Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and...
Transcript of Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and...
Clinical solutions to meet the specific needs of your neonatal and pediatric ICU.
Custom IV Sets & Connectorsfor Neonatal and Pediatric Applications
> Custom IV Sets specifically designed for neonatal or pediatric applications.
> Closed IV administration.
> Choose from any of our needlefree connectors to best meet your needs.
The patented technology in our complete line of needlefree IV connectors has been
clinically proven to provide an effective barrier against bacterial transfer and colonization,1,2
helping you keep your most precious patients safer from infection.
Common features of the line include:
> A single clinical protocol used with all patient populations, minimizing clinical training and in-servicing.
> Highly efficient flushing ability, helping you to completely clear the connectors of blood and blood components.
> A mechanically and microbiologically closed system, providing a safe and effective microbial barrier.
> Needlefree connector technology that has been chosen by clinicians more than twice as often as any other.3
Our newest addition to the family: NanoClave®
The NanoClave low-profile neutral displacement needlefree connector is specifically
designed with a small size and minimal residual volume to help you keep your delicate
neonatal and pediatric patients safe from infection while
effectively managing their fluids.
> Effectively clears blood and blood residual with low flush volumes.4
> Does not require a change in clinical practice or technique.
> Saline flush option can eliminate the use of heparin.
> Minimal blood reflux in the catheter tip.
A Commitment to Neonatal and Pediatric Patient SafetyWe know that improving neonatal and pediatric patient safety is a priority. And we’re here to help.
NEW
NanoClave®
MicroClave®
MicroClave® Clear
Neutron®
Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific IV therapy needs?
Our custom IV set program allows facilities to maximize efficiencies by designing patient-ready sets, avoiding burdensome assembly of multiple sets and unnecessary storage of extra components.
Clinicians can choose from thousands of clinically-proven component options to design the perfect set to meet a specific need. Whether
consolidating existing sets or designing a new set from the ground up, we prove that customization does not have to cost more.
> Choice of standard IV administration or closed IV sets
> Choice of any of our needlefree neutral displacement connectors
> No long-term contracts for custom sets with standard components
> Non-sterile samples in one week, sterile samples in two weeks
> No minimum orders
> Quotes in 72 hours
Each connector is indicated for
use with a saline flush protocol.
F L U J OF L O W
C L E A R S ID E
F L U J OF L O W
C L E A R S ID E
F L U J OF L O W
C L E A R S ID E
F L U JO
F L OW
C L E A R S ID E
FLUJOFLOW
FLUJO
FLOW
Closed IV Administration Sets
Item Length (in.) Priming volume (mL) Case Qty
B33303 127 9.30 50
Description: 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Anti-Siphon Valve, Smallbore Quadfuse Ext Set with MicroClave®, 4 Clamps (Blue, 2 Red, White), Tubing Clip, Rotating Luer, Non-DEHP Tubing
Description: 108” (274 cm) 10 Drop Primary Set with 2 BCV-Clave®, Clave® Clear, Remv 2 Gang Clave® Stopcock, Clave® Stopcock, NanoClave® T-Connector, 2 Ext, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
A1010 108 13.30 25
Description 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Quadfuse Ext Set with 3 MicroClave Clear® (Yellow,Green Rings), Anti-Siphon Valve, 3-0.2 Micron Filters, 1.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing
Description 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Trifuse Ext Set with 2 MicroClave Clear® (Yellow, Green Rings), Anti-Siphon Valve, 3 Clamps, 2-0.2 Micron Filter, 1.2 Micron Filter, Rotating Luer, Non-DEHP Tubing
Description 128” (325 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Bifuse Ext Set with MicroClave Clear® (Green Ring), Anti-Siphon Valve, 0.2 Micron Filter, Rotating Luer, Non-DEHP Tubing
Description: 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Quadfuse Ext Set with 3 MicroClave® Clear (Yellow, Green Rings), Anti-Siphon Valve, 2-0.2 Micron Filter, 1.2 Micron Filter, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33334 127 12.20 50
Item Length (in.) Priming volume (mL) Case Qty
MC33333 127 11.80 50
Item Length (in.) Priming volume (mL) Case Qty
MC33332 128 11.40 50
Item Length (in.) Priming volume (mL) Case Qty
MC33331 127 11.85 50
Extension Sets
Description 8” (20 cm) Smallbore Ext Set with 2 NanoClave®, Clamp, Rotating Luer, Non-DEHP Tubing
Description 7” (18 cm) Smallbore Ext Set with MicroClave® Clear, Clamp, Rotating Luer, Non-DEHP Tubing
Description 4.5” (11 cm) Smallbore Ext Set with MicroClave® Clear, Clamp, Rotating Luer, Non-DEHP Tubing
Description 4” (10 cm) Smallbore Ext Set with NanoClave®, Clamp, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
A1061 8 0.34 50
Item Length (in.) Priming volume (mL) Case Qty
MC3302 7 0.24 50
Item Length (in.) Priming volume (mL) Case Qty
MC33191 4.5 0.18 50
Item Length (in.) Priming volume (mL) Case Qty
A1063 4 0.18 50
0,2 µm
OFF
FLUJO
FLOW
Extension Sets (Cont)
Bifuse Extension Sets
Item Length (in.) Priming volume (mL) Case Qty
B33357 72 1.10 50
Description 72” (183 cm) Smallbore Ext Set with 4-Way Stopcock, 2 MicroClave®, Anti-Siphon Valve, Clamp, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33129 4 0.24 50
Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear, 2 Clamps, Rotating Luer, Non-DEHP Tubing
Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 NanoClave®, 2 Clamps, Rotating Luer, Non-DEHP Tubing
Description 7” (18 cm) Smallbore Ext Set with MicroClave® Clear (Green Ring), 0.2 Micron Filter, Clamp, Rotating Luer, Non DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
A1064 4 0.29 50
Item Length (in.) Priming volume (mL) Case Qty
A1014 8 0.51 50
Description 8” (20 cm) Smallbore Ext Set with MicroClave® Clear, 0.2 Micron Filter, NanoClave® T-Connector, Clamp, Rotating Luer, Non-DEHP Tubing
Description 33” (84 cm) Ext Set with 2 Clave® Clear, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33386 33 4.40 50
Item Length (in.) Priming volume (mL) Case Qty
MC33335 7 0.41 50
Description 7’’ (18 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear, Check Valve, 2 Clamps, Rotating Luer, Non-DEHP Tubing
Description 9” (23 cm) Smallbore Bifuse Ext Set with 3 NanoClave®, 3 Clamps, 0.2 Micron Filter, Rotating Luer, Non-DEHP Tubing
Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear (Green, Yellow Rings), 2 Clamps, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33576 7 0.49 50
Item Length (in.) Priming volume (mL) Case Qty
A1062 9 0.70 50
Item Length (in.) Priming volume (mL) Case Qty
MC33375 4 0.24 50
Item Length (in.) Priming volume (mL) Case Qty
A1065 4 0.47 50
Description 4” (10 cm) Smallbore Trifuse Ext Set with 3 NanoClave®, 3 Clamps, Rotating Luer, Non-DEHP Tubing
Trifuse Extension Sets
Item Length (in.) Priming volume (mL) Case Qty
MC33098 4 0.40 50
Description 4” (10 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 3 Clamps, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
A1013 10 2.9 50
Description 10” (25 cm) Trifuse Ext Set with 3 MicroClave® Clear, Tri-Connector, NanoClave® T-Connector, 4 Clamps (Red, White, Blue), Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33192 6 0.39 50
Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Red, Green Ring), Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33377 5.5 .21 50
Description 5.5” (14 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Glow, Green, Yellow Rings), 4 Clamps, Rotating Luer, Non-DEHP Tubing
Description 7” (18 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 2 Check Valve, 3 Clamps, Rotating Luer, Non-DEHP Tubing
Description 7” (18 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Red, Glow Rings), 0.2 Micron Filter, 3 Clamps (Red, White, Blue), Rotating Luer, Non-DEHP Tubing
Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, Check Valve, 3 Clamps, Rotating Luer, Non-DEHP Tubing
Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 3 Clamps, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
MC33577 7 0.80 50
Item Length (in.) Priming volume (mL) Case Qty
MC33193 7 0.70 50
Item Length (in.) Priming volume (mL) Case Qty
MC33575 6 0.62 50
Item Length (in.) Priming volume (mL) Case Qty
MC33194 6 0.48 50
Item Length (in.) Priming volume (mL) Case Qty
MC33340 6 1.40 50
Description 6” (15 cm) Smallbore Quadfuse Ext Set with 4 MicroClave® Clear (Yellow,3 Green Rings), 3-0.2 Micron Filters, 1.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing
Quadfuse Extension Sets
Item Length (in.) Priming volume (mL) Case Qty
A1066 4 0.57 50
Description 4” (10 cm) Smallbore Quadfuse Ext Set with 4 NanoClave®, 4 Clamps, Rotating Luer, Non-DEHP Tubing
Item Length (in.) Priming volume (mL) Case Qty
A1067 9 1.00 50
Description 9” (23 cm) Smallbore Quadfuse Ext Set with 5 NanoClave®, 0.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing
FLUJOFLOW
FLUJO
FLOW
Want to create a custom set to meet a specific clinical need? Contact your local ICU Medical representative.
800.824.7890 | www.icumed.com©2013 ICU Medical Inc. | M1-1370 Rev. 03
“ Following the switch to MicroClave connectors and the implementation of a new closed IV system and smart infusion devices, infection rates were reduced by 60 percent and medication errors decreased by 54 percent. Much of this error reduction was ascribed to the use of the closed system, which ensures that nurses deliver intermittent IV medications via a single, consistent method.”Tanner J, Developing a Closed, Intravenous Medication System for a Neonatal Intensive Care Unit. Neonatal Intensive Care Journal, July–August 2012. (Set featured above.)
> Optimize and tightly control fluid volumes
> Standardize your process
> Help foster nursing compliance
The right closed IV administration system can provide the clinical benefits of continuous and scheduled medication delivery, while limiting your administration technique to a single delivery method with the fewest connections possible.
Learn how custom closed IV administration systems can improve patient care and reduce infection rates in neonatal and pediatric ICUs.
1 Ryder M, James G, Pulchini E, Bickle L, Parker A. Differences in bacterial transfer and fluid path colonization through needlefree connector-catheter systems in vitro. Presented at the Infusion Nursing Society Meeting, May 2011. 2 Moore C, RN, MBA, CIC. Maintained Low Rate of Catheter-Related Bloodstream Infections (CR-BSIs) After Discontinuation of a Luer Access Device (LAD) at an Academic Medical Center. Poster presented at the annual Association for Professionals in Infection Control and Epidemiology (APIC) Conference 2010, Abstract 4-028. 3 Global Healthcare Exchange(GHX) Market Intelligence data. Connectors, Needleless, Parenterals, [92-100]. Q1-Q4 2012. Includes stand-alone needlefree connectors and ancillary direct access devices (two-piece, hemodialysis, non-swab-able, and non-patient contact connectors excluded). 4Breznock E M, DVM, PhD, Diplomate ACVS, Sylvia C J, DVM, MS., BioSurg, Inc. The in vivo evaluation of the flushing efficiency of different designs of clear needlefree connectors, March 2011.