568 List prices subject to change. Contact your local Johnstone Supply for competitive prices. HVAC EQUIPMENT Boilers Peerless Boiler OEM Replacement Parts All of the core replacement parts and more for Peerless Boilers are available at your Local Johnstone Supply. Contact us for model to part cross reference and solve your no heat and warranty service calls — fast and efficiently with the exact OEM replacement part Bimini Gas Fired Hot Water Boilers Condensing, High Efficiency, Direct Spark 3/4" boiler drain Combination temperature/pressure gauge A.S.M.E. relief valve (30 PSI) Stainless steel burner Variable-speed blower assembly Differential pressure switch for proving air flow Probe style LWCO Micro processor control module L97-827 uses 60/100mm concentric vent L99-401 through L99-403, L90-545 and L90-546 are commercial boilers L99-401 through L99-403, L90-545 and L90-546 meet Z21.3 requirements and approved for closet installation L90-547 through L90-554 has CPVC/PVC venting BWC070 through BWC120 and BWC151 models are wall mounted models with concentric venting or CPVC/PVC venting options BWC150 and BWC225 are floor standing models Fig. Order # Mfg. # Gas Type Sections AFUE BtuH Input DOE Htg. Capacity BtuH IBR Rating BtuH Flue Diam. Width Height Depth Wt. Lbs. Energy Star A L98-262 BWC070 NG Mono Block 95.4 70,000 63,000 55,000 17-7/8" 31-1/2" 17" 143 Y A L98-263 BWC090 NG Mono Block 94.5 90,000 80,000 70,000 17-7/8" 31-1/2" 17" 143 Y A L97-827 BWC120 NG Mono Block 95.2 120,000 107,000 93,000 17-7/8" 31-1/2" 17" 149 Y A L99-459 BWC151 NG Mono Block 95.2 150,000 135,000 117,000 23-3/8" 43-3/4" 22-1/4" 168 Y B L97-828 BWC150 NG 3 93.1 150,000 135,000 117,000 3" 23-3/8" 43-3/4" 22-1/4" 285 Y B L97-829 BWC225 NG 4 94.2 225,000 202,000 176,000 4" 27" 43-3/4" 22-1/4" 323 Y C L99-401 BWC300 NG 5 95.7 300,000 230,000 4" 33-3/8" 24" 51-1/2" 438 C L99-402 BWC399 NG 7 96.1 399,000 304,000 5" 40-1/8" 24" 51-1/2" 534 C L99-403 BWC425 NG 7 96.1 425,000 320,000 5" 40-1/8" 24" 51-1/2" 535 A L90-539 BWC070ELST1PSU LP Mono Block 95.4 70,000 63,000 55,000 17-7/8" 31-1/2" 17" 143 Y A L90-540 BWC090ELST1PSU LP Mono Block 94.5 90,000 80,000 70,000 17-7/8" 31-1/2" 17" 143 Y A L90-541 BWC120ELST1PSU LP Mono Block 95.2 120,000 107,000 93,000 17-7/8" 31-1/2" 17" 149 Y A L90-543 BWC151ELST1PSU LP Mono Block 95.2 150,000 135,000 117,000 23-3/8" 43-3/4" 22-1/4" 168 Y B L90-542 BWC150ELST1PSU LP 3 93.1 150,000 135,000 117,000 3" 23-3/8" 43-3/4" 22-1/4" 285 Y B L90-544 BWC225ELST1PSU LP 4 94.2 225,000 202,000 176,000 4" 27" 43-3/4" 22-1/4" 323 Y C L90-545 BWC300ELST1PSU LP 5 95.7 300,000 230,000 4" 33-3/8" 24" 51-1/2" 438 C L90-546 BWC425ELST1PSU LP 7 96.1 425,000 320,000 5" 40-1/8" 24" 51-1/2" 535 A L90-547 BWC070ENVT1PSU NG Mono Block 95.4 70,000 63,000 55,000 17-7/8" 31-1/2" 17" 143 Y A L90-548 BWC070ELVT1PSU LP Mono Block 95.4 70,000 63,000 55,000 17-7/8" 31-1/2" 17" 143 Y A L90-549 BWC090ENVT1PSU NG Mono Block 94.5 90,000 80,000 70,000 17-7/8" 31-1/2" 17" 143 Y A L90-550 BWC090ELVT1PSU LP Mono Block 94.5 90,000 80,000 70,000 17-7/8" 31-1/2" 17" 143 Y A L90-551 BWC120ENVT1PSU NG Mono Block 95.2 120,000 107,000 93,000 17-7/8" 31-1/2" 17" 149 Y A L90-552 BWC120ELVT1PSU LP Mono Block 95.2 120,000 107,000 93,000 17-7/8" 31-1/2" 17" 149 Y A L90-553 BWC151ENVT1PSU NG Mono Block 95.2 150,000 135,000 117,000 23-3/8" 43-3/4" 22-1/4" 168 Y A L90-554 BWC151ELVT1PSU LP Mono Block 95.2 150,000 135,000 117,000 23-3/8" 43-3/4" 22-1/4" 168 Y A B C

