX\XTL, Radio 1(2) port settings, SmartPTT 9.2and earlier

Page 102: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1014. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-APX ver 0-1 and C-APX ver1-1 should be used.

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-APX ver 0-1 and C-APX ver1-1 should be used.

Page 103: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1024. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 104: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1034. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 105: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1044. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 106: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1054. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.4 MTM, Radio 1(2) port settings, SmartPTT 9.3 or later

Page 107: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1064. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-MTM ver 0-1 and C-MTM ver1-1 should be used.

Page 108: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1074. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 109: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1084. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 110: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1094. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.5 MTM, Radio 1(2) port settings, SmartPTT 9.2 orearlier

Page 111: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1104. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Voltage control threshold level should be 9.5V for SmartPTT 9.4 and 0V for SmartPTT 9.3&9.2 For proper SmartPTT 9.4 operations radio connection cables C-MTM ver 0-1 and C-MTM ver1-1 should be used.

Page 112: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1114. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 113: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1124. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 114: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1134. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.6 SLR5500\XPR8300\XPR8400\XIRR8200, Radio 1(2)port settings, SmartPTT 9.3 or later

Page 115: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1144. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 116: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1154. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 117: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1164. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 118: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1174. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

4.7 SLR5500\XPR8300\XPR8400\XIRR8200, Radio 1(2)port settings, SmartPTT 9.2 or earlier

Page 119: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1184. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 120: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1194. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 121: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

1204. Radio 1(2) port configuration samples

CPS RG-1000e User Guide

Page 122: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

121Appendix I RG-1000e driver installation

CPS RG-1000e User Guide

Appendix I RG-1000e driver installation

To install RG-1000 driver perform the following actions:

1. Download from http://zadig.akeo.ie/ Zagid 2.4/2.3 softool.

2. Locate Zagid 2.4/2.3 to a desirable folder. Installation is not required.

3. Connect RG-1000e to PC USB port and turn-on RG-1000e.

4. Navigate to PC Control panel and open PC Device Manager. You may see Other devices - ATIS M-300.

Page 123: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

122Appendix I RG-1000e driver installation

CPS RG-1000e User Guide

5. Run Zagid and select target device ATIS M-300.

6. Check–on Edit box.

7. Delete ATIS M-300 and type RG-1000e.

Page 124: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

123Appendix I RG-1000e driver installation

CPS RG-1000e User Guide

8. Select target driver libusb-win32 (v1.2.6.0).

9. Click Install Driver.

10. If everything is ok you should see this pop-up message.

Page 125: Customer Programming Software RG-1000e (CPS RG-1000e) User ...support.smartptt.com/hc/en-us/article_attachments/360026136773/CPS_RG... · 192.168.200.1[51130]  192.168.100.1[30010]

124Appendix I RG-1000e driver installation

CPS RG-1000e User Guide

11. Open PC Device Manager. You may see RG-1000e device.