Download C.A.D models or contact us on COSSIGA.COM Page 1 CURVED CC5 CC5 RF6 CC5 RF9 CC5 RF12 CC5 RF15 CC5 HT6 CC5 HT9 CC5 HT12 RF HT Deck forced refrigeration Sliding doors front and rear Double glazed Two adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Integral condensor Self evaporating Solid glass front - optional Sliding doors front and rear Single glazed Three adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Solid glass front - optional

Transcript of CURVED CC5 RF - cossiga.com · Page 1 Download C.A.D models or contact us on COSSIGA.COM CURVED CC5...

Download C.A.D models or contact us on COSSIGA.COMPage 1

CURVED CC5

CC5 RF6CC5 RF9CC5 RF12CC5 RF15

CC5 HT6CC5 HT9CC5 HT12

RF

HT

Deck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional

Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optional

Download C.A.D models or contact us on COSSIGA.COMPage 2

CURVED CC5

ABSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceiling

CC5 AB6CC5 AB9CC5 AB12

BMSliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional

CC5 BM6CC5 BM9CC5 BM12

Download C.A.D models or contact us on COSSIGA.COMPage 3

CABInET DIMEnSIOnS & SPECIFICATIOnS

CURVED CC5 Dimensions

MODEL CABInET SHELVInG SHELVInG SIzES FREQUEnCY REFRIGERAnT TOTALFOOD

OPERATInG CURREnT

COnnECTIOn VOLTAGE PACkED FOR SHIPPInG

LEnGTH [MM]

DEPTH[MM]

HEIGHT[MM]

CUTOUTS

TOP 2nD 3RD BASE 100MMUnITS

LEnGTH [MM]

DEPTH[MM]

HEIGHT[MM]

WEIGHT[kG]

CUBE

CC5RF6 600 650 925 615x620 2 + BASE 490 x 325 490 x 405 545 x 415 134A 55 3.2 AMP 10AMP 3 PIn PLUG 240V 700 730 1400 126 0.71

CC5RF9 900 650 925 915x620 2 + BASE 790 x 325 790 x 405 845 x 415 134A 84 3.7 AMP 10AMP 3 PIn PLUG 240V 1000 730 1445 154 1.05

CC5RF12 1200 650 925 1215x620 2 + BASE 1090 x 325

1090 x 405 1145 x 415 134A 121 4.6 AMP 10AMP 3 PIn PLUG 240V 1300 730 1445 204 1.37

CC5RF15 1500 650 925 1515x620 2 + BASE 1390 x 325

1390 x 405 1445 x 415 134A 154 5.0 AMP 10AMP 3 PIn PLUG 240V 1600 730 1445 221 1.68

CC5HT6 600 650 925 615x620 3 + BASE 490 x 325 490 x 365 490 x 395 545 x 415 n/A 75 4.6 AMP 10AMP 3 PIn PLUG 240V 700 730 1100 83 0.56

CC5HT9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 n/A 120 6.2 AMP 10AMP 3 PIn PLUG 240V 1000 730 1100 106 0.80

CC5HT12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 n/A 154 7.7 AMP 10AMP 3 PIn PLUG 240V 1300 730 1100 130 1.04

CC5AB6 600 650 925 615x620 3 + BASE 490 x 325 490 x 365 490 x 395 545 x 415 n/A 55 0.2 AMP 10AMP 3 PIn PLUG 240V 700 730 1100 83 0.56

CC5AB9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 n/A 84 0.3 AMP 10AMP 3 PIn PLUG 240V 1000 730 1100 106 0.80

CC5AB12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 n/A 121 0.4 AMP 10AMP 3 PIn PLUG 240V 1300 730 1100 130 1.04

CC5BM9 900 650 925 915x620 4 x 1/2 - 65mm Gastro Pans LEAD OnLY n/A 154 9.9 AMP 15 AMP SUPPLY 240V 1000 730 1100 87 0.80

CC5BM12 1200 650 925 1215x620 6 x 1/2 - 65mm Gastro Pans LEAD OnLY n/A 11 AMP 15 AMP SUPPLY 240V 1300 730 1100 117 1.04

CC5BM15 1500 650 925 1515x620 8 x 1/2 - 65mm Gastro Pans LEAD OnLY n/A 15 AMP 20 AMP SUPPLY 240V 1600 730 1100 146 1.28

Download C.A.D models or contact us on COSSIGA.COMPage 4

REMOTE InSTALLATIOn AnD SERVICES

Units are self evaporating to a receptacle in the condensor unitIn areas of high humidity units should be plumbed directly to a waste.