Transcript of Crown Catalog Pages

Page 1: Crown Catalog Pages

568 List prices subject to change. Contact your local Johnstone Supply for competitive prices.

HVAC EQUIPMENTBoilers

Peerless Boiler OEM Replacement Parts All of the core replacement parts and more for Peerless Boilers are available at your Local Johnstone Supply. Contact us for model to part

cross reference and solve your no heat and warranty service calls — fast and efficiently with the exact OEM replacement part

Bimini Gas Fired Hot Water Boilers Condensing, High Efficiency, Direct Spark•3/4" boiler drain •Combination temperature/pressure gauge •A.S.M.E. relief valve (30 PSI) •Stainless steel burner •Variable-speed blower assembly •Differential pressure switch for proving

air flow •Probe style LWCO •Micro processor control module •L97-827 uses 60/100mm concentric vent •L99-401 through L99-403, L90-545 and

L90-546 are commercial boilers

•L99-401 through L99-403, L90-545 and L90-546 meet Z21.3 requirements and approved for closet installation

•L90-547 through L90-554 has CPVC/PVC venting

•BWC070 through BWC120 and BWC151 models are wall mounted models with concentric venting or CPVC/PVC venting options

•BWC150 and BWC225 are floor standing models

Fig. Order # Mfg. # Gas Type Sections AFUE BtuH Input

DOE Htg. Capacity BtuH

IBR Rating BtuH

Flue Diam. Width Height Depth Wt. Lbs. Energy Star

A L98-262 BWC070 NG Mono Block 95.4 70,000 63,000 55,000 — 17-7/8" 31-1/2" 17" 143 YA L98-263 BWC090 NG Mono Block 94.5 90,000 80,000 70,000 — 17-7/8" 31-1/2" 17" 143 YA L97-827 BWC120 NG Mono Block 95.2 120,000 107,000 93,000 — 17-7/8" 31-1/2" 17" 149 YA L99-459 BWC151 NG Mono Block 95.2 150,000 135,000 117,000 — 23-3/8" 43-3/4" 22-1/4" 168 YB L97-828 BWC150 NG 3 93.1 150,000 135,000 117,000 3" 23-3/8" 43-3/4" 22-1/4" 285 YB L97-829 BWC225 NG 4 94.2 225,000 202,000 176,000 4" 27" 43-3/4" 22-1/4" 323 YC L99-401 BWC300 NG 5 95.7 300,000 — 230,000 4" 33-3/8" 24" 51-1/2" 438 —C L99-402 BWC399 NG 7 96.1 399,000 — 304,000 5" 40-1/8" 24" 51-1/2" 534 —C L99-403 BWC425 NG 7 96.1 425,000 — 320,000 5" 40-1/8" 24" 51-1/2" 535 —A L90-539 BWC070ELST1PSU LP Mono Block 95.4 70,000 63,000 55,000 — 17-7/8" 31-1/2" 17" 143 YA L90-540 BWC090ELST1PSU LP Mono Block 94.5 90,000 80,000 70,000 — 17-7/8" 31-1/2" 17" 143 YA L90-541 BWC120ELST1PSU LP Mono Block 95.2 120,000 107,000 93,000 — 17-7/8" 31-1/2" 17" 149 YA L90-543 BWC151ELST1PSU LP Mono Block 95.2 150,000 135,000 117,000 — 23-3/8" 43-3/4" 22-1/4" 168 YB L90-542 BWC150ELST1PSU LP 3 93.1 150,000 135,000 117,000 3" 23-3/8" 43-3/4" 22-1/4" 285 YB L90-544 BWC225ELST1PSU LP 4 94.2 225,000 202,000 176,000 4" 27" 43-3/4" 22-1/4" 323 YC L90-545 BWC300ELST1PSU LP 5 95.7 300,000 — 230,000 4" 33-3/8" 24" 51-1/2" 438 —C L90-546 BWC425ELST1PSU LP 7 96.1 425,000 — 320,000 5" 40-1/8" 24" 51-1/2" 535 —A L90-547 BWC070ENVT1PSU NG Mono Block 95.4 70,000 63,000 55,000 — 17-7/8" 31-1/2" 17" 143 YA L90-548 BWC070ELVT1PSU LP Mono Block 95.4 70,000 63,000 55,000 — 17-7/8" 31-1/2" 17" 143 YA L90-549 BWC090ENVT1PSU NG Mono Block 94.5 90,000 80,000 70,000 — 17-7/8" 31-1/2" 17" 143 YA L90-550 BWC090ELVT1PSU LP Mono Block 94.5 90,000 80,000 70,000 — 17-7/8" 31-1/2" 17" 143 YA L90-551 BWC120ENVT1PSU NG Mono Block 95.2 120,000 107,000 93,000 — 17-7/8" 31-1/2" 17" 149 YA L90-552 BWC120ELVT1PSU LP Mono Block 95.2 120,000 107,000 93,000 — 17-7/8" 31-1/2" 17" 149 YA L90-553 BWC151ENVT1PSU NG Mono Block 95.2 150,000 135,000 117,000 — 23-3/8" 43-3/4" 22-1/4" 168 YA L90-554 BWC151ELVT1PSU LP Mono Block 95.2 150,000 135,000 117,000 — 23-3/8" 43-3/4" 22-1/4" 168 Y

A B

C

Page 2: Crown Catalog Pages

569Large local inventories. More products online at johnstonesupply.com

HVAC EQUIPMENTBoilers

Concentric Vent Components for BWC Series •Adapter kit L44-618 is required for

concentric venting with model BWC150 •Adapter kit L44-619 is required for

concentric venting with model BWC 225

Order # Mfg. # Description Wt. Lbs.L44-618 230550 BWC150 Vent Adapter Concentric Adapter Kit 8.10L44-619 230555 BWC225 Vent Adapter Concentric Adapter Kit 12.35L44-620 230507 60/100 90° Elbow 1.75L44-621 230508 60/100 45° Elbow 1.50L44-622 230526 80/125 45° Elbow 1.75L44-623 230527 80/125 90° Elbow 2.50L44-624 230537 125mm Locking Band 1.00L44-625 230565 100/150 45° Elbow 2.00L44-626 230566 100/150 90° Elbow 2.30L80-306 230506 60/100 Straight 500mm Long (19-1/2") 3.00L80-307 230515 80/125 Straight 1,000mm Long (39") 6.25L80-308 230517 80/125 Straight 500mm Long (19-1/2") 3.50L80-309 230525 80/125 Straight Adjustable, Telescoping 3.75L80-310 230531 80/125 Horizontal Terminal 6.15L80-311 230560 100/150 Straight 500mm Long (19-1/2") 3.80L80-312 230564 100/150 Straight Adjustable, Telescoping 3.60L99-229 230504 60/100 Straight 2,000mm Long (78') 10.50L99-230 230505 60/100 Straight 1,000mm Long (39") 5.50

Order # Mfg. # Description Wt. Lbs.L99-231 230518 80/125 Straight 1,000mm Long (39") 6.25L99-232 230519 80/125 Straight 2,000mm Long (78') 12.25L99-233 230532 80/125 Vertical Terminal 11.25L99-234 230561 100/150 Straight 1,000mm Long (39") 6.50L99-235 230562 100/150 Straight 1,000mm Long (39") 6.50L99-236 230563 100/150 Straight 2,000mm Long (78') 12.00L99-237 230569 100/150 Horizontal Terminal 6.60L90-081 230595 BWC070/090/120/151 Concentric to CPVC/PVC