Plumbed Receptacle

- Maximum 150mm above finished floor level

- Drainage to building waste

- Building waste by client

- Receptacle placed under unit

- Dispose of water daily

3/8” pipe max run 1500 mm

condensate drainto four litre container

Vertical pipe runs are not recommended

Pipe runs over 150mm : - Expansion valve will need to be fitted - Correctly sized condensing unit fitted - Correct pipe size determined

Download C.A.D models or contact us on COSSIGA.COMPage 5

JOInERY AIR FLOW COnSIDERATIOnS

Closed rear. Front vented

Intake and extract vents.Min 400mm x 400mm openarea.

Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face

200mm clearspace

200mm clearspace

350 mm

260

mm

varies

vari

es

Hole Cut to meet condenser face

Open at rear

Closed front

Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face

200mm clearspace

200mm clearspace

Front Vented Rear Vented

Download C.A.D models or contact us on COSSIGA.COMPage 6

ExTRACTIOn FAn

Extract hot air from box joinery

Fan and power cable supplied, screw fixed to joinery

Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required

Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case

ExTRACTIOn FAn

Download C.A.D models or contact us on COSSIGA.COMPage 7

DROP In COUnTER TOP CUT OUT DETAILS

Cut out 585 mm

Cut out 525 mmmin 75 mm

min 75 mm

Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)

RF6 Cut out 525 mmRF6 Cut out 525 mm

ALLO

W 4

00 m

m

Open at rear.

150 mm

Cut out see table

Supplied 5mm PVCwedge strip to sidesfor drop-in unit

Cut out 620 mmmin 20 mm

min 20 mm

Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)

ALLO

W 4

00 m

m

Open at rear.

Remove feet for alldrop-in installations

Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required

Download C.A.D models or contact us on COSSIGA.COMPage 8

JOInERY TO REAR WALL WITH VEnT

Horizontal vent in cabinet top for hot air extract

Electric biscuit fans can also be fitted to provide mechanical extract

Ambient air ducted in to compressor face through air plenum space

Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face

Allow access for cleaning, servicing and waste evaporator water removal

Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit

Vent must be at least 100mm deep and as wide as unit

Download C.A.D models or contact us on COSSIGA.COMPage 9

AIRFLOW AnD PLACEMEnT GUIDE LInES

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW

NO AIR FLOW

AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors

Locations to avoid are :

Close to shop front exterior In an outside location In direct sunlight In a high cross wind area near any source producing excessive heat

Download C.A.D models or contact us on COSSIGA.COMPage 10

Ventilation Grill

CC5 ACCESSORIES

Top Mounted Controller Panel

Price Tabs

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelSold individually

Stainless SteelDrop into counter tray raceSolid individually

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

450

mm

450 mm

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

Download C.A.D models or contact us on COSSIGA.COMPage 11

MIRROR FILM

Applied to the inside glass rear doors

Suitable for heated and chilledunits

Mirror film adhered to inside of rear door glass

Mirror film adhered to inside of rear door glass

FREE STAnDInG UnITS BEnCHTOP UnITS

Blocks work areasbehind units

Add depth toyour displays

Download C.A.D models or contact us on COSSIGA.COMPage 12

THERMAL BARRIERS

BEnCHTOP DROP In

BEnCHTOP DROP In

BEnCHTOP

BEnCHTOP

CC5 -TBDI

STG -TBDI

CC5 -TBC

STG -TBC

Thermal spacer barriers

Provides thermal separation between hot and cold units with minimum spacing

Provides a continuous look

20mm Clear polycarbonate with polished edges

Download C.A.D models or contact us on COSSIGA.COMPage 13

Pie Trays

PIE TRAYS PIE TRAYS

MODEL CODE QUAnTITY 1ST SHELFDEPTH

2nD SHELFDEPTH

3RD SHELFDEPTH

TOTAL SHELFWIDTH

CC5HT6 AA16015 4 Per Shelf 325MM 365MM 395MM 12 Trays 120MM

CC5HT9 AA16016 6 Per Shelf 325MM 365MM 395MM 18 Trays 130MM

CC5HT12 AA16017 9 Per Shelf 325MM 365MM 395MM 27 Trays 120MM

Gastro norm System

GASTRO nORM

MODEL CODE QUAnTITY DIMEnSIOnS PAn DEPTH

CC5HT6 F92-315 2 Per Unit 265MM x 325MM PAnS AnD FRAME 65MM

CC5HT9 F92-316 3 Per Unit 265MM x 325MM PAnS AnD FRAME 65MM

CC5HT12 F92-317 4 Per Unit 265MM x 325MM PAnS AnD FRAME 65MM

HEATED UnIT ACCESSORIES

Stainless Steel ConstructionPlaced on shelves for heated food items

Stainless Steel ConstructionAngled display view