Field Conversion Vent Kit14.00

L90-082 230585 CPVC/PVC to 60/100mm Concentric Field Conver-sion Vent Kit

7.00

L90-083 230586 CPVC/PVC to 80/125mm Concentric Field Conver-sion Vent Kit

9.00

L90-084 230511 BWC Stainless Steel Horizontal Vent Terminal 15.00L90-085 230596 BWC150 CPVC/PVC Vent Kit 16.00L45-090 230597 BWC225 CPVC/PVC Vent Kit 1.00L90-086 230510 BWC 070/090/120 Adapter for Venting Stainless

Steel15.00

Maui Gas Fired Hot Water Boilers Wall Mounted, Sealed Combustion, Direct Vent•85% AFUE •ASME copper primary heat exchange • Integral plate heat exchanger and 3-way

valve for domestic hot water •Factory installed circular, expansion tank and

near boiling piping •Built-in bypass for flow through heat

exchanger

•LED provide diagnostic information •Combi models L99-245 and L99 246 have a

domestic hot water output of 2.67 gal./min. with a 77°F rise and 2.25 gal./min. with a 90°F rise

•L99-247 and L99-248 are heat only models •Concentric polypropylene venting system

Order # Mfg. # Gas Type AFUE BtuH InputDOE Htg. Capacity BtuH IBR Rating BtuH Width Height Depth Wt. Lbs.

L99-245 MWC116ENT NG 85 116,000 102,000 89,000 15-3/4" 41-1/8" 13-5/8" 110L99-246 MWC116ELT LP 85 116,000 102,000 89,000 15-3/4" 41-1/8" 13-5/8" 110L99-247 MWC116ENL NG 85 116,000 102,000 89,000 15-3/4" 41-1/8" 13-5/8" 110L99-248 MWC116ELL LP 85 116,000 102,000 89,000 15-3/4" 41-1/8" 13-5/8" 110

Aruba 3 Gas Fired Hot Water Boilers Atmospheric, Chimney Vent•Approved for installation on non-carpeted

combustible floors •Cast iron heat exchanger •Built-in draft diverter — category 1 venting •Motorized vent damper •Supply tapping located off top of boiler for

easier supply piping •1-1/4" high performance circulator •Stainless steel burners •Combination high limit/circulator relay control •Aquastat mounted directly into heat

exchanger

•Spill switch detects venting problems •ASME relief valve set at 30 PSI •Natural gas (LP gas available at participating

locations) •For altitudes above 2,000', ratings should be

reduced at rate of 4% for each 1,000' above sea level

•Boiler must be ordered for proper elevation above sea level when being installed at altitudes above 2,000

Order # Mfg. # AFUE BtuH InputDOE Htg. Capacity BtuH IBR Rating BtuH Flue Diam. Width Height Depth Wt. Lbs.

Standing Pilot ModelsL96-582 AWI061SNST1PSU 80.0% 61,000 50,000 43,000 4" 11-3/4" 32-1/4" 28" 267L96-583 AWI095SNST1PSU 80.1% 95,000 78,000 68,000 5" 15" 32-1/4" 28" 317L96-584 AWI128SNST1PSU 80.2% 128,000 105,000 91,000 6" 18-1/4" 32-1/4" 28" 367L96-585 AWI162SNST1PSU 80.3% 162,000 132,000 115,000 6" 21-1/2" 32-1/4" 28" 417Electronic Ignition ModelsL97-258 AWI061ENST1PSU 80.00% 61,000 50,000 43,000 4" 11-3/4" 32-1/4" 28" 267L97-259 AWI095ENST1PSU 80.10% 95,000 78,000 68,000 5" 15" 32-1/4" 28" 317L97-260 AWI128ENST1PSU 80.20% 128,000 105,000 91,000 6" 18-1/4" 32-1/4" 28" 367L97-261 AWI162ENST1PSU 80.30% 162,000 132,000 115,000 6" 21-1/2" 32-1/4" 28" 417

Page 3: Crown Catalog Pages

570 List prices subject to change. Contact your local Johnstone Supply for competitive prices.

HVAC EQUIPMENTBoilers

Cabo 2 Gas Fired Hot Water Boilers CWD Series, Sealed Combustion, Direct Spark Ignition, 85% AFUE•Approved for installation on non-carpeted

combustible floors • Ideal for tightly built and well insulated new

homes and houses without chimneys •Cast iron wet-leg heat exchanger •Direct horizontal venting or vertical venting

options to suit most locations — category III venting; see intallation instructions

•Powered intake and venting •System Controller provides two zones

•Plug-in outdoor temperature rest control •Self diagnostics with LED indicators •Pressure switch •Electronic ignition and step opening gas

valve •Stainless steel burners •Altitudes above 2,000' ratings should be

reduced at a rate of 4% for each 1,000' above sea level

Order # Mfg. # Sections AFUE BtuH InputDOE Htg. Capacity BtuH

IBR Rating BtuH Flue Diam. Width Height Depth Wt. Lbs.

L97-266 CWD-060 3 85.1 60,000 51,000 45,000 3" 16-1/8" 36-5/8" 22-1/8" 280L97-267 CWD-083 4 85.1 82,500 71,000 61,000 3" 19-3/4" 36-5/8" 22-1/8" 315L97-268 CWD-110 5 85.2 110,000 94,000 82,000 3" 23-3/8" 36-5/8" 22-1/8" 350L97-269 CWD-138 6 85.2 137,500 118,000 102,000 3" 27" 36-5/8" 22-1/8" 385L97-270 CWD-165 7 85.2 165,000 142,000 123,000 3" or 4" 30-5/8" 36-5/8" 22-1/8" 420L97-271 CWD-193 8 85.2 192,500 165,000 144,000 3" or 4" 34-1/8" 36-5/8" 22-1/8" 475L97-272 CWD-220 9 85.2 220,000 189,000 164,000 3" or 4" 32-3/4" 36-5/8" 22-1/8" 525L97-273 CWD-245 10 85.3 245,000 211,000 183,000 3" or 4" 41-3/8" 36-5/8" 22-1/8" 580

Bali Gas Fired Hot Water Boilers Induced Draft, Electronic Ignition•Approved for installation on non-carpeted

combustible floors •Cast iron heat exchanger •Step opening gas valve for smooth ignition •Supply tapping located off top of boiler • Integral fan for side-wall venting •Category III side-wall or vertical venting with

AL294C stainless steel venting material •May be chimney vented using optional

category I venting • Induced draft blower with pressure switch •Honeywell electronic ignition system with 30

second pre-purge •Universal vent adapter •High performance circulator with isolation

flanges •Stainless steel burners

•Pressure switch detects venting problems •Rollout switch detects heat exchanger

blockage •Combination temperature/pressure gauge •Boiler drain •ASME relief valve set at 30 PSI •Two-tone powder coated jacket insulated

with fiberglass •Natural gas (LP gas available at participating

locations) •For altitudes above 2,000', ratings should be

reduced at rate of 4% for each 1,000' above sea level

•Boiler must be ordered for proper elevation above sea level when being installed at altitudes above 2,000

Order # Mfg. # AFUE BtuH InputDOE Htg. Capacity BtuH IBR Rating BtuH Flue Diam. Width Height Depth Wt. Lbs.

L96-586 BWF061ENST1PSU 83.3% 61,000 51,000 44,000 3" 14-1/4" 36-11/16" 26-3/4" 282L96-587 BWF095ENST1PSU 83.1% 95,000 78,000 68,000 3" 17-1/2" 36-11/16" 26-3/4" 332L96-588 BWF128ENST1PSU 82.8% 128,000 106,000 92,000 3" 20-3/4" 36-11/16" 26-3/4" 382

Tobago Cast Iron Oil Hot Water Boilers With Front Mounted Tankless Coil for Domestic Hot Water•NOT FOR INSTALLATION ON

COMBUSTIBLE FLOORS •High efficiency — to 85.8% AFUE •Two-tone powder coated jacket, resists

scratching, insulated with fiberglass to minimize wasteful heat loss

•Split top jacket panel easily removed •Higher capacities can be achieved by

changing the nozzle size •Chimney vent •Wet base construction surrounds combustion

area at top, bottom, rear and sides of boiler

•Combustion chamber has a ceramic fiber target wall with floor blanket

•Swing open burner door for easy service•The BNR capacity of L96-589 is 0.75,

L97-262 is 1.0 and L96-590 is 1.25 •Standard equipment includes: Oil solenoid

valve, burner twist disconnect, flame retention oil burner with interrupted ignition, combination aquastat/relay, draft regulator, 1-1/2" circulator, combination temperature/pressure gauge, boiler drain valve, ASME relief valve

Order # Mfg. # Sections AFUEDOE Htg. Capacity BtuH IBR Rating BtuH Width Height Wt. Lbs.

L96-589 TWZ075BOTT1PSU 3 85.8 91,000 79,000 24-1/2" 31-1/2" 560L97-262 TWZ100BOTT1PSU 3 84.3 120,000 104,000 24-1/2" 31-1/2" 560L96-590 TWZ125BOTT1PSU 4 84.9 152,000 132,000 24-1/2" 31-1/2" 680

Page 4: Crown Catalog Pages

571Large local inventories. More products online at johnstonesupply.com

HVAC EQUIPMENTBoilers

Freeport CT Cast Iron Oil Hot Water Boilers For New and Old Homes with Chimneys•Full lifetime warranty on cast iron heat

exchanger •Chimney required •Three-pass Scotch Marine design provides

full heating value •Fast response from low water content •Easily serviced with a swing open access

door

•Ultra compact size •Positive pressure Beckett burner•The BNR capacity of L97-263 is 1.0 and

L97-264 is 1.35

Order # Mfg. # Sections AFUEDOE Htg. Capacity BtuH IBR Rating BtuH Width Height Depth Wt. Lbs.

L97-263 CTPB-35 3 84.7 120,000 104,000 25" 26" 19-1/4" 443L97-264 CTPB-45 4 84.0 160,000 139,000 25" 26" 24-1/4" 527

Commercial Atmospheric Natural Gas Fired Hot Water or Steam Boilers For Businesses, Institutions, Commercial Buildings•Cast iron sections and push nipples with

stainless burners •Built-in draft hood fits under low ceilings •Modular design, shipped unassembled, for

easy installation •Optional tankless coil for domestic hot water

on water boilers •Steam boilers tapped for a Mega-Store or

Maxi-Therm indirect water heater

•Available with standard or CSD-1 control systems

•Sizes from 475 to 2,850 MBH inputNote: Contact your local Johnstone Supply for complete information on Crown Boiler Series 32 Commercial Boilers.

Indirect Water Heaters Mega-Stor High Efficiency•Provides more gallons of water after an hour

of heating than gas, electric or oil-fired water heaters

•Stainless steel tanks and coil come with a lifetime guarantee

•Adjustable aquastat •Available from 26 to 119 gallons

•L99-404 and L99-405 are horizontal storage tanks

•L99-401 through L99-403 meet Z21.3 requirements and approved for closet installation

Order # Mfg. # Gallons First Hour GPH BtuH Output Diam. Length Height Wt. Lbs.Indirect Water HeatersL97-265 MS-26 26.4 142 110,000 20-1/4" — 38-1/4" 49L96-356 MS-40 39.6 166 120,000 20-1/4" — 54-3/4" 77L96-357 MS-53 52.8 253 164,000 23-7/8" — 47-7/8" 103L96-358 MS-79 79.3 253 190,000 23-3/4" — 69-1/4" 204L96-359 MS-119 119.0 350 386,000 29-1/4" — 66" 218HorizontalL99-404 MSH-40H 38 151.4 75,088 34-3/4" 23-7/8" 24-3/8" 168L99-405 MSH-53H 51 202.9 100,890 44-7/8" 23-7/8" 24-3/8" 193

Solar Indirect Water Heaters

Order # Mfg. # Gallons Diam. Height Wt. Lbs.L99-406 MSS-79S 76 24" 68-3/4" 126L99-407 MSS-119S 116 29" 67" 210